Series AMEOS40-MAZ 40 Watt | AC-DC / DC-DC Converter FEATURES: • • • • Models Single output Model AMEOS40-3.3SMAZ AMEOS40-5SMAZ AMEOS40-12SMAZ AMEOS40-15SMAZ AMEOS40-24SMAZ Models Dual output Model AMEOS40-5DMAZ AMEOS40-12DMAZ AMEOS40-15DMAZ AMEOS40-24DMAZ 4000VAC I/O isolation Operating temperature: -40°C to +85°C Over load, Over voltage, Short circuit protection Universal Input: 90-260VAC, 47-440Hz, or 120-370VDC • • • • Energy star compliant RoHS compliant Low ripple and noise CE, cULus, CB approvals CB Input Voltage (VAC/Hz) Input Voltage (VDC) Output Voltage (V) Output Current max (A) Efficiency (%) Input Voltage (VAC/Hz) Input Voltage (VDC) Output Voltage (V) Output Current max(A) Efficiency (%) 90-264/47-440 90-264/47-440 90-264/47-440 90-264/47-440 90-264/47-440 120-370 120-370 120-370 120-370 120-370 90-264/47-440 90-264/47-440 90-264/47-440 90-264/47-440 120-370 120-370 120-370 120-370 3.3 5 12 15 24 ±5 ±12 ±15 ±24 8 8 3.33 2.66 1.66 ±4 ±1.66 ±1.33 ±0.835 78 82 84 83 82 80 85 82 77 NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at rated output load unless otherwise specified. Input Specifications Parameters Conditions Current Inrush current <2ms Leakage current External fuse Input dissipation Start-up time Output Specifications Parameters Voltage accuracy Line regulation Load regulation Cross regulation Maximum Capacitive load Transient response deviation Ripple & Noise* Hold-up time (min) Minimum Load Current Typical 115 VAC 230 VAC 115 VAC 230 VAC Recommended slow blow type No load; 115VAC No load; 264VAC 3.15 <0.5 <0.8 117 Conditions Typical (LL-HL) 0-100% load single 0-100% load dual 25% load - 1st out, 100% load – 2nd out Depending of the model 25% load Step 20MHz bandwidth 115VAC *Ripple & Noise measured with 0.1μF M/C and 1μF E/C www.aimtec.com F 052e R7.H Tel: +1 514 620 2722 1 of 5 ±2 ±0.5 ±1 ±2 ±5 470-23 000 ±2 50 29 0 Maximum 1000 530 25 50 150 Units mA A µA A W ms Maximum Units % % % % µF % of Vout mV p-p ms % of Max Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AMEOS40-MAZ 40 Watt | AC-DC / DC-DC Converter Isolation Specifications Parameters Conditions Tested I/O voltage Isolation Resistance General Specifications Parameters Switching frequency Over current protection Over voltage protection Short circuit protection Short Circuit restart Operating temperature Maximum case temperature Storage temperature Temperature coefficient Cooling Humidity Weight Dimensions (L X H X W) MTBF Shock Vibration >1000 Conditions Parameters Wave form Acceleration amplitude Bump duration Converter operation Number of bumps Test mode Displacement Acceleration Converter operation Units 4000 VAC MΩ Maximum 47 110 Zener diode clamp Hiccup mode, indefinite Auto recovery -40 - +85 With derating above 55ºC Non condensing Rated Typical Auto recovery Environment Approval Test Typical 3 sec 140 110 Units KHz % % o C C o C % / oC o 100 -40 to +95 0.02 Free air convection 145 4.92 x 2.32 x 1.02 inches 125 x 59 x 26mm, > 800 000 hrs (MIL-HDBK -217F, t=+25oC) 95 % RH g Conditions Half sine wave 5gn 30 ms Before and after test, body mounted (on chassis) 18 (3 in each direction for every axis) Sweep sine, 10-100Hz, speed 0.05Hz/s 1 mm 3g, 3 loops 30min one cycle, 3h total, every axis tested Before and after test, body mounted (on chassis) Safety Specifications Parameters Agency approvals Standards www.aimtec.com F 052e R7.H cULus, CE, CB Scheme Medical Electrical Equipment Information technology Equipment EMI - Conducted and radiated emission Harmonic Current Emissions Voltage fluctuations and flicker Electrostatic Discharge Immunity RF, Electromagnetic Field Immunity Electrical Fast Transient/Burst Immunity Surge Immunity RF, Conducted Disturbance Immunity Power frequency Magnetic Field Immunity Voltage dips, Short Interruptions Immunity IEC\EN\UL 60601-1, CSA-C22.2 No. 601.1-M90 EN 60950-1:2006+A11:2009 EN55011, class B IEC/EN 61000-3-2, (EN60555-2) IEC/EN 61000-3-3, (EN60555-3) IEC 61000-4-2 IEC 61000-4-3 IEC 61000-4-4 IEC 61000-4-5 IEC 61000-4-6 IEC 61000-4-8 IEC 61000-4-11 Tel: +1 514 620 2722 2 of 5 Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AMEOS40-MAZ 40 Watt | AC-DC / DC-DC Converter Pin Out Specifications Pin 1 2 3 4 5 6 Single AC Input (L) AC Input (N) +V Output -V Output N.C. N.C. Dual N.C.= Not Connected Dimensions AC Input (L) AC Input (N) +V Output Common Common -V Output 59.00 (2.32) 59.00 (2.32) 52.00 (2.05) 1 2 3.50 (0.14) 118.00 (4.65) 125.00 (4.90) AC Input Screw Terminals 3.50 (0.14) Bottom View DC Output Screw Terminals 3 4 5 6 Top View 5.00 (0.20) 25.00 (0.98) Side View www.aimtec.com F 052e R7.H Tel: +1 514 620 2722 3 of 5 Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AMEOS40-MAZ 40 Watt | AC-DC / DC-DC Converter Derating Free Air Convection 55º C Output Power (%) 100 80 Safe Operating Area 60 40 20 0 - 40 - 20 0 20 40 60 80 85 100 Ambient Temperature º C NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based on the date manufactured. 3. Mechanical drawings and specifications are for reference only. 4. All specifications are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at rated output load unless otherwise specified. 5. Aimtec may not have conducted destructive testing or chemical analysis on all internal components and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for release. 6. This www.aimtec.com F 052e R7.H Tel: +1 514 620 2722 4 of 5 Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AMEOS40-MAZ 40 Watt | AC-DC / DC-DC Converter product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications which necessitate specific safety and regulatory standards other the ones listed in this datasheet. 7. Warranty is in accordance with Aimtec’s standard Terms of Sale available at www.aimtec.com. www.aimtec.com F 052e R7.H Tel: +1 514 620 2722 5 of 5 Toll free: + 1 888 9 AIMTEC (924 6832) North America only