VISHAY V12P12

New Product
V12P12
Vishay General Semiconductor
High Current Density Surface Mount
Trench MOS Barrier Schottky Rectifier
Ultra Low VF = 0.51 V at IF = 6 A
FEATURES
®
TMBS
eSMP
TM
Series
• Very low profile - typical height of 1.1 mm
• Ideal for automated placement
K
• Trench MOS Schottky technology
• Low forward voltage drop, low power
losses
1
2
• High efficiency operation
• Meets MSL level 1, per J-STD-020, LF maximum
peak of 260 °C
TO-277A (SMPC)
K
Cathode
Anode 1
• Component in accordance to RoHS 2002/95/EC
and WEEE 2002/96/EC
Anode 2
• Halogen-free
PRIMARY CHARACTERISTICS
IF(AV)
12 A
VRRM
120 V
IFSM
150 A
EAS
100 mJ
VF at IF = 12 A
0.63 V
TJ max.
150 °C
TYPICAL APPLICATIONS
For use in low voltage high frequency inverters,
freewheeling, dc-to-dc converters and polarity
protection applications.
MECHANICAL DATA
Case: TO-277A (SMPC)
Molding compound meets UL 94V-0 flammability
rating.
Base P/N-E3 - RoHS compliant, commercial grade
Base P/N-M3 - halogen-free and RoHS compliant,
commercial grade
Terminals: Matte tin plated leads, solderable per
J-STD-002 and JESD22-B102
E3 and M3 suffix meets JESD 201 class 1A whisker
test
MAXIMUM RATINGS (TA = 25 °C unless otherwise noted)
PARAMETER
SYMBOL
Device marking code
V12P12
UNIT
V1212
Maximum repetitive peak reverse voltage
VRRM
120
V
Maximum average forward rectified current (Fig. 1)
IF(AV)
12
A
Peak forward surge current 10 ms single half sine-wave
superimposed on rated load
IFSM
150
A
Non-repetitive avalanche energy
at IAS = 2.0 A, L = 50 mH, TJ = 25 °C
EAS
100
mJ
TJ, TSTG
- 40 to + 150
°C
Operating junction and storage temperature range
Document Number: 89094
Revision: 29-Jul-08
For technical questions within your region, please contact one of the following:
[email protected], [email protected], [email protected]
www.vishay.com
1
New Product
V12P12
Vishay General Semiconductor
ELECTRICAL CHARACTERISTICS (TA = 25 °C unless otherwise noted)
PARAMETER
TEST CONDITIONS
Breakdown voltage
Instantaneous forward voltage (1)
Reverse
IR = 1.0 mA
TA = 25 °C
IF = 6 A
IF = 12 A
TA = 25 °C
SYMBOL
TYP.
MAX.
UNIT
VBR
120 (minimum)
-
V
0.57
0.72
0.80
0.70
V
VF
IF = 6 A
IF = 12 A
TA = 125 °C
0.51
0.63
VR = 90 V
TA = 25 °C
TA = 125 °C
13
7
-
µA
mA
VR = 120 V
TA = 25 °C
TA = 125 °C
50
16
500
50
µA
mA
current (2)
IR
Notes:
(1) Pulse test: 300 µs pulse width, 1 % duty cycle
(2) Pulse test: Pulse width ≤ 40 ms
THERMAL CHARACTERISTICS (TA = 25 °C unless otherwise noted)
PARAMETER
Typical thermal resistance
SYMBOL
V12P12
UNIT
RθJA (1)
RθJL
60
4
°C/W
Note:
(1) Units mounted on recommended P.C.B. 1 oz. pad layout
ORDERING INFORMATION (Example)
PREFERRED P/N
UNIT WEIGHT (g)
PREFERRED PACKAGE CODE
BASE QUANTITY
V12P12-E3/86A
0.10
86A
1500
7" diameter plastic tape and reel
V12P12-E3/87A
0.10
87A
6500
13" diameter plastic tape and reel
V12P12-M3/86A
0.10
86A
1500
7" diameter plastic tape and reel
V12P12-M3/87A
0.10
87A
6500
13" diameter plastic tape and reel
www.vishay.com
2
DELIVERY MODE
For technical questions within your region, please contact one of the following:
[email protected], [email protected], [email protected]
Document Number: 89094
Revision: 29-Jul-08
New Product
V12P12
Vishay General Semiconductor
RATINGS AND CHARACTERISTICS CURVES
(TA = 25 °C unless otherwise noted)
100
Instantaneous Reverse Current (mA)
Average Forward Rectified Current (A)
14
Resistive or Inductive Load
12
10
8
6
TL Measured
at the Cathode Band Terminal
4
2
110
120
130
140
TA = 100 °C
1
0.1
0.01
150
TA = 25 °C
10
20
30
40
50
60
70
80
90
Lead Temperature (°C)
Percent of Rated Peak Reverse Voltage (%)
Figure 1. Maximum Forward Current Derating Curve
Figure 4. Typical Reverse Characteristics
11
100
10 000
D = 0.3
10
D = 0.2
9
8
D = 1.0
D = 0.1
7
TJ = 25 °C
f = 1.0 MHz
Vsig = 50 mVp-p
D = 0.5 D = 0.8
Junction Capacitance (pF)
Average Power Loss (W)
TA = 125 °C
0.001
0
100
6
5
T
4
3
2
D = tp/T
1
1000
100
tp
10
0
0
2
4
6
8
10
12
0.1
14
1
10
100
Average Forward Current (A)
Reverse Voltage (V)
Figure 2. Forward Power Loss Characteristics
Figure 5. Typical Junction Capacitance
100
100
Transient Thermal Impedance (°C/W)
Instantaneous Forward Current (A)
TA = 150 °C
10
TA = 150 °C
10
TA = 125 °C
1
TA = 100 °C
0.1
TA = 25 °C
0.01
0
0.1
0.2
0.3
0.4
0.5
0.6
0.7
0.8
0.9
1.0
Junction to Ambient
10
1
0.01
0.1
1
10
100
Instantaneous Forward Voltage (V)
t - Pulse Duration (s)
Figure 3. Typical Instantaneous Forward Characteristics
Figure 6. Typical Junction Capacitance
Document Number: 89094
Revision: 29-Jul-08
For technical questions within your region, please contact one of the following:
[email protected], [email protected], [email protected]
www.vishay.com
3
New Product
V12P12
Vishay General Semiconductor
PACKAGE OUTLINE DIMENSIONS in inches (millimeters)
TO-277A (SMPC)
0.187 (4.75)
0.175 (4.45)
0.016 (0.40)
0.006 (0.15)
K
0.262 (6.65)
0.250 (6.35)
0.242 (6.15)
0.238 (6.05)
0.026 (0.65) NOM.
2
1
0.047 (1.20)
0.039 (1.00)
0.171 (4.35)
0.167 (4.25)
0.146 (3.70)
0.134 (3.40)
Mounting Pad Layout
0.087 (2.20)
0.075 (1.90)
0.189
MIN.
(4.80)
0.189 (4.80)
0.173 (4.40)
0.186
MIN.
(4.72)
0.268
(6.80)
0.155 (3.94)
NOM.
0.030 (0.75) NOM.
0.049 (1.24)
0.037 (0.94)
0.050
MIN.
(1.27)
0.084 (2.13) NOM.
0.041
(1.04)
0.053 (1.35)
0.041 (1.05)
0.055
MIN.
(1.40)
Conform to JEDEC TO-277A
www.vishay.com
4
For technical questions within your region, please contact one of the following:
[email protected], [email protected], [email protected]
Document Number: 89094
Revision: 29-Jul-08
Legal Disclaimer Notice
Vishay
Disclaimer
All product specifications and data are subject to change without notice.
Vishay Intertechnology, Inc., its affiliates, agents, and employees, and all persons acting on its or their behalf
(collectively, “Vishay”), disclaim any and all liability for any errors, inaccuracies or incompleteness contained herein
or in any other disclosure relating to any product.
Vishay disclaims any and all liability arising out of the use or application of any product described herein or of any
information provided herein to the maximum extent permitted by law. The product specifications do not expand or
otherwise modify Vishay’s terms and conditions of purchase, including but not limited to the warranty expressed
therein, which apply to these products.
No license, express or implied, by estoppel or otherwise, to any intellectual property rights is granted by this
document or by any conduct of Vishay.
The products shown herein are not designed for use in medical, life-saving, or life-sustaining applications unless
otherwise expressly indicated. Customers using or selling Vishay products not expressly indicated for use in such
applications do so entirely at their own risk and agree to fully indemnify Vishay for any damages arising or resulting
from such use or sale. Please contact authorized Vishay personnel to obtain written terms and conditions regarding
products designed for such applications.
Product names and markings noted herein may be trademarks of their respective owners.
Document Number: 91000
Revision: 18-Jul-08
www.vishay.com
1