MARKTECH TLYK31TPF

TLYK31TP(F)
TOSHIBA LED Lamp
InGaAℓP Yellow Light Emission
TLYK31TP(F)
Panel Circuit Indicator
Unit in mm
•
Lead(Pb)-free products (lead: Sn-Ag-Cu)
•
5 mm package
•
InGaAℓP technology
•
Transparent lens
•
Low drive current, high intensity yellow light emission
•
All plastic molded lens, provides an excellent on−off contrast ratio.
•
Fast response time, capable of pulse operation.
•
Applications: outdoor message signboards,Traffic signals, Safety
•
Stopper lead type is also available.
6.75±0.2
Recommended forward current: IF = 10~30 mA (DC)
equipment, HMSL,etc
TLYK31T(F)
Maximum Ratings (Ta = 25°C)
Characteristic
Cathode index
Symbol
Rating
Unit
Forward current (DC)
IF
50
mA
Reverse voltage
VR
4
V
Power dissipation
PD
130
mW
Operating temperature range
Topr
−40~100
Storage temperature range
Tstg
−40~120
1. ANODE
2. CATHODE
JEDEC
―
°C
EIAJ
―
°C
TOSHIBA
―
Weight: 0.28 g
For part availability and ordering information please call Toll Free: 800.984.5337
Website: www.marktechopto.com | Email: [email protected]
HOL-0133
1
2007-01-24
TLYK31TP(F)
Electrical And Optical Characteristics (Ta = 25°C)
Characteristic
Symbol
Test Condition
Min
Typ.
Max
Unit
Forward voltage
VF
IF = 20 mA
1.9
2.4
2.6
V
Reverse current
IR
VR = 4 V
⎯
⎯
50
µA
Luminous intensity
IV
IF = 20 mA
1530
4000
⎯
mcd
Peak emission wavelength
λP
IF = 20 mA
⎯
(594)
⎯
nm
Spectral line half width
∆λ
IF = 20 mA
⎯
13
⎯
nm
Dominant wavelength
λd
IF = 20 mA
581
590
595
nm
(Note)
(Note)
(Note): Lamps are classified into the following ranks according to Iv and λd, and packed in boxes
by each rank.
Iv-rank ⇒ T: 1530−4140mcd, U: 2720−7360mcd, V: 4760mcd−
λd-rank ⇒ 1: 581−588nm, 2: 585−592nm, 3: 589−595nm
Precaution
•
Please be careful of the followings
Soldering temperature: 260°C max
Soldering time: 3 s max
(Soldering portion of lead: up to 1.6 mm from the body of the device)
•
If the lead is formed, the lead should be formed up to1.6 mm from the body of the device without forming stress
to the resin. Soldering should be performed after lead forming.
•
This visible LED lamp also emits some IR light. If a photodetector is located near the LED lamp, please ensure
that it will not be affected by this IR light.
HOL-0133
2
2007-01-24
TLYK31TP(F)
IF – V F
IV – IF
10000
100
Ta = 25 °C
Ta = 25°C
Luminous intensity IV (mcd)
(mA)
50
Forward current IF
30
10
5
3
1
1.6
1.8
2.0
2.2
2.4
2.6
Forward voltage VF
1000
100
30
2.8
1
3
5
10
Forward current IF
(V)
30
50
100
(mA)
Relative Luminous Intensity
Wavelength
IV – Tc
1.0
10
IF = 20 mA
Ta = 25°C
5
Relative luminous intensity
Relative luminous intensity IV
0.8
3
1
0.5
0.3
0.1
−20
0
20
40
60
0.6
0.4
0.2
0
540
80
560
Case temperature Tc (°C)
580
600
620
640
660
100
120
Wavelength λ (nm)
IF – Ta
Radiation Pattern
80
20°
10°
0°
10°
20°
30°
30°
40°
40°
50°
50°
60°
60°
70°
70°
60
40
20
80°
80°
90°
Allowable forward current
IF (mA)
Ta = 25 °C
0
0.2
0.4
0.6
0.8
90°
1.0
0
0
20
40
60
Ambient temperature
HOL-0133
3
80
Ta (°C)
2007-01-24
TLYK31TP(F)
RESTRICTIONS ON PRODUCT USE
000707EAC
• TOSHIBA is continually working to improve the quality and reliability of its products. Nevertheless, semiconductor
devices in general can malfunction or fail due to their inherent electrical sensitivity and vulnerability to physical
stress. It is the responsibility of the buyer, when utilizing TOSHIBA products, to comply with the standards of
safety in making a safe design for the entire system, and to avoid situations in which a malfunction or failure of
such TOSHIBA products could cause loss of human life, bodily injury or damage to property.
In developing your designs, please ensure that TOSHIBA products are used within specified operating ranges as
set forth in the most recent TOSHIBA products specifications. Also, please keep in mind the precautions and
conditions set forth in the “Handling Guide for Semiconductor Devices,” or “TOSHIBA Semiconductor Reliability
Handbook” etc..
• The TOSHIBA products listed in this document are intended for usage in general electronics applications
(computer, personal equipment, office equipment, measuring equipment, industrial robotics, domestic appliances,
etc.). These TOSHIBA products are neither intended nor warranted for usage in equipment that requires
extraordinarily high quality and/or reliability or a malfunction or failure of which may cause loss of human life or
bodily injury (“Unintended Usage”). Unintended Usage include atomic energy control instruments, airplane or
spaceship instruments, transportation instruments, traffic signal instruments, combustion control instruments,
medical instruments, all types of safety devices, etc.. Unintended Usage of TOSHIBA products listed in this
document shall be made at the customer’s own risk.
• Gallium arsenide (GaAs) is a substance used in the products described in this document. GaAs dust and fumes
are toxic. Do not break, cut or pulverize the product, or use chemicals to dissolve them. When disposing of the
products, follow the appropriate regulations. Do not dispose of the products with other industrial waste or with
domestic garbage.
• The information contained herein is presented only as a guide for the applications of our products. No
responsibility is assumed by TOSHIBA CORPORATION for any infringements of intellectual property or other
rights of the third parties which may result from its use. No license is granted by implication or otherwise under
any intellectual property or other rights of TOSHIBA CORPORATION or others.
HOL-0133
4
2007-01-24