MA-COM H-26

15 kV Kilovac H-26
Features:
Make & Break Load Switching
• Highly reliable four pole double throw relay
• Used to switch multiple loads and for polarity
reversal
• Vacuum dielectric for power switching low
current loads
• Meets requirements of MIL-R-83725
Features:
Part Number
PRODUCT SPECIFICATIONS
Units
COIL DATA
H-26
Nominal, Volts dc
12
26.5
Contact Arrangement ..........................................................
4PDT
Pickup, Volts dc, Maximum
8
16
80
Contact Form ........................................................................
4C
Drop-Out, Volts dc
.5 - 5
1 - 10
5 - 50
17
Coil Resistance (Ohms ±10%)
N.A.
130
2100
Test Voltage (dc or 60Hz) ...................................................
kV Peak
Rated Operating Voltage .....................................................
kV Peak
Ratings listed are for 25°C, sea level conditions
dc or 60 Hz .....................................................................
15
2.5 MHz ...........................................................................
12
16 MHz ............................................................................
10
32 MHz ............................................................................
7
Continuous Carry Current , Maximum ...............................
Amps
dc or 60 Hz .....................................................................
30
2.5 MHz ...........................................................................
10
16 MHz ............................................................................
6
32 MHz ............................................................................
4
Coil Hi-Pot (V RMS, 60 Hz) ...........................................
Contact Capacitance ............................................................
PART NUMBER SELECTION
Sample Part No.
Model
H-26
Coil Voltage
Blank = 26.5 Vdc
/12Vdc = 12 Vdc
/115Vdc = 115 Vdc
H-26
/12Vdc
COIL DATA
500
pF
Between Open Contacts .................................................
1
Open Contacts to Ground ..............................................
2.5
Contact Resistance, Maximum ...........................................
ohms
0.02
Operate Time, Maximum .....................................................
ms
30
Release Time, Maximum .....................................................
ms
30
Shock, 11 ms 1/2 Sine ........................................................
Peak G's
30
Vibration, 10 G’s Peak .........................................................
Hz
55-500
Operating Ambient Temperature Range ............................
115
C
-55 to +125
Mechanical Life (Operations x 106) ....................................
Cycles
0.1
Weight, Nominal ..................................................................
oz.
12
o
CII Technologies / P.O. Box 4422 / Santa Barbara, CA 93140 / ph 805.684.4560 / fax 805.684.9679 / e-mail [email protected] / website www.ciitech.com
48