12 kV Kilovac H-14 Make & Break Load Switching Kilovac H-16 Make & Break Load Switching Features: Double pole, double throw contacts Vacuum dielectric for power switching low current loads 30 Amps DC continuous current rating Corona shield high voltage terminals available Meets requirements of MIL-R-83725 Features: 12 kV rating; isolates 5 kV at 32 MHz Vacuum dielectric for power switching low current loads Double pole, double throw contacts Widely used as a transmit/receive switch Meets requirements of MIL-R-83725 Part Number PRODUCT SPECIFICATIONS H-14 Units COIL DATA H-16 Nominal, Volts dc 12 26.5 Pickup, Volts dc, Maximum 8 16 80 .5 - 5 1 - 10 5 - 50 24 120 2000 Contact Arrangement .......................................................... DPDT DPDT Contact Form ........................................................................ 2C 2C 15 15 Test Voltage (dc or 60Hz) ................................................... kV Peak Rated Operating Voltage ..................................................... kV Peak 12 12 2.5 MHz ........................................................................... 10 10 16 MHz ............................................................................ 8 8 32 MHz ............................................................................ 5 5 dc or 60 Hz ..................................................................... 30 30 2.5 MHz ........................................................................... 15 10 16 MHz ............................................................................ 10 6 32 MHz ............................................................................ 8 4 500 500 Amps Coil Hi-Pot (V RMS, 60 Hz) ........................................... Contact Capacitance ............................................................ O NIT PART NUMBER SELECPART NUMBER SELECPART NUMBER SELECTION Sample Part No. Model 14 16 Coil Voltage Blank = 26.5 Vdc /12Vdc = 12 Vdc /115Vdc = 115 Vdc H 14 /12Vdc pF Between Open Contacts ................................................. 1 1 Open Contacts to Ground .............................................. 2.5 2.5 Contact Resistance, Maximum ........................................... ohms 0.015 0.03 Operate Time, Maximum ..................................................... ms 20 20 Release Time, Maximum ..................................................... ms 20 20 Shock, 11 ms 1/2 Sine ........................................................ Peak G's 20 20 Vibration, 10 Gs Peak ......................................................... Hz 55-500 55-500 Operating Ambient Temperature Range ............................ Coil Resistance (Ohms ±10%) Ratings listed are for 25°C, sea level conditions dc or 60 Hz ..................................................................... Continuous Carry Current , Maximum Drop-Out, Volts dc 115 C -55 to +125 -55 to +125 Mechanical Life (Operations x 106) .................................... Cycles 1 0.5 Weight, Nominal .................................................................. oz. 8 6 o CII Technologies / P.O. Box 4422 / Santa Barbara, CA 93140 / ph 805.684.4560 / fax 805.684.9679 / e-mail [email protected] / website www.ciitech.com 44