CORCOM Product Guide The CHAMELEON Adaptable Module for General Purpose, DC Applications P Series UL Recognized CSA Certified TUV Approved P Series Specifications The DC version of the “P Series” power entry module offers full flexibility of design in the most compact package. It is a general purpose filter specifically designed for DC applications up to 80VDC. This module comes in snap-in or flange mount versions for easy mounting. It also allows for a single or dual fuse option. Hipot rating (one minute): line-to-ground line-to-line The DC version of the “P Series” was designed to address the increasing demand for filtering on central office equipment and customer premises equipment, but not restricted to this type of equipment. Some examples include routers, desktop servers and switches multiplexors, aggregators, concentrators, etc. The DC versions of the P Series mates with a standard MOLEX connector (HCS Series) which is readily available and better prevents accidental connection to AC power. 2250 VDC 1450 VDC Fuseholder: Accepts one or two fuses* 1/4" x 1 1/4" or 5 x 20 mm Rated voltage (max): Terminals: 80 VDC .187 x .032 [4.8 x .81] terminal tabs Operating Ambient Temperature Range: (@ rated current Ir) -10˚C to +40˚C In an ambient, Ta, higher than +40˚C, the maximum 85 - Ta operating current, Io, is as follows: Io = Ir 45 * Conversion clip provided on fuseholder for single fuse models. Minimum insertion loss in dB: Electrical Schematic LINE LOAD Line-to-ground in 50 ohm circuit Current Frequency-MHz 1 3 Rating .03 .1 .15 .5 7 17 21 27 33 40 03A 8 12 17 23 32 0 6A 10A 3 5 10 13 23 5 44 36 27 Line-to-line in 50 ohm circuit Current Frequency-MHz Rating .10 .15 .5 1 3 0 3A 2 4 12 15 30 0 6A 2 4 12 15 22 4 12 15 22 10A 2 5 48 42 42 10 50 44 35 10 50 55 55 30 32 30 27 30 45 45 45 154 Catalog 1654001 Revised 05-07 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. USA Cust. Svc.: 1-800-468-2023 CORCOM Prods: 1-847-680-7400 Germany: 49-89-6089-0 www.corcom.com www.tycoelectronics.com CORCOM Product Guide The CHAMELEON Adaptable Module for General Purpose, DC Applications (Continued) P Series Case Styles Case Dimensions PE Part No. A B C (max) (max) (max) PE 1.980 50.29 PS 1.240 31.50 C F A D E F +.008/-.000 +.20/-.00 +.008/-.000 +.20/-.00 2.130 2.310 54.10 58.67 1.120 28.45 2.201 55.91 1.575 40.00 2.130 2.310 54.10 58.67 1.120 28.45 2.201 55.91 — Ordering Information B ∅.06 Min. 1.54 P S 0 0 0 D D 3 D Shield Options D = Complete shield (DC version) PS Filter Current 3 = 3 amps 6 = 6 amps X = 10 amps C Fuse Options D = Dual fuse S = Single fuse B Input Voltage Select 0 = Single voltage A Recommended Panel Cutout .06 R Max. 1.52 E External Edge (1) .020 R Min. .508 D DC Filters Filter Type D = DC version Note: The external edges (installation side) on the "D" sides of the cutout should have a minimum .020" radius. For optional retention against extraction, the corresponding inner edge should be sharp, without paint or coatings. Edge coatings, including anodization are also discouraged for good shield contact. Switch Options 0 = No switch Extender Options 0 = None Mounting Style E = Mounting ears S = Snap-in Mating Connectors Red Black Part Numbers PE000DD3D PE000DD6D PE000DDXD PE000SD3D PE000SD6D PE000SDXD DC Connector No. PS000DD3D PS000DD6D PS000DDXD PS000SD3D PS000SD6D PS000SDXD GA210 CORCOM Part Number: GA210 - Custom connector assembly with 2, 36” long 18 gauge wires to mate with P Series filter MOLEX Component Part Numbers: 03-12-1026 Connector housing to mate with P Series 18-12-1222 Female Terminal (2 needed per housing) 155 Catalog 1654001 Revised 05-07 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. USA Cust. Svc.: 1-800-468-2023 CORCOM Prods: 1-847-680-7400 Germany: 49-89-6089-0 www.corcom.com www.tycoelectronics.com