TOTAL POWER INT. TPS25LB SWITCHING MODE 25W LOW COST BOX TYPE POWER SUPPLY KEY FEATURES *Universal input *Built-in EMI filter *LOW COST *Optional constant current change (for single output) APPLICATIONS *Telecommunications *Computer peripherals/ Lan & Hub *Test & industrial equipments *Medical instruments *Business machines ELECTRICAL SPECIFICATIONS EMI & EMC (IN PROCESS) INPUT *FCC part 15, Class B *CISPR 22 / EN55022, Class B *VCCI ,Class 2 *CE , EN61000-3-2 (Class A) and –3 ; EN61000-4-2, -3 , -4 , -5 , -6 and -11 *Input range-----------90~264 VAC, universal *Frequency------------47~63Hz *Inrush current--------25A typical, Cold start @25℃,115VAC *Efficiency------------65%~80% typical at full load *EMI filter------------ FCC Class B conducted, CISPR 22 Class B conducted, EN55022 class B Conducted *Line regulation----- +/- 0.5% typical OUTPUT *Maximum power----25W convection (Refer next page) *Hold-up time --------10ms typical at full load and 115 VAC nominal line *Overload protection-Short circuit protection *Overvoltage protection ------------Main output 20% to 40% above nominal output *Ripple/Noise -------- +/- 1% Max. @full load (Optional +/-0.5% per inquiry) Power Derating Curve 40W 25W Output Power 20W (Watts) 10W Natural Convection Cooling 12.5W 0W 0 10 20 30 40 50 60 70 Ambient Temperature( ° C) SAFETY APPROVAL(IN PROCESS) *UL1950 / c UL *Optional CSA 22.2, LEVEL 3 *TUV EN60950 *Optional UL 2601 (EMI Class A) ENVIRONMENTAL *Operating temperature : 0 to 50℃ambient; derate each output at 2.5% per degree from 50℃to 70℃ *Humidity: Operating; non-condensing, 5% to 95% *Vibration : 10~55 Hz at 1G 3 minutes period, 30 minutes along X, Y and Z axis *Storage temperature: -40 to 85℃ *Temperature coefficient: +/- 0.05% per degree C *MTBF demonstrated: >100,000 hours at full load and 25℃ambient conditions TOTAL POWER, INT. TEL: 877-646-0900 FAX: 978-453-7395 E-mail: [email protected] http://www.total-power.com -1- TOTAL POWER TPS25LB MODEL SWITCHING MODE 25W LOW COST BOX TYPE OUTPUT ADJUSTMENT MAXIMUM OUTPUT PEAK OUTPUT MINIMUM OUTPUT TOTAL RIPPLE & NOISE PEAK OUTPUT VOLTAGE RANGE CURRENT CURRENT(NOTE1) CURRENT REGULATION(NOTE3) %P-P(NOTE2) POWER(NOTE1) SI NGLE OUTPUT MODEL SELECTION CHART TPS25LB-10 +5V ±10% Typical 5A 6.5A 0A ±3% ±1% 33W Typical TPS25LB-11 +12V ±10% Typical 2.08A 2.7A 0A ±3% ±1% 33W Typical TPS25LB -12 +15V ±10% Typical 1.66A 2.1A 0A ±3% ±1% 33W Typical TPS25LB -13 +24V ±10% Typical 1.04A 1.3A 0A ±3% ±1% 33W Typical TPS25LB -14 +48V ±10% Typical 0.52A 0.6A 0A ±3% ±1% 33W Typical TPS25LB -15 +3.3V ±10% Typical 5A 6.5A 0A ±5% ±1.5% 22W Typical DUAL OUTPUT MODEL SELECTION CHART TPS25LB -20 TPS25LB -21 TPS25LB -22 TPS25LB -23 TPS25LB -24 TPS25LB -25 TPS25LB -26 +5 V ±10% Typical 3.75A 4.8A 0.38A ±5% ±1% +12V Fixed 0.58A 0.7A 0.06A ±5% ±1% +5 V ±10% Typical 3.75A 4.8A 0.38A ±5% ±1% +24V Fixed 0.34A 0.2A 0.03A ±5% ±1% +5 V ±10% Typical 3.75A 4.8A 0.38A ±5% ±1% - 5V Fixed 1.25A 1.6A 0.13A ±10% ±1% +12V ±10% Typical 1.08A 1.4A 0.11A ±5% ±1% - 12V Fixed 1.08A 1.4A 0.11A ±10% ±1% +15V ±10% Typical 0.83A 1.0A 0.08A ±5% ±1% - 15V Fixed 0.83A 1.0A 0.08A ±10% ±1% +3.3V ±10% Typical 5A 6.5A 0.5A ±5% ±1.5% +5V Fixed 2A 2.6A 0.2A ±5% ±1% +5V ±10% Typical 1A 1.0A 0.1A ±5% ±1% +48V Fixed 0.5A 1.0A 0.05A ±10% ±1% 33W Typical 33W Typical 33W Typical 33W Typical 33W Typical 33W Typical 33W Typical TRIPLE OUTPUT MODEL SELECTION CHART TPS25LB -30 TPS25LB -31 TPS25LB -32 TPS25LB -33 TPS25LB -34 TPS25LB -35 TPS25LB -36 TPS25LB -37 TPS25LB -38 + 5V ±10% Typical 3.33A 4.3A 0.33A ±5% ±1% +12V Fixed 0.42A 0.5A 0.04A ±5% ±1% -5V Fixed 0.83A 1.0A 0.08A ±10% ±1% + 5V ±10% Typical 3.33A 4.3A 0.33A ±5% ±1% +12V Fixed 0.42A 0.5A 0.04A ±5% ±1% -12V Fixed 0.33A 0.4A 0.03A ±10% ±1% + 5V ±10% Typical 3.33A 4.3A 0.33A ±5% ±1% +15V Fixed 0.33A 0.4A 0.03A ±5% ±1% -15V Fixed 0.33A 0.4A 0.03A ±10% ±1% +5V ±10% Typical 2.5A 3.2A 0.25A ±5% ±1% -5V Fixed 0.83A 1.0A 0.08A ±5% ±1% +15V Fixed 0.58A 0.7A 0.06A ±10% ±1% + 5V ±10% Typical 2.5A 3.2A 0.25A ±5% ±1% -12V Fixed 0.4A 0.5A 0.04A ±5% ±1% +15V Fixed 0.5A 0.6A 0.05A ±10% ±1% + 5V ±10% Typical 2.5A 3.2A 0.25A ±5% ±1% -12V Fixed 0.42A 0.5A 0.04A ±5% ±1% +24V 0.33A 0.4A 0.03A 1A 3.2A 0.1A ±10% ±5% ±1% + 5V Fixed ±10% Typical +12V Fixed 1.5A 2.0A 0.15A ±5% ±1% -12V Fixed 0.4A 0.5A 0.04A ±1% 33W Typical 33W Typical 33W Typical 33W Typical 33W Typical ±1% +5V ±10% Typical 2.5A 3.2A 0.25A ±10% ±5% +12V Fixed 0.42A 0.5A 0.04A ±5% ±1% +24V Fixed 0.33A 0.4A 0.03A ±1% +5V ±10% Typical 1.67A 2.1A 0.17A ±10% ±5% +12V Fixed 0.83A 1.1A 0.08A ±5% ±1% 33W Typical ±1% 33W Typical ±1% Fixed ±10% ±1% +48V 0.17A 0.2A 0.02A NOTES: 1) Peak loads for lasting <30 seconds with a maximum 10% duty cycle are acceptable. Please contact us if need special peak load. 2) Maximum peak to peak noise expressed as a percentage of output voltage, 20MHz bandwidth,0.1μF and 47μF Cap. on outputs. 3) Loading test conditions are set for all outputs at minimum, middle and maximum of loads. Special cross loading requirement is welcomed. 4) Detailed engineering specification of each model is available for inquiry. 5) Special output voltage/current inquiry is welcomed. 6) Specifications subject to change without notice. TOTAL POWER, INT. TEL: 877-646-0900 FAX: 978-453-7395 E-mail: [email protected] http://www.total-power.com -2- 33W Typical 33W Typical