Series AMEPR60-AZ up to 5A | AC-DC LED driver FEATURES: • • • • • • • • AC-DC Constant current LED Driver Input range 90-305VAC/47-440Hz High Efficiency up to 89% Operating temperature -40 to 85°C Over Temperature Protection Waterproof Case rated IP68 Power Factor Correction SCP, Over Current Protection Models Single output Model Max Output Power (W) * Output Voltage Range (V) AMEPR60-50120AZ AMEPR60-36170AZ AMEPR60-24250AZ AMEPR60-12500AZ 60 59.8 60 60 36-50 24-36 12-24 5-12 Output Current (A) Input Voltage (VAC/Hz) Input Voltage (VDC) Efficiency (%) 90-305/47-440 90-305/47-440 90-305/47-440 90-305/47-440 120-430 120-430 120-430 120-430 89 88 87 85 1.2 1.66 2.5 5 *Exceeding the maximum output power will permanently damage the converter NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at rated output load unless otherwise specified. Input Specifications Parameters Inrush current <2ms Leakage current AC current Power Factor External fuse Start up time Surge voltage Conditions Typical 115VAC 230VAC 115VAC 230VAC 115VAC 230VAC 115VAC 230VAC 30 50 0.5 0.7 0.73 0.33 Maximum Units A mA A 0.97 0.93 250V/1.5A 250 2sec 440 ms V Maximum Units Output Specifications Parameters Current accuracy Line regulation Load regulation Ripple & Noise * Hold-up time Current adjustment range Minimum Load Voltage Conditions Typical ±3 ±1 ±3 75 90 100-0 LL-HL 0-100% load 20MHz Bandwidth % % % mV p-p ms % See the models table * Tested with 0.1µF (M/C) or (C/C) and 10µF (E/C) parallel capacitors at the end. Isolation Specifications Parameters Tested I/O voltage Isolation Resistance Isolation Capacitance www.aimtec.com F 052.1e R3.J Conditions Typical 3 sec/3.5mA 500VDC >1000 1000 Tel: +1 514 620 2722 1 of 11 Rated Units 3000 VAC MΩ pF Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AMEPR60-AZ up to 5A | AC-DC LED driver General Specifications Parameters Switching frequency Over current protection Over voltage protection Short circuit protection Short circuit restart Over temperature protection Operating temperature Maximum case temperature Storage temperature Temperature coefficient Cooling Humidity Case material Potting Wires Weight Dimensions (L X H X W) MTBF Conditions Typical With derating over 55°C 130 95-110% of Iout 110% of Vout Continuous Auto recovery >105°C -40 to +85 Maximum Units KHz o 100 -40 to +95 ±0.02 Free air convection 95 C C o C % / oC o % RH Plastic Epoxy (IP67 rated) UL1015 18AWG *20CM 350 5.30 x 2.27 x 1.59 inches 134.80 x 57.68 x 40.50 mm >400,000 hrs (MIL-HDBK-217F at +25°C) g Safety Specifications Parameters Agency approvals Standards cULus CE UL8750, UL60950-1, EN55022, class B, EN60529(IP68), EN61347-1, EN61347-2-13 Dimensions End View 40.50 (1.59) Top View 134.80 (5.30) 16.75 (0.66) 57.68 (2.27) 32.00 60.00 (1.26) (2.36) Side View 40.50 (1.59) 200.00 (8.00) Input/Output Wires are 18 AWG 20cm www.aimtec.com F 052.1e R3.J 200.00 (8.00) 2.30 (0.09) 161.30 (6.35) Tel: +1 514 620 2722 2 of 11 Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AMEPR60-AZ up to 5A | AC-DC LED driver Application Circuit Model Number Maximum Pot Value (kΩ) AMEPR60-50120AZ AMEPR60-36170AZ AMEPR60-24250AZ AMEPR60-12500AZ 26.00 16.95 26.10 34.10 Temperature graph Free Air Convection 55 º C 100 80 Safe Operating Area 60 40 20 0 -40 -20 0 20 40 60 80 85 100 Ambient Temperature º C www.aimtec.com F 052.1e R3.J Tel: +1 514 620 2722 3 of 11 Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AMEPR60-AZ up to 5A | AC-DC LED driver Efficiency Vs. Input Voltage & Output Current (Constant current load) AMEPR60-50120AZ AMEPR60-36170AZ www.aimtec.com F 052.1e R3.J Tel: +1 514 620 2722 4 of 11 Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AMEPR60-AZ up to 5A | AC-DC LED driver Efficiency Vs. Input Voltage & Output Current (Constant current load) Continued AMEPR60-24250AZ AMEPR60-12500AZ www.aimtec.com F 052.1e R3.J Tel: +1 514 620 2722 5 of 11 Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AMEPR60-AZ up to 5A | AC-DC LED driver PFC Value vs. Output Load Current (constant current mode) AMEPR60-50120AZ AMEPR60-36170AZ www.aimtec.com F 052.1e R3.J Tel: +1 514 620 2722 6 of 11 Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AMEPR60-AZ up to 5A | AC-DC LED driver PFC Value vs. Output Load Current (constant current mode) Continued AMEPR60-24250AZ AMEPR60-12500AZ www.aimtec.com F 052.1e R3.J Tel: +1 514 620 2722 7 of 11 Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AMEPR60-AZ up to 5A | AC-DC LED driver Constant Current vs. Constant Voltage Mode AMEPR60-50120AZ AMEPR60-36170AZ www.aimtec.com F 052.1e R3.J Tel: +1 514 620 2722 8 of 11 Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AMEPR60-AZ up to 5A | AC-DC LED driver Constant Current vs. Constant Voltage Mode Continued AMEPR60-24250AZ AMEPR60-12500AZ www.aimtec.com F 052.1e R3.J Tel: +1 514 620 2722 9 of 11 Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AMEPR60-AZ up to 5A | AC-DC LED driver Dimming Control (Output Current vs. Radj) AMEPR60-50120AZ AMEPR60-36170AZ www.aimtec.com F 052.1e R3.J Tel: +1 514 620 2722 10 of 11 Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AMEPR60-AZ up to 5A | AC-DC LED driver Constant Current vs. Constant Voltage Mode Continued AMEPR60-24250AZ AMEPR60-12500AZ NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based on the date manufactured. 3. Mechanical drawings and specifications are for reference only. 4. All specifications are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at rated output load unless otherwise specified. 5. Aimtec may not have conducted destructive testing or chemical analysis on all internal components and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for release. 6. This product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications which necessitate specific safety and regulatory standards other the ones listed in this datasheet. 7. Warranty is in accordance with Aimtec’s standard Terms of Sale available at www.aimtec.com. www.aimtec.com F 052.1e R3.J Tel: +1 514 620 2722 11 of 11 Toll free: + 1 888 9 AIMTEC (924 6832) North America only