CLAMP ON HiTESTER 3291-50, 3293-50

CLAMP ON HiTESTER 3291-50
CLAMP ON LEAK HiTESTER 3293-50
Clamp Testers
The World's First Flip Clamp!
K!
K!
LOO
Slim clamp sensor
fits in narrow spaces
True-rms measurement
provides great accuracy
●
LOO
Easy-to-read
measurements
Adjustable display angle!
K!
LOO
LED backlight
provides clear viewing
in dim locations
●
●
●
Powers on when
you open the clamp
Bright white LEDs!
●
3291-50 : Load current
3293-50 : Leak current
3291-50
Convenient
pocket-size design
3293-50
2
Flip-type clamp on design delivers the ease-of-use demanded by field technicians
Innovative Concept
?
"Flip" clamp
● Easy visibility even when clamping in high and low places ?
Have you
Measurement values you can hold for later reading ?
ever wanted... ●
● A clamp sensor that won’t break easily when twisted ?
K!
y!
spla ments
i
D
Flip
asure
ead
y-to-r
Eas
LOO
me
Displayed values automatically
invert when flipped open!
Yo u c a n a l s o
push a button to
manually invert the
display.
Equipped with an innovative display that flips down for easy visibility, the 329150 and 3293-50 are designed for efficient measurement of indoor wiring in a
variety of environments, from factories, buildings, and offices to residences.
■ Easy to see, even on high or low locations
■ Easy measurement of wires on ceilings
New Design
Slim Sensor
?
● The ability to clamp even in crowded wiring locations ?
Have you
ever wanted... ● To have thinner clamp sensors ?
K! Model 3291-50 can clamp on
LOO
wires spaced only 12.5 mm apart.
Thin sensors let you clamp easily, even around closely spaced wires.
3291-50
3293-50
11mm
8mm
Up to 30 mm in diameter
Sometimes it’s easier to clamp the
target wire at an angle.
Up to 24 mm in diameter
3
Extensive current measurement functions
1
“True RMS” lets you measure even distorted currents accurately
With “True RMS” measurement, the 3291-50 and 3293-50 accurately measure even
distorted load and leakage currents.
Two ways to convert alternating current to RMS are “true RMS response” and “average rectified RMS response” (averaging).
Both display the same value for a sine wave, but can display very different values for distorted waveforms.
Averaging
True RMS response
(the 3291-50 and 3293-50 work this way)
High-frequency waveform components are
included in the calculated RMS display value.
When measuring current waveforms
distorted by inverters…
The measured waveform is treated as a single-frequency
(undistorted) sine wave, and the calculated average of
the ac signal is converted to an RMS display value.
Measurement error increases with waveform distortion.
As inverters and switching power supplies proliferate, the need for the capability to
measure distorted current waveforms grows.
A true RMS clamp-on current meter is the proper tool for accurate measurements.
2
Measure leak and load current with the 3293-50
The 3293-50 provides 6 ranges, from 30 mA to 1000 A.
The 3291-50 provides 3 ranges, from 60 A to 1000 A.
Range 30.00mA 300.0mA
3291-50
6.000A
60.00A
Provides a high-frequency noise filter.
When activated, the filter rejects frequencies above 180 Hz, approximating the filter
characteristic of an earth leakage circuit breaker (ELCB) for measurements.
Cuts high-harmonic components to measure the fundamental waveform
(The filter in the 3293-50 is enabled by default.)
Auto range
3293-50
3
Filter out noise
600.0A
1000A
600.0A
1000A
Auto range
60.00A
Range
Filter on
4
Includes a Peak Hold function
Captures the peak value of fluctuating currents.
Retains the maximum value during data updating
Current (A)
Peak value display
Time
5
Safety Design
3291-50 : CAT III 600 V (CAT IV 300 V)
3293-50 : CAT III 300 V
4
3291-50, 3293-50 Specifications
(accuracy at 23˚C±5˚C (73˚F±9˚F), 80% RH or less)
3291-50
3293-50
ø30mm (1.18")max.
ø24mm (0.94")max.
(Load)
Measurable
conductor size
Rectification
(Leak)
Guaranteeed Accuracy Period
Accuracy Guaranteed
Measurements
Crest factor
Response Time
Display update Rate
Temperature Coefficient
Effect of
Conductor Position
Effect of External
Magnetic Field
Other Functions
Usage Environment
Storage Environment
Safety
EMC
Rated Voltage and
maximum rated power
Power Supply
Fits perfectly into a shirt pocket.
Compact design for superior portability
True RMS
Max. rated voltage 600Vrms, Measurement category III
300Vrms, Measurement
to earth
300Vrms, Measurement category IV
category III
Measurement Range
30mA/300mA
60A/600A/1000A
(Auto Range switching)
6A/60A/600A/1000A
filter ON : ±1.5%rdg. ±5dgt. (50Hz to 60Hz)
Accuracy
filter OFF : ±1.5%rdg. ±5dgt. (45Hz to 66Hz)
filter ON : fc=180Hz
Standards
Pocket Size Clamp On Design
±3.0%rdg. ±5dgt. (66Hz to 400Hz)
1 Year (or opening and closing of the sensor 10,000 times)
2A to 1000A
3293-50
Actual Size
1mA to 1000A
2.8 or less (up to 600A), 1.68 or less (1000A range)
1.1sec. or less
1.1sec. or less
Add (0.05 × accuracy specifications)/°C (except 23°C ±5°C)
within ±0.1% (up to 6A range)
within ±5.0%
within ±5.0% (greater than 60A range)
Max 7.5mA (within a 400A/m
--magnetic field, at or below 6A range)
Display hold, maximum value hold, reversible LCD display,
backlight, auto power off, battery level indication
0°C to 40°C/32°F to 104°F, 80%rh or less. (no condensation)
-10°C to 50°C/14°F to 122°F, 80%rh or less. (no condensation)
EN61010 Type A current sensor
EN61326
●
DC3V, 25mVA
Button type lithium battery (CR2032) × 1
Approx. 20 hours
Approx. 18 hours
50W×136H×26Dmm, 115g
50W×130H×26Dmm, 135g
Dimensions and mass
1.97"× 5.35" H × 1.02" D, 4.1 oz. 1.97"× 5.12" H × 1.02" D, 4.8 oz.
Battery lifetime
Loop a wrist strap through the small
opening to help keep the instrument from
being dropped
Bundled Accessories: Carrying Case 9757 × 1, Wrist strap × 1, Button type lithium battery (CR2032 - test use only) × 1,
Instruction Manual × 1
■ Carrying Case 9757
■ Wrist strap
Wrap around your hand or
neck to avoid dropping
1608-1610 Shanghai Times Square Office, 93 Huai Hai Zhong
Road, Shanghai, P.R.China POSTCODE: 200021
TEL +86-21-6391-0090/0092 FAX +86-21-6391-0360
E-mail: [email protected]
HIOKI USA CORPORATION :
6 Corporate Drive, Cranbury, NJ 08512 USA
TEL +1-609-409-9109 / FAX +1-609-409-9108
E-mail: [email protected]
Attaches to belt
Protects the instrument
Attaches conveniently to
your belt
HIOKI (Shanghai) Sales & Trading Co., Ltd. :
HEAD OFFICE :
81 Koizumi, Ueda, Nagano, 386-1192, Japan
TEL +81-268-28-0562 / FAX +81-268-28-0568
E-mail: [email protected]
Inside toolboxes
DISTRIBUTED BY
Beijing Office :
A-2602 Freetown, 58 Dong San Huan Nan Road
Beijing, P.R.China POSTCODE: 100022
TEL +86-10-5867-4080/4081 FAX +86-10-5867-4090
E-mail: [email protected]
Guangzhou Office :
Room A-3206, Victory PlazaServices Center, No.103,
Tiyuxi Road, Guangzhou, P.R.China POSTCODE:510620
TEL +86-20-38392673/2676 FAX +86-20-38392679
E-mail: [email protected]
All information correct as of Sep. 28, 2009. All specifications are subject to change without notice.
3291-50E1-99E
Printed in Japan