QUANTUM QUINTENZ精密型时钟QXTO-8系列

3UHFLVLRQ&U\VWDO&ORFN2VFLOODWRU
6HULHV
QX T O-8
)HDWXUHV
TO-8 package
Hermetically sealed enclosure
HC-MOS technology
Wide temperature range
MIL-STD Screening
7\SLFDO$SSOLFDWLRQV
Test Equipment
Clock
rough environmental conditions
%DVHPRGHOVFDQEHPRGLILHGWR\RXUVSHFLILFDWLRQ
ZLWKLQWKHSHUIRUPDQFHUDQJHVVKRZQEHORZ
*HQHUDO3HUIRUPDQFHRI4;72VHULHV
)UHTXHQF\UDQJH
+)2XWSXW
2XWSXW/HYHO
6\PPHWU\
)DOO5LVHWLPH
)UHTXHQF\VWDELOLW\
)UHTXHQF\RYHUDOOWROHUDQFHV
$JLQJ
2SHUDWLQJWHPSHUDWXUHUDQJH
6WRUDJHWHPSHUDWXUHUDQJH
(QDEOHGLVDEOHIXQFWLRQ
6XSSO\YROWDJH
&XUUHQWFRQVXPSWLRQ
(QFORVXUH
:HLJKW
DYDLODEOH
“
“
IURP
W\S
WR
+&02677/FRPS
9!
#9
0+]
9
QV
SSP
SSP
ƒ&
ƒ&
H or open = enable, L = disable
9
72SLQ
P$
PP
J
ILUVW\HDU
“
)XUWKHUIUHTXHQFLHVWROHUDQFHVDQGVSHFLILFDWLRQVXSRQUHTXHVWSRVVLEOH
Notes:
1)
Including adj. tol., tol. vs temperature range, vs supply voltage change, vs. load change and 15 years aging
2)
depends on specification; after 15 days continuous operation
3)
depends on nominal frequency
QUINTENZ Hybridtechnik • Eichenstr. 15 • D-82061 Neuried • Tel.+49(0)89/7592252 • Fax+49(0)89/7592545
Distribution: UNVERDROSS-TECHNIK • Am Pfeifenberg 5 • D-82237 Wörthsee • Tel.+49(0)8143/6157 • Fax+49(0)8143/6162
16.07.2004
3UHFLVLRQ&U\VWDO&ORFN2VFLOODWRU
6HULHV
QX T O-8
'UDZLQJ
4;726 SMD-Version
4;72
13,1
13,5
0,8
45°
13,1
7,1
Pin 8
Pin 8
Pin 1
Pin 1
connections
1
2
3
4
5
6
7
8
EN ( H-active)
int. X-tal
HF out
GND
n.c.
int. X-tal
n.c.
Vcc
12,7
Pin 1
1, 5
± 1,0
9,0 max
0,6
7,5
0,6
max
2,72
Pin
2,8
0,45
Pad layout (proposal)
Top view
0,45
DOOGLPHQVLRQVLQPP
0DUNLQJ
Manufacturer name, Article/Series code,
Center Frequency, date code and series no.
(QYLURQPHQWDOFRQGLWLRQV
7KHFU\VWDORVFLOODWRUVDUHDSSURYHGLQWKHIROORZLQJHQYLURQPHQWDOFRQGLWLRQV
7HVW
Sealing test
Shock
Vibration, sinus
Thermal Shock
,(&
0,/67'
7HVWFRQGLWLRQV
2-17
883E - Meth. 1014
Fine leak: A1 2 x 10-8
2-27
202F - Meth. 213B E: 1000g; 0,5ms;half-sine
2-6
202F - Meth. 204D:
20..2000 Hz 20g; 20 min/axis
2-14
883E - Meth. 1014 A: 100°C to 0°C, water,15 cycles
(QGXUDQFHWHVWVEXUQLQK#ƒ&DJLQJGD\V#ƒ&!GD\V#ƒ&DSSURYDOVDPSOHV
7KHRVFLOODWRUK\EULGPLFURFLUFXLWGHVLJQDQGFRQVWUXFWLRQLVLQDFFRUGDQFHZLWKDSSOLFDEOHGHVLJQ
DQGFRQVWUXFWLRQUHTXLUHPHQWV
7KHILQDOWHVWSURFHGXUHLQFOXGHVDOOSRLQWVRIHOHFWULFDOVSHFLILFDWLRQHVSHFLDOO\DWHVWRI
-frequency adjustment – calibration
-frequency stability vs. operating temperature range
-long-term stability measurement
-output waveform
QUINTENZ Hybridtechnik • Eichenstr. 15 • D-82061 Neuried • Tel.+49(0)89/7592252 • Fax+49(0)89/7592545
Distribution: UNVERDROSS-TECHNIK • Am Pfeifenberg 5 • D-82237 Wörthsee • Tel.+49(0)8143/6157 • Fax+49(0)8143/6162
Page 2
16.07.2004