TOTAL-POWER S2A03R

TOTAL POWER INT'L
S2A00R Series 3 Watt Low Cost DIP DC/DC Converters
Single & Dual Output
Key Features
l Low Cost
l Regulated Outputs
l 40mV P-P Ripple and Noise
l I / O Isolation 500VDC
l Short Circuit Protected
l MTBF > 600,000 Hours
Low
Dropout
Regulator
+Vin
LC
Filter
+Vo
Bipolar
Push-Pull
Inverter
-Vin
-Vo
+Vo
Positive
Regulator
+Vin
LC
Filter
Bipolar
Push-Pull
Inverter
Com.
-Vin
Negative
Regulator
-Vo
Mechanical Configuration
Pin Connections
1.25 (31.8)
0.40
(10.2)
Side
0.15 (3.8)
0.10
(2.54)
0.02 DIA
(0.5)
0.08
(2.0)
Pin
Single Output
Dual Output
1,24
+Input
+Input
2,23
NC
-Output
3,22
NC
Common
10,15
-Output
Common
11,14
+Output
+Output
12,13
-Input
-Input
NC:No Connection.
0.10 (2.54)
1
12
0.60
(15.2)
Bottom
24
0.80
(20.3)
13
All dimensions typical in inches (mm). Tolerance= +/- 0.01 (+/- 0.25)
Physical Characteristics
Case Size
31.8*20.3*10.2 mm
1.25*0.8*0.4 inches
Case Material
Black Coated Metal
Weight
14g
TOTAL POWER INT'L Tel: 877-646-0900 Fax: 978-453-7395
Email: [email protected] http://www.total-power.com
-1-
TOTAL POWER INT'L
S2A00R
Absolute Maximum Ratings
Exceeding these values can damage the module.These are not continuous operating ratings.
Parameter
Input Surge Voltage
( 1000 mS )
Min.
Max.
Unit.
5VDC Input Models
-0.7
7.5
VDC
12VDC Input Models
-0.7
15
VDC
24VDC Input Models
-0.7
30
VDC
48VDC Input Models
-0.7
55
VDC
---
3000
mW
Internal Power Dissipation
Environmental Specifications
Parameter
Conditions
Operating Temperature
Min.
Typ.
Max.
Unit
-25
---
+71
]
Storage Temperature
-40
---
+125
]
Humidity
---
---
95
%
Cooling
Free-Air Convection
Model Selection Guide
Model
Number
Input
voltage
Output
Voltage
Output
Current
Output
Current
VDC
VDC
mA (Max.)
mA (Min.)
5
600
12
250
15
200
S2A04R
{12
{125
1000
60
S2A05R
{15
{100
1000
60
S2A06R
5
600
420
60
S2A07R
12
250
400
S2A01R
S2A02R
S2A03R
S2A08R
5
(4.5 ~ 5.5)
12
(10.8 ~13.2)
Input
Current
Max. Load
mA (Typ.)
Input
Current
No Load
mA (Typ.)
Reflected
Ripple
Current
mA (Typ.)
1000
0
960
400
% (Typ.)
60
960
0
Efficiency
62
100
100
62
62
50
40
15
200
S2A09R
{12
{125
420
60
S2A10R
{15
{100
420
60
60
S2A11R
5
600
210
S2A12R
12
250
195
S2A13R
24
(21.6~26.4)
0
64
25
25
15
200
S2A14R
{12
{125
210
60
S2A15R
{15
{100
210
60
S2A16R
5
600
105
60
12
250
15
200
S2A19R
{12
{125
105
60
S2A20R
{15
{100
105
60
S2A17R
S2A18R
48
(43.2 ~ 52.8)
195
62
100
0
100
64
62
15
10
62
Specifications typical at Ta=+25],resistive load,nominal input voltage,rated output current unless otherwise noted.
TOTAL POWER INT'L Tel: 877-646-0900 Fax: 978-453-7395
Email: [email protected] http://www.total-power.com
-2-
TOTAL POWER INT'L
S2A00R
Input Specifications
Parameter
Input Voltage Range
Model
Min.
Typ.
Max.
5V Input Models
4.5
5
5.5
12V Input Models
10.8
12
13.2
24V Input Models
21.6
24
26.4
48V Input Models
43.2
48
52.8
---
---
0.5
A
---
---
2500
mW
Reverse Polarity Input Current
All Models
Short Circuit Input Power
Input Filter
Unit
VDC
Pi Filter
Output Specifications
Parameter
Conditions
Min.
Typ.
Max.
Unit
---
{2.0
{4.0
%
Dual Output Balance Load
---
{1.0
{3.0
%
Line Regulation
Vin=Min. to Max.
---
{0.2
{0.5
%
Load Regulation
Io=10% to 100%
---
{0.2
{0.5
%
---
40
50
mV P-P
---
---
75
mV P-P
Ripple & Noise (20MHz)
---
---
5
mV rms.
Over Load
120
---
---
%
---
---
50
uS
---
---
{6
%
Temperature Coefficient
---
{0.01
{0.02
%/]
Output Short Circuit
Continuous
Output Voltage Accuracy
Output Voltage Balance
Ripple & Noise (20MHz)
Ripple & Noise (20MHz)
Over Line,Load & Temp.
Transient Recovery Time
50% Load Step Change
Transient Response Deviation
General Specification
Parameter
Isolation Voltage
Isolation Resistance
Isolation Capacitance
Conditions
Min.
Typ.
Max.
Unit
60 Seconds
500
---
---
VDC
500VDC
1000
---
---
M[
100KHz,1V
---
100
150
pF
40
80
---
kHz
Switching Frequency
Typical Applications
+Vin
+
Fuse
DC Power
Source
-
+Out
Fuse
Single Output
DC / DC
Converter
-Vin
+Vin
+
Load
-Out
DC Power
Source
-
+Out
Dual Output
DC / DC
Converter
-Vin
Load #1
Common
Load #2
-Out
Input Fuse Selection Guide
5V Input Models
12V Input Models
24V Input Models
48V Input Models
2000mA Slow - Blow Type
1000mA Slow - Blow Type
500mA Slow - Blow Type
200mA Slow - Blow Type
TOTAL POWER INT'L Tel: 877-646-0900 Fax: 978-453-7395
Email: [email protected] http://www.total-power.com
-3-
TOTAL POWER INT'L
S2A00R
Derating Curve
Dual Output
Output
Power
%
100
100
80
80
60
60
40
40
-2.9% / OC
20
20
0
0
-25
-10
0
20
40
60
Ambient Temperature
Single Output
Output
Power
%
Output
Power
%
80
100
125
O
C
100
100
80
80
60
60
40
40
-4.2% / OC
20
Output
Power
%
20
0
0
-25
-10
0
20
40
60
Ambient Temperature
80
100
125
O
C
Connecting Pin Patterns
(2.54 mm / 0.1 inch grids )
NOTE:
1. Specifications typical at Ta=+25],resistive load,nominal input voltage,rated output current unless otherwise noted.
2. Transient recovery time is measured to within 1% error band for a step change in output load of 50% to 100%.
3. Other input and output voltage may be available,Please contact factory.
4. Specifications subject to change without notice.
TOTAL POWER INT'L Tel: 877-646-0900 Fax: 978-453-7395
Email: [email protected] http://www.total-power.com
-4-