SSDI STA60K167S

STA60K79S thru
STA60K100S
Solid State Devices, Inc.
14701 Firestone Blvd * La Mirada, Ca 90638
Phone: (562) 404-4474 * Fax: (562) 404-1773
[email protected] * www.ssdi-power.com
60,000 WATTS
PEAK PULSE POWER
79 – 1000 VOLTS
HIGH VOLTAGE BIDIRECTIONAL
TRANSIENT VOLTAGE SUPPRESSOR
Designer’s Data Sheet
•
•
•
•
•
•
FEATURES:
79-1000 Volt Bidirectional
Smaller than 60KS200C Types
Hermetically Sealed
Meets all environmental requirements of MIL-PRF-19500
Custom Configurations Available
TX and TXV Screening Available
•
•
•
APPLICATIONS:
Protection of Voltage Sensitive Components
Protection Against Power Interruption
Lightning Protection
Maximum Ratings (note 2)
56 - 750
Volts
PD
400
Watts
PPP
60,000
Watts
Stand Off Voltage
VRWM
Steady State Power Dissipation
Peak Pulse Power @ 1.0 msec
Peak Pulse Power and Steady
State Power Derating
SEE GRAPH
Peak Pulse Power and Pulse
Width
SEE GRAPH
Operating and Storage
Temperature
-65°C to +175°C
Note:
SSDI Transient Suppressors offer standard Breakdown Voltage Tolerances
of + 10% (A) and + 5% (B). For other Voltage and Voltage Tolerances,
contact SSDI's Marketing Department
PEAK PULSE POWER
(% Rated 25°C Power)
PEAK PULSE POWER VS. TEMPERATURE DERATING CURVE
Package shown is standard configuration. SSDI can custom
design your module with terminals that meet your unique
design criteria. Additionally, SSDI can package these
devices with an irregular footprint or offset mounting
positions. This data sheet is meant to serve as an example of
SSDI's Transient Protection Module Capabilities. For
custom configurations, please contact SSDI's Marketing
Department.
AMBIENT TEMPERATURE (°C)
NOTE: All specifications are subject to change without notification.
SCD's for these devices should be reviewed by SSDI prior to release.
DATA SHEET #: T00014C
DOC
Solid State Devices, Inc.
STA60K79S thru
STA60K100S
14701 Firestone Blvd, La Mirada, Ca 90638
Phone: (562) 404-4474
Fax: (562) 404-1773
[email protected]
www.ssdi-power.com
ELECTRICAL CHARACTERISTICS (note 2)
Break Down (note 1)
Part
Number
(note 4)
Max Reverse Stand Off
Peak Pulse Clamping
Max
Temperature
Nominal
Voltage
Test
Current
Voltage
VBR
@IBRT
VRWM
IR@VRWM
VC
IPP
IRM
TC
Volts
mA
Volts
µA
Volts
Amps
Amps
%/°C
STA60K79S
STA60K89S
STA60K98S
STA60K107S
STA60K110S
79
89
98
107
110
700
600
600
500
500
56
62
68
75
82
6000
4800
160
80
60
145
150
160
175
185
512
480
436
400
372
5.00
4.60
4.08
3.80
3.44
.03
.03
.03
.05
.05
STA60K127S
STA60K135S
STA60K150S
STA60K167S
STA60K180S
127
135
150
167
180
400
400
300
300
260
91
100
110
120
130
40
16
8
8
8
195
210
230
250
270
348
316
272
256
228
3.08
2.80
2.40
2.20
2.00
.05
.05
.05
.06
.06
STA60K202S
STA60K226S
STA60K245S
STA60K279S
STA60K305S
202
226
245
279
305
260
200
200
200
160
150
160
180
200
220
8
8
8
8
8
300
335
360
400
435
208
188
172
156
140
1.76
1.56
1.44
1.24
1.12
.06
.06
.06
.06
.06
STA60K340S
STA60K360S
STA60K390S
STA60K450S
STA60K490S
340
360
390
450
490
160
120
120
120
100
240
270
300
330
360
8
8
8
8
8
470
520
550
600
650
128
120
108
100
92
1.04
0.96
0.84
0.72
0.70
.06
.06
.06
.07
.07
STA60K510S
STA60K560S
STA60K620S
STA60K680S
STA60K750S
510
560
620
680
750
100
80
80
80
80
390
430
470
510
560
8
8
8
8
8
700
780
870
930
1033
84
76
68
64
56
0.68
0.64
0.60
0.52
0.48
.07
.07
.08
.08
.08
STA60K820S
STA60K910S
STA60K1000S
820
910
1000
60
60
48
620
680
750
8
8
8
1135
1265
1385
52
48
44
0.44
0.40
0.36
.08
.08
.09
(% of 25°C Rated Power)
PEAK PULSE POWER
(kW)
PULSE WIDTH
Coefficient
STEADY STATE POWER DERATING
STEADY STATE
POWER
CURRENT PULSE WAVEFORM
% PEAK VALUE
PEAK PULSE POWER VS. PULSE WIDTH
Voltage
(Max)
@ Current
Tp=1ms
(note 3)
Maximum
Continuous
Current
Reverse
Leakage
Current
CASE TEMPERATURE (°C)
For optional high reliability screening or higher zener voltages, consult SSDI MARKETING Department.
Notes:
1. All voltages are measured with automated test set using 35 msec test time. Longer or shorter test times will have a corresponding effect on the measured value
due to heating effects.
2. Unless specified otherwise, ratings based on 25° C case temperature.
3. Pulse width (tp) is delined as the time from rated peak pulse current IPP to the point where peak pulse current decayed to 50% of rated IPP.
(10ms X 1000ms waveform as defined by R.E.A.)
DATA SHEET #: T00014C
4. Part Number- For 5% Voltage Tolerance, specify “B” in place of “A”