TOTAL-POWER TPS40-11

TOTAL POWER INT'L
PPS40-1/2/3
SWITCHING MODE 40W OPEN FRAME POWER SUPPLIES
TPS40-1/2/3 40 WATT OPEN-FRAME SWITCHING POWER SUPPLY
KEY FEATURES
*Universal input
* Built-in EMI filter
*Optional±12VDC/±24VDC/±48VDC input
APPLICATIONS
*Telecommunications
*Computer peripherals/ Lan & Hub
*Test & industrial equipments
*Medical instruments
*Business machines
ELECTRICAL SPECIFICATIONS
EMI & EMC
INPUT
*FCC part 15, Class B
*CISPR 22 / EN55022, Class B
*VCCI ,Class 2
*CE, EN 61000-3-2 (Class A) and –3; EN 61000-4-2,
*Input range-----------90~264 VAC, universal
*Frequency------------47~63Hz
*Inrush current--------25A typical, Cold start @25℃,115VAC
*Efficiency------------65% ~80% typical at full load
*EMI filter------------ FCC Class B conducted, CISPR 22
Class B conducted, EN55022 class B
Conducted
*Line regulation----- +/- 0.5% typical
OUTPUT
*Maximum power----40W with 15 CFM forced air
(Refer next page)
*Hold-up time --------10ms typical at full load and 115 VAC
nominal line
*Overload protection-Short circuit protection
*Overvoltage
protection ------------Main output 20% to 40% above
nominal output
*Ripple/Noise -------- +/- 1% Max. @full load
(Optional +/-0.5% per inquiry)
Power Derating Curve
40W
15 CFM Forced Air Cooling
30W
Output
Power 20W
(Watts) 10W
Natural
Convection
Cooling
20W
15W
0W
0
10
20
30
40
50
60
-3,-4.-5,-6 and -11
SAFETY APPROVAL
*UL1950 / c UL
*Optional CSA 22.2, LEVEL 3 (COMPLY WITH)
*TUV EN60950
*Optional UL 2601 (EMI Class A)(COMPLY WITH)
ENVIRONMENTAL
*Operating temperature :
0 to 50℃ambient; derate each output at 2.5% per
degree from 50℃to 70℃
*Humidity:
Operating; non-condensing, 5% to 95%
*Vibration :
10~55 Hz at 1G 3 minutes period, 30 minutes along
X, Y and Z axis
*Storage temperature:
-40 to 85℃
*Temperature coefficient:
+/- 0.05% per degree C
*MTBF demonstrated:
>100,000 hours at full load and 25℃ambient
conditions
70
Ambient Temperature( ° C)
TOTAL POWER INT'L Tel: 877-646-0900 Fax: 978-453-7395
Email: [email protected] http://www.total-power.com
-1-
PPS40-1/2/3
MODEL
SWITCHING MODE 40W OPEN FRAME POWER SUPPLIES
OUTPUT
ADJUSTMENT
MAXIMUM OUTPUT
PEAK OUTPUT
MINIMUM OUTPUT
TOTAL
RIPPLE & NOISE
PEAK OUTPUT
VOLTAGE
RANGE
CURRENT
CURRENT(NOTE1)
CURRENT
REGULATION(NOTE3)
%P-P(NOTE2)
POWER(NOTE1)
SI NGLE OUTPUT MODEL SELECTION CHART
TPS40-10
+5V
±10% Typical
8A
10A
0A
±3%
±1%
50W Typical
TPS40-11
+12V
±10% Typical
3.3A
4.1A
0A
±3%
±1%
50W Typical
TPS40-12
+15V
±10% Typical
2.6A
3.2A
0A
±3%
±1%
50W Typical
TPS40-13
+24V
±10% Typical
1.6A
2A
0A
±3%
±1%
50W Typical
TPS40-14
+48V
±10% Typical
0.8A
1A
0A
±3%
±1%
50W Typical
TPS40-15
+3.3V
±10% Typical
9.6A
12A
0.96A
±5%
±1.5%
50W Typical
TPS40-16
+28V
±10% Typical
1.4A
1.8A
0A
±3%
±1%
50W Typical
DUAL OUTPUT MODEL SELECTION CHART
TPS40-20
TPS40-21
TPS40-22
TPS40-23
TPS40-24
TPS40-25
+5 V
±10% Typical
6A
9.6A
0.6A
±5%
±1%
+12V
Fixed
1A
1.6A
0.1A
±5%
±1%
+5 V
±10% Typical
6A
9.6A
0.6A
±5%
±1%
+48V
Fixed
0.25A
0.4A
0.03A
±5%
±1%
+5 V
±10% Typical
6A
9.6A
0.6A
±5%
±1%
- 5V
Fixed
2A
3.2A
0.2A
±10%
±1%
+12V
±10% Typical
1.6A
2.5A
0.16A
±5%
±1%
- 12V
Fixed
1.6A
2.5A
0.16A
±10%
±1%
+15V
±10% Typical
1.3A
2A
0.13A
±5%
±1%
- 15V
Fixed
1.3A
2A
0.13A
±10%
±1%
+3.3V
±10% Typical
10A
16A
1A
±5%
±1.5%
+5V
Fixed
1.5A
2.4A
0.15A
±5%
±1%
50W Typical
50W Typical
50W Typical
50W Typical
50W Typical
50W Typical
TRIPLE OUTPUT MODEL SELECTION CHART
TPS40-30
TPS40-31
TPS40-32
TPS40-33
TPS40-34
TPS40-35
TPS40-36
TPS40-37
TPS40-38
+ 5V
±10% Typical
5A
8A
0.5A
±5%
±1%
+12V
Fixed
0.75A
1.2A
0.08A
±5%
±1%
-5V
Fixed
1.2A
1.9A
0.12A
±1%
+ 5V
±10% Typical
5A
8A
0.5A
±10%
±5%
+12V
Fixed
0.75A
1.2A
0.08A
±5%
±1%
-12V
Fixed
0.5A
0.8A
0.05A
±1%
50W Typical
±1%
+ 5V
±10% Typical
5A
8A
0.5A
±10%
±5%
+15V
Fixed
0.5A
0.8A
0.05A
±5%
±1%
-15V
Fixed
0.5A
0.8A
0.05A
±1%
50W Typical
±1%
+5V
±10% Typical
4A
6.4A
0.4A
±10%
±5%
+15V
Fixed
1A
1.6A
0.1A
±5%
±1%
-5V
Fixed
1A
1.6A
0.1A
±1%
50W Typical
±1%
+5V
±10% Typical
4A
6.4A
0.4A
±10%
±5%
+15V
Fixed
0.8A
1.2A
0.08A
±5%
±1%
-12V
Fixed
0.7A
1.1A
0.07A
±1%
50W Typical
±1%
+ 5V
±10% Typical
4A
6.4A
0.4A
±10%
±5%
+24V
Fixed
0.5A
0.8A
0.05A
±5%
±1%
-12V
Fixed
0.7A
1.1A
0.07A
±1%
50W Typical
±1%
+ 5V
±10% Typical
4A
6.4A
0.4A
±10%
±5%
+12V
Fixed
0.75A
1.2A
0.08A
±5%
±1%
-12V
Fixed
1A
1.6A
0.1A
±1%
50W Typical
±1%
+5V
±10% Typical
4A
6.4A
0.4A
±10%
±5%
+12V
Fixed
0.75A
1.2A
0.08A
±5%
±1%
+24V
Fixed
0.5A
0.8A
0.05A
±1%
+5V
±10% Typical
2.4A
3.8A
0.24A
±10%
±5%
+12V
Fixed
1.2A
1.9A
0.12A
±5%
±1%
50W Typical
±1%
50W Typical
±1%
50W Typical
Fixed
±10%
±1%
+48V
0.3A
0.5A
0.03A
NOTES: 1) Peak loads for lasting <30 seconds with a maximum 10% duty cycle are acceptable. Please contact us if need special peak load.
2) Maximum peak to peak noise expressed as a percentage of output voltage, 20MHz bandwidth, input not less nominal line,0.1μF and 47μF Cap. on outputs.
3) Loading test conditions are set for all outputs at minimum, middle and maximum of loads. Special cross loading requirement is welcomed.
4) Detailed engineering specification of each model is available for inquiry.
5) Special output voltage/current inquiry is welcomed.
6) Specifications subject to change without notice.
7) 25% derated if 24 VDC input version;50% derated if 12 VDC input version;25% derated if additional cover.
TOTAL POWER INT'L Tel: 877-646-0900 Fax: 978-453-7395
Email: [email protected] http://www.total-power.com
-2-