Embedded Power for Business-Critical Continuity Rev. 06.15.09_101 LPS170 Series of 3 LPS170 Series 175 Watts Total Power: Input Voltage: # of Outputs: 100 - 175 Watts 85-264 VAC 120-300 VDC Single Electrical Specifications Special Features • • • • • • • • • • • • • • Active power factor correction IEC EN61000-3-2 compliance Wide Range Adjustable output Remote sense on main output Single wire current sharing Power fail and remote inhibit Built-in EMI filter Low output ripple Overvoltage protection Overload protection Thermal overload protection DC power good 5 V standby output 12 V Aux output Optional cover (-C suffix) Safety • VDE • UL • CB • CSA • CE • NEMKO 0805/EN60950 (IEC950) UL1950 Certificate and report CSA 22.2-234 Level 3 Mark (LVD) EN 60950/EMKO-TUE Input Input range: 85-264 VAC; 120-300 VDC Frequency: 47-63 Hz Inrush current: 38 A max, cold start @ 25°C Efficiency: EMI filter: 75% typical at full load FCC Class B conducted CISPR 22 Class B conducted EN55022 Class B conducted VDE 0878 PT3 Class B conducted Power Factor: 0.99 typical Safety ground leakage current: 1.0 mA @ 50/60 Hz, 264 VAC input Output Maximum power: 110 W convection (75 W with cover) 175 W with 30 CFM forced air (130 W with cover) Adjustment range: 2:1 wide ratio minimum Standby outputs: Hold-up time: 5 V @ 2 A regulated ±5% 20 ms @175 W load at nominal line Overload protection: Short circuit protection on all outputs. Case overload protected @ 110-145% above peak rating Overvoltage protection: 10% to 40% above nominal output Aux output: 12 V @ 1 A -5 %, +10% Embedded Power for Business-Critical Continuity Rev. 06.15.09_101 LPS170 Series of 3 Logic Control Power failure: TL logic signal goes high 100 - 500 msec after V1 output; It goes low at T least 4 msec before loss of regulation Remote inhibit: Requires contact closure to inhibit outputs Remote sense: ompensates for 0.5 V lead drop min. Will operate without remote C sense connected. Reverse connection protected. DC - OK: Pin Assignments Connector LPS17x SK1 PIN 1 +12 V PIN 2 5 V Standby Pin 3 Common Pin 4 V1 SWP PIN 5 Common PIN 6 +V1 sense PIN 7 Sense common PIN 8 Remote inhibit PIN 9 DC power good PIN 10 POK TB-1 COMMON TB-2 Main output PIN 1 GROUND PIN 2 LINE Pin 5 NEUTRAL TTL logic signal goes high after main output is in regulation. It goes low when there is a loss of regulation SK2 SK3 Environmental Specifications Operating temperature: Low temperature start: 0° to 50 °C ambient; derate each output at 2.5% per degree from 50° to 70 °C -20 °C Temperature coefficient: Storage temperature: Electromagnetic susceptibility: Humidity: ±0.4% per °C -40° to 85 °C Vibration: Three orthogonal axes, sweep at 1 oct/min, 5 min. dwell at four major resonances 0.75G peak 5Hz to 500Hz, operational >550,000 hours at full load and 25 °C ambient conditions MTBF demonstrated: Designed to meet IEC EN61000-4, -2, -3, -4, -5, -6, -8, -11 Level 3 Operating; non-condensing 5% to 95% Mating Connectors AC Input (SK3): Molex 09-50-8051 (USA) Molex 09-91-0500 (UK) PINS: 08-58-0111 DC Outputs (SK2): Molex 19141-0058 Control Signals (SK1): Molex 90142-0010 (USA) PINS: 90119-2110 or Amp: 87977-3 PINS: 87309-8 Emerson Network Power Connector Kit #70-841-016, includes all of the above 1. Specifications subject to change without notice. 2. All dimensions in inches (mm), tolerance is ±0.02” (±0.5mm) Ordering Information Model Number Output Voltage Minimum Load Maximum Load with Convection Cooling Maximum Load with 30CFM Peak Load 1 Regulation 2 Forced Air Ripple P/P (PARD)3 LPS172 5 V (2.5 - 6 V) 0A 22 A 35 A 38 A ±2% 50 mV LPS173 12 V (6 - 12 V) 0A 9.1 A 15 A 16.5 A ±2% 120 mV LPS174 15 V (12 - 24 V) 0A 7.3 A 12 A 13.2 A ±2% <1% LPS175 24 V (24 - 54 V) 0A 4.5 A 7.5 A 8.2 A ±2% <1% 1. Peak current lasting <30 seconds with a maximum 10% duty cycle. 2. At 25 °C including initial tolerance, line voltage, load currents and output voltages adjusted to factory settings. 3. Peak-to-peak with 20 MHz bandwidth and 10 µF in parallel with a 0.1 µF capacitor at rated line voltage and load ranges. 4. Remote inhibit resets OVP latch. Note: -C suffix added to the model number indicates cover option. 3. Mounting holes M1 and M2 should be grounded for EMI purposes. 4. Mounting hole M1 is safety ground connection. 5. Specifications are for convection rating at factory settings at 115 VAC input, 25 °C unless otherwise stated. 6. Warranty: 2 year 7. Weight: 0.5lbs/0.23kg Embedded Power for Business-Critical Continuity Mechanical Drawing 1 5 6 + Americas 5810 Van Allen Way Carlsbad, CA 92008 USA Telephone:+1 760 930 4600 Facsimile: +1 760 930 0698 - 10 SK1 Europe (UK) SK2 Waterfront Business Park Merry Hill, Dudley West Midlands, DY5 1LX United Kingdom Telephone:+44 (0) 1384 842 211 Facsimile: +44 (0) 1384 843 355 1.50 (38.1) Voltage Adj POT Rev. 06.15.09_101 LPS170 Series of 3 0.75 (19.0) 0.95 (24.0) 0.55 (14.0) Asia (HK) 6.61 (168.0) 7.4 (188.0) 14/F, Lu Plaza 2 Wing Yip Street Kwun Tong, Kowloon Hong Kong Telephone:+852 2176 3333 Facsimile: +852 2176 3888 8.5 (216.0) For global contact, visit: www.PowerConversion.com techsupport.embeddedpower @emerson.com 5 3 1 While every precaution has been taken to ensure accuracy and completeness in this literature, Emerson Network Power assumes no responsibility, and disclaims all liability for damages resulting from use of this information or for any errors or omissions. M3 #6-32 Emerson Network Power. The global leader in enabling business-critical continuity. SK3 0.88 (22.2) 1.07 (27.2) AC Power Connectivity DC Power 4.25 (108.0) 2.50 (63.5) 2.11 (53.5) Embedded Computing Embedded Power #6-32(8 PLACES) Monitoring Outside Plant M3(8 PLACES) Power Switching & Controls Precision Cooling Racks & Integrated Cabinets Services Surge Protection EmersonNetworkPower.com Emerson Network Power and the Emerson Network Power logo are trademarks and service marks of Emerson Electric Co. ©2009 Emerson Electric Co.