TOTAL POWER INT'L S2A00R Series 3 Watt Low Cost DIP DC/DC Converters Single & Dual Output Key Features l Low Cost l Regulated Outputs l 40mV P-P Ripple and Noise l I / O Isolation 500VDC l Short Circuit Protected l MTBF > 600,000 Hours Low Dropout Regulator +Vin LC Filter +Vo Bipolar Push-Pull Inverter -Vin -Vo +Vo Positive Regulator +Vin LC Filter Bipolar Push-Pull Inverter Com. -Vin Negative Regulator -Vo Mechanical Configuration Pin Connections 1.25 (31.8) 0.40 (10.2) Side 0.15 (3.8) 0.10 (2.54) 0.02 DIA (0.5) 0.08 (2.0) Pin Single Output Dual Output 1,24 +Input +Input 2,23 NC -Output 3,22 NC Common 10,15 -Output Common 11,14 +Output +Output 12,13 -Input -Input NC:No Connection. 0.10 (2.54) 1 12 0.60 (15.2) Bottom 24 0.80 (20.3) 13 All dimensions typical in inches (mm). Tolerance= +/- 0.01 (+/- 0.25) Physical Characteristics Case Size 31.8*20.3*10.2 mm 1.25*0.8*0.4 inches Case Material Black Coated Metal Weight 14g TOTAL POWER INT'L Tel: 877-646-0900 Fax: 978-453-7395 Email: [email protected] http://www.total-power.com -1- TOTAL POWER INT'L S2A00R Absolute Maximum Ratings Exceeding these values can damage the module.These are not continuous operating ratings. Parameter Input Surge Voltage ( 1000 mS ) Min. Max. Unit. 5VDC Input Models -0.7 7.5 VDC 12VDC Input Models -0.7 15 VDC 24VDC Input Models -0.7 30 VDC 48VDC Input Models -0.7 55 VDC --- 3000 mW Internal Power Dissipation Environmental Specifications Parameter Conditions Operating Temperature Min. Typ. Max. Unit -25 --- +71 ] Storage Temperature -40 --- +125 ] Humidity --- --- 95 % Cooling Free-Air Convection Model Selection Guide Model Number Input voltage Output Voltage Output Current Output Current VDC VDC mA (Max.) mA (Min.) 5 600 12 250 15 200 S2A04R {12 {125 1000 60 S2A05R {15 {100 1000 60 S2A06R 5 600 420 60 S2A07R 12 250 400 S2A01R S2A02R S2A03R S2A08R 5 (4.5 ~ 5.5) 12 (10.8 ~13.2) Input Current Max. Load mA (Typ.) Input Current No Load mA (Typ.) Reflected Ripple Current mA (Typ.) 1000 0 960 400 % (Typ.) 60 960 0 Efficiency 62 100 100 62 62 50 40 15 200 S2A09R {12 {125 420 60 S2A10R {15 {100 420 60 60 S2A11R 5 600 210 S2A12R 12 250 195 S2A13R 24 (21.6~26.4) 0 64 25 25 15 200 S2A14R {12 {125 210 60 S2A15R {15 {100 210 60 S2A16R 5 600 105 60 12 250 15 200 S2A19R {12 {125 105 60 S2A20R {15 {100 105 60 S2A17R S2A18R 48 (43.2 ~ 52.8) 195 62 100 0 100 64 62 15 10 62 Specifications typical at Ta=+25],resistive load,nominal input voltage,rated output current unless otherwise noted. TOTAL POWER INT'L Tel: 877-646-0900 Fax: 978-453-7395 Email: [email protected] http://www.total-power.com -2- TOTAL POWER INT'L S2A00R Input Specifications Parameter Input Voltage Range Model Min. Typ. Max. 5V Input Models 4.5 5 5.5 12V Input Models 10.8 12 13.2 24V Input Models 21.6 24 26.4 48V Input Models 43.2 48 52.8 --- --- 0.5 A --- --- 2500 mW Reverse Polarity Input Current All Models Short Circuit Input Power Input Filter Unit VDC Pi Filter Output Specifications Parameter Conditions Min. Typ. Max. Unit --- {2.0 {4.0 % Dual Output Balance Load --- {1.0 {3.0 % Line Regulation Vin=Min. to Max. --- {0.2 {0.5 % Load Regulation Io=10% to 100% --- {0.2 {0.5 % --- 40 50 mV P-P --- --- 75 mV P-P Ripple & Noise (20MHz) --- --- 5 mV rms. Over Load 120 --- --- % --- --- 50 uS --- --- {6 % Temperature Coefficient --- {0.01 {0.02 %/] Output Short Circuit Continuous Output Voltage Accuracy Output Voltage Balance Ripple & Noise (20MHz) Ripple & Noise (20MHz) Over Line,Load & Temp. Transient Recovery Time 50% Load Step Change Transient Response Deviation General Specification Parameter Isolation Voltage Isolation Resistance Isolation Capacitance Conditions Min. Typ. Max. Unit 60 Seconds 500 --- --- VDC 500VDC 1000 --- --- M[ 100KHz,1V --- 100 150 pF 40 80 --- kHz Switching Frequency Typical Applications +Vin + Fuse DC Power Source - +Out Fuse Single Output DC / DC Converter -Vin +Vin + Load -Out DC Power Source - +Out Dual Output DC / DC Converter -Vin Load #1 Common Load #2 -Out Input Fuse Selection Guide 5V Input Models 12V Input Models 24V Input Models 48V Input Models 2000mA Slow - Blow Type 1000mA Slow - Blow Type 500mA Slow - Blow Type 200mA Slow - Blow Type TOTAL POWER INT'L Tel: 877-646-0900 Fax: 978-453-7395 Email: [email protected] http://www.total-power.com -3- TOTAL POWER INT'L S2A00R Derating Curve Dual Output Output Power % 100 100 80 80 60 60 40 40 -2.9% / OC 20 20 0 0 -25 -10 0 20 40 60 Ambient Temperature Single Output Output Power % Output Power % 80 100 125 O C 100 100 80 80 60 60 40 40 -4.2% / OC 20 Output Power % 20 0 0 -25 -10 0 20 40 60 Ambient Temperature 80 100 125 O C Connecting Pin Patterns (2.54 mm / 0.1 inch grids ) NOTE: 1. Specifications typical at Ta=+25],resistive load,nominal input voltage,rated output current unless otherwise noted. 2. Transient recovery time is measured to within 1% error band for a step change in output load of 50% to 100%. 3. Other input and output voltage may be available,Please contact factory. 4. Specifications subject to change without notice. TOTAL POWER INT'L Tel: 877-646-0900 Fax: 978-453-7395 Email: [email protected] http://www.total-power.com -4-