CYPRESS PALCE20V8L

fax id: 6010
1P AL CE 20 V8
PALCE20V8
Flash Erasable,
Reprogrammable CMOS PAL Device
Features
• QSOP package available
— 10, 15, and 25 ns com’l version
• Active pull-up on data input pins
• Low power version (20V8L)
— 55 mA max. commercial (15, 25 ns)
— 15, and 25 ns military/industrial versions
• High reliability
— Proven Flash technology
— 65 mA max. military/industrial
(15, 25 ns)
• Standard version has low power
— 90 mA max. commercial
(15, 25 ns)
— 100% programming and functional testing
Functional Description
The Cypress PALCE20V8 is a CMOS Flash Erasable second-generation programmable array logic device. It is implemented with the familiar sum-of-product (AND-OR) logic structure and the programmable macrocell.
— 115 mA max. commercial (10 ns)
— 130 mA max. military/industrial (15, 25 ns)
• CMOS Flash technology for electrical erasability and
reprogrammability
• User-programmable macrocell
— Output polarity control
The PALCE20V8 is executed in a 24-pin 300-mil molded DIP,
a 300-mil cerdip, a 28-lead square ceramic leadless chip carrier, a 28-lead square plastic leaded chip carrier, and a 24-lead
quarter size outline. The device provides up to 20 inputs and
8 outputs. The PALCE20V8 can be electrically erased and reprogrammed. The programmable macrocell enables the device to function as a superset to the familiar 24-pin PLDs such
as 20L8, 20R8, 20R6, 20R4.
— Individually selectable for registered or combinatorial operation
Logic Block Diagram (PDIP/CDIP/QSOP)
GND
I10
I9
I8
I7
I6
I5
I4
I3
I2
I1
CLK/I0
12
11
10
9
8
7
6
5
4
3
2
1
PROGRAMMABLE
AND ARRAY
(64 x 40)
MUX
8
8
8
8
Macrocell
Macrocell
Macrocell
Macrocell
8
Macrocell
8
8
Macrocell
Macrocell
8
Macrocell
MUX
13
OE/I11
14
15
16
17
18
19
20
21
22
23
24
I12
I/O0
I/O1
I/O2
I/O3
I/O4
I/O5
I/O6
I/O7
I13
VCC
20V8–1
PAL is a registered trademark of Advanced Micro Devices, Inc.
Cypress Semiconductor Corporation
•
3901 North First Street
•
San Jose
• CA 95134 •
408-943-2600
June 1994 – Revised March 26, 1997
PALCE20V8
Pin Configuration
PLCC/LCC
Top View
DIP/QSOP
Top View
CLK/I0
I1
I2
I3
I4
I5
I6
I7
I8
I9
I10
GND
1
2
3
4
5
6
7
8
9
10
11
12
24
23
22
21
20
19
18
17
16
15
14
13
VCC
I13
I/O7
I/O6
I/O5
I/O4
I/O3
I/O2
I/O1
4 3 2 1 2827 26
I3
I4
I5
NC
I6
I7
I8
I/O0
I12
OE/I11
20V8–2
5
6
7
8
9
10
11
121314 1516 1718
I/O6
I/O5
I/O4
NC
I/O3
I/O2
I/O1
25
24
23
22
21
20
19
20V8–3
Selection Guide
tPD ns
Generic Part Number
Com’l/Ind
tS ns
Mil
Com’l/Ind
tCO ns
Mil
Com’l/Ind
ICC mA
Mil
Com’l
Mil/Ind
PALCE20V8−5
5
3
4
115
PALCE20V8−7
7.5
7
5
115
PALCE20V8−10
10
10
10
10
7
10
115
130
PALCE20V8−15
15
15
12
12
10
12
90
130
PALCE20V8−25
25
25
15
20
12
20
90
130
PALCE20V8L−15
15
15
12
12
10
12
55
65
PALCE20V8L−25
25
25
15
20
12
20
55
65
Shaded area contains preliminary information.
Electronic Signature
Functional Description (continued)
An electronic signature word is provided in the PALCE20V8
that consists of 64 bits of programmable memory that can contain user-defined data.
The PALCE20V8 features 8 product terms per output and 40
input terms into the AND array. The first product term in a macrocell can be used either as an internal output enable control
or as a data product term.
Security Bit
There are a total of 18 architecture bits in the PALCE20V8
macrocell; two are global bits that apply to all macrocells and
16 that apply locally, two bits per macrocell. The architecture
bits determine whether the macrocell functions as a register or
combinatorial with inverting or noninverting output. The output
enable control can come from an external pin or internally from
a product term. The output can also be permanently enabled,
functioning as a dedicated output or permanently disabled,
functioning as a dedicated input. Feedback paths are selectable from either the input/output pin associated with the macrocell, the input/output pin associated with an adjacent pin, or
from the macrocell register itself.
A security bit is provided that defeats the readback of the internal programmed pattern when the bit is programmed.
Low Power
The Cypress PALCE20V8 provides low-power operation
through the use of CMOS technology, and increased testability
with Flash reprogrammability.
Product Term Disable
Product Term Disable (PTD) fuses are included for each product term. The PTD fuses allow each product term to be individually disabled.
Power-Up Reset
Input and I/O Pin Pull-Ups
All registers in the PALCE20V8 power-up to a logic LOW for
predictable system initialization. For each register, the associated output pin will be HIGH due to active-LOW outputs.
The PALCE20V8 input and I/O pins have built-in active
pull-ups that will float unused inputs and I/Os to an active
HIGH state (logical 1). All unused inputs and three-stated I/O
pins should be connected to another active input, VCC, or
Ground to improve noise immunity and reduce ICC.
2
PALCE20V8
Configuration Table
CG0
CG1
CL0x
Cell Configuration
Devices Emulated
0
1
0
Registered Output
Registered Med PALs
0
1
1
Combinatorial I/O
Registered Med PALs
1
0
0
Combinatorial Output
Small PALs
1
0
1
Input
Small PALs
1
1
1
Combinatorial I/O
20L8 only
Macrocell
OE
1 1
VCC
To
Adjacent
Macrocell
1 1
1 0
0 0
0 1
0 X
1 0
CG1
CL0x
1 1
0 X
D
Q
I/Ox
1 0
VCC
CLK
Q
1 0
1 1
0 X
CL1x
CG1 for pin 16 to 21 (DIP)
CG0 for pin 15 and 22 (DIP)
Maximum Ratings
CL0x
From
Adjacent
Pin
20V8–4
Output Current into Outputs (LOW)............................. 24 mA
DC Programming Voltage............................................. 12.5V
(Above which the useful life may be impaired. For user guidelines, not tested.)
Latch-Up Current ..................................................... >200 mA
Storage Temperature ..................................... −65°C to +150°C
Operating Range
Ambient Temperature with
Power Applied.................................................. −55°C to +125°C
Range
Supply Voltage to Ground Potential
(Pin 24 to Pin 12).................................................−0.5V to +7.0V
DC Input Voltage .................................................−0.5V to +7.0V
0°C to +75°C
5V ±5%
−40°C to +85°C
5V ±10%
Military[1]
−55°C to +125°C
5V ±10%
Note:
1. TA is the “instant on” case temperature.
3
VCC
Industrial
Commercial
DC Voltage Applied to Outputs
in High Z State .....................................................−0.5V to +7.0V
Ambient
Temperature
PALCE20V8
Electrical Characteristics Over the Operating Range[2]
Parameter
VOH
VOL
Description
Output HIGH Voltage
Output LOW Voltage
Test Conditions
Min.
VCC = Min.,
VIN = VIH or VIL
IOH = −3.2 mA
Com’l
IOH = −2 mA
Mil/Ind
VCC = Min.,
VIN = VIH or VIL
IOL = 24 mA
Com’l
IOL = 12 mA
Mil/Ind
Unit
2.4
V
0.5
VIH
Input HIGH Level
Guaranteed Input Logical HIGH Voltage for All Inputs[3]
2.0
VIL[4]
Input LOW Level
Guaranteed Input Logical LOW Voltage for All Inputs[3]
−0.5
IIH
Input or I/O HIGH Leakage
Current
3.5V < VIN < VCC
IIL[5]
Input or I/O LOW Leakage
Current
0V < VIN < VIN (Max.)
ISC
Output Short Circuit Current VCC = Max., VOUT = 0.5V[6,7]
ICC
Operating Power Supply
Current
VCC = Max.,
VIL = 0V, VIH = 3V,
Output Open,
f = 15 MHz
(counter)
Max.
V
V
0.8
V
10
µA
−100
µA
−150
mA
115
mA
15, 25 ns
90
mA
15L, 25L ns
55
mA
5, 7, 10 ns
−30
Com’l
10, 15, 25 ns
Mil/Ind
130
mA
15L, 25L ns
Mil/Ind
65
mA
Capacitance[7]
Parameter
Description
CIN
Input Capacitance
COUT
Output Capacitance
Test Conditions
Typ.
Unit
VIN = 2.0V @ f = 1 MHz
5
pF
VOUT = 2.0V @ f = 1 MHz
5
pF
Endurance Characteristics[7]
Parameter
N
Description
Minimum Reprogramming Cycles
Test Conditions
Min.
Normal Programming Conditions
100
Max.
Unit
Cycles
Notes:
2. See the last page of this specification for Group A subgroup testing information.
3. These are absolute values with respect to device ground. All overshoots due to system or tester noise are included.
4. VIL (Min.) is equal to −3.0V for pulse durations less than 20 ns.
5. The leakage current is due to the internal pull-up resistor on all pins.
6. Not more than one output should be tested at a time. Duration of the short circuit should not be more than one second. VOUT = 0.5V has been chosen to avoid test problems
caused by tester ground degradation.
7. Tested initially and after any design or process changes that may affect these parameters.
4
PALCE20V8
AC Test Loads and Waveforms
ALL INPUT PULSES
3.0V
90%
GND
90%
10%
10%
≤ 2 ns
≤ 2 ns
20V8–5
5V
S1
R1
OUTPUT
TEST POINT
R2
CL
20V8–6
Commercial
Specification
S1
tPD, tCO
Closed
tPZX, tEA
Z ➧ H: Open
Z ➧ L: Closed
tPXZ, tER
H ➧ Z: Open
L ➧ Z: Closed
Military
CL
R1
R2
R1
R2
Measured Output Value
50 pF
200Ω
390Ω
390Ω
750Ω
1.5V
1.5V
H ➧ Z: VOH − 0.5V
L ➧ Z: VOL + 0.5V
5 pF
5
PALCE20V8
Commercial and Industrial Switching Characteristics[2]
20V8−5
Parameter
Description
20V8−7
20V8−10
20V8−15
20V8−25
Min.
Max.
Min.
Max.
Min.
Max.
Min.
Max.
Min.
Max.
Unit
1
5
1
7.5
1
10
1
15
1
25
ns
15
20
ns
15
20
ns
10
15
25
ns
10
15
25
ns
12
ns
tPD
Input to Output
Propagation Delay[8]
tPZX
OE to Output Enable
5
6
10
tPXZ
OE to Output Disable
5
6
10
tEA
Input to Output
Enable Delay[7]
6
9
tER
Input to Output
Disable Delay[7,9]
6
9
tCO
Clock to Output Delay[8]
1
tS
Input or Feedback
Set-Up Time
3
tH
Input Hold Time
0
0
0
tP
External Clock Period
(tCO + tS)
7
12
17
tWH
Clock Width HIGH[7]
3
5
8
tWL
Clock Width LOW [7]
3
5
8
fMAX1
External Maximum
Frequency (1/(tCO + tS))[7,10]
143
83
fMAX2
Data Path Maximum
Frequency
(1/(tWH + tWL))[7, 11]
166.
6
fMAX3
Internal Feedback Maximum
Frequency (1/(tCF + tS))[7,12]
166.
6
tCF
Register Clock to
Feedback Input[7, 13]
tPR
Power-Up Reset Time[7]
4
1
1
7
10
1
10
ns
0
0
ns
22
27
ns
8
12
ns
8
12
ns
58
45.5
37
MHz
100
62.5
62.5
41.6
MHz
100
62.5
50
40
MHz
3
1
12
1
15
3
1
5
7
6
1
8
1
10
1
ns
µs
Shaded area contains preliminary information.
Notes:
8. Min. times are tested initially and after any design or process changes that may affect these parameters.
9. This parameter is measured as the time after OE pin or internal disable input disables or enables the output pin. This delay is measured to the point at which a previous
HIGH level has fallen to 0.5 volts below VOH min. or a previous LOW level has risen to 0.5 volts above VOL max.
10. This specification indicates the guaranteed maximum frequency at which a state machine configuration with external feedback can operate.
11. This specification indicates the guaranteed maximum frequency at which the device can operate in data path mode.
12. This specification indicates the guaranteed maximum frequency at which a state machine configuration with internal only feedback can operate.
13. This parameter is calculated from the clock period at fMAX internal (1/fMAX3) as measured (see Note 7 above) minus tS.
6
PALCE20V8
Military Switching Characteristics[2]
20V8−10
Parameter
Description
Max.
Min.
Max.
Min.
Max.
Unit
1
10
1
15
1
25
ns
15
20
ns
15
20
ns
10
15
25
ns
10
15
25
ns
20
ns
Input to Output
Propagation Delay[8]
tPZX
OE to Output Enable
10
tPXZ
OE to Output Disable
10
[7]
[7,9]
tER
Input to Output Enable Delay
Input to Output Disable Delay
[8]
20V8−25
Min.
tPD
tEA
20V8−15
tCO
Clock to Output Delay
1
tS
Input or Feedback Set-Up Time
10
10
12
1
12
20
1
ns
tH
Input Hold Time
0
0
0
ns
tP
External Clock Period (t CO + tS)
20
24
40
ns
tWH
Clock Width
HIGH[7]
8
10
15
ns
tWL
Clock Width LOW[7]
8
10
15
ns
fMAX1
External Maximum Frequency
(1/(tCO + tS)[7,10]
50
41.7
25
MHz
fMAX2
Data Path Maximum Frequency
(1/(tWH + tWL))[7, 11 ]
62.5
50
33.3
MHz
fMAX3
Internal Feedback Maximum
Frequency (1/(tCF + tS))[7,12]
62.5
50
33.3
MHz
tCF
Register Clock to
Feedback Input[7, 13]
tPR
Power-Up Reset Time[7]
6
1
Shaded area contains preliminary information.
7
8
1
10
1
ns
µs
PALCE20V8
Switching Waveform
INPUTS, I/O,
REGISTERED
FEEDBACK
tS
t WH
tH
t WL
CP
t CO
tP
tPXZ, tER[10]
tEA, tPZX[10]
[10]
tEA, tPZX[10]
REGISTERED
OUTPUTS
t PD
tPXZ, tER
COMBINATORIAL
OUTPUTS
20V8–7
Power-Up Reset Waveform
POWER
SUPPLY VOLTAGE
10%
VCC
90%
t PR
REGISTERED
ACTIVE LOW
OUTPUTS
tS
CLOCK
tPR MAX = 1 µs
8
t WL
20V8–8
PALCE20V8
Functional Logic Diagram for PALCE20V8
PIN NUMBERS DIP(PLCC) PACKAGE
PIN NUMBERS DIP(PLCC)PACKAGE
1 (2)
0
4
8
12
16
20
24
28
32
32
PTD
1
0
2 (3)
23 (27)
CG0
0
MC7
CL1=2560
CL0=2632
22 (26)
MC6
CL1=2561
CL0=2633
21 (25)
MC5
CL1=2562
CL0=2634
20 (24)
MC4
CL1=2563
CL0=2635
19 (23)
MC3
CL1=2564
CL0=2636
18 (21)
MC2
CL1=2565
CL0=2637
17 (20)
MC1
CL1=2566
CL0=2638
16 (19)
280
3 (4)
320
600
4 (5)
640
920
5 (6)
960
1240
6 (7)
1280
1560
7 (9)
1600
1880
8 (10)
1920
2200
9 (11)
2240
MC0
CL1=2567
CL0=2639
15 (18)
2520
10 (12)
11 (13)
0
1
14 (17)
CG0
13 (16)
ELECTRONIC SIGNATURE ROW
2568
2569 . . .
BYTE7
BYTE6 . . .
. . . 2630
. . . BYTE1
2631
BYTE0
CG0=2704
CG1=2705
20V8–9
MSB LSB
9
PALCE20V8
Ordering Information for PALCE20V8
ICC
(mA)
tPD
(ns)
tS
(ns)
tCO
(ns)
115
5
3
4
PALCE20V8−5JC
115
7.5
7
5
115
130
90
130
90
130
10
10
15
15
25
25
10
10
12
12
15
20
7
10
10
12
12
20
Ordering Code
Package
Name
Package Type
Operating
Range
J64
28-Lead Plastic Leaded Chip Carrier
Commercial
PALCE20V8−7JC
J64
28-Lead Plastic Leaded Chip Carrier
Commercial
PALCE20V8−7PC
P13
24-Lead (300-Mil) Molded DIP
PALCE20V8−10JC
J64
28-Lead Plastic Leaded Chip Carrier
PALCE20V8−10PC
P13
24-Lead (300-Mil) Molded DIP
PALCE20V8−10QC
Q13
24-Lead Quarter-Size Outline
PALCE20V8−10JI
J64
28-Lead Plastic Leaded Chip Carrier
PALCE20V8−10PI
P13
24-Lead (300-Mil) Molded DIP
PALCE20V8−10DMB
D14
24-Lead (300-Mil) CerDIP
PALCE20V8−10LMB
L64
28-Pin Square Leadless Chip Carrier
PALCE20V8−15JC
J64
28-Lead Plastic Leaded Chip Carrier
PALCE20V8−15PC
P13
24-Lead (300-Mil) Molded DIP
PALCE20V8−15QC
Q13
24-Lead Quarter-Size Outline
PALCE20V8−15JI
J64
28-Lead Plastic Leaded Chip Carrier
PALCE20V8−15PI
P13
24-Lead (300-Mil) Molded DIP
PALCE20V8−15QI
Q13
24-Lead Quarter-Size Outline
PALCE20V8−15DMB
D14
24-Lead (300-Mil) CerDIP
PALCE20V8−15LMB
L64
28-Pin Square Leadless Chip Carrier
PALCE20V8−25JC
J64
28-Lead Plastic Leaded Chip Carrier
PALCE20V8−25PC
P13
24-Lead (300-Mil) Molded DIP
PALCE20V8−25QC
Q13
24-Lead Quarter-Size Outline
PALCE20V8−25JI
J64
28-Lead Plastic Leaded Chip Carrier
PALCE20V8−25PI
P13
24-Lead (300-Mil) Molded DIP
PALCE20V8−25QI
Q13
24-Lead Quarter-Size Outline
PALCE20V8−25DMB
D14
24-Lead (300-Mil) CerDIP
PALCE20V8−25LMB
L64
28-Pin Square Leadless Chip Carrier
Shaded area contains preliminary information.
10
Industrial
Military
Commercial
Industrial
Military
Commercial
Industrial
Military
PALCE20V8
Ordering Information for PALCE20V8L
ICC
(mA)
tPD
(ns)
tS
(ns)
tCO
(ns)
55
15
12
10
65
55
65
15
25
25
12
15
20
12
12
20
Ordering Code
PALCE20V8L−15JC
Package
Name
Package Type
J64
28-Lead Plastic Leaded Chip Carrier
PALCE20V8L−15PC
P13
24-Lead (300-Mil) Molded DIP
PALCE20V8L−15QC
Q13
24-Lead Quarter-Size Outline
PALCE20V8L−15JI
J64
28-Lead Plastic Leaded Chip Carrier
PALCE20V8L−15PI
P13
24-Lead (300-Mil) Molded DIP
PALCE20V8L−15QI
Q13
24-Lead Quarter-Size Outline
PALCE20V8L−15DMB
D14
24-Lead (300-Mil) CerDIP
PALCE20V8L−15LMB
L64
28-Pin Square Leadless Chip Carrier
PALCE20V8L−25JC
J64
28-Lead Plastic Leaded Chip Carrier
PALCE20V8L−25PC
P13
24-Lead (300-Mil) Molded DIP
PALCE20V8L−25QC
Q13
24-Lead Quarter-Size Outline
PALCE20V8L−25JI
J64
28-Lead Plastic Leaded Chip Carrier
PALCE20V8L−25PI
P13
24-Lead (300-Mil) Molded DIP
PALCE20V8L−25QI
Q13
24-Lead Quarter-Size Outline
PALCE20V8L−25DMB
D14
24-Lead (300-Mil) CerDIP
PALCE20V8L−25LMB
L64
28-Pin Square Leadless Chip Carrier
MILITARY SPECIFICATIONS
Group A Subgroup Testing
Switching Characteristics
Parameter
DC Characteristics
Parameter
Subgroups
Subgroups
tPD
9, 10, 11
tCO
9, 10, 11
9, 10, 11
9, 10, 11
VOH
1, 2, 3
tS
VOL
1, 2, 3
tH
VIH
1, 2, 3
VIL
1, 2, 3
IIX
1, 2, 3
IOZ
1, 2, 3
ICC
1, 2, 3
Document #: 38−00367−D
11
Operating
Range
Commercial
Industrial
Military
Commercial
Industrial
Military
PALCE20V8
Package Diagrams
24-Lead (300-Mil) CerDIP D14
MIL −STD−1835 D− 9 Config.A
28-Lead Plastic Leaded Chip Carrier J64
28-Square Leadless Chip Carrier L64
MIL−STD −1835 C−4
12
PALCE20V8
Package Diagrams (continued)
24-Lead (300-Mil) Molded DIP P13/P13A
24-Lead Quarter Size Outline Q13
© Cypress Semiconductor Corporation, 1997. The information contained herein is subject to change without notice. Cypress Semiconductor Corporation assumes no responsibility for the use
of any circuitry other than circuitry embodied in a Cypress Semiconductor product. Nor does it convey or imply any license under patent or other rights. Cypress Semiconductor does not authorize
its products for use as critical components in life-support systems where a malfunction or failure may reasonably be expected to result in significant injury to the user. The inclusion of Cypress
Semiconductor products in life-support systems application implies that the manufacturer assumes all risk of such use and in doing so indemnifies Cypress Semiconductor against all charges.