MA-COM 5EFM1S

CORCOM Product Guide
Power Entry Module with Optional RFI Power Line Filters for General and
Medical Applications
M Series
XM/ZM
UL Recognized
CSA Certified
VDE Approved
VM
M Series
The M series power entry modules offer the most choices
of power entry components and filtering options to fit a
specific need. The fully configured M series expands the
options of a manufacturer whose products are marketed
worldwide. One component, fully assembled and tested,
provides the capability of interfacing a multi-voltage power
supply to any common voltage or fusing scheme in the
world, without modification.
•The IEC connector provides an internationally accepted
power entry termination, which can be used with a variety
of line cords.
•The selectable fuseholder allows use of single or dual
European fuses, or a single North American fuse.
•The optional DPST on/off switch breaks both sides of the
line and is labeled with the international I/O markings.
FM Models – General purpose RFI filter designed for susceptibility applications, effectively providing RFI control of
line-to-ground noise. The design is compact and meets
the very low leakage current requirements of VDE portable
equipment as well as (120 Volt) UL544 non-patient medical
equipment.
XM Models – High performance RFI filter designed to bring
most digital equipment (including switching power
supplies) into compliance with FCC Part 15J, Class B
conducted emissions limits.
ZM Models – Premium RFI filter designed to bring most
digital equipment (including switching power supplies) into
compliance with EN55022, Level B (as well as FCC Part
15J, Class B) conducted emissions limits.
Fuse Installation Instructions
•The optional voltage selector provides a convenient
means to change transformer primary connection,
and it is available in both 2-voltage and 4-voltage
configurations.
•The series is available with four filter circuits to meet a
variety of applications, and convenient connections are
provided on unfiltered models to allow wiring of a
separate RFI filter.
The M series is a family of components offering greater
flexibility and cost-effectiveness in the selection of primary
power components. Wiring to the modules is accomplished via .110” terminals for labor savings and
convenience.
Four filter circuits provide a choice of attenuation tailored to
specific categories of susceptibility and emissions needs.
HM Models – This medical filter provides susceptibility
protection without the leakage current associated with
line-to-ground capacitors. Designed to allow equipment
to meet UL544 for patient care and non-patient care
equipment, the HM filter has a maximum leakage current
of 2 µA at 120 VAC 60 Hz. See Appendix C for more
information on medical applications and UL standards.
1.
2.
3.
4.
5.
6.
7.
Remove power cord.
Pry door open at socket.
Lift and swing door into socket.
Lift fuse holder out of housing.
Install one (1) AG fuse or two (2) metric fuses*.
Replace fuse holder into housing.
Swing and snap door back in place.
*Install fuses on one side only, do not install both AG and metric fuses at the
same time.
124
Catalog 1654001
Revised 05-07
Dimensions are in inches and
millimeters unless otherwise
specified. Values in italics
are metric equivalents.
Dimensions are shown for
reference purposes only.
Specifications subject
to change.
USA Cust. Svc.: 1-800-468-2023
CORCOM Prods: 1-847-680-7400
Germany:
49-89-6089-0
www.corcom.com
www.tycoelectronics.com
CORCOM Product Guide
Power Entry Module with Optional RFI Power Line Filters for General and
Medical Applications (Continued)
M Series
Removing the Fuse Holder
Fuse Options
European Fusing Arrangement**
1. Insert a pocket screwdriver at point “X” as shown.
"X"
A
Power Entry Modules
A
Section A-A
North American Fusing Arrangement**
Gently lift UP until the entire door lifts up approximately
1/4" (minimum).
Lift Up
2. Once lifted, the door will pivot on it’s hinges and
expose the fuse holder.
**Install fuses on one side only. Do Not install both AG and Metric fuses at
the same time.
Voltage Selection
To change selected voltage: open cover, using small
blade screwdriver or similar tool; set aside cover/fuse
block assembly; pull voltage selector card straight out of
housing, using indicator pin; orient selector card so that
desired voltage is readable at the bottom; orient indicator
pin to point up when desired voltage is readable at bottom
(note that when indicator pin is fixed, successive voltages
are selected by rotating the card 90° clockwise); insert
voltage selector card into housing, printed side of card
facing forward toward IEC connector and edge containing
the desired voltage first; replace cover, and verify that
indicator pin shows the desired voltage.
3. When the fuse holder is installed in the single fuse
position, apply the screwdriver as shown and gently
pry up. Use screwdriver as shown, do not use fingers.
Voltage Selector Card Orientation
0
0
0
2
1
0
4
2 3
3
2
0
4
0
1
0
1
0
0
2 4
2
1 0
0
0
0
1
2 3
2 3
0
1
0
0
2
120V
100V
230V
2
2
1
When the fuse holder is installed in the dual fuse
position, it will normally release as soon as the
door is opened.
2
4
0
240V
125
Catalog 1654001
Revised 05-07
Dimensions are in inches and
millimeters unless otherwise
specified. Values in italics
are metric equivalents.
Dimensions are shown for
reference purposes only.
Specifications subject
to change.
USA Cust. Svc.: 1-800-468-2023
CORCOM Prods: 1-847-680-7400
Germany:
49-89-6089-0
www.corcom.com
www.tycoelectronics.com
CORCOM Product Guide
Power Entry Module with Optional RFI Power Line Filters for General and
Medical Applications (Continued)
M Series
Specifications
Electrical Schematics – Unfiltered Models
Maximum leakage current,each line-to-ground
HM
FM
XM/ZM
2µA
.25 mA
.30 mA
@ 120 VAC 60 Hz:
@ 250 VAC 50 Hz:
5µA
.50 mA
.50 mA
Hipot rating (one minute):
1500 VAC
line-to-ground:
line-to-line
1450 VDC
line-to-load (switch off) Unfiltered only
2500 VAC
Operating frequency:
50/60 Hz
VM (1-Voltage)
Rated voltage (max.):
Power On/Off
Note 3
Neutral
K
K
L
L
Note 2
120V
Hot
G
Customer
Transformer Primaries
250 VAC
Operating voltages:
100, 120, 220/ 240 VAC
Switch:
Double-insulated, rated for
100,000 operations at full load
at 70 Amps inrush current.
Fuse (not included):
Reversible fuseholder, accepts
one 1/4" x 1-1/4" fuse
or two 5 x 20 mm fuses
Terminals:
VM (2-Voltage)
Neutral
240V
120V
Power On/Off
Note 3
A
A
H
K
Note 2
B
120V
B
120V
Note 1
C
C
D
D
E
E
F
F
120V
Hot
J
L
Note 1
120V
F
Note 4
Customer
Transformer Primaries
G
.110 [2.79] terminals
Minimum insertion loss in dB:
VM (4-Voltage)
Line-to-ground in 50 ohm circuit
Current
Rating
HM
5A
FM
05A
XM
3A
ZM
3A
.01
.05
-
-
Frequency-MHz
.15
.5
1
5
10
30
14
22
17
Neutral
-
-
18
14
21
19
26
22
40
45
2
13
23
40
46
44
44
44
15
29
39
46
43
40
40
40
Frequency-MHz
.02 .03 .05 .07 .15 .5 1
Hot
Note 1:
Note 2:
Note 3:
Note 4:
5
10
30
-
-
-
5
34
62 68 60 50
40
5
13
28
37
55
75 75 62 54
44
230V
240V
A
A
H
K
Note 2
20V
100V
B
Note 1
40
Line-to-line in 50 ohm circuit
Current
Rating
XM
03A
ZM
3A
120V
100V
Power On/Off
Note 3
J
L
Note 1
C
C
D
D
E
E
F
F
G
120V
Customer
Transformer Primaries
Jumpers required if no input filter is used.
Provision for dual European style fusing.
On/off switch present only with "S" suffix.
When using a center-tapped transformer, the C-F winding should
be the low voltage (high current) winding and must be capable of
handling the full primary current in the 120V position.
126
Catalog 1654001
Revised 05-07
Dimensions are in inches and
millimeters unless otherwise
specified. Values in italics
are metric equivalents.
Dimensions are shown for
reference purposes only.
Specifications subject
to change.
USA Cust. Svc.: 1-800-468-2023
CORCOM Prods: 1-847-680-7400
Germany:
49-89-6089-0
www.corcom.com
www.tycoelectronics.com
CORCOM Product Guide
Power Entry Module with Optional RFI Power Line Filters for General and
Medical Applications (Continued)
M Series
Electrical Schematics - Filtered Models
Case Styles – Unfiltered Models
FM & HM (1-Voltage)
6VM1 (IEC Connector, Selectable Fuseholder)
Power On/Off
Note 2
Neutral
H
USE ONLY WITH
250V FUSES
B
Note 1
C
DISCONNECT POWER
BEFORE REPLACING FUSES
Note 3
E
D
B
J
A
F
Power Entry Modules
Phase
G
6VM1C (IEC Connector, Selectable Fuseholder, Snap-in)
FM & HM (4-Voltage)
120V
100V
Power On/Off
Note 1
H
K
Phase
100V
B
Note 4
Note 3
J
L
Note 4
C
DISCONNECT POWER
BEFORE REPLACING FUSES
20V
A
A
Note 2
Neutral
USE ONLY WITH
250V FUSES
230V
240V
D
A
C
C
D
D
E
E
F
F
G
Customer
Transformer Primaries
E
120V
6VM1S (IEC Connector, DPST On/Off Switch, Selectable
Fuseholder)
XM & ZM (1-Voltage)
USE ONLY WITH
250V FUSES
Power On/Off
Neutral
C
DISCONNECT POWER
BEFORE REPLACING FUSES
Note 2
H
B
Note 1
E
D
B
A
J
F
Phase
G
6VM1SC (IEC Connector, DPST On/Off Switch,
Selectable Fuseholder, Snap-In)
XM & ZM (4-Voltage)
120V
100V
Neutral
Power On/Off
Note 2
USE ONLY WITH
250V FUSES
230V
240V
A
A
Note 4
H
K
100V
B
J
L
Note 4
C
C
D
D
E
E
F
F
G
Customer
Transformer Primaries
120V
E
D
A
Note 1
Phase
C
DISCONNECT POWER
BEFORE REPLACING FUSES
20V
Recommended Panel Cutout (Snap-In Only)
0.13
R
3.30
Note 1:
Note 2:
Note 3:
Note 4:
Provision for dual fusing (Euro standard)
Power on/off switch with suffix "S" only
HM models without line-to-ground capacitors
Models HM4, FM4, XM4, and ZM4 have added terminals K and L.
External switch or jumper must be placed from K to H and L to J.
230V Nomenclature relates to pending European CENELEC agreement.
1.145
29.08
F
Typical dimensions:
Mounting Holes: .155 [3.94] Dia. (2) with .279 [7.09] Dia. x 82˚ Countersunk.
Panel Thickness: .06 - .09 [1.53 -2.29]
All mounting holes countersunk.
127
Catalog 1654001
Revised 05-07
Dimensions are in inches and
millimeters unless otherwise
specified. Values in italics
are metric equivalents.
Dimensions are shown for
reference purposes only.
Specifications subject
to change.
USA Cust. Svc.: 1-800-468-2023
CORCOM Prods: 1-847-680-7400
Germany:
49-89-6089-0
www.corcom.com
www.tycoelectronics.com
CORCOM Product Guide
Power Entry Module with Optional RFI Power Line Filters for General and
Medical Applications (Continued)
M Series
Case Styles - Unfiltered Models (cont'd)
Case Styles - Filtered Models
6VM2 & 6VM4 (IEC Connector, Voltage Selector,
3EXM1S & 3EZM1S (IEC Connector, DPST On/Off
Switch, Selectable Fuseholder)
Selectable Fuseholder)
USE ONLY WITH
250V FUSES
DISCONNECT POWER
BEFORE REPLACING FUSES
G
100V
120V
230V
240V
Thread
6-32 x 1/4
C
1.13±.020
28.7±.508
E
D
1.88±.020
47.8±.508
3.09
Max.
78.49
B
USE ONLY WITH
250V FUSES
A
C
DISCONNECT POWER
BEFORE REPLACING FUSES
D
B
A
6VM4C (IEC Connector, Voltage Selector, Selectable
E
Fuseholder, Snap-In)
USE ONLY WITH
250V FUSES
DISCONNECT POWER
BEFORE REPLACING FUSES
100V
120V
230V
240V
C
D
A
3EXM4 & 3EZM4 (IEC Connector, Voltage Selector,
Selectable Fuseholder)
E
G
Thread
6-32 x 1/4
6VM4C.ai
6VM2S & 6VM4S (IEC
Connector, DPST On/Off Switch,
Voltage Selector, Selectable Fuseholder)
USE ONLY WITH
250V FUSES
DISCONNECT POWER
BEFORE REPLACING FUSES
1.13±.020
28.7±.508
1.88±.020
47.8±.508
100V
120V
230V
240V
C
3.09
Max.
78.49
USE ONLY WITH
250V FUSES
DISCONNECT POWER
BEFORE REPLACING FUSES
E
D
B
A
100V
120V
230V
240V
C
D
B
A
E
6VM4SC (IEC Connector, DPST On/Off Switch, Voltage
Selector, Selectable Fuseholder, Snap-In)
USE ONLY WITH
250V FUSES
100V
120V
DISCONNECT POWER
BEFORE REPLACING FUSES
230V
240V
3EXM4S & 3EZM4S (IEC Connector, DPST On/Off
Switch, Voltage Selector, Selectable Fuseholder)
C
B
A
G
Thread
6-32 x 1/4
E
1.17±.020
29.7±.508
1.88±.020
47.8±.508
3.09
Max.
78.49
USE ONLY WITH
250V FUSES
DISCONNECT POWER
BEFORE REPLACING FUSES
100V
120V
230V
240V
D
B
A
C
E
128
Catalog 1654001
Revised 05-07
Dimensions are in inches and
millimeters unless otherwise
specified. Values in italics
are metric equivalents.
Dimensions are shown for
reference purposes only.
Specifications subject
to change.
USA Cust. Svc.: 1-800-468-2023
CORCOM Prods: 1-847-680-7400
Germany:
49-89-6089-0
www.corcom.com
www.tycoelectronics.com
CORCOM Product Guide
Power Entry Module with Optional RFI Power Line Filters for General and
Medical Applications (Continued)
M Series
Case Styles - Filtered Models (cont'd)
5EHM4 & 5EFM4 (IEC Connector, DPST On/Off Switch,
Selectable Fuseholder)
5EHM1 & 5EFM1 (IEC Connector, Selectable
Fuseholder)
USE ONLY WITH
250V FUSES
DISCONNECT POWER
BEFORE REPLACING FUSES
USE ONLY WITH
250V FUSES
C
E
E
Power Entry Modules
5EFM4C (IEC Connector, Voltage Selector, Selectable
Fuseholder)
5EFM1C (IEC Connector, Selectable Fuseholder)
USE ONLY WITH
250V FUSES
DISCONNECT POWER
BEFORE REPLACING FUSES
A
C
D
B
A
DISCONNECT POWER
BEFORE REPLACING FUSES
D
B
A
100V
120V
230V
240V
USE ONLY WITH
250V FUSES
100V
120V
DISCONNECT POWER
BEFORE REPLACING FUSES
230V
240V
A
C
D
D
C
E
E
5EHM1S & 5EFM1S (IEC Connector, DPST On/Off
Switch, Selectable Fuseholder)
5EHM4S & 5EFM4S (IEC Connector, DPST On/Off
Switch, Voltage Selector, Selectable Fuseholder)
USE ONLY WITH
250V FUSES
C
USE ONLY WITH
250V FUSES
DISCONNECT POWER
BEFORE REPLACING FUSES
DISCONNECT POWER
BEFORE REPLACING FUSES
E
D
B
A
100V
120V
230V
240V
D
B
A
C
E
5EFM1SC (IEC Connector, DPST On/Off Switch,
Selectable Fuseholder)
USE ONLY WITH
250V FUSES
DISCONNECT POWER
BEFORE REPLACING FUSES
A
D
C
E
Typical dimensions:
Torque: 7 in. lb max.
Holes: .055 [1.40] Dia. ±.004 [±.10] except solder lug ground tap with wire wrap.
Mounting Holes: .155 [3.94] Dia.
All parts typical.
Note: Mounting holes on tabs are countersunk and take a #6 flathead screw.
129
Catalog 1654001
Revised 05-07
Dimensions are in inches and
millimeters unless otherwise
specified. Values in italics
are metric equivalents.
Dimensions are shown for
reference purposes only.
Specifications subject
to change.
USA Cust. Svc.: 1-800-468-2023
CORCOM Prods: 1-847-680-7400
Germany:
49-89-6089-0
www.corcom.com
www.tycoelectronics.com
CORCOM Product Guide
Power Entry Module with Optional RFI Power Line Filters for General and
Medical Applications (Continued)
M Series
Case Styles - Filtered Models (cont'd)
Case Dimensions
5EFM4SC (IEC Connector, DPST On/Off Switch, Voltage
Selector, Selectable Fuseholder)
USE ONLY WITH
250V FUSES
100V
120V
DISCONNECT POWER
BEFORE REPLACING FUSES
230V
240V
3EXM1S
3EZM1S
3EXM4
3EZM4
3EXM4S
3EZM4S
5EFM1
5EHM1
A
C
D
A
(max)
Part No.
E
5EFM1C
5EFM1S
5EHM1S
5EFM1SC
5EFM4
5EHM4
5EFM4C
5EFM4S
5EHM4S
Recommended Panel Cutout
5EFM4SC
*Blind insert
XM and ZM
Models only
+
*4S Models 1.17 .020
29.7 + .508
+
*1S & 4 models 1.13 .020
28.7 + .508
0.13
R
3.30
6VM1
1.88 + .020
47.8 + .508
Holes (2)
.570
14.5
.170
Dia.
4.32
.175
4.45
6VM1C
6VM1S
1.145
29.08
6VM1SC
6VM2
6VM4
F
B
6VM4C
Note: Snap-in models allow front mount only.
XM and ZM models allow back mount only.
FM and HM models allow front or back mounting.
Accessories for M series include interconnection assembly, medical standoff
bracket, voltage selector cards, and insulating shroud. See page 142.
6VM2S
6VM4S
6VM4SC
All mounting holes countersunk.
4.17
105.9
3.88
98.6
4.65
118.1
3.39
86.1
2.56
65.0
4.17
105.9
3.34
84.8
3.88
98.6
3.04
77.2
4.65
118.1
3.82
97.0
3.39
86.1
2.56
86.1
4.17
105.9
3.34
84.8
3.88
98.6
3.04
98.6
4.65
118.1
3.82
97.0
B
±0.01
±0.038
3.62
91.9
3.32
84.3
4.1
104.1
2.84
72.1
C
D
E
(max) (max) (max)
1.14
29.0
1.14
29.0
1.14
29.0
1.14
29.0
1.14
—
29.0
3.62 1.14
91.9 29.0
1.14
—
29.0
3.32 1.14
84.3 29.0
1.14
—
29.0
4.1
1.14
104.1 29.0
1.14
—
29.0
2.84 1.14
72.1 29.0
1.14
—
29.0
3.62 1.14
91.9 29.0
1.14
—
29.0
3.32 1.14
84.3 29.0
1.14
—
29.0
4.1
1.14
104.1 29.0
1.14
—
29.0
3.22
81.8
2.92
74.2
3.72
94.5
2.44
62.0
2.44
62.0
3.22
81.8
3.27
83.1
2.92
74.2
2.92
74.2
3.7
94.0
3.7
94.0
2.44
62.0
2.44
62.0
3.22
81.8
3.27
83.1
2.92
74.2
2.92
74.2
3.72
94.5
3.7
94.0
1.72
43.7
1.72
43.7
1.72
43.7
2.19
55.6
2.19
55.6
2.19
55.6
2.19
55.6
2.19
55.6
2.19
55.6
2.19
55.6
2.19
55.6
1.45
36.8
1.45
36.8
1.45
36.8
1.45
36.8
1.45
36.8
1.45
36.8
1.45
36.8
1.45
36.8
F
G
3.28
83.8
2.98
75.7
3.76
95.5
2.5
63.5
2.49
63.2
3.28
83.3
3.27
83.1
2.98
75.7
2.97
75.4
3.76
95.5
3.75
95.3
2.5
63.5
2.5
63.2
3.28
83.3
3.27
83.1
2.98
75.7
2.97
75.4
3.76
95.5
3.75
95.3
3.3
83.8
2.99
75.9
3.8
96.5
—
—
—
—
—
—
—
—
130
Catalog 1654001
Revised 05-07
Dimensions are in inches and
millimeters unless otherwise
specified. Values in italics
are metric equivalents.
Dimensions are shown for
reference purposes only.
Specifications subject
to change.
USA Cust. Svc.: 1-800-468-2023
CORCOM Prods: 1-847-680-7400
Germany:
49-89-6089-0
www.corcom.com
www.tycoelectronics.com
CORCOM Product Guide
Power Entry Module with Optional RFI Power Line Filters for General and
Medical Applications (Continued)
M Series
FILTERED MODELS
Part
Number
Available Voltage
Selection
Positions†
1
4
4
1
4
4
1
1
4
4
1
1
1
1
4
4
4
4
DPST
On/Off
Switch
•
•
•
•
•
•
•
•
•
•
Mounting
Style
Flange
Flange
Flange
Flange
Flange
Flange
Flange
Flange
Flange
Flange
Flange
Snap-in
Flange
Snap-in
Flange
Snap-in
Flange
Snap-in
Power Entry Modules
3EXM1S
3EXM4
3EXM4S
3EZM1S
3EZM4
3EZM4S
5EHM1
5EHM1S
5EHM4
5EHM4S
5EFM1
5EFM1C
5EFM1S
5EFM1SC
5EFM4
5EFM4C
5EFM4S
5EFM4SC
RFI
Current Rating Current Rating
@120VAC
@250VAC
Filter
Type
(Amps)
(Amps)
SMPS FCC-B1
3
2
SMPS FCC-B1
3
2
SMPS FCC-B1
2
3
SMPS EN55022-B2
2
3
SMPS EN55022-B2
3
2
SMPS EN55022-B2
3
2
5
4
Medical3
Medical3
5
4
5
4
Medical3
Medical3
5
4
General Purpose‡
5
4
5
4
General Purpose‡
5
4
General Purpose‡
General Purpose‡
5
4
General Purpose‡
5
4
General Purpose‡
5
4
5
4
General Purpose‡
General Purpose‡
5
4
• Includes DPST switch
UNFILTERED MODELS
Part
Number
6VM1
6VM1C
6VM1S
6VM1SC
6VM2
6VM2S
6VM4
6VM4C
6VM4S
6VM4SC
Current Rating
@120VAC
(Amps)
6
6
6
6
6
6
6
6
6
6
Current Rating
250VAC
(Amps)
6
6
4
4
6
6
6
6
4
4
Available Voltage
Selection
Position†
1
1
1
1
2
2
4
4
4
4
DPST
On/Off
Switch
•
•
•
•
•
Mounting
Style
Flange
Snap-in
Flange
Snap-in
Flange
Flange
Flange
Snap-in
Flange
Snap-in
• Includes DPST switch
1-120V/240V Fixed, 2 - 120/240V Selectable, 4- 100, 120, 230, 240V selectable
1
Emissions filter for switching power supply applications where FCC-B level requirements must be met
2
Emissions filter for switching power supply applications where En5502-B level requirements must be met
3
Medical filter for very low leakage UL544, UL2601 and EN60601 health care applications
‡
General purpose filer for susceptibility applications
†
131
Catalog 1654001
Revised 05-07
Dimensions are in inches and
millimeters unless otherwise
specified. Values in italics
are metric equivalents.
Dimensions are shown for
reference purposes only.
Specifications subject
to change.
USA Cust. Svc.: 1-800-468-2023
CORCOM Prods: 1-847-680-7400
Germany:
49-89-6089-0
www.corcom.com
www.tycoelectronics.com