TOTAL POWER INT. TPS40LB SWITCHING MODE 40W LOW COST BOX TYPE POWER SUPPLY KEY FEATURES *Universal input *Built-in EMI filter *LOW COST *Optional constant current change (for single output) APPLICATIONS *Telecommunications *Computer peripherals/Lan & Hub *Test & industrial equipments *Medical instruments *Business machines ELECTRICAL SPECIFICATIONS EMI & EMC (IN PROCESS) INPUT *Input range-----------90~264 VAC, universal *Frequency------------47~63Hz *Inrush current--------30A typical, Cold start @25℃,115VAC *Efficiency------------65% ~80% typical at full load *EMI filter------------ FCC Class B conducted, CISPR 22 Class B conducted, EN55022 class B Conducted *Line regulation----- +/- 0.5% typical OUTPUT *Maximum power----40W convection(Refer next page) *Hold-up time --------10ms typical at full load and 115 VAC nominal line *Overload protection-Short circuit protection *Overvoltage protection ------------Main output 20% to 40% above nominal output *Ripple/Noise -------- +/- 1% Max. @full load (Optional +/-0.5% per inquiry) Power Derating Curve 65W 40W Output Power 25W (Watts) 10W Natural Convection Cooling 20 W 0W 0 10 20 30 40 50 60 70 Ambient Temperature( ° C) *FCC part 15, Class B *CISPR 22 / EN55022, Class B *VCCI ,Class 2 *CE , EN61000-3-2 (Class A) and –3 ; EN61000-4-2, -3 , -4 , -5 , -6 and -11 SAFETY APPROVAL(IN PROCESS) *UL1950 / c UL *Optional CSA 22.2, LEVEL 3 *TUV EN60950 *Optional UL 2601(EMI Class A) ENVIRONMENTAL *Operating temperature : 0 to 50℃ambient; derate each output at 2.5% per degree from 50℃to 70℃ *Humidity: Operating; non-condensing, 5% to 95% *Vibration : 10~55 Hz at 1G 3 minutes period, 30 minutes along X, Y and Z axis *Storage temperature: -40 to 85℃ *Temperature coefficient: +/- 0.05% per degree C *MTBF demonstrated: >100,000 hours at full load and 25℃ambient conditions TOTAL POWER, INT. TEL: 877-646-0900 FAX: 978-453-7395 E-mail: [email protected] http://www.total-power.com -1- TOTAL POWER TPS40LB SWITCHING MODE 40W LOW COST BOX TYPE MODEL OUTPUT ADJUSTMENT MAXIMUM OUTPUT PEAK OUTPUT MINIMUM OUTPUT TOTAL RIPPLE & NOISE PEAK OUTPUT VOLTAGE RANGE CURRENT CURRENT(NOTE1) CURRENT REGULATION(NOTE3) %P-P(NOTE2) POWER(NOTE1) SINGLE OUTPUT MODEL SELECTION CHART TPS40LB-10 +5V ±10% Typical 8A 10.4A 0A ±3% ±1% 52W Typical TPS40LB-11 + 12V ±10% Typical 3.33A 4.33A 0A ±3% ±1% 52W Typical TPS40LB-12 +15V 3.46A 0A ±3% ±1% 52W Typical +24V ±10% Typical ±10% Typical 2.66A TPS40LB-13 1.66A 2.16A 0A ±3% ±1% 52W Typical TPS40LB-14 +48V ±10% Typical 0.83A 1.08A 0A ±3% ±1% 52W Typical TPS40LB-15 +3.3V ±10% Typical 8A 10.4A 0A ±5% ±1.5% 35W Typical DUAL OUTPUT MODEL SELECTION CHART TPS40LB-20 TPS40LB-21 TPS40LB-22 TPS40LB-23 TPS40LB-24 TPS40LB-25 TPS40LB-26 +5V ±10% Typical 4A 7.8A 0.4A ±5% ±1.5% +12 V Fixed 2.5A 5.2A 0.25A ±5% ±1% +5V ±10% Typical 6A 7.8A 0.6A ±5% ±1% +24V Fixed 0.5A 1.3A 0.05A ±5% ±1% +5 V ±10% Typical 5A 6.5A 0.5A ±5% ±1% -5V Fixed 3A 1.3A 0.3A ±5% ±1% +12V ±10% Typical 2A 4.68A 0.2A ±5% ±1% -12V Fixed 2A 1.17A 0.2A ±5% ±1% +15V ±10% Typical 1.4A 2.21A 0.14A ±5% ±1% -15V Fixed 1.4A 2.21A 0.14A ±10% ±1% +3.3V ±10% Typical 8.9A 11.57A 0.89A ±5% ±1.5% +12V Fixed 0.9A 1.17A 0.09A ±10% ±1% +5V ±10% Typical 1A 13A 0.1A ±5% ±1% +48V Fixed 0.8A 0.26A 0.08A ±10% ±1% 52W Typical 52W Typical 52W Typical 52W Typical 52W Typical 52W Typical 52W Typical TRIPLE OUTPUT MODEL SELECTION CHART TPS40LB-30 TPS40LB-31 TPS40LB-32 TPS40LB-33 + 5V ±10% Typical 3A 3.9A 0.3A ±5% ±1% +12V Fixed 2A 2.6A 0.2A ±5% ±1% -5V 0.5A 0.65A 0.05A ±10% ±1% + 5V Fixed ±10% Typical 3A 3.9A 0.3A ±5% ±1% +12V Fixed 2A 2.6A 0.2A ±5% ±1% - 12V 0.5A 0.65A 0.05A ±10% ±1% + 5V Fixed ±10% Typical 3A 3.9A 0.3A ±5% ±1% +15V Fixed 2A 2.6A 0.2A ±5% ±1% -15V 0.5A 0.65A 0.05A ±10% ±1% +5V Fixed ±10% Typical 3A 3.9A 0.3A ±5% ±1% +15V Fixed 2A 2.6A 0.2A ±5% ±1% -5V Fixed ±10% Typical 0.5A 0.65A 0.05A ±10% ±1% 3A 3.9A 0.3A ±5% ±1% 1.5A 1.3A 0.15A ±5% ±1% -12V Fixed Fixed 0.5A 0.65A 0.05A ±10% ±1% + 5V ±10% Typical 3A 3.9A 0.3A ±5% ±1% +24V 1A 1.3A 0.1A ±5% ±1% -12V Fixed Fixed 0.5A 0.65A 0.05A ±10% ±1% +5V ±10% Typical 1A 9.1A 0.1A ±5% ±1.5% +12 2.5A 1.95A 0.25A ±5% ±1% -12V Fixed Fixed 0.5A 1.04A 0.05A ±10% ±1% + 5V ±10% Typical 3A 3.9A 0.3A ±5% ±1% +12V 1.5A 1.3A 0.15A ±5% ±1% +24V Fixed Fixed 0.5A 0.65A 0.05A ±10% ±1% +5V ±10% Typical 2A 9.1A 0.2A ±5% ±1.5% +12V Fixed Fixed 0.5A 1.95A 0.05A ±5% ±1% 0.6A 1.04A 0.06A ±10% ±1% + 5V TPS40LB-34 TPS40LB-35 TPS40LB-36 TPS40LB-37 TPS40LB-38 +15V +48V NOTES: 1) Peak loads for lasting <30 seconds with a maximum 10% duty cycle are acceptable. Please contact us if need special peak load. 2) Maximum peak to peak noise expressed as a percentage of output voltage, 20MHz bandwidth, 0.1μF and 47μF Cap. on outputs. 3) Loading test conditions are set for all outputs at minimum, middle and maximum of loads. Special cross loading requirement is welcomed. 4) Detailed engineering specification of each model is available for inquiry. 5) Special output voltage/current inquiry is welcomed. 6) Specifications subject to change without notice. TOTAL POWER, INT. TEL: 877-646-0900 FAX: 978-453-7395 E-mail: [email protected] http://www.total-power.com -2- 52W Typical 52W Typical 52W Typical 52W Typical 52W Typical 52W Typical 52W Typical 52W Typical 52W Typical