规格书编号 SPEC NO : 产品规格书 SPECIFICATION CUSTOMER 客 户: SAW FILTER PRODUCT 产 品: MODEL NO 型 号: HDVF45A1Dc SIP5Dc PREPARED 编 制: CHECKED 审 核: APPROVED 批 准: D A T E 日 期: 2008-11-28 客户确认 CUSTOMER RECEIVED: 审核 CHECKED 批准 APPROVED 日期 DATE 无锡市好达电子有限公司 Shoulder Electronics Limited www.shoulder.cn Tel:0755-82916880 Fax:0755-82916881 E-mail:[email protected] Page 1 of 9 SAW FILTER HDVF45A1Dc SIP5Dc 更改历史记录 History Record 更改日期 Date www.shoulder.cn 规格书编号 Spec. No. 产品型号 Part No. 客户产品型号 Customer No. Tel:0755-82916880 Fax:0755-82916881 更改内容描述 Modify Content E-mail:[email protected] 备注 Remark Page 2 of 9 SAW FILTER HDVF45A1Dc SIP5Dc 1.SCOPE SHOULDER’s SAW filter series have broad line up products meeting all broadcast standard including NTSC,PAL and SECAM systems. These filters are composed of two interdigital transducers on a single-crystal. piezoelectrical chip. they are used in electronic equipments such as TV and so on. 2.Construction 2.1 Dimension and materials Manufacturer’s name : SHOULDER ELECTRONICS Co. LTD(CHINA) Type : VF45A1Dc YY:year WW:week www.shoulder.cn Tel:0755-82916880 Fax:0755-82916881 E-mail:[email protected] Page 3 of 9 SAW FILTER HDVF45A1Dc SIP5Dc 2.2. Circuit construction, measurement circuit 3.Characteristics Items Standard atmospheric conditions Conditions Unless otherwise specified , the standard rang of atmospheric conditions for making measurements and tests is as follows; Ambient temperature : 15℃ to 35℃ Relative humidity : 25% to 85% Air pressure : 86kPa to 106kPa Operating temperature rang Operating temperature rang is the rang of ambient temperatures in which the filter can be operated continuously. -10℃ ~ +60℃ Storage temperature rang Storage temperature rang is the rang of ambient temperatures at which the filter can be stored without damage. Conditions are as specified elsewhere in these specifications. -40℃ ~ +70℃ Reference temperature +25℃ www.shoulder.cn Tel:0755-82916880 Fax:0755-82916881 E-mail:[email protected] Specifications There shall be no damage. Page 4 of 9 SAW FILTER HDVF45A1Dc SIP5Dc 3.1 Maximum Rating DC voltage VDC 12 V 3.2 Electrical Characteristics Source impedance Zs=50Ω Load impedance ZL=2kΩ//3pF Item Freq Insertion attenuation 44.06MHz Reference level 45.81MHz 42.23MHz Relative attenuation 41.31MHz 39.81MHz 47.31MHz 35.06~39.81MHz Sidelobe 47.31~55.06MHz Reflected wave signal suppression 1.1 us … 6.0 us after main pulse (test pulse 250 ns , carrier frequency 44.06 MHz) Feedthrough signal suppression 1.2 us … 1.1 us after main pulse (test pulse 250 ns , carrier frequency 44.06 MHz) Group delay ripple (p-p) Temperature coefficient of frequency Between any terminals min typ 10.0 12.0 14.0 dB 4.4 0.7 25.0 42.0 40.0 36.0 35.0 5.9 2.2 35.0 55.0 51.0 42.0 40.0 7.4 3.7 - dB dB dB dB dB dB dB 40.0 52.0 dB 45.0 55.0 dB - 50 -72 3.3 Environmental Performance Characteristics Item Condition High The specimen shall be store at a temperature of temperature 80±2℃ for 96±4h. Then it shall be subjected to standard atmospheric conditions for 1h, after which measurement shall be made within 1h. Low The specimen shall be store at a temperature of temperature -20±3℃ for 96±4h. Then it shall be subjected to standard atmospheric conditions for 1h, after which measurement shall be made within 1h. Humidity The specimen shall be store at a temperature of 40±2℃ with relative humidity of 90% to 96% www.shoulder.cn Tel:0755-82916880 Fax:0755-82916881 TA=25℃ max E-mail:[email protected] - ns Ppm/k Specifications Mechanical characteristics and specifications in electrical characteristics shall be satisfied. There Page 5 of 9 SAW FILTER Thermal shock Resistance to Soldering heat HDVF45A1Dc SIP5Dc be no for 96±4h. Then it shall be subjected to standard shall atmospheric conditions for 1h, after which excessive change in appearance. measurement shall be made within 1h. The specimen shall be subjected to 8 continuous cycles each as shown below. Then it shall be subjected to standard atmospheric conditions for 1h, after which measurement shall be made within 1h. Temperature Duration 1 +25 ℃=>-40 ℃ 0.5h 2 -40 ℃ 4h 3 -40 ℃=>+85 ℃ 2h 4 +85 ℃ 4h 5 +85 ℃=>+25 ℃ 0.5h 6 +25 ℃ 1h Reflow soldering method Peak: 255 ±5 ℃, 220 ±5 ℃, 40s At electrode temperature of the specimen. The specimen shall be passed through the reflow furnace with the condition shown in the above profile for 1 time. The specimen shall be stored at standard atmospheric conditions for 1h, after which the measurement shall be made. Test board shall be 1.6 mm thick. Base material shall be glass fabric base epoxy resin. Solder ability Immerse the pins melt solder at 260℃+5/-0℃ More then 95% of for 5 sec. total area of the pins should be covered with solder www.shoulder.cn Tel:0755-82916880 Fax:0755-82916881 E-mail:[email protected] Page 6 of 9 SAW FILTER HDVF45A1Dc 3.4 Mechanical Test Items Conditions Vibration 600-3300rpm amplitude 1.5mm 3 directions 2 H each Drop On maple plate from 1 m high 3 times Lead pull Pull with 1 kg force for 30 seconds Lead bend 90o bending with 500g weigh 2 times 3.5 Voltage Discharge Test Item Condition Surge Between any two electrode SIP5Dc Specifications There shall be no damage. Specifications There shall be no damage www.shoulder.cn Tel:0755-82916880 Fax:0755-82916881 E-mail:[email protected] Page 7 of 9 SAW FILTER HDVF45A1Dc SIP5Dc 3.6 Frequency response www.shoulder.cn Tel:0755-82916880 Fax:0755-82916881 E-mail:[email protected] Page 8 of 9 SAW FILTER www.shoulder.cn Tel:0755-82916880 HDVF45A1Dc Fax:0755-82916881 E-mail:[email protected] SIP5Dc Page 9 of 9