VECTRON TFS1220

TFS1220.doc
version 1.4
VI TELEFILTER
21.08.02
Filter specification
TFS 1220
1/5
Measurement condition
Ambient temperature:
23 °C
Input power level:
0 dBm
Terminating impedances*:
input: 95 Ω // -0.3 pF
output: 95 Ω // -0.3 pF
Characteristics
Remark:
Reference level for the relative attenuation arel of the TFS 1220 is the minimum of the pass band attenuation amin. The minimum of the pass
band attenuation amin is defined as the insertion loss ae. The centre frequency fc is the arithmetic mean value of the upper and lower frequencies
at the 3 dB filter attenuation level relative to the insertion loss ae. The nominal frequency fN is fixed at 1220,0 MHz without tolerance. The given
values for the relative attenuation arel have to be reached at the frequencies given below even if the centre frequency fc is shifted due to the
temperature coefficient of frequency TCf in the operating temperature range and due to a production tolerance for the centre frequency fc
Data
typ. value
Insertion loss
ae = amin
4,0
dB
Variation/ Limitation
max.
6,0
dB
(Reference level)
Nominal frequency
fN
-
Centre frequency
fc
1220
Passband ripple
(P-P)
within fN ± 100 KHz
Group delay ripple within fN ± 100 KHz
43,0
Relative attenuation
fN
....... fN ±
0,1 MHz
fN ± 4 MHz ....... fN ±
5 MHz
fN ± 5 MHz ....... fN ±
6 MHz
fN ± 6 MHz ....... fN ±
20 MHz
fN + 20 MHz ....... fN + 180 MHz
fN - 20 MHz ....... fN - 1150 MHz
arel
Temperature coefficient of frequency
TCf
Frequency inversion temperature
0,40
0,40
25,0
28,0
37,0
35,0
45,0
1220
MHz
MHz
dB
max
1,0
dB
ns
max. 100
ns
dB
max.
1
dB
dB
dB
dB
dB
dB
min.
min.
min.
min.
min.
10
12
14
30
30
dB
dB
dB
dB
dB
-0,050 ppm/K²
40 °C.
Operating temperature range
- 40 °C ... + 85 °C
Storage temperature range
- 45 °C ... + 90 °C
Input power level
max.
10
dBm
*) The terminating impedances depend on parasitics and q-values of matching elements and the board used, and are to be understood as
reference values only. Should there be additional questions do not hesitate to ask for an application note or contact our design team.
generated
:
checked / approved :
VI TELEFILTER
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
TFS1220.doc
version 1.4
VI TELEFILTER
21.08.02
Filter specification
TFS 1220
2/5
Construction, pin configuration and 50 Ω - matching network
(All dimensions in mm)
5
7
1220
1,78
SQ 3,81
+ 0,2 / -0,1
1,78
0,6
P34
1
0,1
Date code
Pin 1
Pin 2
Pin 3
Pin 4
3
Input
Ground
Ground
Package Ground
2,54
1,2 Max.
Pin 5
Pin 6
Pin 7
Pin 8
date code:
M
N
P
...
Output
Ground
Ground
Package ground
year + week
2000
2001
2002
50 Ohm Test circuit
L1
Input,
50 Ohm
1
C1
5
SAW
L2
C2
Output,
50 Ohm
2,3,4,6,7,8
VI TELEFILTER
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information
TFS1220.doc
version 1.4
VI TELEFILTER
21.08.02
Filter specification
TFS 1220
3/5
Stability Characteristics
After the following tests the filter shall meet the whole specification:
1. Shock:
500g, 18 ms, half sine wave, 3 shocks each plane;
DIN IEC 68 T2 - 27
2. Vibration:
10 Hz to 500 Hz, 0,35 mm or 5g respectively, 1 octave per min, 10 cycles per plan, 3 plans;
DIN IEC 68 T2 - 6
3. Change of
temperature:
-55 °C to 125°C / 30 min. each / 10 cycles
DIN IEC 68 part 2 – 14 Test N
4. Resistance to
solder heat (reflow):
reflow possible: twice max.;
for temperature conditions, please refer to the attached "Air reflow temperature conditions" on page
4;
Packing
Tape & Reel:
IEC 286 - 3, with exception of value for N and minimum bending radius;
tape type II, embossed carrier tape with top cover tape on the upper side;
max. pieces of filters per reel:
reel of empty components at start:
reel of empty components at start including leader:
trailer
Tape (all dimensions in mm)
W
Po
Do
:
:
:
12
4
1,5
1,75 ± 0,1
5,5 ± 0,05
0,75
2 ± 0,05
P1
:
D1(min) :
Ao
:
8
± 0,1
1,5
4,3 ± 0,1
Bo
CT
4,3
9,5
:
:
EMBOSSED CARRIER TAPE
± 0,3
± 0,1
+ 0,1
E
:
F
:
G (min) :
P2
:
3000
min 300 mm
min 500 mm
min 300 mm
Do
Po
P2
E
Ao
F
D1
CT
W
Bo
G
P1
± 0,1
± 0,1
COVER TAPE
W2
Reel (all dimensions in mm):
A
:
W1
:
330
12,4 + 2,0
W 2 (max) :
18,4
N (min)
:
50
C
:
13
A
-+0,5/ -0,2
C
N
W 1
The minimum bending radius is 45 mm. The mounting surface of the filters faces the bottom side of the embossed carrier tape.
Markings on the filters can be read if the upper side of the carrier tape is regarded with the sprocket holes on its right.
VI TELEFILTER
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information
TFS1220.doc
version 1.4
VI TELEFILTER
21.08.02
Filter specification
TFS 1220
4/5
Air reflow temperature conditions
1st and 2nd air reflow profile
Name:
Temperature:
Time:
pre-heating periods
150 °C - 170 °C
60 sec. - 90 sec.
main-heating periods
over 200 °C
20 sec. - 25 sec.
peak temperature
255 °C ± 5 °C
Chip-mount air reflow profile
260
240
220
200
temperature / °C
180
160
140
120
100
80
60
40
20
0
0
20
40
60
80
100
120
140
160
180
200
220
240
time / sec.
Table for temperature vs. time during the air reflow process
Tolerance of temperatures: ± 5 °C
time / sec.
0
10
20
30
40
50
60
70
80
90
100
110
120
130
temperature / °C
23
34
46
60
80
103
121
134
143
150
154
156
158
159
time / sec.
140
150
160
170
180
190
195
200
205
210
215
220
230
240
temperature / °C
160
161
164
170
180
205
230
255
230
205
180
165
140
120
VI TELEFILTER
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information
TFS1220.doc
version 1.4
VI TELEFILTER
21.08.02
Filter specification
TFS 1220
5/5
History
Version
Reason of Changes
Name
Date
1.0
- Generation of development specification according to customer specification
Dr. Sabah
26.03.2002
1.1
- changing range of storage temperature
- reducing maximum of insertion loss to 4 dB
- changing relativ attenuation
Pfeiffer
05.04.2002
1.2
- change insertion loss and relative attenuation
Dr. Sabah
18.07.2002
1.3
- Preliminary Specification; add of typical values and terminating impedance
Dr. Sabah
19.08.2002
1.4
- Filter Specification; add of terminating impedance and frequency
inversion temperature
Dr. Sabah
21.08.2002
VI TELEFILTER
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information