15 kV Kilovac H-26 Features: Make & Break Load Switching Highly reliable four pole double throw relay Used to switch multiple loads and for polarity reversal Vacuum dielectric for power switching low current loads Meets requirements of MIL-R-83725 Features: Part Number PRODUCT SPECIFICATIONS Units COIL DATA H-26 Nominal, Volts dc 12 26.5 Contact Arrangement .......................................................... 4PDT Pickup, Volts dc, Maximum 8 16 80 Contact Form ........................................................................ 4C Drop-Out, Volts dc .5 - 5 1 - 10 5 - 50 17 Coil Resistance (Ohms ±10%) N.A. 130 2100 Test Voltage (dc or 60Hz) ................................................... kV Peak Rated Operating Voltage ..................................................... kV Peak Ratings listed are for 25°C, sea level conditions dc or 60 Hz ..................................................................... 15 2.5 MHz ........................................................................... 12 16 MHz ............................................................................ 10 32 MHz ............................................................................ 7 Continuous Carry Current , Maximum ............................... Amps dc or 60 Hz ..................................................................... 30 2.5 MHz ........................................................................... 10 16 MHz ............................................................................ 6 32 MHz ............................................................................ 4 Coil Hi-Pot (V RMS, 60 Hz) ........................................... Contact Capacitance ............................................................ PART NUMBER SELECTION Sample Part No. Model H-26 Coil Voltage Blank = 26.5 Vdc /12Vdc = 12 Vdc /115Vdc = 115 Vdc H-26 /12Vdc COIL DATA 500 pF Between Open Contacts ................................................. 1 Open Contacts to Ground .............................................. 2.5 Contact Resistance, Maximum ........................................... ohms 0.02 Operate Time, Maximum ..................................................... ms 30 Release Time, Maximum ..................................................... ms 30 Shock, 11 ms 1/2 Sine ........................................................ Peak G's 30 Vibration, 10 Gs Peak ......................................................... Hz 55-500 Operating Ambient Temperature Range ............................ 115 C -55 to +125 Mechanical Life (Operations x 106) .................................... Cycles 0.1 Weight, Nominal .................................................................. oz. 12 o CII Technologies / P.O. Box 4422 / Santa Barbara, CA 93140 / ph 805.684.4560 / fax 805.684.9679 / e-mail [email protected] / website www.ciitech.com 48