AIMTEC AMEPR60

Series AMEPR60-AZ
up to 5A | AC-DC LED driver
FEATURES:
•
•
•
•
•
•
•
•
AC-DC Constant current LED Driver
Input range 90-305VAC/47-440Hz
High Efficiency up to 89%
Operating temperature -40 to 85°C
Over Temperature Protection
Waterproof Case rated IP68
Power Factor Correction
SCP, Over Current Protection
Models
Single output
Model
Max Output
Power (W) *
Output
Voltage
Range (V)
AMEPR60-50120AZ
AMEPR60-36170AZ
AMEPR60-24250AZ
AMEPR60-12500AZ
60
59.8
60
60
36-50
24-36
12-24
5-12
Output
Current (A)
Input Voltage
(VAC/Hz)
Input Voltage
(VDC)
Efficiency
(%)
90-305/47-440
90-305/47-440
90-305/47-440
90-305/47-440
120-430
120-430
120-430
120-430
89
88
87
85
1.2
1.66
2.5
5
*Exceeding the maximum output power will permanently damage the converter
NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at
rated output load unless otherwise specified.
Input Specifications
Parameters
Inrush current <2ms
Leakage current
AC current
Power Factor
External fuse
Start up time
Surge voltage
Conditions
Typical
115VAC
230VAC
115VAC
230VAC
115VAC
230VAC
115VAC
230VAC
30
50
0.5
0.7
0.73
0.33
Maximum
Units
A
mA
A
0.97
0.93
250V/1.5A
250
2sec
440
ms
V
Maximum
Units
Output Specifications
Parameters
Current accuracy
Line regulation
Load regulation
Ripple & Noise *
Hold-up time
Current adjustment range
Minimum Load Voltage
Conditions
Typical
±3
±1
±3
75
90
100-0
LL-HL
0-100% load
20MHz Bandwidth
%
%
%
mV p-p
ms
%
See the models table
* Tested with 0.1µF (M/C) or (C/C) and 10µF (E/C) parallel capacitors at the end.
Isolation Specifications
Parameters
Tested I/O voltage
Isolation Resistance
Isolation Capacitance
www.aimtec.com
F 052.1e R3.J
Conditions
Typical
3 sec/3.5mA
500VDC
>1000
1000
Tel: +1 514 620 2722
1 of 11
Rated
Units
3000
VAC
MΩ
pF
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AMEPR60-AZ
up to 5A | AC-DC LED driver
General Specifications
Parameters
Switching frequency
Over current protection
Over voltage protection
Short circuit protection
Short circuit restart
Over temperature protection
Operating temperature
Maximum case temperature
Storage temperature
Temperature coefficient
Cooling
Humidity
Case material
Potting
Wires
Weight
Dimensions (L X H X W)
MTBF
Conditions
Typical
With derating over 55°C
130
95-110% of Iout
110% of Vout
Continuous
Auto recovery
>105°C
-40 to +85
Maximum
Units
KHz
o
100
-40 to +95
±0.02
Free air convection
95
C
C
o
C
% / oC
o
% RH
Plastic
Epoxy (IP67 rated)
UL1015 18AWG *20CM
350
5.30 x 2.27 x 1.59 inches
134.80 x 57.68 x 40.50 mm
>400,000 hrs (MIL-HDBK-217F at +25°C)
g
Safety Specifications
Parameters
Agency approvals
Standards
cULus CE
UL8750, UL60950-1, EN55022, class B, EN60529(IP68), EN61347-1, EN61347-2-13
Dimensions
End View
40.50
(1.59)
Top View
134.80
(5.30)
16.75
(0.66)
57.68
(2.27)
32.00 60.00
(1.26) (2.36)
Side View
40.50
(1.59)
200.00
(8.00)
Input/Output Wires are 18 AWG 20cm
www.aimtec.com
F 052.1e R3.J
200.00
(8.00)
2.30
(0.09)
161.30
(6.35)
Tel: +1 514 620 2722
2 of 11
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AMEPR60-AZ
up to 5A | AC-DC LED driver
Application Circuit
Model Number
Maximum Pot
Value (kΩ)
AMEPR60-50120AZ
AMEPR60-36170AZ
AMEPR60-24250AZ
AMEPR60-12500AZ
26.00
16.95
26.10
34.10
Temperature graph
Free Air Convection
55 º C
100
80
Safe Operating Area
60
40
20
0
-40
-20
0
20
40
60
80
85
100
Ambient Temperature º C
www.aimtec.com
F 052.1e R3.J
Tel: +1 514 620 2722
3 of 11
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AMEPR60-AZ
up to 5A | AC-DC LED driver
Efficiency Vs. Input Voltage & Output Current (Constant current load)
AMEPR60-50120AZ
AMEPR60-36170AZ
www.aimtec.com
F 052.1e R3.J
Tel: +1 514 620 2722
4 of 11
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AMEPR60-AZ
up to 5A | AC-DC LED driver
Efficiency Vs. Input Voltage & Output Current (Constant current load)
Continued
AMEPR60-24250AZ
AMEPR60-12500AZ
www.aimtec.com
F 052.1e R3.J
Tel: +1 514 620 2722
5 of 11
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AMEPR60-AZ
up to 5A | AC-DC LED driver
PFC Value vs. Output Load Current (constant current mode)
AMEPR60-50120AZ
AMEPR60-36170AZ
www.aimtec.com
F 052.1e R3.J
Tel: +1 514 620 2722
6 of 11
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AMEPR60-AZ
up to 5A | AC-DC LED driver
PFC Value vs. Output Load Current (constant current mode)
Continued
AMEPR60-24250AZ
AMEPR60-12500AZ
www.aimtec.com
F 052.1e R3.J
Tel: +1 514 620 2722
7 of 11
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AMEPR60-AZ
up to 5A | AC-DC LED driver
Constant Current vs. Constant Voltage Mode
AMEPR60-50120AZ
AMEPR60-36170AZ
www.aimtec.com
F 052.1e R3.J
Tel: +1 514 620 2722
8 of 11
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AMEPR60-AZ
up to 5A | AC-DC LED driver
Constant Current vs. Constant Voltage Mode
Continued
AMEPR60-24250AZ
AMEPR60-12500AZ
www.aimtec.com
F 052.1e R3.J
Tel: +1 514 620 2722
9 of 11
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AMEPR60-AZ
up to 5A | AC-DC LED driver
Dimming Control (Output Current vs. Radj)
AMEPR60-50120AZ
AMEPR60-36170AZ
www.aimtec.com
F 052.1e R3.J
Tel: +1 514 620 2722
10 of 11
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AMEPR60-AZ
up to 5A | AC-DC LED driver
Constant Current vs. Constant Voltage Mode
Continued
AMEPR60-24250AZ
AMEPR60-12500AZ
NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled
by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based on the
date manufactured. 3. Mechanical drawings and specifications are for reference only. 4. All specifications are measured at an ambient temperature of 25°C, humidity<75%,
nominal input voltage and at rated output load unless otherwise specified. 5. Aimtec may not have conducted destructive testing or chemical analysis on all internal components
and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for release. 6. This
product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications which necessitate
specific safety and regulatory standards other the ones listed in this datasheet. 7. Warranty is in accordance with Aimtec’s standard Terms of Sale available at www.aimtec.com.
www.aimtec.com
F 052.1e R3.J
Tel: +1 514 620 2722
11 of 11
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only