Embedded Power for Business-Critical Continuity Rev. 02.05.07 LPS25 Series 1 of 3 LPS25 Series RoHS 25 Watts Total Power: Input Voltage: # of Outputs: 25-40 Watts 85-264 VAC 120-300 VDC Single Electrical Specifications Special Features • • • • • • • • • • • • • Universal input 3" x 5" footprint Less than 1U high Remote sense Terminal block option (-T) Built-in EMI filter Low output ripple Adjustable output Overvoltage protection Overload protection 110 KHz switching frequency LPX40 enclosure kit available 2 year warranty Safety VDE 0805 EN60950 11774-3336-1241 (LC#84936) UL UL60950 E132002 CSA CSA 22.2-234 Level 3 LR53982C NEMKO EN 60950/EMKO-TUE P95100442 (74-sec) 203 CB Certificate and report 1577, 1578, 1579, 1580 CE Mark (LVD) Input Input range 85-264 VAC; 120-300 VDC Frequency 47-440 Hz Inrush current <15A peak @ 115VAC; <30A peak @ 230VAC, cold start @ 25°C Input current 1A max. (RMS) @ 115VAC Efficiency EMI filter 70% typical at full load FCC Class B conducted; CISPR 22 Class B conducted; EN55022 Class B conducted <0.5 mA @ 50/60 Hz, 264 VAC input Safety ground leakage current Output Maximum power 25 W for convection; 40W with 30CFM forced air Adjustment range -5, +10% minimum Hold-up time Overload protection 20 ms @ 25W load, 115VAC nominal line Short circuit protection on all outputs Case overload protected @ 110 -145% above peak rating Overvoltage protection 5V output; 5.7 to 6.7VDC. Other outputs 10% to 25% above nominal output Remote sense Compensates for 0.5 V lead drop minimum Will operate without remote sense connected Reverse connection protected Embedded Power for Business-Critical Continuity Rev. 02.05.07 LPS25 Series 2 of 3 Environmental Specifications Operating temperature: 0° to 50°C ambient. Derate each output 2.5% per degree from 50° to 70°C, -20°C start up. Storage temperature: Electromagnetic susceptibility: -40°C to +85°C Designed to meet IEC 801, -2, -3, -4, -5, -6, Level 3 Humidity: Operating; non-condensing 5% to 95% RH Three orthogonal axes, sweep at 1 oct/min, 5 min. dwell at four major resonances 0.75G peak 5Hz to 500Hz, operational >550,000 hours at full load and 25°C ambient conditions Vibration: MTBF demonstrated: Ordering Information Model Number Maximum Load Maximum Load Output Minimum with Convection with 30CFM Peak Load 1 Voltage Load Cooling Forced Air Regulation 2 LPS22(-T) 5V 0A 5A 8A 9A ±2% 50 mV LPS23(-T) 12V 0A 2.1A 3.3A 3.7A ±2% 120 mV LPS24(-T) 15V 0A 1.7A 2.7A 3A ±2% 150 mV LPS25(-T) 24V 0A 1.1A 1.8A 1.9A ±2% 240 mV Ripple P/P (PARD) 3 1. Peak current lasting <30 seconds with a maximum 10% duty cycle. 2. At 25°C including initial tolerance, line voltage, load currents and output voltages adjusted to factory settings. 3. Peak-to-peak with 20 MHz bandwidth and 10 μF in parallel with a 0.1 μF capacitor at rated line voltage and load ranges. 4. (-T) indicates Terminal Block option for input and output (instead of Molex type) Power Derating Curve 40W 30 CFM Forced Air Cooling 30W Output Power 25W (Watts) 20W 10W Natural Convection Cooling 20W 12.5W 0W 0°C 10°C 20°C 30°C 40°C 50°C 60°C 70°C TA – Ambient Temperature – °C Embedded Power for Business-Critical Continuity Astec Mechanical Drawing 0.22" (5.6) 4.55" (115.6) 5810 Van Allen Way Carlsbad, CA 92008 USA Telephone: +1 760 930 4600 Facsimile: +1 760 930 0698 5.00" (127) M1 GND SK201 3.00" (76.2) SK 1 1 M2 _+ 1 2 3 4 5 6 2.55" (64.8) 3 Rev. 02.05.07 LPS25 Series 3 of 3 N Remote Sense Connector Voltage Adj. Pot SK 2 Waterfront Business Park Merry Hill, Dudley West Midlands, DY5 1LX United Kingdom Telephone: +44 (0) 1384 842 211 Facsimile: +44 (0) 1384 843 355 13-15, Shing Wan Road Tai Wai, Shatin, N. T. Hong Kong Telephone: +852 2699 2868 Facsimile: +852 2699 1770 L 0.15" (4) DIA (4 places) For global contact, visit: www.astecpower.com [email protected] While every precaution has been taken to ensure accuracy and completeness in this literature, Emerson Network Power assumes no responsibility, and disclaims all liability for damages resulting from use of this information or for any errors or omissions. 1.14" (29) 0.197" (5) Pin Assignments Mating Connectors Connector LPS22 LPS23 LPS24 LPS25 SK1-1 SK1-3 Line Neutral Line Neutral Line Neutral Line Neutral SK2-1 SK2- 2 SK2- 3 +5 V +5 V +5 V +12 V +12 V +12 V +15V +15V +15V +24V +24V +24V SK2-4 Common Common Common Common SK2-5 SK2-6 SK201-1 SK201-2 Common Common +Sense -Sense Common Common +Sense -Sense Common Common +Sense -Sense Common Common +Sense -Sense AC Input: Molex 09-50-8031 (USA) Not required for (-T) option 09-91-0300 (UK) PINS: 08-52-0113 DC Outputs: Molex 09-50-8061 (USA) Not required for (-T) option 09-91-0600 (UK) PINS: 08-52-0113 Remote Molex 22-01-2025 PINS: 08-52-0123 Sense: Emerson Network Power. The global leader in enabling business-critical continuity. AC Power Connectivity Astec Connector Kit #70-841-006, includes all of the above DC Power 1. Specifications subject to change without notice. Embedded Power 2. 3. 6. All dimensions in inches (mm), tolerance is ±0.02" (±0.5mm) Mounting holes M1 and M2 should be grounded for EMI purposes. Mounting hole M1 is safety ground connection. Specifications are for convection rating at factory settings at 115 VAC input, 25°C unless otherwise stated. Warranty: 2 year 7. Weight: 0.5lbs/0.23kg 4. 5. Inbound Power Integrated Cabinet Solutions Outside Plant Precision Cooling Site Monitoring and Services EmersonNetworkPower. com Emerson Network Power and the Emerson Network Power logo are trademarks and service marks of Emerson Electric Co. ©2007 Emerson Electric Co.