47 Watts
Total Power:
Input Voltage:
# of Outputs:
47 Watts
85 - 264 VAC
120 - 300VDC
Triple
Electrical Specifications
Special Features
•
•
•
•
•
•
•
Totally enclosed
Universal input
Quick Installation
Built-in EMI filter
Low output ripple
Overvoltage protection
Overload protection
Input
Input range
85 - 264 VAC (wide range)
120 - 300VDC
Frequency
47-63 Hz
Inrush current
<20A peak @ 115VAC, <40A peak @ 230VAC cold start @ 25°C
Input current
1A max. (RMS) @ 115VAC
Efficiency
70% typical at full load
EMI filter
FCC Class B conducted and radiated; CISPR 22 Class B
conducted and radiated; EN55022 Class B conducted and
radiated
Bellcore GR-1089-core Class B conducted
Safety ground leadage
current
<3.5 mA @ 50/60 Hz, 264 VAC input
Output
Maximum power
47W with 12CFM forced air
Cross regulation
±2% on output 1; ±5% on outputs 2, 3
Hold-up time
10ms @ 47W load, 100VAC input
Overload protection
Short circuit protection on all outputs. Case overload protected @ 110-135% above peak rating
Overvoltage protection 5.50-6.75 VDC on main output
Safety
VDE
UL
CSA
CB
CE
0805/EN60950
21310-3336-0003
UL60950
E186249
CSA 22.2-234 -950-95-M90
Certificate and report
6593
Mark (LVD)
Embedded Power for
Business-Critical Continuity
Rev. 8.17.06
LCT43-E Series
2 of 3
Environmental Specifications
Operating temperature: 0° to 50°C ambient derate each output as 2.5% per degree from 50° to
70°C
Storage temperature:
-40°C to +85°C
Temperature coefficient: ±.04% per °C
Electromagnetic
designed to meet IEC1000-4;
susceptibility:
-2, -3, -4, -5, -6, -8, -11 Level 3
Humidity:
Vibration:
MTBF demonstrated
Operating; non-condensing 5% to
90%
.41G from 3 to 500Hz; Spectral
break points of .0065 G2/Hz
at 10 Hz and 200 Hz and 5
db/octave roll off at each end,
2 hours per axis
>300,000 hours at full load and
25°C ambient conditions
Ordering Information
Model Output Minimu
Number Voltage m Load
LCT43-E
Maximum Load Maximum
with
Load with
Peak Regulati
Ripple
on2
P/P (PARD)3
Convection 12CFM Forced Load1
Cooling
Air
+5V
1.0A
4A
7A
8A
+4/-2%
50mV
+12V
-12V
0.1A
0A
1A
0.5A
1.2A
0.5A
1.5A
0.6A
±5%
±5%
120mV
120mV
1. Peak current lasting <30 seconds with a maximum 10% duty cycle.
2. At 25°C including initial tolerance, line voltage, load currents and output voltages adjusted to
factory settings.
3. Peak-to-peak with 20 MHz bandwidth and 10 μF (tantalum capacitor) in parallel with a 0.1 μF
capacitor at rated line voltage and load ranges.
Embedded Power for
Business-Critical Continuity
Rev. 8.17.06
LCT43-E Series
3 of 3
Mechanical Drawing
Astec Power
Mating Connectors
5810 Van Allen Way
Carlsbad, CA 92008
USA
Telephone: +1 760 930 4600
Facsimile: +1 760 930 0698
Technical Support: +1 888 41 ASTEC
or +1 407 241 2752
AC Input:
IEC 320
DC Outputs:
Molex 15-48-0406 (USA)
Notes:
1. Specifications subject to change without notice.
2. All dimensions in inches (mm), tolerance is ±0.02" (±0.5mm)
3.
4.
5.
Specifications are for convection rating at factory settings at 115VAC
input 25ºC unless otherwise stated
Warranty: 1 year
Weight: 1.25lbs/0.57kg
Pin Assignments
Connector
LCT43-E
SK1-1
SK1-2
SK1-3
AC Line
Ground
AC Neutral
SK2-1
SK2- 2
SK2- 3
-12V
Com
+5V
SK2-4
+5V
SK2-5
SK2-6
Common
+12V
Waterfront Business Park
Merry Hill, Dudley
West Midlands, DY5 1LX
United Kingdom
Telephone: +44 (0) 1384 842 211
Facsimile: +44 (0) 1384 843 355
Units 2111-2116, Level 21
Tower 1, Metroplaza
223, Hing Fong Road
Kwai Fong, New Territories
Hong Kong
Telephone: +852 2437 9662
Facsimile: +852 2402 4426
For global contact, visit:
www.astecpower.com
[email protected]
While every precaution has been taken to ensure
accuracy and completeness in this literature, Astec
Power assumes no responsibility, and disclaims
all liability for damages resulting from use of this
information or for any errors or omissions.
Printed in U S A
Emerson Network Power.
The global leader in enabling
business-critical continuity.
AC Power
Connectivity
DC Power
Embedded Power
Inbound Power
Integrated Cabinet Solutions
Outside Plant
Precision Cooling
Site Monitoring and Services
EmersonNetworkPower. com
Emerson Network Power and the Emerson
Network Power logo are trademarks and
service marks of Emerson Electric Co.
©2006 Emerson Electric Co.