Filename: tfs225e.doc version 1.2 VI TELEFILTER Filter specification 25.04.2003 TFS 225E 1/5 Measurement condition Ambient temperature: Input power level: Terminating impedances at fc *: 23 0 input: output: °C dBm 940 Ω // -5,7 pF 940 Ω // -5,7 pF Characteristics Remark: The reference level for the relative attenuation arel of TFS 225E is the minimum of the pass band attenuation amin. This value is defined as the insertion loss ae. The centre frequency fc is the arithmetic mean value of the upper and lower frequencies at the 1 dB filter attenuation level relative to the insertion loss ae. The given values for the relative attenuation arel and the group delay ripple have to be reached at the frequencies given below, even if the centre frequency fc is shifted due to the temperature coefficient of frequency TCf in the operating temperature range and due to a production tolerance for the centre frequency fc. Data typ. value Insertion loss ae = amin 6,5 Nominal frequency fN - Centre frequency fc 225 Relative attenuation arel fN - 0,2 MHz ... fN + 0,2 MHz fN ± fN ± 0,6 1,2 1 1,8 7 1,2 1,8 1,8 7 1 fN + fN + kHz MHz MHz MHz MHz ... fN ± ... fN ± ... fN ... fN + ... MHz MHz MHz MHz GHz Group delay ripple in fN - 200 kHz ... fN + 200 kHz 0,5 dB limit min. max. 4,5 dB 8 dB 225 MHz MHz - dB max. 1 dB 15 27 35 35 52 dB dB dB dB dB min. min. min. min. min. 8 20 30 30 45 dB dB dB dB dB 85 ns max. 350 ns Operating temperature range - - 20 °C...+ 80 °C Storage temperature range - - 35 °C.. + 85 °C Temperature coefficient TC ** - 0,04 ppm/K² Frequency inversion temperature T0 35 Input power level - - °C max. + 10 dBm *) The terminating impedances depend on parasitics and q-values of matching elements and the board used, and are to be understood as reference values only. Should there be additional questions, do not hesitate to ask for an application note or contact our design team **) ∆f(Hz) = TCf(ppm/K) x (T-T0)² x fTo(MHz) generated: checked / approved: TELEFILTER GmbH Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. Filename: tfs225e.doc version 1.2 VI TELEFILTER 25.04.2003 Filter specification TFS 225E 2/5 Construction and pin connection (All dimensions in mm) 9 9,3 Max. 6 7 TFS 225 E 10 2 3 Date code 1,8 Max. 2,54 ±0,1 5 4 R17 1 1 2 3 4 5 6 7 8 9 10 date code N P R ... 2,54 ±0,12,54 ±0,1 0,10 ° 60 1 2 3 4 10 9 5 8 7 0,8 7,1 ground ground ground output output rf return ground ground ground input input rf return year + week 2001 2002 2003 2,8 5,0Max. 8 6 50 Ω test circuit L1 L3 9 Input 50 Ohm 4 Output 50 Ohm SAW L2 L4 1, 2, 3, 5, 6, 7,8,10 TELEFILTER GmbH Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. Filename: tfs225e.doc version 1.2 VI TELEFILTER 25.04.2003 Filter specification TFS 225E 3/5 Stability characteristics After the following tests the filter shall meet the whole specification: 1. Shock: 500g, 18 ms, half sine wave, 3 shocks each plane; DIN IEC 68 T2 - 27 2. Vibration: 10 Hz to 500 Hz, 0,35 mm or 5g respectively, 1 octave per min, 10 cycles per plan, 3 plans; DIN IEC 68 T2 - 6 3. Change of temperature: -55 °C to 125°C / 30 min. each / 10 cycles DIN IEC 68 part 2 – 14 Test N 4. Resistance to solder heat (reflow): reflow possible: twice max.; for temperature conditions refer to the attached "Air reflow temperature conditions" on page 4; Packing Tape & Reel: IEC 286 - 3, with exception of value for N and minimum bending radius; tape type II, embossed carrier tape with top cover tape on the upper side; max. pieces of filters per reel: reel of empty components at start: reel of empty components at start including leader: trailer Tape (all dimensions in mm) W : 16 ± 0,3 Po Do E : 4 ± 0,1 : : 1,5 + 0,1 1,75 ± 0,1 F : 7,5 ± 0,1 3000 min 300 mm min 500 mm min 300 mm EMBOSSED CARRIER TAPE Po Do P2 E Ao G (m in) : 0,60 P2 : P1 : D1(m in) : 2 8 1,5 Ao : 5,30 Bo : 9,70 ± 0,1 CT : 13,5 ± 0,1 F D1 ± 0,1 ± 0,1 W Bo CT G ± 0,1 P1 COVER TAPE W 2 Reel (all dimensions in mm): A : W1 : W 2 (max) : 330 16,40 +2,0 22,4 N (min) : 50 C : 13,0 + 0,5/-0.2 A C N W 1 The minimum bending radius is 45 mm. The mounting surface of the filters faces the bottom side of the embossed carrier tape. Markings on the filters can be read if the upper side of the carrier tape is regarded with the sprocket holes on its right. TELEFILTER GmbH Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. Filename: tfs225e.doc version 1.2 VI TELEFILTER 25.04.2003 Filter specification TFS 225E 4/5 Air reflow temperature conditions 1st and 2nd air reflow profile Name: Temperature: Time: pre-heating periods 150 °C - 170 °C 60 sec. - 90 sec. main-heating periods over 200 °C 20 sec. - 25 sec. peak temperature 255 °C ± 5 °C Chip-mount air reflow profile 260 240 220 200 temperature / °C 180 160 140 120 100 80 60 40 20 0 0 20 40 60 80 100 120 140 160 180 200 220 240 time / sec. Table for temperature vs. time during the air reflow process Tolerance of temperatures: ± 5 °C time / sec. 0 10 20 30 40 50 60 70 80 90 100 110 120 130 temperature / °C 23 34 46 60 80 103 121 134 143 150 154 156 158 159 time / sec. 140 150 160 170 180 190 195 200 205 210 215 220 230 240 temperature / °C 160 161 164 170 180 205 230 255 230 205 180 165 140 120 TELEFILTER GmbH Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. Filename: tfs225e.doc VI TELEFILTER version 1.2 Filter specification 25.04.2003 TFS 225E 5/5 History Version Reason of Changes Name Date 1.0 - generate specification Pfeiffer 13.09.2002 1.1 - terminating impedance added (preliminary values) - typical values added Pfeiffer 07.02.2003 1.2 - terminating impedance fixed Pfeiffer 25.04.2003 TELEFILTER GmbH Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.