ASM-SENSOR 3291

CLAMP ON HiTESTER 3291
CLAMP ON LEAK HiTESTER 3293
Clamp Testers
The World's First Flip Clamp!
For leak and load current: 3293 (0.06mA to 1000A) Double the
functionality
For load current: 3291 (0.06A to 1000A)
✔ Stylish pocket-size design
✔ Backlit display with automatic reverse feature
✔ Filter
3291
Load current
10uA
Resolution
3293
Leak and load current
2
Flip-type clamp on design delivers the ease-of-use demanded by field technicians
Flip-down display keeps readings in easy view whether the target wire is up high or down low
Equipped with an innovative display that flips down for easy visibility, the 3291 and 3293 are designed for efficient
measurement of indoor wiring in a variety of environments, from factories, buildings, and offices to residences.
Easy to read means easy to use
■ Easy measurement of wires on ceilings
❏ D isplay rot ates f reely through 18 0 ° to keep
measurements in view.
Flip angle: 180°
■ Easy to see, even when held up high
❏ Measurement reading reverses automatically when
the display is flipped open to ensure readability.
❏ Backlight lets you read measurements in dim
locations
• Push and hold for 2 seconds to activate
• Backlight goes out automatically after 15 seconds
Display can also be reversed manually
with the press of a button.
■ Easy to see, even when held down low
New clamp design is easier to attach
Slim clamp with a wide aperture attaches easily, requiring only
12.5 mm of space between wires.
Unmatched ease of use
Open Jaws to Power On
❏ Clamp meter turns on automatically when the clamp is opened so you
can begin taking measurement immediately.
Automatically turns off 1 minute after input falls to 0A following
measurement. (Can be manually disabled.)
❏ Slim core opens wide for easier clamping.
3291
3293
11mm
8mm
Up to 30 mm in diameter
Up to 24 mm in diameter
Sometimes it’s easier to clamp the
target wire at an angle.
3
Extensive current measurement functions
True RMS lets you measure even distorted currents accurately
Use with 3-phase 4-wire 440V lines
True RMS ensures accurate measurement,
even of distorted load and leak currents
3291: CAT III 600 V (CAT IV 300 V)
3293: CAT III 300 V
❏ Why does the same current yield different readings?
Averaging-type clamp on
current meter
Inverters, office equipment, AC adapters most load current waveforms are distorted.
Current meters that display average True RMS clamp on
rectified RMS values does not allow you to current meter
obtain accurate RMS measurements.
Filter out noise
The 3291 and 3293 incorporate a switchable high-frequency
noise filter. When activated, this filter rejects frequencies of
180 Hz and above to enable measurement approximating the
filter characteristics of an earth leakage circuit breaker (ELCB).
Measure leak and load current with the 3293
The 3293 features 6 ranges from 30 mA to 1000A,
offering ±5% rdg ±5 dgt measurement accuracy of 1mA
leak currents.
❏ Easy-to-use auto range feature
3293
Leak current easurement
Range
30.00mA 300.0mA
3291
Leak current easurement
Load current measurement
6.000A
60.00A
1000A
Load current measurement
60.00A
Range
600.0A
600.0A
1000A
❏ Get the maximum value of fluctuating current readings
3293
Actual Size
Push and hold for 2
seconds to activate filter
Filter on
Measure fluctuating currents with the peak hold feature
The 3291 and 3293’s peak hold feature (with bar graph hold) lets you
capture peak values for currents that fluctuate due to load variability.
❏ Easy measurement of the peak value of a fluctuating current.
*Holds the peak value for data updated approximately 2 times/second.
Current (A)
Peak value display
Time
Peak value is held on the bar graph.
Loop a wrist strap through the small opening to
help keep the instrument from being dropped
4
Pocket Size Clamp On Design
■ 3291, 3293 Specifications (accuracy at 23˚C±5˚C (73˚F±9˚F), 80% RH or less)
3291
Fits perfectly into a shirt pocket.
Measurable
conductor size
Rectification
Max. rated voltage to earth
Measurement Range
•Auto Range switching
••Zero-suppress at 5 counts
❏ Compact design for superior
portability
3291
Actual Size
Accuracy
filter ON: fc=180Hz
Guaranteeed Accuracy Period
Accuracy Guaranteed
Measurements
Crest factor
Response Time
Display Refresh Rate
Temperature Coefficient
Effect of
Conductor Position
Effect of External
Magnetic Field
Other Functions
Usage Environment
Storage Environment
Standards
Rated Voltage and
maximum rated power
Power Supply and
max. continuous use
Included soft case protects the
instrument and attaches
conveniently to your belt.
Leak and load
ø30mm (1.18")max.
ø24mm (0.94")max.
True RMS
AC600Vrms
AC300Vrms
30mA/300mA/
60A/600A/1000A
6A/60A/600A/1000A
±1.5%rdg. ±5dgt. (50Hz to 60Hz),
±5%rdg. ±5dgt. (1mA to 2.70mA)
filter OFF: ±2.0%rdg. ±5dgt. (45 to 66Hz),
±3.0%rdg. ±5dgt. (66 to 400Hz)
(Add±1%rdg. for when using 60A on the 3293)
1 Year (or opening and closing of the sensor 10,000 times)
Minimum 1.00mA
Minimum 5.40A
(Add±1%rdg. for readings of 0.270 to 0.540A )
2.8 max (1.6 max when current exceeds 600A)
Max. 1.5s
(Refers to time required to achieve 90% of accuracy specifications)
Approx. 2 times/second (Bar graph: Approx. 4 times/second)
Add (0.05 x accuracy specifications)/°C (at 0°C to 40°C)
within ±0.1% (at or below 6A range)
within ±5.0%
within ±5.0% (at or below 60A range)
Max 7.5mA (within a 400A/m
not defined
magnetic field, at or below 6A range)
Display hold, maximum value hold (hold bar graph position),
reversible LCD display, backlight, auto power off, auto power
on when jaws are open, battery level indication
0°C to 40°C/32°F to 104°F, 80%rh max. (no condensation)
-10°C to 50°C/14°F to 122°F, 80%rh max. (no condensation)
EN61010-2-032
EN61010-2-032
Type A current sensor,
Type A current sensor,
CAT III 600V, CAT IV 300V, EN61326
CAT III 300V, EN61326
Dimensions and mass
Convenient portable case
3293
Load
DC3V, 25mVA
Button type lithium battery (CR2032) x 1,
Approx. 10 hours (continuous, no load)
50W×136H×26Dmm, 90g
50W×130H×26Dmm, 120g
1.97"× 5.35" H × 1.02" D, 3.2 oz.
1.97"× 5.12" × 1.02", 4.2 oz.
❏ Soft case protects the instrument inside toolboxes.
Carrying Case Model 9757
(included)
Inside toolboxes
Attaches to belt
0
5
10
5
15
20
10
6.00
6.00mA
0
Bundled Accessories: Carrying Case 9757 x 1, Wrist strap x 1, Button type lithium battery (CR2032 - test use only) x 1, Instruction Manual x 1,
Basic Operation Sticker x 1
HIOKI (Shanghai) Sales & Trading Co., Ltd. :
1904 Shanghai Times Square Office, 93 Huai Hai Zhong Road
Shanghai, P.R.China POSTCODE: 200021
TEL +86-21-6391-0090/0092 FAX +86-21-6391-0360
E-mail: [email protected]
HEAD OFFICE :
81 Koizumi, Ueda, Nagano, 386-1192, Japan
TEL +81-268-28-0562 / FAX +81-268-28-0568
E-mail: [email protected]
Beijing Office :
A-2602 Freetown, 58 Dong San Huan Nan Road
Beijing, P.R.China POSTCODE: 100022
TEL +86-10-5867-4080/4081 FAX +86-10-5867-4090
E-mail: [email protected]
Guangzhou Office :
Room 303, Profit Plaza, No.76, West Huangpu Road
Guangzhou, P.R.China POSTCODE: 510623
TEL +86-20-38392673/2676 FAX +86-20-38392679
E-mail: [email protected]
0
5
10
15
15
20
20
6.00mA
10
All information correct as of Jul. 12, 2007. All specifications are subject to change without notice.
0
5
6.00mA
HIOKI USA CORPORATION :
6 Corporate Drive, Cranbury, NJ 08512 USA
TEL +1-609-409-9109 / FAX +1-609-409-9108
E-mail: [email protected]