A600ERU Series Single & Dual Output, 6W Ultra-Wide Input Range DC/DC Converters Electrical Specifications Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice. Input Key Features: • 6W Output Power • 4:1 Input Voltage Range • 1,500 VDC Isolation • -40ºC to +85ºC Temp Range • Compact DIP Case • Single & Dual Outputs • 1.0 MH MTBF • Industry Standard Pin-Out • Low, Low Cost Parameter Conditions Input Voltage Range (See Note 1) Min. Typ. Max. 24 VDC Input 9.0 24.0 36.0 48 VDC Input 18.0 48.0 72.0 Input Filter Units VDC Capacitors Reverse Polarity Input Current Short Circuit Input Power 1.0 A 2,500 mW Output Parameter Conditions Typ. Max. Units See Note 2 ±1.0 ±3.0 % Dual Output , Balanced Loads ±3.0 Vin = Min to Max ±0.2 ±0.5 % Load Regulation See Note 3 ±0.5 ±1.0 % Noise (20 Hz - 300 kHz) See Note 4 30 50 mV P - P 100 300 mV P - P ±0.01 ±0.02 %/ºC Typ. Max. Units Output Voltage Accuracy Output Voltage Balance Line Regulation Min. Ripple (DC - 20 MHz) Output Power Protection % 120 Temperature Coefficient Output Short Circuit % Continuous General Parameter Conditions Isolation Voltage Isolation Resistance Switching Frequency Min. 60 Seconds 1,500 500 VDC 1,000 VDC M⍀ Single Output 300 Dual Output 250 kHz Environmental Parameter Conditions Operating Temperature Range Min. Ambient Storage Temperature Range Cooling Max. Units -40 Typ. +85 ºC -55 +125 ºC Free Air Convection Humidity RH, Non-condensing 95 % Physical Case Size 1.25 x 0.80 x 0.40 Inches (31.8 x 20.3 x 10.2 mm) MicroPower Direct Case Material 292 Page Street Suite D Stoughton, MA 02072 USA Weight Metal With Non-Conductive Base (UL94V-0) 0.49 Oz (14g) Reliability Specifications Parameter Conditions MTBF T: (781) 344-8226 F: (781) 344-8481 E: [email protected] W: www.micropowerdirect.com Min. MIL HDBK 217F, 25ºC, Gnd Benign Typ. Max. 1.0 Units MHours Absolute Maximum Ratings Parameter Conditions Input Voltage Surge (1 Sec) Lead Temperature Min. Typ. -0.7 50.0 48 VDC Input -0.7 100.0 1.5 mm From Case For 10 Sec Internal Power Dissipation Max. 24 VDC Input All Models VDC 300 ºC 2,500 mW Caution: Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings. www.micropowerdirect.com Units www.micropowerdirect.com Model Selection Guide Model Number Input Current (mA) Voltage (VDC) Nominal Range 24 24 24 24 24 24 24 24 24 48 48 48 48 48 48 48 48 48 9.0 - 36.0 9.0 - 36.0 9.0 - 36.0 9.0 - 36.0 9.0 - 36.0 9.0 - 36.0 9.0 - 36.0 9.0 - 36.0 9.0 - 36.0 18.0 - 72.0 18.0 - 72.0 18.0 - 72.0 18.0 - 72.0 18.0 - 72.0 18.0 - 72.0 18.0 - 72.0 18.0 - 72.0 18.0 - 72.0 Output Fuse Rating Reflected Efficiency Slow-Blow Current Ripple Voltage Current (%, Typ) (mA) (VDC) (mA, Max) (mA, Min) Full-Load No-Load Current (mA, Typ) A601ERU A602ERU A603ERU A604ERU A605ERU A606ERU A607ERU A608ERU A609ERU A611ERU A612ERU A613ERU A614ERU A615ERU A616ERU A617ERU A618ERU A619ERU 278 312 304 304 301 312 304 298 294 137 156 152 147 145 156 152 149 147 20 20 20 20 20 20 20 20 20 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 3.3 5.0 12.0 15.0 24.0 ±5.0 ±12.0 ±15.0 ±24.0 3.3 5.0 12.0 15.0 24.0 ±5.0 ±12.0 ±15.0 ±24.0 Notes: 1. Exceeding the input range by a significant margin may damage the units. For 24V input the input voltage should not exceed 40V; for 48V models it should not exceed 80V. 2. Output accuracy for the negative output of dual output units is typically ±3% (±5% max.). 3. Output load regulation is specified for a load change of 10% to 100%. For 3.3V output units, the load regulation is ±1.5% max. 4. When measuring output ripple, it is recommended that an external 0.33 µF ceramic capacitor be placed from the +Vout pin to the -Vout pin for single output units and from each output to common for dual output units. 5. These units should not be operated with a load under the specified minimum. Operation at no-load will increase ripple significantly and may cause damage to the unit. 6. These converters are specified for operation without external components. However, in some applications the addition of input/output capacitors will enhance stability and reduce output ripple. Recommended capacitor values are: Input Vout Capacitor 24 VDC 100 µF 3.3 VDC 48 VDC 100 µF 5 VDC 12 VDC 15 VDC 24 VDC Vin Output Capacitor 100 µF 100 µF 100 µF 47 µF 47 µF 1,500 1,200 500 400 250 ±600 ±250 ±200 ±125 1,500 1,200 500 400 250 ±600 ±250 ±200 ±125 150.0 120.0 50.0 40.0 25.0 ±60.0 ±25.0 ±20.0 ±13.0 150.0 120.0 50.0 40.0 25.0 ±60.0 ±25.0 ±20.0 ±13.0 75 80 82 82 83 80 82 84 85 76 80 82 85 86 80 82 84 85 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 750 750 750 750 750 750 750 750 750 Derating Curve Mechanical Dimensions For applications requiring very low output noise levels, a simple LC filter should be effective. 7. It is recommended that a fuse be used on the input of a power supply for protection. See the Model Selection table above for the correct rating. Pin Connections Pin Single 2, 3 -Vin Dual -Vin 9 No Pin Common 11 NC -Vout 14 +Vout +Vout 16 -Vout Common 22, 23 +Vin +Vin NC: No Connection MicroPower Direct Mechanical Notes: • All dimensions are typical in inches (mm) • Tolerance x.xx = ±0.01 (±0.25) We Power Your Success - For Less! 292 Page Street Ste D Stoughton, MA 02072 • TEL: (781) 344-8226 • FAX: (781) 344-8481 • E-Mail: [email protected]