MA-COM 10CFS1

CORCOM Product Guide
Switch with IEC Connector Compact Size
C Series
UL Recognized
CSA Certified
VDE Approved
CS
CFS
†Applies to Filtered models only.
C Series
Specifications
Two function power entry module combining a DPST switch
and an IEC 320 power line connector. Compact packaging
allows a smaller panel cutout with choice of snap-in or
flange mounting. Available with general purpose filtering (F
models - CFS, CFE), medical application filtering (H models
- CHS, CHE) or unfiltered (CS, CE). Terminals allow for easy
connection to any wiring scheme. Preconnected terminals
from line to switch are available (B Models - CBS, CBE) for
reducing OEM wiring time.
The medical versions (H models) are designed specifically
for health care applications. Their extremely low leakage
current allows compliance with UL544 and UL2601 as well
as CSA22.2 health care specifications for use with both
patient and non-patient care equipment. For more
information on UL544 or UL2601, see Appendix C.
Note: When using the models with an IEC connector,
remember that the leakage current of the companion line
cord, GA400, is more significant than that of the filter which may disqualify this line cord from use in patient care
applications.
Electrical Schematics
F Models (CFS, CFE)
LINE
LOAD
H Models (CHS, CHE)
LINE
LOAD
B Models (CBS, CBE)
Power On/Off
L
L
Note 1
Note 2
Note 1
Note 2
G
G
N
N
Note 1: Jumpers provided on CBS and CBE versions only.
Note 2: Location of optional filter
Maximum leakage current, each line to ground: †
F Models
H Models
@120 VAC 60 Hz:
.25 mA
2 µA
@250 VAC 50 Hz:
.40 mA
5 µA
Hipot rating (one minute):
line-to-ground
2250 VDC
line-to-line
1450 VDC
Operating frequency:
50/60 Hz
Rated voltage:
250 VAC
Operating voltages:
Switch:
Unfiltered Push-on Force:
115/230 VAC
Double-insulated rated
for 10,000 operations
at full load.
51 Amp inrush capability.
18 lb/80 N
Minimum insertion loss in dB:
Line-to-ground in 50 ohm circuit
Current
Frequency MHz
Rating
0.05 0.15 0.5
1
5
F Models
0 1A
10
26
46
48
46
0 3A
8
16
32
36
43
0 6A
4
11
22
27
36
10A
1
4
14
18
27
H Models
0 1A
16
21
37
44
26
14
31
32
26
9
0 3A
0 6A
4
10
22
23
19
10A
2
6
10
15
11
Line-to-line in 50 ohm circuit
Current
Frequency MHz
Rating
0.05 0.15 0.5
1
5
F Models
0 1A
1
3
13
28
62
0 3A
2
6
14
23
65
0 6A
2
6
14
27
46
10A
1
7
14
23
42
H Models
0 1A
1
6
13
29
38
0 3A
1
5
10
22
36
0 6A
1
5
14
20
31
10A
1
4
11
19
32
10
30
47
48
41
33
46
50
50
42
21
24
18
11
10
14
13
9
10
30
67
65
48
44
42
67
58
62
42
34
33
37
26
36
37
38
Resistor location for reference only.
110
Catalog 1654001
Revised 05-07
Dimensions are in inches and
millimeters unless otherwise
specified. Values in italics
are metric equivalents.
Dimensions are shown for
reference purposes only.
Specifications subject
to change.
USA Cust. Svc.: 1-800-468-2023
CORCOM Prods: 1-847-680-7400
Germany:
49-89-6089-0
www.corcom.com
www.tycoelectronics.com
CORCOM Product Guide
Switch with IEC Connector Compact Size (Continued)
C Series
Case Styles
CBS, CBE Pre-Connected Terminals
CE, CBE*
C
CBS, CBE Side View
B
F
A
CBS Rear View
Power Entry Modules
1.04
26.4
Max
.211 Max.
5.36
CBE Rear View
CS, CBS*
Case Dimensions
C
B
(max)
C
(max)
1.23
31.24
CE, CBE 1.74
44.2
CFS, CHS 1.23
31.24
CFE, CHE 1.74
44.2
.97
24.64
.97
24.64
2.53
64.26
2.53
64.26
1.62
41.17
1.62
41.17
1.62
41.17
1.62
41.17
CS, CBS
.211 Max.
5.36
B
A
A
Part No. (max)
CFE, CHE
D
E
F
± .006
± .152
± .006
± .152
± .006
± .152
1.06
1.54
26.92 39.12
1.06
1.54
26.92 39.12
1.12
1.54
28.5 39.12
1.12
1.54
28.5 39.12
—
1.417
36.0
—
1.417
36.0
C
Part Numbers
.211 Max.
5.36
B
F
A
01CFS1
03CFS1
06CFS1
10CFS1
10CS1
01CFE1
03CFE1
06CFE1
10CFE1
10CE1
01CHS1
03CHS1
06CHS1
10CHS1
10CBS1
01CHE1
03CHE1
06CHE1
10CHE1
10CBE1
CFS, CHS
Recommended Panel Cutout
C
D
.211 Max.
5.36
B
A
E
Typical Dimensions:
Mounting Holes: .13 [3.3] Dia. (2) with .23 Dia. x 90˚ Counter sunk
Terminals: .250 [6.35] (3)
Holes: .07 [1.8] Dia.
.06 R max
1.52
Panel Cutout for thickness of .031.098 [.8-2.5]. Not recommended for
plastic panels. For snap-in applications, the D sides of the cutout must
have a .02 [.508] radius on the installation side. Snap-in models allow
front mounting only.
F
111
Catalog 1654001
Revised 05-07
Dimensions are in inches and
millimeters unless otherwise
specified. Values in italics
are metric equivalents.
Dimensions are shown for
reference purposes only.
Specifications subject
to change.
USA Cust. Svc.: 1-800-468-2023
CORCOM Prods: 1-847-680-7400
Germany:
49-89-6089-0
www.corcom.com
www.tycoelectronics.com