ETC OM7635SM

OM7635SM
SURFACE MOUNT POSITIVE ADJUSTABLE
1.0 AMP VOLTAGE REGULATOR
Isolated Hermetic Surface Mount Package
1.0 Amp, Positive Adjustable Voltage
Regulator
FEATURES
•
•
•
•
•
•
•
Hermetic Isolated Surface Mount Package
Adjustable Output Voltage
Eliminates Stocking Fixed Voltages
Built-In Thermal Overload Protection
Short Circuit Current Limiting
Product Is Available Hi-Rel Screened
Electrically Similar To Industry Standard P/N LM117
DESCRIPTION
This three terminal positive regulator is supplied in a hermetically sealed metal
surface mount package. All protective features are designed into the circuit, including
thermal shutdown, current limiting and safe-area control. With heat sinking, they can
deliver over 1.0 amp of output current. This unit features output voltages that can be
trimmed using external resistors, from 1.2 volts to 37 volts.
ABSOLUTE MAXIMUM RATINGS
Input to Output Voltage Differential . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 405 V
Operating Junction Temperature Range. . . . . . . . . . . . . . . . . . . . . . . . - 55°C to + 150°C
Storage Temperature Range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . - 55°C to + 150°C
Typical Power/Thermal Characteristics:
Rated Power @ 25°C
TC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17.5W
TA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3W
Thermal Resistance:
θJC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.5°C/W
θJA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42°C/W
Lead Temperature at Case (5 sec) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 225°C
3.5
4 11 R1
Supersedes 1 05 R0
3.5 - 127
OM7635SM
ELECTRICAL CHARACTERISTICS
-55°C ≤ TA ≤ 125°C, IL = 8mA (unless otherwise specified)
Parameter
Symbol
Test Conditions
Min.
Max.
Reference Voltage
VREF
VDIFF = 3.0V, TA = 25°C
1.20
1.30
•
•
1.20
1.30
1.20
1.30
-9
9
•
-23
23
-15
15
-15
15
-15
15
VDIFF = 3.3V
VDIFF = 40V
Line Regulation
RLINE
(Note 1)
3.0V ≤ VDIFF ≤ 40V, Vout = Vref, TA = 25°C
3.3V ≤ VDIFF ≤ 40V, Vout = Vref
Load Regulation
RLOAD
VDIFF = 3.0V, 10mA ≤ IL ≤ 1.5A, TA = 25°C
•
VDIFF = 3.3V, 10mA ≤ IL ≤ 1.5A
(Note 1)
VDIFF = 40V, 10mA ≤ IL ≤ 300mA, TA = 25°C
•
VDIFF = 40V, 10mA ≤ IL ≤ 195mA
Thermal Regulation
VRTH
Vin = 14.6V, IL = 1.5A
-15
15
-16
16
Unit
V
mV
mV
mV
Pd = 20 Watts, t = 20 ms, TA =25°C
Ripple Rejection
RN
(Note 2)
•
f = 120 Hz, Vout = Vref
66
dB
CAdj = 10 µF, Iout = 100 mA
Adjustment Pin Current
IAdj
VDIFF = 3.0V, TA = 25°C
100
•
•
VDIFF = 3.3V
VDIFF = 40V
Adjustment Pin
∆IAdj
Current Change
VDIFF = 3.0V, 10mA ≤ IL ≤ 1.5A, TA = 25°C
VDIFF = 3.3V, 10mA ≤ IL ≤ 1.5A
VDIFF = 40V, 10mA ≤ IL ≤ 300mA, TA = 25°C
VDIFF = 40V, 10mA ≤ IL ≤ 195mA
•
•
•
3.0V ≤ VDIFF ≤ 40V, TA = 25°C
•
3.3V ≤ VDIFF ≤ 40V
Miminum Load Current
ILmin
5
-5
5
-5
5
-5
5
-5
5
-5
ICL
µA
5
5.0
•
•
•
VDIFF = 40V, VOUT = 1.4V (forced)
(Note 2)
µA
100
-5
VDIFF = 3.0V, VOUT = 1.4V (forced)
VDIFF = 3.3V, VOUT = 1.4V (forced)
Current Limit
100
VDIFF = 15V
VDIFF = 40V, TA = 25°C
5.0
mA
5.0
1.5
3.5
0.18
1.5
A
Notes:
1. Load and Line Regulation are specified at a constant junction temperature. Pulse testing with low duty cycle is used.
Changes in output voltage due to heating effects must be taken into account separately.
2. If not tested, shall be guaranteed to the specified limits.
3. The • denotes the specifications which apply over the full operating temperature range.
PIN CONNECTION
MECHANICAL OUTLINE
.425H
2
1
H
.100H
.200H
.425H
H
3.5
.035 WIDEH
FLAT 3 PLCS.H
H
.350 MIN.H
H
± .020H
.115H
.160H
.020H
.080 H
3
Pin 1:
Pin 2:
Pin 3:
Case:
VOUT
Adjust
VIN
Isolated