STA60K79S thru STA60K1000S Solid State Devices, Inc. 14701 Firestone Blvd * La Mirada, Ca 90638 Phone: (562) 404-4474 * Fax: (562) 404-1773 [email protected] * www.ssdi-power.com 60,000 WATTS PEAK PULSE POWER 79 – 1000 VOLTS HIGH VOLTAGE BIDIRECTIONAL TRANSIENT VOLTAGE SUPPRESSOR Designer’s Data Sheet • • • • • • FEATURES: 79-1000 Volt Bidirectional Smaller than 60KS200C Types Hermetically Sealed Meets all environmental requirements of MIL-PRF-19500 Custom Configurations Available TX and TXV Screening Available • • • APPLICATIONS: Protection of Voltage Sensitive Components Protection Against Power Interruption Lightning Protection Maximum Ratings (note 2) 56 - 750 Volts PD 400 Watts PPP 60,000 Watts Stand Off Voltage VRWM Steady State Power Dissipation Peak Pulse Power @ 1.0 msec Peak Pulse Power and Steady State Power Derating SEE GRAPH Peak Pulse Power and Pulse Width SEE GRAPH Operating and Storage Temperature -65°C to +175°C Note: SSDI Transient Suppressors offer standard Breakdown Voltage Tolerances of + 10% (A) and + 5% (B). For other Voltage and Voltage Tolerances, contact SSDI's Marketing Department PEAK PULSE POWER (% Rated 25°C Power) PEAK PULSE POWER VS. TEMPERATURE DERATING CURVE Package shown is standard configuration. SSDI can custom design your module with terminals that meet your unique design criteria. Additionally, SSDI can package these devices with an irregular footprint or offset mounting positions. This data sheet is meant to serve as an example of SSDI's Transient Protection Module Capabilities. For custom configurations, please contact SSDI's Marketing Department. AMBIENT TEMPERATURE (°C) NOTE: All specifications are subject to change without notification. SCD's for these devices should be reviewed by SSDI prior to release. DATA SHEET #: T00014D DOC Solid State Devices, Inc. STA60K79S thru STA60K1000S 14701 Firestone Blvd, La Mirada, Ca 90638 Phone: (562) 404-4474 Fax: (562) 404-1773 [email protected] www.ssdi-power.com ELECTRICAL CHARACTERISTICS (note 2) Break Down (note 1) Part Number (note 4) Max Reverse Stand Off Peak Pulse Clamping Voltage (Max) @ Current tp=1ms (note 3) Maximum Continuous Current Max Temperature Nominal Voltage Test Current Voltage Reverse Leakage Current VBR @ IBRT VRWM IR@VRWM VC IPP IRM TC Volts mA Volts µA Volts Amps Amps %/°C STA60K79S STA60K89S STA60K98S STA60K107S STA60K110S 79 89 98 107 110 700 600 600 500 500 56 62 68 75 82 6000 4800 160 80 60 145 150 160 175 185 512 480 436 400 372 5.00 4.60 4.08 3.80 3.44 .03 .03 .03 .05 .05 STA60K127S STA60K135S STA60K150S STA60K167S STA60K180S 127 135 150 167 180 400 400 300 300 260 91 100 110 120 130 40 16 8 8 8 195 210 230 250 270 348 316 272 256 228 3.08 2.80 2.40 2.20 2.00 .05 .05 .05 .06 .06 STA60K202S STA60K226S STA60K245S STA60K279S STA60K305S 202 226 245 279 305 260 200 200 200 160 150 160 180 200 220 8 8 8 8 8 300 335 360 400 435 208 188 172 156 140 1.76 1.56 1.44 1.24 1.12 .06 .06 .06 .06 .06 STA60K340S STA60K360S STA60K390S STA60K450S STA60K490S 340 360 390 450 490 160 120 120 120 100 240 270 300 330 360 8 8 8 8 8 470 520 550 600 650 128 120 108 100 92 1.04 0.96 0.84 0.72 0.70 .06 .06 .06 .07 .07 STA60K510S STA60K560S STA60K620S STA60K680S STA60K750S 510 560 620 680 750 100 80 80 80 80 390 430 470 510 560 8 8 8 8 8 700 780 870 930 1033 84 76 68 64 56 0.68 0.64 0.60 0.52 0.48 .07 .07 .08 .08 .08 STA60K820S STA60K910S STA60K1000S 820 910 1000 60 60 48 620 680 750 8 8 8 1135 1265 1385 52 48 44 0.44 0.40 0.36 .08 .08 .09 STEADY STATE POWER PEAK PULSE POWER (kW) STEADY STATE POWER DERATING (% of 25°C Rated Power) CURRENT PULSE WAVEFORM % PEAK VALUE PEAK PULSE POWER VS. PULSE WIDTH Coefficient PULSE WIDTH CASE TEMPERATURE (°C) For optional high reliability screening or higher zener voltages, consult SSDI MARKETING Department. Notes: 1. All voltages are measured with automated test set using 35 msec test time. Longer or shorter test times will have a corresponding effect on the measured value due to heating effects. 2. Unless specified otherwise, ratings based on 25° C case temperature. 3. Pulse width (tp) is defined as the time from rated peak pulse current IPP to the point where peak pulse current decayed to 50% of rated IPP. (10µs X 1000µs waveform as defined by R.E.A.) 4. Part Number- For 5% Voltage Tolerance, specify “B” in place of “A” NOTE: All specifications are subject to change without notification. SCD's for these devices should be reviewed by SSDI prior to release. DATA SHEET #: T00014D DOC