Version 1.6 File:TFS190C.doc VI TELEFILTER 07.08.2002 Filter specification TFS 190 C 1/5 Measurement condition Ambient temperature TA: Input power level: Terminating impedance*: °C dBm 610 Ω // -10.4 pF 560 Ω // -10,3 pF 23 0 input output Characteristics Remark: Reference level for the relative attenuation arel of the TFS 190 C is the minimum of the pass band attenuation amin. The minimum of the pass band attenuation amin is defined as the insertion loss ae.The nominal frequency fN is fixed at 190,0 MHz without tolerance. The values of the pass band ripple and the relative attenuation arel are guaranteed in the whole operating temperature range. The frequency shift of the filter in the operating temperature range is included in the measurement tolerance scheme. Data typ. value Insertion loss (Reference level) ae = amin 8,2 Nominal frequency fN - Pass band PB Relative attenuation arel fN fN ± .... 2,0 fN - 5,0 fN - 12,0 fN + fN ± 2 MHz MHz ... fN ± 2,5 MHz MHz ... fN - 12 MHz 1 dB dB - tolerance / limit max 12 dB 190 MHz fN ± 2 MHz max 2 dB max 5 dB 36 dB min 32 dB MHz 40 dB min 36 dB 5,0 MHz ... fN - 190 MHz ... fN + 12 MHz 36 dB min 32 dB fN + 12,0 MHz ... fN +270 MHz 45 dB min 36 dB °rms max 4 °rms max 10 dBm Phase variation fN ± 2,5 MHz 1,2 Input power level - - 30 °C ... + 85 °C Operating temperature range - 55 °C ... + 125 °C Storage temperature range Temperature coefficient of frequency TCf** -25 ppm/K - *) The terminating impedances depend on parasitics and q-values of matching elements and the board used, and are to be understood as reference values only. Should there be additional questions do not hesitate to ask for an application note or contact our design team. **) ∆fc(Hz) = Tcf(ppm/K) x (T - TA) x fCTA (MHz) generated: checked / approved: VI TELEFILTER Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. Version 1.6 File:TFS190C.doc VI TELEFILTER 07.08.2002 Filter specification TFS 190 C 2/5 Construction, pin configuration and 50 Ω - matching network (All dimensions in mm) 5.0 SQ 7 +0.15 -0.1 5 190 C P32 1 3 Date code Pin 1 Pin 2 Pin 3 Pin 4 Output Ground Input Ground Pin 5 Pin 6 Pin 7 Pin 8 date code: M N P ... Input RF return Ground Output Ground year + week 2000 2001 2002 50 Ohm Test circuit L1 Input, 50 Ohm 3 1 SAW C1 C2 7 5 50 Ohm - 50 Ohm L2 Output, 50 Ohm L3 2,4,6,8 VI TELEFILTER Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. Version 1.6 File:TFS190C.doc VI TELEFILTER 07.08.2002 Filter specification TFS 190 C 3/5 Stability Characteristics After the following tests, the filter shall meet the whole specification: 1. Shock: 500g, 18 ms, half sine wave, 3 shocks each plane; DIN IEC 68 T2 - 27 2. Vibration: 10 Hz to 500 Hz, 0,35 mm or 5g respectively, 1 octave per min, 10 cycles per plan, 3 plans; DIN IEC 68 T2 - 6 3. Change of temperature -55 °C to 125°C / 30 min. each / 10 cycles DIN IEC 68 part 2 – 14 Test N 4. Resistance to solder heat (reflow): reflow possible: twice max.; for temperature conditions, please refer to the attached "Air reflow temperature conditions" on page 4 Packing Tape & Reel: IEC 286 - 3, with exception of value for N and minimum bending radius; tape type II, embossed carrier tape with top cover tape on the upper side; max. pieces of filters per reel: reel of empty components at start: reel of empty components at start including leader: trailer Tape (all dimensions in mm) W : 12 ± 0,3 Po : 4 ± 0,1 Do : 1,5 + 0,1 E : 1,75 ± 0,1 F : G (min) : P2 : P1 : EMBOSSED CARRIER TAPE Do Po P2 E Ao 5,5 ± 0,05 0,75 2 8 ± 0,05 3000 min 300 mm min 500 mm min 300 mm F D1 CT W Bo ± 0,1 G D1(min) : 1,5 Ao : 5,3 ± 0,1 Bo : 5,3 ± 0,1 CT : 9,5 ± 0,1 P1 COVER TAPE W 2 Reel (all dimensions in mm): A : W1 : W2 (max) : 330 12,4 + 0,2 18,4 N (min) : 50 C : 13 ± 0,2 A C N W 1 The minimum bending radius is 45 mm. The mounting surface of the filters faces the bottom side of the embossed carrier tape. Markings on the filters can be read if the upper side of the carrier tape is regarded with the sprocket holes on its right. VI TELEFILTER Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. Version 1.6 File:TFS190C.doc VI TELEFILTER 07.08.2002 Filter specification TFS 190 C 4/5 Air reflow temperature conditions 1st and 2nd air reflow profile Name: Temperature: Time: pre-heating periods 150 °C - 170 °C 60 sec. - 90 sec. main-heating periods over 200 °C 20 sec. - 25 sec. peak temperature 255 °C ± 5 °C Chip-mount air reflow profile 260 240 220 200 temperature / °C 180 160 140 120 100 80 60 40 20 0 0 20 40 60 80 100 120 140 160 180 200 220 240 time / sec. Table for temperature vs. time during the air reflow process Tolerance of temperatures: ± 5 °C time / sec. 0 10 20 30 40 50 60 70 80 90 100 110 120 130 temperature / °C 23 34 46 60 80 103 121 134 143 150 154 156 158 159 time / sec. 140 150 160 170 180 190 195 200 205 210 215 220 230 240 temperature / °C 160 161 164 170 180 205 230 255 230 205 180 165 140 120 VI TELEFILTER Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. Version 1.6 File:TFS190C.doc VI TELEFILTER Filter specification 07.08.2002 TFS 190 C 5/5 History Version Reason of Changes Name Date 1.0 Generation of specification according to customer requirements Herrler 25.07.2001 1.1 change of pinning according to customer proposal Steiner 20.09.2001 1.2 new Development specification Change of relative rejection and phase variation in pass band Dr. Sabah 08.03.2002 1.3 Add of rejection typical values Dr. Sabah 15.03.2002 1.4 Add of typical values and change to filter specification Dr. Sabah 26.04.2002 1.5 correct relative attenuation Dr. Sabah 29.05.2002 1.6 changing typical values of insertion loss, relative attenuation and temperature coefficient of frequency Pfeiffer 07.08.2002 VI TELEFILTER Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.