TOTAL POWER INT'L TPS100 SWITCHING MODE 90W U CHANNEL POWER SUPPLIES KEY FEATURES *Universal input *Built-in EMI filter *Optional remote sense on main output *Optional constant current charger *Optional±12VDC/±24VDC/±48VDC input *Optional cover *Optional constant current change (for single output) APPLICATIONS *Telecommunications/Business machines *Computer peripherals/Medical instruments *Test & industrial equipments ELECTRICAL SPECIFICATIONS EMI & EMC INPUT *FCC part 15, Class B *CISPR 22 / EN55022, Class B *VCCI ,Class 2 *CE, EN61000-3-2 (Class A) and –3 ; EN61000-4-2, -3 , -4 , -5 , -6 and -11 *Input range-----------90~264 VAC, universal *Frequency------------47~63Hz *Inrush current--------38A typical, Cold start @25℃,115VAC *Efficiency------------65%~85% typical at full load *EMI filter------------ FCC Class B conducted, CISPR 22 Class B conducted, EN55022 class B Conducted *Line regulation----- +/- 0.5% typical OUTPUT *Maximum power----90W convection (Refer next page) *Hold-up time --------10ms typical at full load and 115 VAC nominal line *Overload protection-Short circuit protection *Overvoltage protection ------------Main output 20% to 40% above nominal output *Ripple/Noise -------- +/- 1% Max. @full load (Optional +/-0.5 % per inquiry) Power Derating Curve 120W 90W Output Power 60W (Watts) 30W Natural Convection Cooling 45W 0W 0 10 20 30 40 50 60 70 Ambient Temperature( ° C) SAFETY APPROVAL *UL1950 / c UL *Optional CSA 22.2, LEVEL 3 (COMPLY WITH) *TUV EN60950 *Optional UL 2601(EMI Class A)(COMPLY WITH) ENVIRONMENTAL *Operating temperature : 0 to 50℃ambient; derate each output at 2.5% per degree from 50℃to 70℃ *Humidity: Operating; non-condensing, 5% to 95% *Vibration : 10~55 Hz at 1G 3 minutes period, 30 minutes along X, Y and Z axis *Storage temperature: -40 to 85℃ *Temperature coefficient: +/- 0.05% per degree C *MTBF demonstrated: >100,000 hours at full load and 25℃ambient conditions TOTAL POWER INT'L. TEL:877-646-0900 FAX:978-453-7395 E-mail:[email protected] http://www.total-power.com -1- TPS100 MODEL SWITCHING MODE 90W U CHANNEL POWER SUPPLIES OUTPUT ADJUSTMENT MAXIMUM OUTPUT PEAK OUTPUT MINIMUM OUTPUT TOTAL RIPPLE & NOISE PEAK OUTPUT VOLTAGE RANGE CURRENT CURRENT(NOTE1) CURRENT REGULATION(NOTE3) %P-P(NOTE2) POWER(NOTE1) SINGLE OUTPUT MODEL SELECTION CHART TPS100-10 +5V ±10% Typical 18A 29.7A 0A ±3% ±1% 150W Typical TPS100-11 +12V ±10% Typical 7.5A 12.4A 0A ±3% ±1% 150W Typical TPS100-12 +15V ±10% Typical 6A 9.9A 0A ±3% ±1% 150W Typical TPS100-13 +24V ±10% Typical 3.75A 6.2A 0A ±3% ±1% 150W Typical TPS100-14 +48V ±10% Typical 1.875A 3.1A 0A ±3% ±1% 150W Typical TPS100-15 +13.5V ±10% Typical 6.66A 10.9A 0A ±3% ±1% 150W Typical TPS100-16 +56V ±10% Typical 1.6A 2.6A 0A ±3% ±1% 150W Typical TPS100-17 +18V ±10% Typical 5A 2.6A 0A ±3% ±1% 150W Typical TPS100-18 +3.3V ±10% Typical 25A 41.3A 0A ±5% ±1.5% 150W Typical 16.5A 6.9A 16.5A 3.6A 16.5A 16.5A 6.9A 6.9A 5.6A 5.6A 28A 1.6A 1.6A 3.3A 1A 0.42A 1A 0.22A 1A 1A 0.42A 0.42A 0.34A 0.34A 1.7A 0.1A 0.1A 0.2A ±5% ±5% ±5% ±5% ±5% ±5% ±5% ±5% ±5% ±5% ±5% ±5% ±5% ±5% ±1% ±1% ±1% ±1% ±1% ±1% ±1% ±1% ±1% ±1% ±1.5% ±1% ±1% ±1% DUAL OUTPUT MODEL SELECTION CHART TPS100-20 TPS100-21 TPS100-22 TPS100-23 TPS100-24 TPS100-25 TPS100-26 +5 V +12V +5 V +24V +5 V -5V +12V - 12 V +15 V - 15 V +3.3V +12 V +5V +48V ±10% Typical Fixed ±10% Typical Fixed ±10% Typical Fixed ±10% Typical Fixed ±10% Typical Fixed ±10% Typical Fixed ±10% Typical Fixed 10A 4.2A 10A 2.2A 10A 10A 4.2A 4.2A 3.4A 3.4A 17A 1A 1A 2A 150W Typical 150W Typical 150W Typical 150W Typical 150W Typical 150W Typical 150W Typical TRIPLE OUTPUT MODEL SELECTION CHART TPS100-30 TPS100-31 TPS100-32 TPS100-33 TPS100-34 TPS100-35 TPS100-36 TPS100-37 TPS100-38 + 5V ±10% Typical 10A 16.5A 1A ±5% ±1% +12V Fixed 4A 6.6A 0.4A ±5% ±1% -5V Fixed 0.6A 1A 0.06A ±10% ±1% + 5V ±10% Typical 10A 16.5A 1A ±5% ±1% +12V Fixed 4A 6.6A 0.4A ±5% ±1% -12V Fixed 0.6A 1A 0.06A ±10% ±1% + 5V ±10% Typical 10A 16.5A 1A ±5% ±1% +15V Fixed 2.8A 4.6A 0.28A ±5% ±1% -15V Fixed 0.6A 1A 0.06A ±10% ±1% + 5V ±10% Typical 14A 23.1A 1.4A ±5% ±1% +15V Fixed 2A 3.3A 0.2A ±5% ±1% -5V Fixed 0.5A 0.8A 0.05A ±10% ±1% + 5V ±10% Typical 13A 21.5A 1.3A ±5% ±1% +15V Fixed 2A 3.3A 0.2A ±5% ±1% -12V Fixed 0.6A 1A 0.06A ±10% ±1% +5V ±10% Typical 9A 14.9A 0.9A ±5% ±1% +24V Fixed 2A 3.3A 0.2A ±5% ±1% -12V Fixed 0.6A 1A 0.06A ±10% ±1% + 5V ±10% Typical 9A 14.9A 0.9A ±5% ±1% +12V Fixed 3.5A 5.8A 0.35A ±5% ±1% - 12V Fixed 0.6A 1A 0.06A ±10% ±1% + 5V +12V ±10% Typical 9A 3.5A 14.9A 5.8A 0.9A 0.35A ±5% Fixed ±5% ±1% ±1% +24V Fixed 0.6A 1A 0.06A ±10% ±1% + 5V +12V ±10% Typical 6A 2A 9.9A 3.3A 0.6A 0.2A ±5% Fixed ±5% ±1% ±1% +48V Fixed 1A 1.6A 0.1A ±10% ±1% TOTAL POWER INT'L. TEL:877-646-0900 FAX:978-453-7395 E-mail:[email protected] http://www.total-power.com -2- 150W Typical 150W Typical 150W Typical 150W Typical 150W Typical 150W Typical 150W Typical 150W Typical 150W Typical TPS100 MODEL SWITCHING MODE 90W U CHANNEL POWER SUPPLIES OUTPUT ADJUSTMENT MAXIMUM OUTPUT PEAK OUTPUT MINIMUM OUTPUT TOTAL RIPPLE & NOISE PEAK OUTPUT VOLTAGE RANGE CURRENT CURRENT(NOTE1) CURRENT REGULATION(NOTE3) %P-P(NOTE2) POWER(NOTE1) ±1% QUAD OUTPUT MODEL SELECTION CHART TPS100-40 TPS100-41 TPS100-42 TPS100-43 TPS100-44 TPS100-45 TPS100-46 + 5V ±10% Typical 10A 16.5A 1A ±5% +12V Fixed 3.5A 5.8A 0.35A ±5% ±1% - 12V Fixed 0.5A 0.8A 0.05A ±10% ±1% -5V Fixed 0.5A 0.8A 0.05A ±10% ±1% + 5V ±10% Typical 10A 16.5A 1A ±5% ±1% +12V Fixed 3A 5A 0.3A ±5% ±1% - 12V Fixed 1A 1.6A 0.1A ±10% ±1% -5V Fixed 1A 1.6A 0.1A ±10% ±1% + 5V ±10% Typical 10A 16.5A 1A ±5% ±1% +12V Fixed 2A 3.3A 0.2A ±5% ±1% - 15V Fixed 1A 1.6A 0.1A ±10% ±1% +15V Fixed 1A 1.6A 0.1A ±10% ±1% + 5V ±10% Typical 6A 9.9A 0.6A ±5% ±1% +12V Fixed 2.5A 4.1A 0.25A ±5% ±1% -15V Fixed 1A 1.6A 0.1A ±10% ±1% - 12V Fixed 1A 1.6A 0.1A ±10% ±1% + 5V ±10% Typical 6A 9.9A 0.6A ±5% ±1% +12V Fixed 1A 1.6A 0.1A ±5% ±1% - 12V Fixed 1A 1.6A 0.1A ±10% ±1% +48V Fixed 1A 1.6A 0.1A ±10% ±1% + 5V ±10% Typical 6A 9.9A 0.6A ±5% ±1% +12V Fixed 2A 3.3A 0.2A ±5% ±1% - 12V Fixed 1A 1.6A 0.1A ±10% ±1% +24V Fixed 1.5A 2.5A 0.15A ±10% ±1% + 5V ±10% Typical 2.5A 4.1A 0.25A ±5% ±1% +12V Fixed 1A 1.6A 0.1A ±5% ±1% - 12V Fixed 2A 3.3A 0.2A ±10% ±1% 150W Typical 150W Typical 150W Typical 150W Typical 150W Typical 150W Typical 150W Typical Fixed ±10% ±1% +36V 1.5A 2.5A 0.15A NOTES: 1) Peak loads for lasting <30 seconds with a maximum 10% duty cycle are acceptable. Please contact us if need special peak load. 2) Maximum peak to peak noise expressed as a percentage of output voltage, 20MHz bandwidth, 0.1μF and 47μF Cap. on outputs. 3) Loading test conditions are set for all outputs at minimum, middle and maximum of loads. Special cross loading requirement is welcomed. 4) Detailed engineering specification of each model is available for inquiry. 5) Special output voltage/current inquiry is welcomed. 6) Specifications subject to change without notice. 7) 25% derated if 24 VDC input version; 50% derated if 12 VDC input version; 25% derated if additional cover. TOTAL POWER INT'L TEL:877-646-0900 FAX:978-453-7395 E-mail:[email protected] http://www.total-power.com -3-