PolySwitch LVR devices help protect electric motors and transformers used in commercial and home appliances from damage caused by mechanical overloads, overheating, stall, lost neutral and other potentially harmful conditions. The LVR line-voltage product line of polymeric positive temperature coefficient (PPTC) devices includes components that are rated for line voltages of 120VAC and 240VAC, for up to 2A of operating current at 20°C. They help protect against damage caused by both overcurrent surges and overtemperature faults, offer low resistance, and are compatibly sized with fuse solutions. Unlike traditional fuses, PolySwitch devices do not require replacement after a fault event. After power has been removed and the overcurrent condition eliminated, the circuit is restored to normal operating condition. Compared to bimetal breakers, they offer greater flexibility, longer lifespan, and lower electromagnetic interference (EMI). The PolySwitch LVR devices’ resettable functionality and latching attributes make them a reliable, cost-effective circuit protection solution for both intermittent- and continuous-operation motor applications. Their low resistance, fast time-to-trip, and low profile help circuit designers provide a safe and dependable product, comply with regulatory agency requirements, and reduce warranty repair costs. PolySwitch Resettable Devices – Line-Voltage-Rated Devices PolySwitch Resettable Devices Line-Voltage-Rated Devices LVR/LVRL series are suitable for line-voltage applications up to a continuous operating voltage of 240VAC/120VAC. RoHS versions of all products are available. Benefits Features • Many product choices give engineers more design flexibility • Compatible with high-volume electronics assembly • RoHS compliant • Broadest range of radial-leaded resettable devices available in the industry • Assist in meeting regulatory requirements • Current ratings from 50mA to 2A • Higher voltage ratings allow use in new applications • Line voltage rating of 120VAC and 240VAC 10 • Agency recognition : UL, CSA, TÜV • Fast time-to-trip • Low resistance Applications • Electromagnetic loads • Medical equipment • Security and fire alarm systems • Game machines • Motors, fans and blowers • Test and measurement equipment • Industrial controls • POS equipment • Transformers • Lighting ballast • Satellite video receivers • USB hubs, ports and peripherals • Loudspeakers 139 Table L1 Product Series - Current Rating, Voltage Rating / Typical Resistance for LVR Devices Voltage Rating LVR 240VAC / 120VAC LVRL 120VAC Hold Current (A) 0.050 25.00Ω — 0.080 9.800Ω — 0.120 4.800Ω — 0.160 3.400Ω — 0.250 1.700Ω — 0.330 1.000Ω — 0.400 0.800Ω — 0.550 0.590Ω — 0.750 0.400Ω 0.325Ω 1.000 0.276Ω 0.224Ω 1.250 0.209Ω 0.148Ω 1.350 — 0.138Ω 2.000 0.110Ω 0.097Ω Table L2 Thermal Derating for LVR Devices [Hold Current (A) at Ambient Temperature (°C)] Maximum Ambient Temperature Part Number -20°C 0°C 20°C 25°C 40°C 50°C 60°C 70°C 85°C LVR005N 0.08 0.06 0.05 0.05 0.04 0.04 0.03 0.03 0.02 LVR008N 0.12 0.10 0.08 0.08 0.07 0.06 0.05 0.04 0.03 LVR012 0.18 0.15 0.12 0.12 0.10 0.09 0.07 0.06 0.04 LVR016 0.24 0.20 0.16 0.16 0.13 0.11 0.10 0.08 0.05 LVR025 0.38 0.32 0.25 0.25 0.21 0.18 0.15 0.13 0.09 LVR033 0.50 0.42 0.33 0.33 0.27 0.23 0.20 0.17 0.11 LVR040 0.61 0.51 0.40 0.40 0.33 0.28 0.24 0.20 0.14 LVR055 0.80 0.68 0.55 0.54 0.46 0.40 0.35 0.29 0.22 LVR075 1.23 0.98 0.75 0.74 0.60 0.56 0.49 0.45 0.41 LVR100 1.65 1.30 1.00 0.94 0.80 0.75 0.65 0.60 0.55 LVR125 2.06 1.63 1.25 1.20 1.00 0.94 0.81 0.75 0.69 LVR200 3.30 2.60 2.00 1.97 1.60 1.50 1.30 1.20 1.10 LVRL075 1.08 0.93 0.75 0.74 0.64 0.57 0.51 0.44 0.35 LVRL100 1.40 1.19 1.00 0.94 0.82 0.73 0.65 0.57 0.45 LVRL125 1.80 1.53 1.25 1.20 1.04 0.94 0.83 0.73 0.60 LVRL135 2.00 1.65 1.35 1.29 1.12 1.01 0.90 0.78 0.65 LVRL200 3.05 2.55 2.00 1.97 1.72 1.55 1.39 1.22 0.98 LVR/LVRL 10 Figure L1 Thermal Derating Curve for LVR Devices A = B = C = LVR075-LVR200 LVRL075-LVRL200 LVR005N-LVR055 Figure L1 180 A 170 % of rated hold and trip current 160 150 140 B C 130 120 110 100 90 80 70 60 A 50 C 40 30 -30 B -20 -10 0 10 20 30 40 Ambient Temperature (˚C) 140 RoHS Compliant, ELV Compliant 50 60 70 80 90 PolySwitch Resettable Devices – Line-Voltage-Rated Devices Table L3 Electrical Characteristics for LVR Devices* IH (A) IT (A) LVR005NK 0.05 0.12 LVR005NS 0.05 0.12 LVR008NK 0.08 0.19 LVR008NS 0.08 0.19 LVR012K 0.12 0.30 LVR012S 0.12 0.30 LVR016K 0.16 0.37 LVR016S 0.16 0.37 LVR025K 0.25 0.56 LVR025S 0.25 0.56 LVR033K 0.33 0.74 LVR033S 0.33 0.74 LVR040K 0.40 0.90 LVR040S 0.40 0.90 LVR055K 0.55 1.25 LVR055S 0.55 1.25 LVR075S 0.75 LVR100S 1.00 LVR125S 1.25 Part Number VMAX† Operating Interrupt (VAC) (VAC) IMAX† Interrupt (A) PD Typ (W) Max. Time-to-trip (A) (s) RMIN (Ω) RMAX (Ω) R1MAX (Ω) Lead Size [mm (AWG)] LVR/LVRL 240 265 1.0 120 135 20.0 240 265 1.0 120 135 20.0 240 265 1.2 120 135 20.0 240 265 1.2 120 135 20.0 240 265 1.2 120 135 20.0 240 265 1.2 120 135 20.0 240 265 2.0 120 135 20.0 240 265 2.0 120 135 20.0 240 265 3.5 120 135 20.0 240 265 3.5 120 135 20.0 240 265 4.5 120 135 20.0 240 265 4.5 120 135 20.0 240 265 5.5 120 135 20.0 240 265 5.5 120 135 20.0 240 265 7.0 120 135 20.0 240 265 7.0 120 135 20.0 1.50 240 265 2.00 240 265 2.50 240 265 12.5 0.9 0.25 10.0 18.500 31.000 65.000 [0.51mm(24)] 0.9 0.25 10.0 18.500 31.000 65.000 [0.51mm(24)] 0.9 0.40 10.0 7.400 12.000 26.000 [0.51mm(24)] 0.9 0.40 10.0 7.400 12.000 26.000 [0.51mm(24)] 1.0 0.60 15.0 3.000 6.500 12.000 [0.51mm(24)] 1.0 0.60 15.0 3.000 6.500 12.000 [0.51mm(24)] 1.4 0.80 15.0 2.500 4.100 7.800 [0.51mm(24)] 1.4 0.80 15.0 2.500 4.100 7.800 [0.51mm(24)] 1.5 1.25 18.5 1.300 2.100 3.800 [0.64mm(22)] 1.5 1.25 18.5 1.300 2.100 3.800 [0.64mm(22)] 1.7 1.65 21.0 0.770 1.240 2.600 [0.64mm(22)] 1.7 1.65 21.0 0.770 1.240 2.600 [0.64mm(22)] 2.0 2.00 24.0 0.600 0.970 1.900 [0.64mm(22)] 2.0 2.00 24.0 0.600 0.970 1.900 [0.64mm(22)] 3.4 2.75 26.0 0.450 0.730 1.450 [0.81mm(20)] 3.4 2.75 26.0 0.450 0.730 1.450 [0.81mm(20)] 7.5 2.6 3.75 18.0 0.316 0.483 0.839 [0.81mm(20)] 10.0 2.9 5.00 21.0 0.218 0.334 0.580 [0.81mm(20)] 3.3 6.25 23.0 0.165 0.253 0.440 [0.81mm(20)] LVR200S 2.00 4.00 240 265 20.0 4.5 10.00 28.0 0.089 0.131 0.221 [0.81mm(20)] LVRL075S 0.75 1.52 120 135 7.5 1.8 3.75 14.0 0.250 0.400 0.690 [0.81mm(20)] LVRL100S 1.00 2.00 120 135 10.0 2.2 5.00 13.6 0.179 0.269 0.470 [0.81mm(20)] LVRL125S 1.25 2.50 120 135 12.5 2.0 6.25 18.0 0.117 0.179 0.320 [0.81mm(20)] LVRL135S 1.35 2.70 120 135 13.5 2.8 6.75 20.0 0.109 0.167 0.300 [0.81mm(20)] LVRL200S 2.00 4.20 120 135 20.0 3.9 10.00 36.0 0.075 0.117 0.205 [0.81mm(20)] 10 Notes: : Hold current: maximum current device will pass without interruption in 20°C still air. IH : Trip current: minimum current that will switch the device from low resistance to high resistance in 20°C still air. IT VMAX Operating: Maximum continuous voltage device can withstand without damage at rated current. VMAX Interrupt : Under specified conditions this is the highest voltage that can be applied to the device at the maximum interrupt current. IMAX Interrupt : Maximum fault current device can withstand without damage at rated voltage. : Power dissipated from device when in the tripped state in 20°C still air. PD : Minimum resistance of device as supplied at 20°C unless otherwise specified. RMIN : Maximum resistance of device as supplied at 20°C unless otherwise specified. RMAX : Maximum resistance of device when measured one hour post trip at 20°C unless otherwise specified. R1MAX * Electrical characteristics determined at 20°C. † See Application Limitations on next page. RoHS Compliant, ELV Compliant 141 Warning : Application Limitations for the LVR Product Line 1) Users should independently evaluate the suitability of and test each product selected for their own application. 2) This product should not be used in an application where the maximum interrupt voltage or maximum interrupt current can be exceeded in a fault condition. Operation beyond the maximum ratings or improper use may result in device damage and possible electrical arcing and flame. 3) A PPTC device is not a fuse - it is a nonlinear thermistor that limits current. Under a fault condition all PPTC devices go into a high resistance state but do not open circuit, so hazardous voltage may be present at PPTC locations. 4) The devices are intended for protection against damage caused by occasional overcurrent or overtemperature fault conditions and should not be used when repeated fault conditions or prolonged trip events are anticipated. 5) In most applications power must be removed and the fault condition cleared in order to reset a PPTC device; however under certain unusual conditions, a PPTC device may automatically reset. PPTC devices should not be used in an application where an automatic reset could create a safety hazard, such as garbage disposals and blenders. Appropriate qualification testing should be performed. 6) It is the responsibility of the user to determine the need for back up or failsafe protection to prevent damage that may occur in the event of abnormal function or failure of the PPTC device. 7) Operation in circuits with a large inductance can generate a circuit voltage (Ldi/dt) above the rated voltage of a PPTC device.This product should not be used in an application where the maximum interrupt voltage or maximum interrupt current can be exceeded by inductive spikes. 8) Devices are not recommended for reflow soldering. 9) Device performance can be impacted negatively if devices are handled in a manner inconsistent with recommended electronic, thermal, or mechanical procedures for electronic components. 10) PPTC devices are not recommended for installation in applications where the device is constrained such that its PTC properties are inhibited, for example in rigid potting materials or in rigid housings, which lack adequate clearance to accommodate device expansion. 11) Contamination of the PPTC material with certain silicone-based oils or some aggressive solvents can adversely impact the performance of the devices. Figure L2-L5 Dimension Figures for LVR Devices Figure L2 Figure L3 E A B B D D C C CL to CL CL to CL 10 Figure L4 Figure L5 E A A B C CL to CL RoHS Compliant, ELV Compliant E B D 142 E A D C CL to CL A Part Number Min. B Max. Min. 6.9 — C Max. D Min. Max. 4.3 5.8 E Min. Max. Min. 7.6 — — Max. Figure LVR/LVRL LVR005NK — (0.27) LVR005NS — LVR008NK — LVR008NS — LVR012K — LVR012S — LVR016K — LVR016S — LVR025K — LVR025S — LVR033K — LVR033S — LVR040K — LVR040S — LVR055K — LVR055S — LVR075S — LVR100S — LVR125S — LVR200S — LVRL075S — LVRL100S — 6.9 — (0.27) 7.2 — 14.0 — LVRL200S — 16.3 — (0.93) RoHS Compliant, ELV Compliant 21.7 (0.85) — (0.64) 23.5 20.1 (0.79) (0.55) LVRL135S 17.0 (0.67) — (0.45) LVRL125S 33.8 (1.33) — (0.43) 11.5 27.4 (1.08) — (0.98) 10.9 24.4 (0.96) — (0.84) 24.9 23.4 (0.92) — (0.74) 21.2 21.7 (0.85) — (0.45) 18.7 22.4 (0.88) — (0.55) 11.5 19.5 (0.77) — (0.55) 14.0 20.9 (0.82) — (0.46) 14.0 16.5 (0.65) — (0.46) 11.5 19.0 (0.75) — (0.45) 11.5 17.4 (0.69) — (0.45) 11.4 18.8 (0.74) — (0.38) 11.4 12.5 (0.50) — (0.38) 9.6 13.8 (0.54) — (0.39) 9.6 10.7 (0.43) — (0.39) 9.9 12.9 (0.51) — (0.33) 9.9 10.2 (0.40) — (0.33) 8.3 12.4 (0.49) — (0.28) 8.3 9.9 (0.39) — (0.28) 7.2 12.1 (0.48) 21.7 (0.85) — 31.8 (1.25) (0.17) (0.23) 4.3 5.8 (0.17) (0.23) 4.3 5.8 (0.17) (0.23) 4.3 5.8 (0.17) (0.23) 4.3 5.8 (0.17) (0.23) 4.3 5.8 (0.17) (0.23) 4.3 5.8 (0.17) (0.23) 4.3 5.8 (0.17) (0.23) 4.3 5.8 (0.17) (0.23) 4.3 5.8 (0.17) (0.23) 4.3 5.8 (0.17) (0.23) 4.3 5.8 (0.17) (0.23) 4.3 5.8 (0.17) (0.23) 4.3 5.8 (0.17) (0.23) 4.3 5.8 (0.17) (0.23) 4.3 5.8 (0.17) (0.23) 4.1 6.1 (0.16) (0.24) 8.9 11.4 (0.35) (0.45) 8.9 11.4 (0.35) (0.45) 8.9 11.4 (0.35) (0.45) 4.3 5.8 (0.17) (0.23) 4.3 5.8 (0.17) (0.23) 4.3 5.8 (0.17) (0.23) 4.3 5.8 (0.17) (0.23) 9.4 10.9 (0.37) (0.43) (0.30) 7.6 — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — (0.30) 7.6 7.6 7.6 7.6 7.6 7.6 7.6 7.6 7.6 7.6 7.6 7.6 7.6 5.1 5.1 5.1 5.1 7.6 7.6 7.6 — — 7.6 — — — (0.30) 7.6 (0.30) 10 L5 4.1 (0.16) — L5 4.1 (0.16) (0.30) L5 4.1 (0.16) (0.30) L4 6.1 (0.24) (0.30) L4 5.3 (0.21) (0.20) L5 5.1 (0.20) (0.20) L5 4.8 (0.19) (0.20) L3 4.1 (0.16) (0.20) L5 4.1 (0.16) (0.30) L3 3.8 (0.15) (0.30) L5 3.8 (0.15) (0.30) L3 3.8 (0.15) (0.30) L5 3.8 (0.15) (0.30) L3 3.8 (0.15) (0.30) L4 3.8 (0.15) (0.30) L2 3.8 (0.15) (0.30) L4 3.8 (0.15) (0.30) L2 3.8 (0.15) (0.30) L4 3.8 (0.15) (0.30) L2 4.6 (0.18) (0.30) L4 4.6 (0.18) (0.30) L2 4.6 (0.18) (0.30) 7.6 4.6 (0.18) PolySwitch Resettable Devices – Line-Voltage-Rated Devices Table L4 Dimensions for LVR Devices in Millimeters (Inches) L5 4.1 (0.16) L5 4.1 (0.16) L5 143 Figure L6 Typical Time-to-trip curves at 20°C for LVR Devices Figure L6 K L M N O P Q = = = = = = = LVRL100 LVR100 LVRL125 LVR125 LVRL135 LVRL200 LVR200 1000 L 100 E B Time-to-trip (s) LVR/LVRL A = LVR005N B = LVR008N C = LVR012 D = LVR016 E = LVR025 F = LVR033 G = LVR040 H = LVR055 I = LVRL075 J = LVR075 A C Q MN J O F G H D I P K 10 N H 1 G A D B C J I L MO K Q P F E 0.1 0.1 1 10 Fault Current (A) Table L5 Physical Characteristics and Environmental Specifications for LVR Devices LVR/LVRL Physical Characteristics Lead material LVR005N-016 : Tin-plated copper, (24AWG), ø0.51mm (0.020in.) LVR025-040 : Tin-plated copper, (22AWG), ø0.64mm (0.025in.) LVR055-200 : Tin-plated copper, (20AWG), ø0.81mm (0.032in.) LVRL : Tin-plated copper, (20AWG), ø0.81mm (0.032in.) Solderability per ANSI/J-STD-002 Category 3 Per IEC-STD 68-2-20, Test Tb, Method 1A, Condition B, can withstand 10 seconds at 260°C ±5°C LVR005N-055 : Cured, flame-retardant epoxy polymer, meets UL 94V-0 LVR075-200 : Cured, flame-retardant modified silicone, meets UL 94V-0 LVRL : Cured, flame-retardant epoxy polymer, meets UL 94V-0 Soldering characteristics Solder heat withstand Insulating material Note: Devices are not designed to be placed through a reflow process. Environmental Specifications 10 Test Passive aging Conditions 70°C, 1000 hours 85°C, 1000 hours 85°C, 85%RH, 1000 hours 85°C, -40°C (10 times) MIL-STD-202, Method 215F Humidity aging Thermal shock Solvent resistance Resistance Change ±10% ±10% ±20% ±15% No change Agency Recognitions for LVR Devices UL CSA TÜV 144 File # E74889 File # CA78165 Certificate number available on request (per IEC 60730-1). RoHS Compliant, ELV Compliant 100 Part Number Bag Quantity Tape & Reel Quantity Ammo Pack Quantity Standard Package Quantity Part Marking Agency Recognition LVR/LVRL LVR005NK 500 — — 10,000 L005 UL,CSA, TÜV — 1,500 — 7,500 L005 UL,CSA, TÜV 500 — — 10,000 L005 UL,CSA, TÜV — 1,500 — 7,500 L005 UL,CSA, TÜV 500 — — 10,000 L008 UL,CSA, TÜV — 1,500 — 7,500 L008 UL,CSA, TÜV 500 — — 10,000 L008 UL,CSA, TÜV — 1,500 — 7,500 L008 UL,CSA, TÜV 500 — — 10,000 L012 UL,CSA, TÜV — 2,000 — 10,000 L012 UL,CSA, TÜV 500 — — 10,000 L012 UL,CSA, TÜV — 2,000 — 10,000 L012 UL,CSA, TÜV 500 — — 10,000 L016 UL,CSA, TÜV — 2,000 — 10,000 L016 UL,CSA, TÜV 500 — — 10,000 L016 UL,CSA, TÜV — 2,000 — 10,000 L016 UL,CSA, TÜV 500 — — 10,000 L025 UL,CSA, TÜV — 2,000 — 10,000 L025 UL,CSA, TÜV 500 — — 10,000 L025 UL,CSA, TÜV — 2,000 — 10,000 L025 UL,CSA, TÜV 500 — — 10,000 L033 UL,CSA, TÜV — 2,000 — 10,000 L033 UL,CSA, TÜV 500 — — 10,000 L033 UL,CSA, TÜV — 2,000 — 10,000 L033 UL,CSA, TÜV 500 — — 10,000 L040 UL,CSA, TÜV — 2,000 — 10,000 L040 UL,CSA, TÜV 500 — — 10,000 L040 UL,CSA, TÜV — 2,000 — 10,000 L040 UL,CSA, TÜV LVR055K 500 — — 10,000 L055 UL,CSA, TÜV LVR055S 500 — — 10,000 L055 UL,CSA, TÜV — 1,000 — 5,000 L055 UL,CSA, TÜV LVR075S 500 — — 10,000 L075 UL,CSA, TÜV LVR100S 250 — — 5,000 L100 UL,CSA, TÜV LVR125S 250 — — 5,000 L125 UL,CSA, TÜV LVR200S 250 — — 5,000 L200 UL,CSA, TÜV LVRL075S 500 — — 10,000 L075 UL,CSA, TÜV LVRL100S 500 — — 10,000 L100 UL,CSA, TÜV LVRL125S 500 — — 10,000 L125 UL,CSA, TÜV LVRL135S 500 — — 10,000 L135 UL,CSA, TÜV LVRL200S 250 — — 5,000 L200 UL,CSA, TÜV LVR005NK-2 LVR005NS LVR005NS-2 LVR008NK LVR008NK-2 LVR008NS LVR008NS-2 LVR012K LVR012K-2 LVR012S LVR012S-2 LVR016K LVR016K-2 LVR016S LVR016S-2 LVR025K LVR025K-2 LVR025S LVR025S-2 LVR033K LVR033K-2 LVR033S LVR033S-2 LVR040K LVR040K-2 LVR040S LVR040S-2 LVR055S-2 RoHS Compliant, ELV Compliant PolySwitch Resettable Devices – Line-Voltage-Rated Devices Table L6 Packaging and Marking Information for LVR Devices 10 145 Table L7 Tape and Reel Specifications for LVR Devices LVR devices are available in tape and reel packaging per EIA468-B/IEC60286-2 standards. See Figures L7 and L8 for details. Description EIA Mark Dimension (mm) Carrier tape width W 18 -0.5/+1.0 Hold-down tape width W4 11 Minimum Top distance between tape edges W6 3 Maximum Sprocket hole position W5 9 -0.5/+0.75 Sprocket hole diameter D0 4 ± 0.2 Abscissa to plane (straight lead) (LVR005N to LVR016) H 18.5 ± 2.5 Abscissa to plane (kinked lead) (LVR005N to LVR016) H0 16.0 ± 0.5 Abscissa to top (LVR005N to LVR016) H1 32.2 Maximum Abscissa to top* (LVR025 to LVR055) H1 45.0 Maximum Overall width with lead protrusion (LVR005N to LVR016) C1 43.2 Maximum Overall width with lead protrusion (LVR025 to LVR055) C1 56.0 Maximum Overall width without lead protrusion (LVR005N to LVR016) C2 42.5 Maximum Overall width without lead protrusion (LVR025 to LVR055) C2 56.0 Maximum Lead protrusion L1 1.0 Maximum Maximum Protrusion of cut-out L 11.0 Protrusion beyond hold-down tape I2 Not specified — Sprocket hole pitch P0 12.7 ± 0.3 Device pitch (LVR005N to LVR040) — 12.7 ± 0.3 Device pitch (LVR055) — 25.4 ± 0.6 Pitch tolerance — 20 consecutive ±1 Tape thickness t 0.9 Maximum Overall tape and lead thickness (LVR005N to LVR040) t1 1.5 Maximum Overall tape and lead thickness (LVR055) t1 2.3 Maximum Splice sprocket hole alignment — 0 ± 0.3 Body lateral deviation ⌬h 0 ± 1.0 Body tape plane deviation ⌬p 0 ± 1.3 Ordinate to adjacent component lead P1 3.81 ± 0.7 Lead spacing* F 5.08 +0.75/-0.5 Reel width (LVR005N to LVR040) w2 56.0 Maximum Reel width* (LVR055) w2 63.5 Maximum a 370.0 Maximum Space between flanges* (LVR005N to LVR040) w1 48.0 Maximum Space between flanges* (LVR055) w1 55.0 Maximum Arbor hold diameter c 26.0 ± 12.0 Core diameter* n 91.0 Maximum Box — 64/372/362 Maximum Consecutive missing places — None — Empty places per reel — 0.1% Maximum Reel diameter 10 146 Tolerance *Differs from EIA specification. RoHS Compliant, ELV Compliant Dh Dp Dh Dp Reference plane H1 P1 H1 F A L H0 B W4 C2 C1 H W5 W I2 L1 P0 D0 Direction of unreeling Cross section A-B t Figure L8 EIA Referenced Reel Dimensions for LVR Devices Reel Upper side n Type a Direction of unreeling Lower side c w1 PolySwitch Resettable Devices – Line-Voltage-Rated Devices Figure L7 EIA Referenced Taped Component Dimensions for LVR Devices Cross section w2 Optional shape: Circular or polygonal Part Numbering System for LVR Devices LVR 075 S 2 Packaging Blank = Packaged in bags -1 = 25.4mm (1.0 inch) minimum lead length -2 = Tape and reel -X.X = Special lead cut length (inch) 10 Modifier K = Standard kinked lead S = Straight lead Hold Current Indicator Product Series LVR = 240V rated LVRL = 120V rated RoHS Compliant, ELV Compliant 147 10 148