Series AME15-MAZ 15 Watt | AC-DC / DC-DC Converter FEATURES: • • • • 4000VAC I/O Isolation Operating temperature: -40 to +80°C Over load, Over Voltage, Short Circuit Protection Universal input: 90-264VAC, 47-440Hz • • • • RoHS compliant Soft start Energy Star compliant CE, cULus, CB approvals CB Models Single output Model Input Voltage (VAC/Hz) Input voltage (VDC) 90-264/47-440 90-264/47-440 90-264/47-440 90-264/47-440 90-264/47-440 120-370 120-370 120-370 120-370 120-370 AME15-3.3SMAZ AME15-5SMAZ AME15-12SMAZ AME15-15SMAZ AME15-24SMAZ Output Voltage (V) Output Current max (A) 3.3 5 12 15 24 3 3 1.25 1 0.63 Maximum capacitive Load (µF) Efficiency (%) 4700 2200 1000 680 470 74 78 81 81 83 Models Dual output Model Input Voltage (VAC/Hz) Input voltage (VDC) Output Voltage (V) AME15-5DMAZ AME15-12DMAZ AME15-15DMAZ 90-264/47-440 90-264/47-440 90-264/47-440 120-370 120-370 120-370 ±5 ±12 ±15 Input Specifications Parameters Leakage current External Fuse (recommend) Input Dissipation Under Voltage Protection Output Specifications Parameters Parameters www.aimtec.com F 052e R8.I 2 <0.5 88 Conditions Typical ±2 ±0.5 ±0.5 ±5 200 ±2 100 20 LL-HL 0-100% 25% load - 1st out, 100% load – 2nd out 25% load step 20MHz bandwidth *Ripple & Noise measured with 1μF M/C and 47μF E/C Tested I/O voltage Isolation resistance Typical 115 VAC 230 VAC 115 VAC 230 VAC 115 VAC 264 VAC slow blow type No Load Inrush current <2ms (Cold Start) Isolation Specifications ±1.5 ±0.63 ±0.5 Conditions Current Voltage accuracy Line regulation Load regulation (single) Cross regulation (dual) Transient Recovery Time Transient Response Deviation Ripple & Noise* Hold-up time Output Current Maximum Capacitive Load (µF) max (A) min Conditions Typical 3sec >1000 Tel: +1 514 620 2722 1 of 4 ±1000 ±470 ±330 Efficiency (%) 78 80 81 Maximum Units Maximum Units 350 180 10 20 0.1 0.2 Rated 4000 mA mA A A mA mA A W VAC % % % % µs % of Vout mVp-p ms Units VAC MΩ Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AME15-MAZ 15 Watt | AC-DC / DC-DC Converter General Specifications Parameters Switching frequency Start up time Over load protection Over voltage protection Short Circuit protection Short Circuit restart Operating temperature Storage temperature Max Case temperature Temperature coefficient Cooling Humidity Weight Dimensions (L x W x H) MTBF Case material Conditions Typical 132 900 >131 Zener diode clamp Continous Auto recovery -40 to +80 -40 to +100 Auto recovery, hiccup mode With derating over 55 oC ±0.02 Free air convection Maximum Units KHz mS % o C C o C % / oC o 100 95 100 2.56 x 1.83 x 0.79 inches 65.0 x 46. 5 x 20.1 mm , ±0.5mm > 400 000hrs (MIL-HDBK -217F, t=+25oC) Plastic resin + Fiberglass (flammability to UL 94V-0) % RH g NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at rated output load unless otherwise specified. Environment Approval Parameters Shock Vibrations Conditions Wave form: Half sine wave Acceleration amplitude: 5gn Bump duration: 30 ms Number of bumps: 18 (3 in each direction for every axis) Converter operation before and after test, body mounted (on chassis) Test mode: Sweep sine 10-100Hz, speed 0.05Hz/s Displacement: 1mm Acceleration: 3g 3 loops 30min one cycle, 3h total, every axis tested Converter operation before and after test, body mounted (on chassis) Safety & EMC Specifications Parameters Agency approvals Standards www.aimtec.com F 052e R8.I cULus, CE, CB Medical Electrical Equipment Information technology Equipment EMI - Conducted and radiated emission Harmonic Current Emissions Voltage fluctuations and flicker Electrostatic Discharge Immunity RF, Electromagnetic Field Immunity Electrical Fast Transient/Burst Immunity Surge Immunity RF, Conducted Disturbance Immunity Power frequency Magnetic Field Immunity Voltage dips, Short Interruptions Immunity Tel: +1 514 620 2722 2 of 4 IEC\EN\UL 60601-1, CSA-C22.2 No. 601.1-M90 EN 60950-1:2006+A11:2009 EN55011, class B IEC/EN 61000-3-2, (EN60555-2) IEC/EN 61000-3-3, (EN60555-3) IEC 61000-4-2 IEC 61000-4-3 IEC 61000-4-4 IEC 61000-4-5 IEC 61000-4-6 IEC 61000-4-8 IEC 61000-4-11 Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AME15-MAZ 15 Watt | AC-DC / DC-DC Converter Pin Out Specifications Pin Single 1 2 3 4 5 6 No pin AC Input (N) AC Input (L) -V Output No pin +V Output Dual No pin AC Input (N) AC Input (L) -V Output Common +V Output Dimensions (Top View) 2.56 (65.00) 0.23 (5.75) 2.13 (54.00) 1 0.69 (17.50) 1.83 (46.50) TOP VIEW 2 5 0.69 (17.50) 6 3 0.23 (5.75) 4 0.18 (4.50) 1 0.52 (13.24) TOP VIEW 0.39 (10.00) 2 0.39 (10.00) 4 5 6 0.52 (13.24) 3 0.26 (6.50) DIV: 0.4 (11.6) 6 Ø- 0.047 (Ø 1.2) Dimensions: inch (mm) Case Tolerance:± 0.1 (2.54) Pin Pitch Tolerance: ± 0.012 (0.30) 0.79 (20.10) Ø 0.04 (1.00) 0.2 (5.08) (Min) www.aimtec.com F 052e R8.I Tel: +1 514 620 2722 3 of 4 Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AME15-MAZ 15 Watt | AC-DC / DC-DC Converter Derating Free Air Convection 55 º C 100 80 Safe Operating Area 60 40 20 0 -40 -20 0 20 40 60 85 80 100 Ambient Temperature º C NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based on the date manufactured. 3. Mechanical drawings and specifications are for reference only. 4. All specifications are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at rated output load unless otherwise specified. 5. Aimtec may not have conducted destructive testing or chemical analysis on all internal components and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for release. 6. This product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications which necessitate specific safety and regulatory standards other the ones listed in this datasheet. 7. Warranty is in accordance with Aimtec’s standard Terms of Sale available at www.aimtec.com. www.aimtec.com F 052e R8.I Tel: +1 514 620 2722 4 of 4 Toll free: + 1 888 9 AIMTEC (924 6832) North America only