TI TLC2543C

TLC2543C, TLC2543I, TLC2543M
12-BIT ANALOG-TO-DIGITAL CONVERTERS
WITH SERIAL CONTROL AND 11 ANALOG INPUTS
SLAS079F – DECEMBER 1993 – REVISED NOVEMBER 2001
D
D
D
D
D
DB, DW, J, OR N PACKAGE
(TOP VIEW)
AIN0
AIN1
AIN2
AIN3
AIN4
AIN5
AIN6
AIN7
AIN8
GND
1
20
2
19
3
18
4
17
5
16
6
15
7
14
8
13
9
12
10
11
VCC
EOC
I/O CLOCK
DATA INPUT
DATA OUT
CS
REF +
REF –
AIN10
AIN9
FN PACKAGE
(TOP VIEW)
AIN2
AIN1
AIN0
VCC
EOC
D
D
D
D
D
D
D
12-Bit-Resolution A/D Converter
10-µs Conversion Time Over Operating
Temperature
11 Analog Input Channels
3 Built-In Self-Test Modes
Inherent Sample-and-Hold Function
Linearity Error . . . ± 1 LSB Max
On-Chip System Clock
End-of-Conversion Output
Unipolar or Bipolar Output Operation
(Signed Binary With Respect to 1/2 the
Applied Voltage Reference)
Programmable MSB or LSB First
Programmable Power Down
Programmable Output Data Length
CMOS Technology
Application Report Available†
description
The TLC2543C and TLC2543I are 12-bit, switchedcapacitor, successive-approximation, analog-todigital converters. Each device, with three control
inputs [chip select (CS), the input-output clock, and
the address input (DATA INPUT)], is designed for
communication with the serial port of a host processor
or peripheral through a serial 3-state output. The
device allows high-speed data transfers from the
host.
AIN3
AIN4
AIN5
AIN6
AIN7
4
3 2 1 20 19
18
5
17
6
16
7
15
8
14
9 10 11 12 13
I/O CLOCK
DATA INPUT
DATA OUT
CS
REF +
AIN8
GND
AIN9
AIN10
REF –
D
D
In addition to the high-speed converter and versatile control capability, the device has an on-chip 14-channel
multiplexer that can select any one of 11 inputs or any one of three internal self-test voltages. The
sample-and-hold function is automatic. At the end of conversion, the end-of-conversion (EOC) output goes high
to indicate that conversion is complete. The converter incorporated in the device features differential
high-impedance reference inputs that facilitate ratiometric conversion, scaling, and isolation of analog circuitry
from logic and supply noise. A switched-capacitor design allows low-error conversion over the full operating
temperature range.
The TLC2543C is characterized for operation from TA = 0°C to 70°C. The TLC2543I is characterized for
operation from TA = – 40°C to 85°C. The TLC2543M is characterized for operation from TA = – 55°C to 125°C.
Please be aware that an important notice concerning availability, standard warranty, and use in critical applications of
Texas Instruments semiconductor products and disclaimers thereto appears at the end of this data sheet.
† Microcontroller Based Data Acquisition Using the TLC2543 12-bit Serial-Out ADC (SLAA012)
Copyright  2001, Texas Instruments Incorporated
PRODUCTION DATA information is current as of publication date.
Products conform to specifications per the terms of Texas Instruments
standard warranty. Production processing does not necessarily include
testing of all parameters.
On products compliant to MIL-PRF-38535, all parameters are tested
unless otherwise noted. On all other products, production
processing does not necessarily include testing of all parameters.
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
1
TLC2543C, TLC2543I, TLC2543M
12-BIT ANALOG-TO-DIGITAL CONVERTERS
WITH SERIAL CONTROL AND 11 ANALOG INPUTS
SLAS079F – DECEMBER 1993 – REVISED NOVEMBER 2001
AVAILABLE OPTIONS
PACKAGE
SMALL OUTLINE
TA
(DB)†
(DW)†
PLASTIC CHIP
CARRIER
CERAMIC DIP
PLASTIC DIP
(FN)†
(J)
(N)
0°C to 70°C
TLC2543CDB
TLC2543CDW
TLC2543CFN
—
TLC2543CN
– 40°C to 85°C
TLC2543IDB
TLC2543IDW
TLC2543IFN
—
TLC2543IN
– 55°C to 125°C
—
—
—
TLC2543MJ
—
† Available in tape and reel and ordered as the TLC2543CDBLE, TLC2543IDBR, TLC2543CDWR, TLC2543IDWR, TLC2543CFNR, or
TLC2543IFNR.
functional block diagram
AIN0
AIN1
AIN2
AIN3
AIN4
AIN5
AIN6
AIN7
AIN8
AIN9
AIN10
1
2
3
4
5
6
7
8
9
11
12
Sample-andHold
Function
14-Channel
Analog
Multiplexer
REF +
REF –
14
13
12-Bit
Analog-to-Digital
Converter
(Switched Capacitors)
12
4
Input Address
Register
Output
Data
Register
12
12-to-1 Data
Selector and
Driver
16
DATA
OUT
4
3
Control Logic
and I/O
Counters
Self-Test
Reference
19
DATA
INPUT
I/O CLOCK
CS
2
17
18
15
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
EOC
TLC2543C, TLC2543I, TLC2543M
12-BIT ANALOG-TO-DIGITAL CONVERTERS
WITH SERIAL CONTROL AND 11 ANALOG INPUTS
SLAS079F – DECEMBER 1993 – REVISED NOVEMBER 2001
Terminal Functions
TERMINAL
I/O
DESCRIPTION
1 – 9,
11, 12
I
Analog input. These 11 analog-signal inputs are internally multiplexed. The driving source impedance should
be less than or equal to 50 Ω for 4.1-MHz I/O CLOCK operation and be capable of slewing the analog input
voltage into a capacitance of 60 pF.
CS
15
I
Chip select. A high-to-low transition on CS resets the internal counters and controls and enables DATA OUT,
DATA INPUT, and I/O CLOCK. A low-to-high transition disables DATA INPUT and I/O CLOCK within a setup
time.
DATA INPUT
17
I
Serial-data input. A 4-bit serial address selects the desired analog input or test voltage to be converted next.
The serial data is presented with the MSB first and is shifted in on the first four rising edges of I/O CLOCK.
After the four address bits are read into the address register, I/O CLOCK clocks the remaining bits in order.
DATA OUT
16
O
The 3-state serial output for the A/D conversion result. DATA OUT is in the high-impedance state when CS
is high and active when CS is low. With a valid CS, DATA OUT is removed from the high-impedance state
and is driven to the logic level corresponding to the MSB/LSB† value of the previous conversion result. The
next falling edge of I/O CLOCK drives DATA OUT to the logic level corresponding to the next MSB / LSB, and
the remaining bits are shifted out in order.
EOC
19
O
End of conversion. EOC goes from a high to a low logic level after the falling edge of the last I/O CLOCK and
remains low until the conversion is complete and the data is ready for transfer.
GND
10
I/O CLOCK
18
I
Input /output clock. I/O CLOCK receives the serial input and performs the following four functions:
1. It clocks the eight input data bits into the input data register on the first eight rising edges of I/O CLOCK
with the multiplexer address available after the fourth rising edge.
2. On the fourth falling edge of I/O CLOCK, the analog input voltage on the selected multiplexer input
begins charging the capacitor array and continues to do so until the last falling edge of the I/O
CLOCK.
3. It shifts the 11 remaining bits of the previous conversion data out on DATA OUT. Data changes on
the falling edge of I/O CLOCK.
4. It transfers control of the conversion to the internal state controller on the falling edge of the last
I/O CLOCK.
REF +
14
I
Positive reference voltage The upper reference voltage value (nominally VCC) is applied to REF+. The
maximum input voltage range is determined by the difference between the voltage applied to this terminal and
the voltage applied to the REF – terminal.
REF –
13
I
Negative reference voltage. The lower reference voltage value (nominally ground) is applied to REF –.
NAME
NO.
AIN0 – AIN10
Ground. GND is the ground return terminal for the internal circuitry. Unless otherwise noted, all voltage
measurements are with respect to GND.
VCC
20
Positive supply voltage
† MSB/LSB = Most significant bit / least significant bit
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
3
TLC2543C, TLC2543I, TLC2543M
12-BIT ANALOG-TO-DIGITAL CONVERTERS
WITH SERIAL CONTROL AND 11 ANALOG INPUTS
SLAS079F – DECEMBER 1993 – REVISED NOVEMBER 2001
absolute maximum ratings over operating free-air temperature range (unless otherwise
noted)†
Supply voltage range, VCC (see Note 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . – 0.5 V to 6.5 V
Input voltage range, VI (any input) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . – 0.3 V to VCC + 0.3 V
Output voltage range, VO . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . – 0.3 V to VCC + 0.3 V
Positive reference voltage, Vref + . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . VCC + 0.1 V
Negative reference voltage, Vref – . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . – 0.1 V
Peak input current, II (any input) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ± 20 mA
Peak total input current, II (all inputs) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ± 30 mA
Operating free-air temperature range, TA: TLC2543C . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0°C to 70°C
TLC2543I . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . – 40°C to 85°C
TLC2543M . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . – 55°C to 125°C
Storage temperature range, Tstg . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . – 65°C to 150°C
Lead temperature 1,6 mm (1/16 inch) from the case for 10 seconds . . . . . . . . . . . . . . . . . . . . . . . . . . . . 260°C
† Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and
functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
NOTE 1: All voltage values are with respect to the GND terminal with REF – and GND wired together (unless otherwise noted).
recommended operating conditions
Supply voltage, VCC
MIN
NOM
MAX
4.5
5
5.5
Positive reference voltage, Vref + (see Note 2)
VCC
0
Negative reference voltage, Vref – (see Note 2)
Differential reference voltage, Vref + – Vref – (see Note 2)
2.5
Analog input voltage (see Note 2)
0
High-level control input voltage, VIH
VCC = 4.5 V to 5.5 V
VCC = 4.5 V to 5.5 V
Low-level control input voltage, VIL
Clock frequency at I/O CLOCK
Hold time, address bits after I/O CLOCK↑, th(A) (see Figure 4)
Hold time, CS low after last I/O CLOCK↓, th(CS) (see Figure 5)
V
V
V
VCC + 0.1
VCC
2
0
Setup time, address bits at DATA INPUT before I/O CLOCK↑, tsu(A) (see Figure 4)
VCC
UNIT
V
V
V
0.8
V
4.1
MHz
100
ns
0
ns
0
ns
1.425
µs
Pulse duration, I/O CLOCK high, twH(I/O)
120
ns
Pulse duration, I/O CLOCK low, twL(I/O)
120
Setup time, CS low before clocking in first address bit, tsu(CS) (see Note 3 and Figure 5)
Transition time, I/O CLOCK high to low, tt(I/O) (see Note 4 and Figure 6)
Transition time, DATA INPUT and CS, tt(CS)
TLC2543C
Operating free-air temperature, TA
0
ns
1
µs
10
µs
70
TLC2543I
– 40
85
TLC2543M
– 55
125
°C
NOTES: 2. Analog input voltages greater than that applied to REF+ convert as all ones (111111111111), while input voltages less than that applied
to REF– convert as all zeros (000000000000).
3. To minimize errors caused by noise at the CS input, the internal circuitry waits for a setup time after CS↓ before responding to control
input signals. No attempt should be made to clock in an address until the minimum CS setup time has elapsed.
4. This is the time required for the clock input signal to fall from VIHmin to VILmax or to rise from VILmax to VIHmin. In the vicinity of
normal room temperature, the devices function with input clock transition time as slow as 1 µs for remote data acquisition applications
where the sensor and the A/D converter are placed several feet away from the controlling microprocessor.
4
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
TLC2543C, TLC2543I, TLC2543M
12-BIT ANALOG-TO-DIGITAL CONVERTERS
WITH SERIAL CONTROL AND 11 ANALOG INPUTS
SLAS079F – DECEMBER 1993 – REVISED NOVEMBER 2001
electrical characteristics over recommended operating free-air temperature range,
VCC = Vref+ = 4.5 V to 5.5 V, f(I/O CLOCK) = 4.1 MHz (unless otherwise noted)
PARAMETER
TEST CONDITIONS
TLC2543C, TLC2543I
MIN
TYP†
MAX
VOH
High level output voltage
High-level
VCC = 4.5 V,
VCC = 4.5 V to 5.5 V,
IOH = –1.6 mA
IOH = –20 µA
VOL
Low level output voltage
Low-level
VCC = 4.5 V,
VCC = 4.5 V to 5.5 V,
IOL = 1.6 mA
IOL = 20 µA
IOZ
High-impedance
g
off-state output
current
VO = VCC,
VO = 0,
CS at VCC
1
2.5
CS at VCC
1
– 2.5
IIH
IIL
High-level input current
1
2.5
Low-level input current
VI = VCC
VI = 0
1
– 2.5
µA
ICC
Operating supply current
CS at 0 V
1
2.5
mA
ICC(PD)
Power-down current
For all digital inputs,
0 ≤ VI ≤ 0.5 V or VI ≥ VCC – 0.5 V
4
25
µA
Selected channel leakage
current
Maximum static analog
reference current into REF +
Ci
Input
capacitance
Selected channel at VCC,
2.4
UNIT
V
VCC – 0.1
0.4
0.1
Unselected channel at 0 V
µA
µA
1
Selected channel at 0 V,
Unselected channel at VCC
Vref + = VCC,
V
–1
Vref – = GND
1
2.5
Analog inputs
30
60
Control inputs
5
15
µA
µA
pF
† All typical values are at VCC = 5 V, TA = 25°C.
electrical characteristics over recommended operating free-air temperature range,
VCC = Vref+ = 4.5 V to 5.5 V, f(I/O CLOCK) = 4.1 MHz (unless otherwise noted)
PARAMETER
TEST CONDITIONS
MIN
TLC2543M
TYP†
MAX
VOH
High level output voltage
High-level
VCC = 4.5 V,
VCC = 4.5 V to 5.5 V,
IOH = –1.6 mA
IOH = –20 µA
VOL
Low level output voltage
Low-level
VCC = 4.5 V,
VCC = 4.5 V to 5.5 V,
IOL = 1.6 mA
IOL = 20 µA
IOZ
High-impedance
g
off-state output
current
VO = VCC,
VO = 0,
CS at VCC
1
2.5
CS at VCC
1
– 2.5
IIH
IIL
High-level input current
VI = VCC
VI = 0
1
10
µA
Low-level input current
1
– 10
µA
ICC
Operating supply current
CS at 0 V
1
2.5
mA
Power-down current
For all digital inputs,
0 ≤ VI ≤ 0.5 V or VI ≥ VCC – 0.5 V
4
25
µA
ICC(PD)
Selected channel leakage
current
Maximum static analog
reference current into REF +
Ci
Input
capacitance
Selected channel at VCC,
2.4
UNIT
V
VCC – 0.1
0.4
0.1
Unselected channel at 0 V
– 10
Vref – = GND
µA
10
Selected channel at 0 V,
Unselected channel at VCC
Vref + = VCC,
V
1
2.5
Analog inputs
30
60
Control inputs
5
15
µA
µA
pF
† All typical values are at VCC = 5 V, TA = 25°C.
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
5
TLC2543C, TLC2543I, TLC2543M
12-BIT ANALOG-TO-DIGITAL CONVERTERS
WITH SERIAL CONTROL AND 11 ANALOG INPUTS
SLAS079F – DECEMBER 1993 – REVISED NOVEMBER 2001
operating characteristics over recommended operating free-air temperature range,
VCC = Vref+ = 4.5 V to 5.5 V, f(I/O CLOCK) = 4.1 MHz
PARAMETER
TEST CONDITIONS
MIN
TYP†
MAX
UNIT
Linearity error (see Note 5)
See Figure 2
±1
LSB
Differential linearity error
See Figure 2
±1
LSB
EO
Offset error (see Note 6)
See Note 2 and
Figure 2
± 1.5
LSB
EG
Gain error (see Note 6)
See Note 2 and
Figure 2
±1
LSB
ET
Total unadjusted error (see Note 7)
± 1.75
LSB
EL
ED
Self-test output code (see Table 3 and Note 8)
t(conv)
Conversion time
DATA INPUT = 1011
2048
DATA INPUT = 1100
0
DATA INPUT = 1101
4095
See Figures 9 – 14
8
10
10 + total
I/O CLOCK
periods +
td(I/O-EOC)
µs
tc
Total cycle time (access, sample, and conversion)
See Figures 9 – 14
and Note 9
tacq
Channel acquisition time (sample)
See Figures 9 – 14
and Note 9
tv
td(I/O-DATA)
Valid time, DATA OUT remains valid after I/O CLOCK↓
See Figure 6
Delay time, I/O CLOCK↓ to DATA OUT valid
See Figure 6
td(I/O-EOC)
td(EOC-DATA)
Delay time, last I/O CLOCK↓ to EOC↓
See Figure 7
Delay time, EOC↑ to DATA OUT (MSB / LSB)
See Figure 8
100
ns
tPZH, tPZL
tPHZ, tPLZ
Enable time, CS↓ to DATA OUT (MSB / LSB driven)
See Figure 3
0.7
1.3
µs
Disable time, CS↑ to DATA OUT (high impedance)
See Figure 3
70
150
ns
tr(EOC)
tf(EOC)
Rise time, EOC
See Figure 8
15
50
ns
Fall time, EOC
See Figure 7
15
50
ns
tr(bus)
tf(bus)
Rise time, data bus
See Figure 6
15
50
ns
Fall time, data bus
See Figure 6
15
50
ns
5
µs
td(I/O-CS)
Delay time, last I/O CLOCK↓ to CS↓ to abort conversion
(see Note 10)
4
12
10
µs
I/O
CLOCK
periods
ns
1.5
150
ns
2.2
µs
† All typical values are at TA = 25°C.
NOTES: 2. Analog input voltages greater than that applied to REF + convert as all ones (111111111111), while input voltages less than that
applied to REF – convert as all zeros (000000000000).
5. Linearity error is the maximum deviation from the best straight line through the A/D transfer characteristics.
6. Gain error is the difference between the actual midstep value and the nominal midstep value in the transfer diagram at the specified
gain point after the offset error has been adjusted to zero. Offset error is the difference between the actual midstep value and the
nominal midstep value at the offset point.
7. Total unadjusted error comprises linearity, zero-scale, and full-scale errors.
8. Both the input address and the output codes are expressed in positive logic.
9. I/O CLOCK period = 1 /(I/O CLOCK frequency) (see Figure 7).
10. Any transitions of CS are recognized as valid only when the level is maintained for a setup time. CS must be taken low at ≤ 5 µs
of the tenth I/O CLOCK falling edge to ensure a conversion is aborted. Between 5 µs and 10 µs, the result is uncertain as to whether
the conversion is aborted or the conversion results are valid.
6
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
TLC2543C, TLC2543I, TLC2543M
12-BIT ANALOG-TO-DIGITAL CONVERTERS
WITH SERIAL CONTROL AND 11 ANALOG INPUTS
SLAS079F – DECEMBER 1993 – REVISED NOVEMBER 2001
PARAMETER MEASUREMENT INFORMATION
15 V
50 Ω
C1
10 µF
C2
0.1 µF
C3
470 pF
10 Ω
_
U1
+
VI
C1
10 µF
TLC2543
AIN0 – AIN10
C3
470 pF
C2
0.1 µF
50 Ω
– 15 V
LOCATION
DESCRIPTION
U1
C1
C2
C3
OP27
10-µF 35-V tantalum capacitor
0.1-µF ceramic NPO SMD capacitor
470-pF porcelain Hi-Q SMD capacitor
PART NUMBER
—
—
AVX 12105C104KA105 or equivalent
Johanson 201S420471JG4L or equivalent
Figure 1. Analog Input Buffer to Analog Inputs AIN0 – AIN10
VCC
Test Point
VCC
Test Point
RL = 2.18 kΩ
RL = 2.18 kΩ
EOC
DATA OUT
CL = 50 pF
12 kΩ
12 kΩ
CL = 100 pF
Figure 2. Load Circuits
Data
Valid
2V
CS
tPZH, tPZL
DATA
OUT
2V
0.8 V
DATA INPUT
0.8 V
tPHZ, tPLZ
2.4 V
90%
0.4 V
10%
Figure 3. DATA OUT to Hi-Z Voltage Waveforms
POST OFFICE BOX 655303
th(A)
tsu(A)
I/O CLOCK
0.8 V
Figure 4. DATA INPUT and I/O CLOCK
Voltage Waveforms
• DALLAS, TEXAS 75265
7
TLC2543C, TLC2543I, TLC2543M
12-BIT ANALOG-TO-DIGITAL CONVERTERS
WITH SERIAL CONTROL AND 11 ANALOG INPUTS
SLAS079F – DECEMBER 1993 – REVISED NOVEMBER 2001
PARAMETER MEASUREMENT INFORMATION
2V
CS
0.8 V
tsu(CS)
I/O CLOCK
th(CS)
Last
Clock
0.8 V
0.8 V
NOTE A: To ensure full conversion accuracy, it is recommended that no input signal change
occurs while a conversion is ongoing.
Figure 5. CS and I/O CLOCK Voltage Waveforms
tt(I/O)
tt(I/O)
2V
2V
I/O CLOCK
0.8 V
0.8 V
0.8 V
I/O CLOCK Period
td(I/O-DATA)
tv
2.4 V
0.4 V
DATA OUT
2.4 V
0.4 V
tr(bus), tf(bus)
Figure 6. I/O CLOCK and DATA OUT Voltage Waveforms
I/O CLOCK
Last
Clock
0.8 V
td(I/O-EOC)
2.4 V
EOC
0.4 V
tf(EOC)
Figure 7. I/O CLOCK and EOC Voltage Waveforms
tr(EOC)
EOC
2.4 V
0.4 V
td(EOC-DATA)
2.4 V
0.4 V
DATA OUT
Valid MSB
Figure 8. EOC and DATA OUT Voltage Waveforms
8
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
TLC2543C, TLC2543I, TLC2543M
12-BIT ANALOG-TO-DIGITAL CONVERTERS
WITH SERIAL CONTROL AND 11 ANALOG INPUTS
SLAS079F – DECEMBER 1993 – REVISED NOVEMBER 2001
PARAMETER MEASUREMENT INFORMATION
CS
(see Note A)
I/O
CLOCK
1
2
3
4
5
6
Access Cycle B
8
11
12
Sample Cycle B
ÎÎÎÎÎÎÎ
ÎÎÎÎÎÎÎ
1
Hi-Z State
DATA
OUT
A11
A10
A9
A8
A7
A6
A5
A4
A1
A0
Previous Conversion Data
ÎÎÎÎÎÎÎÎ Î ÎÎÎÎÎÎÎÎ
ÎÎÎÎÎÎÎÎ Î ÎÎÎÎÎÎÎÎ
MSB
DATA
INPUT
7
B7
B6
B5
B4
MSB
B3
B2
B1
B11
ÎÎÎÎ
ÎÎÎÎ
LSB
C7
B0
LSB
EOC
t(conv)
Shift in New Multiplexer Address,
Simultaneously Shift Out Previous
Conversion Value
A/D Conversion
Interval
Initialize
Initialize
NOTE A: To minimize errors caused by noise at CS, the internal circuitry waits for a setup time after CS↓ before responding to control input signals.
Therefore, no attempt should be made to clock in an address until the minimum CS setup time has elapsed.
Figure 9. Timing for 12-Clock Transfer Using CS With MSB First
CS
(see Note A)
I/O
CLOCK
1
2
3
4
5
6
Access Cycle B
DATA
OUT
A11
A10
A9
8
11
A8
A7
A6
A5
A4
A1
ÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎ
ÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎ
ÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎ
B7
B6
MSB
B5
12
1
Sample Cycle B
Previous Conversion Data
MSB
DATA
INPUT
7
B4
B3
B2
B1
A0
B11
Low Level
ÎÎÎÎÎ
ÎÎÎÎÎ
ÎÎÎÎÎ
LSB
C7
B0
LSB
EOC
Shift in New Multiplexer Address,
Simultaneously Shift Out Previous
Conversion Value
Initialize
t(conv)
A/D Conversion
Interval
Initialize
NOTE A: To minimize errors caused by noise at CS, the internal circuitry waits for a setup time after CS↓ before responding to control input signals.
Therefore, no attempt should be made to clock in an address until the minimum CS setup time has elapsed.
Figure 10. Timing for 12-Clock Transfer Not Using CS With MSB First
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
9
TLC2543C, TLC2543I, TLC2543M
12-BIT ANALOG-TO-DIGITAL CONVERTERS
WITH SERIAL CONTROL AND 11 ANALOG INPUTS
SLAS079F – DECEMBER 1993 – REVISED NOVEMBER 2001
PARAMETER MEASUREMENT INFORMATION
CS
(see Note A)
1
I/O CLOCK
2
3
4
5
Access Cycle B
A7
DATA OUT
A6
A5
7
ÎÎÎÎÎÎ
ÎÎÎÎÎÎ
8
Sample Cycle B
A4
A3
A2
A1
Previous Conversion Data
Hi-Z
A0
1
B7
ÎÎÎÎÎÎÎÎ Î ÎÎÎÎÎÎÎÎÎÎ ÎÎÎÎÎ
ÎÎÎÎÎÎÎÎ Î ÎÎÎÎÎÎÎÎÎÎ ÎÎÎÎÎ
MSB
DATA INPUT
6
B7
B6
B5
B4
MSB
B3
LSB
B2
B1
B0
C7
LSB
EOC
Shift in New Multiplexer Address,
Simultaneously Shift Out Previous
Conversion Value
t(conv)
A/D Conversion
Interval
Initialize
Initialize
NOTE A: To minimize errors caused by noise at CS, the internal circuitry waits for a setup time after CS↓ before responding to control input signals.
Therefore, no attempt should be made to clock in an address until the minimum CS setup time has elapsed.
Figure 11. Timing for 8-Clock Transfer Using CS With MSB First
CS
(see Note A)
1
I/O CLOCK
2
3
4
5
Access Cycle B
DATA OUT
A7
A6
A5
7
8
1
Sample Cycle B
A4
A3
A2
A1
Previous Conversion Data
A0
Low Level
ÎÎÎÎÎÎ ÎÎÎÎÎÎÎÎÎÎÎ
ÎÎÎÎÎÎ ÎÎÎÎÎÎÎÎÎÎÎ
MSB
DATA INPUT
6
B7
MSB
B6
B5
B4
B3
ÎÎÎÎ
ÎÎÎÎ
LSB
B2
B1
B7
C7
B0
LSB
EOC
Shift in New Multiplexer Address,
Simultaneously Shift Out Previous
Conversion Value
Initialize
t(conv)
A/D Conversion
Interval
Initialize
NOTE A: To minimize errors caused by noise at CS, the internal circuitry waits for a setup time after CS↓ before responding to control input signals.
Therefore, no attempt should be made to clock in an address until the minimum CS setup time has elapsed.
Figure 12. Timing for 8-Clock Transfer Not Using CS With MSB First
10
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
TLC2543C, TLC2543I, TLC2543M
12-BIT ANALOG-TO-DIGITAL CONVERTERS
WITH SERIAL CONTROL AND 11 ANALOG INPUTS
SLAS079F – DECEMBER 1993 – REVISED NOVEMBER 2001
PARAMETER MEASUREMENT INFORMATION
CS
(see Note A)
I/O
CLOCK
1
2
3
4
5
6
Access Cycle B
7
8
15
16
Sample Cycle B
ÎÎÎÎÎÎÎ
ÎÎÎÎÎÎÎ
1
Hi-Z State
DATA
OUT
A15
A14
A13
A12
A11
A10
A9
A8
A1
A0
ÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎ
ÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎ
Previous Conversion Data
MSB
B15
ÎÎÎ
ÎÎ
LSB
DATA
INPUT
B7
B6
B5
B3
B4
MSB
B2
B1
B0
C7
LSB
EOC
t(conv)
Shift in New Multiplexer Address,
Simultaneously Shift Out Previous
Conversion Value
A/D Conversion
Interval
Initialize
Initialize
NOTE A: To minimize errors caused by noise at CS, the internal circuitry waits for a setup time after CS↓ before responding to control input signals.
Therefore, no attempt should be made to clock in an address until the minimum CS setup time has elapsed.
Figure 13. Timing for 16-Clock Transfer Using CS With MSB First
CS
(see Note A)
I/O
CLOCK
1
2
3
4
5
6
Access Cycle B
DATA
OUT
A15
A14
A13
7
8
15
1
Sample Cycle B
A12
A11
A10
A9
A8
A1
ÎÎ ÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎ
ÎÎ ÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎ
Previous Conversion Data
MSB
16
A0
Low Level
ÎÎÎÎÎ
ÎÎÎÎÎ
LSB
DATA
INPUT
B7
MSB
B6
B5
B4
B3
B2
B1
B15
B0
C7
LSB
EOC
Shift in New Multiplexer Address,
Simultaneously Shift Out Previous
Conversion Value
Initialize
t(conv)
A/D Conversion
Interval
NOTE A: To minimize errors caused by noise at CS, the internal circuitry waits for a setup time after CS↓ before responding to control input signals.
Therefore, no attempt should be made to clock in an address until the minimum CS setup time has elapsed.
Figure 14. Timing for 16-Clock Transfer Not Using CS With MSB First
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
11
TLC2543C, TLC2543I, TLC2543M
12-BIT ANALOG-TO-DIGITAL CONVERTERS
WITH SERIAL CONTROL AND 11 ANALOG INPUTS
SLAS079F – DECEMBER 1993 – REVISED NOVEMBER 2001
PRINCIPLES OF OPERATION
Initially, with chip select (CS) high, I/O CLOCK and DATA INPUT are disabled and DATA OUT is in the
high-impedance state. CS going low begins the conversion sequence by enabling I/O CLOCK and DATA INPUT
and removes DATA OUT from the high-impedance state.
The input data is an 8-bit data stream consisting of a 4-bit analog channel address (D7 – D4), a 2-bit data length
select (D3 – D2), an output MSB or LSB first bit (D1), and a unipolar or bipolar output select bit (D0) that are
applied to DATA INPUT. The I/O CLOCK sequence applied to the I/O CLOCK terminal transfers this data to the
input data register.
During this transfer, the I/O CLOCK sequence also shifts the previous conversion result from the output data
register to DATA OUT. I/O CLOCK receives the input sequence of 8, 12, or 16 clock cycles long depending on
the data-length selection in the input data register. Sampling of the analog input begins on the fourth falling edge
of the input I/O CLOCK sequence and is held after the last falling edge of the I/O CLOCK sequence. The last
falling edge of the I/O CLOCK sequence also takes EOC low and begins the conversion.
converter operation
The operation of the converter is organized as a succession of two distinct cycles: 1) the I/O cycle and 2) the
actual conversion cycle.
I/O cycle
The I/O cycle is defined by the externally provided I/O CLOCK and lasts 8, 12, or 16 clock periods, depending
on the selected output data length.
During the I/O cycle, the following two operations take place simultaneously.
An 8-bit data stream consisting of address and control information is provided to DATA INPUT. This data is
shifted into the device on the rising edge of the first eight I/O CLOCKs. DATA INPUT is ignored after the first
eight clocks during 12- or 16-clock I/O transfers.
The data output, with a length of 8, 12, or 16 bits, is provided serially on DATA OUT. When CS is held low, the
first output data bit occurs on the rising edge of EOC. When CS is negated between conversions, the first output
data bit occurs on the falling edge of CS. This data is the result of the previous conversion period, and after the
first output data bit, each succeeding bit is clocked out on the falling edge of each succeeding I/O CLOCK.
conversion cycle
The conversion cycle is transparent to the user, and it is controlled by an internal clock synchronized to
I/O CLOCK. During the conversion period, the device performs a successive-approximation conversion on the
analog input voltage. The EOC output goes low at the start of the conversion cycle and goes high when
conversion is complete and the output data register is latched. A conversion cycle is started only after the I/O
cycle is completed, which minimizes the influence of external digital noise on the accuracy of the conversion.
12
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
TLC2543C, TLC2543I, TLC2543M
12-BIT ANALOG-TO-DIGITAL CONVERTERS
WITH SERIAL CONTROL AND 11 ANALOG INPUTS
SLAS079F – DECEMBER 1993 – REVISED NOVEMBER 2001
PRINCIPLES OF OPERATION
power up and initialization
After power up, CS must be taken from high to low to begin an I/O cycle. EOC is initially high, and the input data
register is set to all zeroes. The contents of the output data register are random, and the first conversion result
should be ignored. To initialize during operation, CS is taken high and is then returned low to begin the next I/O
cycle. The first conversion after the device has returned from the power-down state may not read accurately
due to internal device settling.
Table 1. Operational Terminology
Current (N) I/O cycle
The entire I/O CLOCK sequence that transfers address and control data into the data register and clocks
the digital result from the previous conversion from DATA OUT
Current (N) conversion cycle
The conversion cycle starts immediately after the current I/O cycle. The end of the current I/O cycle is the
last clock falling edge in the I/O CLOCK sequence. The current conversion result is loaded into the output
register when conversion is complete.
Current (N) conversion result
The current conversion result is serially shifted out on the next I/O cycle.
Previous (N – 1) conversion cycle
The conversion cycle just prior to the current I/O cycle
Next (N + 1) I/O cycle
The I/O period that follows the current conversion cycle
Example: In the 12-bit mode, the result of the current conversion cycle is a 12-bit serial-data stream clocked out during
the next I/O cycle. The current I/O cycle must be exactly 12 bits long to maintain synchronization, even
when this corrupts the output data from the previous conversion. The current conversion is begun
immediately after the twelfth falling edge of the current I/O cycle.
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
13
TLC2543C, TLC2543I, TLC2543M
12-BIT ANALOG-TO-DIGITAL CONVERTERS
WITH SERIAL CONTROL AND 11 ANALOG INPUTS
SLAS079F – DECEMBER 1993 – REVISED NOVEMBER 2001
PRINCIPLES OF OPERATION
data input
The data input is internally connected to an 8-bit serial-input address and control register. The register defines
the operation of the converter and the output data length. The host provides the data word with the MSB first.
Each data bit is clocked in on the rising edge of the I/O CLOCK sequence (see Table 2 for the data input-register
format).
Table 2. Input-Register Format
INPUT DATA BYTE
ADDRESS BITS
FUNCTION SELECT
Select input channel
AIN0
AIN1
AIN2
AIN3
AIN4
AIN5
AIN6
AIN7
AIN8
AIN9
AIN10
Select test voltage
(Vref + – Vref –)/2
Vref –
Vref +
Software power down
D7
(MSB)
D6
D5
D4
0
0
0
0
0
0
0
0
1
1
1
0
0
0
0
1
1
1
1
0
0
0
0
0
1
1
0
0
1
1
0
0
1
0
1
0
1
0
1
0
1
0
1
0
1
1
1
0
1
1
1
0
0
1
0
1
1
1
1
0
Output data length
8 bits
12 bits
16 bits
Output data format
MSB first
LSB first (LSBF)
L1
L0
LSBF
BIP
D3
D2
D1
D0
(LSB)
0
X†
1
1
0
1
0
1
Unipolar (binary)
0
Bipolar (BIP) 2s complement
1
† X represents a do not care condition.
data input address bits
The four MSBs (D7 – D4) of the data register address one of the 11 input channels, a reference-test voltage,
or the power-down mode. The address bits affect the current conversion, which is the conversion that
immediately follows the current I/O cycle. The reference voltage is nominally equal to Vref+ – Vref –.
14
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
TLC2543C, TLC2543I, TLC2543M
12-BIT ANALOG-TO-DIGITAL CONVERTERS
WITH SERIAL CONTROL AND 11 ANALOG INPUTS
SLAS079F – DECEMBER 1993 – REVISED NOVEMBER 2001
PRINCIPLES OF OPERATION
data output length
The next two bits (D3 and D2) of the data register select the output data length. The data-length selection is
valid for the current I/O cycle (the cycle in which the data is read). The data-length selection, being valid for the
current I/O cycle, allows device start-up without losing I/O synchronization. A data length of 8, 12, or 16 bits can
be selected. Since the converter has 12-bit resolution, a data length of 12 bits is suggested.
With D3 and D2 set to 00 or 10, the device is in the 12-bit data-length mode and the result of the current
conversion is output as a 12-bit serial data stream during the next I/O cycle. The current I/O cycle must be exactly
12 bits long for proper synchronization, even when this means corrupting the output data from a previous
conversion. The current conversion is started immediately after the twelfth falling edge of the current I/O cycle.
With bits D3 and D2 set to 11, the 16-bit data-length mode is selected, which allows convenient communication
with 16-bit serial interfaces. In the 16-bit mode, the result of the current conversion is output as a 16-bit serial
data stream during the next I/O cycle with the four LSBs always reset to 0 (pad bits). The current I/O cycle must
be exactly 16 bits long to maintain synchronization even when this means corrupting the output data from the
previous conversion. The current conversion is started immediately after the sixteenth falling edge of the current
I/O cycle.
With bits D3 and D2 set to 01, the 8-bit data-length mode is selected, which allows fast communication with 8-bit
serial interfaces. In the 8-bit mode, the result of the current conversion is output as an 8-bit serial data stream
during the next I/O cycle. The current I/O cycle must be exactly eight bits long to maintain synchronization, even
when this means corrupting the output data from the previous conversion. The four LSBs of the conversion
result are truncated and discarded. The current conversion is started immediately after the eighth falling edge
of the current I/O cycle.
Since D3 and D2 take effect on the current I/O cycle when the data length is programmed, there can be a conflict
with the previous cycle when the data-word length is changed from one cycle to the next. This may occur when
the data format is selected to be least significant bit first, since at the time the data length change becomes
effective (six rising edges of I/O CLOCK), the previous conversion result has already started shifting out.
In actual operation, when different data lengths are required within an application and the data length is changed
between two conversions, no more than one conversion result can be corrupted and only when it is shifted out
in LSB-first format.
sampling period
During the sampling period, one of the analog inputs is internally connected to the capacitor array of the
converter to store the analog input signal. The converter starts sampling the selected input immediately after
the four address bits have been clocked into the input data register. Sampling starts on the fourth falling edge
of I/O CLOCK. The converter remains in the sampling mode until the eighth, twelfth, or sixteenth falling edge
of the I/O CLOCK depending on the data-length selection. After the EOC delay time from the last I/O CLOCK
falling edge, the EOC output goes low indicating that the sampling period is over and the conversion period has
begun. After EOC goes low, the analog input can be changed without affecting the conversion result. Since the
delay from the falling edge of the last I/O CLOCK to EOC low is fixed, time-varying analog input signals can be
digitized at a fixed rate without introducing systematic harmonic distortion or noise due to timing uncertainty.
After the 8-bit data stream has been clocked in, DATA INPUT should be held at a fixed digital level until EOC
goes high (indicating that the conversion is complete) to maximize the sampling accuracy and minimize the
influence of external digital noise.
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
15
TLC2543C, TLC2543I, TLC2543M
12-BIT ANALOG-TO-DIGITAL CONVERTERS
WITH SERIAL CONTROL AND 11 ANALOG INPUTS
SLAS079F – DECEMBER 1993 – REVISED NOVEMBER 2001
PRINCIPLES OF OPERATION
data register, LSB first
D1 in the input data register (LSB first) controls the direction of the output binary data transfer. When D1 is reset
to 0, the conversion result is shifted out MSB first. When set to 1, the data is shifted out LSB first. Selection of
MSB first or LSB first always affects the next I/O cycle and not the current I/O cycle. When changing from one
data direction to another, the current I/O cycle is never disrupted.
data register, bipolar format
D0 (BIP) in the input data register controls the binary data format used to represent the conversion result. When
D0 is cleared to 0, the conversion result is represented as unipolar (unsigned binary) data. Nominally, the
conversion result of an input voltage equal to Vref – is a code of all zeros (000 . . . 0), the conversion result of
an input voltage equal to Vref + is a code of all ones (111 . . . 1), and the conversion result of (Vref + + Vref – ) /2
is a code of a one followed by zeros (100 . . . 0).
When D0 is set to 1, the conversion result is represented as bipolar (signed binary) data. Nominally, conversion
of an input voltage equal to Vref – is a code of a one followed by zeros (100 . . . 0), conversion of an input voltage
equal to Vref + is a code of a zero followed by all ones (011 . . . 1), and the conversion of (Vref + + Vref –) /2 is a
code of all zeros (000 . . . 0). The MSB is interpreted as the sign bit. The bipolar data format is related to the
unipolar format in that the MSBs are always each other’s complement.
Selection of the unipolar or bipolar format always affects the current conversion cycle, and the result is output
during the next I/O cycle. When changing between unipolar and bipolar formats, the data output during the
current I/O cycle is not affected.
EOC output
The EOC signal indicates the beginning and the end of conversion. In the reset state, EOC is always high. During
the sampling period (beginning after the fourth falling edge of the I/O CLOCK sequence), EOC remains high
until the internal sampling switch of the converter is safely opened. The opening of the sampling switch occurs
after the eighth, twelfth, or sixteenth I/O CLOCK falling edge, depending on the data-length selection in the input
data register. After the EOC signal goes low, the analog input signal can be changed without affecting the
conversion result.
The EOC signal goes high again after the conversion is completed and the conversion result is latched into the
output data register. The rising edge of EOC returns the converter to a reset state and a new I/O cycle begins.
On the rising edge of EOC, the first bit of the current conversion result is on DATA OUT when CS is low. When
CS is negated between conversions, the first bit of the current conversion result occurs at DATA OUT on the
falling edge of CS.
data format and pad bits
D3 and D2 of the input data register determine the number of significant bits in the digital output that represent
the conversion result. The LSB-first bit determines the direction of the data transfer while the BIP bit determines
the arithmetic conversion. The numerical data is always justified toward the MSB in any output format.
The internal conversion result is always 12 bits long. When an 8-bit data transfer is selected, the four LSBs of
the internal result are discarded to provide a faster one-byte transfer. When a 12-bit transfer is used, all bits are
transferred. When a 16-bit transfer is used, four LSB pad bits are always appended to the internal conversion
result. In the LSB-first mode, four leading zeros are output. In the MSB-first mode, the last four bits output are
zeros.
16
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
TLC2543C, TLC2543I, TLC2543M
12-BIT ANALOG-TO-DIGITAL CONVERTERS
WITH SERIAL CONTROL AND 11 ANALOG INPUTS
SLAS079F – DECEMBER 1993 – REVISED NOVEMBER 2001
PRINCIPLES OF OPERATION
data format and pad bits (continued)
When CS is held low continuously, the first data bit of the newly completed conversion occurs on DATA OUT
on the rising edge of EOC. When a new conversion is started after the last falling edge of I/O CLOCK, EOC goes
low and the serial output is forced to a setting of 0 until EOC goes high again.
When CS is negated between conversions, the first data bit occurs on DATA OUT on the falling edge of CS.
On each subsequent falling edge of I/O CLOCK after the first data bit appears, the data is changed to the next
bit in the serial conversion result until the required number of bits has been output.
chip-select input (CS)
CS enables and disables the device. During normal operation, CS should be low. Although the use of CS is not
necessary to synchronize a data transfer, it can be brought high between conversions to coordinate the data
transfer of several devices sharing the same bus.
When CS is brought high, the serial-data output is immediately brought to the high-impedance state, releasing
its output data line to other devices that may share it. After an internally generated debounce time, I/O CLOCK
is inhibited, thus preventing any further change in the internal state.
When CS is subsequently brought low again, the device is reset. CS must be held low for an internal debounce
time before the reset operation takes effect. After CS is debounced low, I/O CLOCK must remain inactive (low)
for a minimum time before a new I/O cycle can start.
CS can interrupt any ongoing data transfer or any ongoing conversion. When CS is debounced low long enough
before the end of the current conversion cycle, the previous conversion result is saved in the internal output
buffer and shifted out during the next I/O cycle.
power-down features
When a binary address of 1110 is clocked into the input data register during the first four I/O CLOCK cycles,
the power-down mode is selected. Power down is activated on the falling edge of the fourth I/O CLOCK pulse.
During power down, all internal circuitry is put in a low-current standby mode. No conversions are performed,
and the internal output buffer keeps the previous conversion cycle data results provided that all digital inputs
are held above VCC – 0.5 V or below 0.5 V. The I/O logic remains active so the current I/O cycle must be
completed even when the power-down mode is selected. Upon power-on reset and before the first I/O cycle,
the converter normally begins in the power-down mode. The device remains in the power-down mode until a
valid input address (other than 1110) is clocked in. Upon completion of that I/O cycle, a normal conversion is
performed with the results being shifted out during the next I/O cycle.
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
17
TLC2543C, TLC2543I, TLC2543M
12-BIT ANALOG-TO-DIGITAL CONVERTERS
WITH SERIAL CONTROL AND 11 ANALOG INPUTS
SLAS079F – DECEMBER 1993 – REVISED NOVEMBER 2001
PRINCIPLES OF OPERATION
analog input, test, and power-down mode
The 11 analog inputs, three internal voltages, and power-down mode are selected by the input multiplexer
according to the input addresses shown in Tables 2, 3, and 4. The input multiplexer is a break-before-make type
to reduce input-to-input noise rejection resulting from channel switching. Sampling of the analog input starts on
the falling edge of the fourth I/O CLOCK and continues for the remaining I/O CLOCK pulses. The sample is held
on the falling edge of the last I/O CLOCK pulse. The three internal test inputs are applied to the multiplexer, then
sampled and converted in the same manner as the external analog inputs. The first conversion after the device
has returned from the power-down state may not read accurately due to internal device settling.
Table 3. Analog-Channel-Select Address
VALUE SHIFTED INTO
DATA INPUT
ANALOG INPUT
SELECTED
BINARY
HEX
AIN0
0000
0
AIN1
0001
1
AIN2
0010
2
AIN3
0011
3
AIN4
0100
4
AIN5
0101
5
AIN6
0110
6
AIN7
0111
7
AIN8
1000
8
AIN9
1001
9
AIN10
1010
A
Table 4. Test-Mode-Select Address
INTERNAL
SELF-TEST
VOLTAGE
SELECTED†
VALUE SHIFTED INTO
DATA INPUT
BINARY
HEX
1011
B
Vref + – Vref –
2
UNIPOLAR OUTPUT
RESULT (HEX)‡
800
Vref –
1100
C
000
Vref +
1101
D
FFF
† Vref + is the voltage applied to REF +, and Vref – is the voltage applied to REF –.
‡ The output results shown are the ideal values and may vary with the reference stability
and with internal offsets.
Table 5. Power-Down-Select Address
INPUT COMMAND
Power down
18
VALUE SHIFTED INTO
DATA INPUT
BINARY
HEX
1110
E
POST OFFICE BOX 655303
RESULT
ICC ≤ 25 µA
• DALLAS, TEXAS 75265
TLC2543C, TLC2543I, TLC2543M
12-BIT ANALOG-TO-DIGITAL CONVERTERS
WITH SERIAL CONTROL AND 11 ANALOG INPUTS
SLAS079F – DECEMBER 1993 – REVISED NOVEMBER 2001
PRINCIPLES OF OPERATION
converter and analog input
The CMOS threshold detector in the successive-approximation conversion system determines each bit by
examining the charge on a series of binary-weighted capacitors (see Figure 1). In the first phase of the
conversion process, the analog input is sampled by closing the SC switch and all ST switches simultaneously.
This action charges all the capacitors to the input voltage.
In the next phase of the conversion process, all ST and SC switches are opened and the threshold detector
begins identifying bits by identifying the charge (voltage) on each capacitor relative to the reference (REF –)
voltage. In the switching sequence, 12 capacitors are examined separately until all 12 bits are identified and
the charge-convert sequence is repeated. In the first step of the conversion phase, the threshold detector looks
at the first capacitor (weight = 4096). Node 4096 of this capacitor is switched to the REF+ voltage, and the
equivalent nodes of all the other capacitors on the ladder are switched to REF –. When the voltage at the
summing node is greater than the trip point of the threshold detector (approximately 1/2 VCC ), a bit 0 is placed
in the output register and the 4096-weight capacitor is switched to REF–. When the voltage at the summing node
is less than the trip point of the threshold detector, a bit 1 is placed in the register and this 4096-weight capacitor
remains connected to REF + through the remainder of the successive-approximation process. The process is
repeated for the 2048-weight capacitor, the 1024-weight capacitor, and so forth down the line until all bits are
determined. With each step of the successive-approximation process, the initial charge is redistributed among
the capacitors. The conversion process relies on charge redistribution to determine the bits from MSB to LSB.
reference voltage inputs
The two reference inputs used with the device are the voltages applied to the REF+ and REF– terminals. These
voltage values establish the upper and lower limits of the analog input to produce a full-scale and zero-scale
reading respectively. These voltages and the analog input should not exceed the positive supply or be lower
than ground consistent with the specified absolute maximum ratings. The digital output is at full scale when the
input signal is equal to or higher than REF+ terminal voltage and at zero when the input signal is equal to or lower
than REF– terminal voltage.
SC
Threshold
Detector
2048
4096
Node 4096
REF –
1024
REF+
REF+
REF –
ST
16
REF –
ST
8
REF+
REF –
ST
4
REF+
REF –
ST
REF+
REF –
ST
2
1
REF+
REF+
REF –
ST
REF –
ST
To Output
Latches
1
REF –
ST
ST
VI
Figure 15. Simplified Model of the Successive-Approximation System
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
19
TLC2543C, TLC2543I, TLC2543M
12-BIT ANALOG-TO-DIGITAL CONVERTERS
WITH SERIAL CONTROL AND 11 ANALOG INPUTS
SLAS079F – DECEMBER 1993 – REVISED NOVEMBER 2001
APPLICATION INFORMATION
4095
111111111111
VFS
See Notes A and B
4094
111111111110
VFSnom
4093
VFT = VFS – 1/2 LSB
2049
100000000001
2048
100000000000
VZT = VZS + 1/2 LSB
Step
Digital Output Code
111111111101
2047
011111111111
VZS
000000000001
1
000000000000
0
0.0012
0.0024
2.4564
2.4576
4.9128
2.4588
4.9134
2
0.0006
000000000010
4.9140
0
4.9152
VI – Analog Input Voltage – V
NOTES: A. This curve is based on the assumption that Vref+ and Vref – have been adjusted so that the voltage at the transition from digital 0
to 1 (VZT) is 0.0006 V and the transition to full scale (VFT) is 4.9134 V. 1 LSB = 1.2 mV.
B. The full-scale value (VFS) is the step whose nominal midstep value has the highest absolute value. The zero-scale value (VZS) is
the step whose nominal midstep value equals zero.
Figure 16. Ideal Conversion Characteristics
TLC2543
1
2
3
4
5
Analog
Inputs
6
7
8
9
11
12
15
AIN0
CS
AIN1
I/O CLOCK
AIN2
DATA INPUT
18
17
Processor
AIN3
AIN4
DATA OUT
AIN5
EOC
16
19
AIN6
AIN7
AIN8
REF+
AIN9
AIN10
REF–
14
5-V DC Regulated
13
GND
10
To Source
Ground
Figure 17. Serial Interface
20
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
Control
Circuit
TLC2543C, TLC2543I, TLC2543M
12-BIT ANALOG-TO-DIGITAL CONVERTERS
WITH SERIAL CONTROL AND 11 ANALOG INPUTS
SLAS079F – DECEMBER 1993 – REVISED NOVEMBER 2001
APPLICATION INFORMATION
simplified analog input analysis
Using the equivalent circuit in Figure 18, the time required to charge the analog input capacitance from 0 V to
VS within 1/2 LSB can be derived as follows:
ǒ
Ǔ
The capacitance charging voltage is given by
V
C
+ VS 1–e–tcńRtCi
Where:
(1)
Rt = Rs + ri
The final voltage to 1/2 LSB is given by
VC (1/2 LSB) = VS – (VS /8192)
(2)
ǒ
Ǔ
Equating equation 1 to equation 2 and solving for time tc gives
V
and
S
*
ǒ
V
Ǔ
ń8192 + VS 1–e–tcńRtCi
S
(3)
tc (1/2 LSB) = Rt × Ci × ln(8192)
(4)
Therefore, with the values given, the time for the analog input signal to settle is
tc (1/2 LSB) = (Rs + 1 kΩ) × 60 pF × ln(8192)
(5)
This time must be less than the converter sample time shown in the timing diagrams.
Driving Source†
TLC2543
Rs
VS
VI
ri
VC
1 kΩ Max
Ci
60 pF Max
VI = Input Voltage at AIN
VS = External Driving Source Voltage
Rs = Source Resistance
ri = Input Resistance
Ci = Input Capacitance
VC = Capacitance Charging Voltage
† Driving source requirements:
• Noise and distortion for the source must be equivalent to the
resolution of the converter.
• Rs must be real at the input frequency.
Figure 18. Equivalent Input Circuit Including the Driving Source
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
21
PACKAGE OPTION ADDENDUM
www.ti.com
24-Jan-2013
PACKAGING INFORMATION
Orderable Device
Status
(1)
Package Type Package Pins Package Qty
Drawing
Eco Plan
Lead/Ball Finish
(2)
MSL Peak Temp
Op Temp (°C)
Top-Side Markings
(3)
(4)
5962-9688601QRA
ACTIVE
CDIP
J
20
1
TBD
Call TI
Call TI
TLC2543CDB
ACTIVE
SSOP
DB
20
70
Green (RoHS
& no Sb/Br)
CU NIPDAU
Level-1-260C-UNLIM
P2543
TLC2543CDBG4
ACTIVE
SSOP
DB
20
70
Green (RoHS
& no Sb/Br)
CU NIPDAU
Level-1-260C-UNLIM
P2543
TLC2543CDBLE
OBSOLETE
SSOP
DB
20
TBD
Call TI
Call TI
TLC2543CDBR
ACTIVE
SSOP
DB
20
2000
Green (RoHS
& no Sb/Br)
CU NIPDAU
Level-1-260C-UNLIM
P2543
TLC2543CDBRG4
ACTIVE
SSOP
DB
20
2000
Green (RoHS
& no Sb/Br)
CU NIPDAU
Level-1-260C-UNLIM
P2543
TLC2543CDW
ACTIVE
SOIC
DW
20
25
Green (RoHS
& no Sb/Br)
CU NIPDAU
Level-1-260C-UNLIM
TLC2543C
TLC2543CDWG4
ACTIVE
SOIC
DW
20
25
Green (RoHS
& no Sb/Br)
CU NIPDAU
Level-1-260C-UNLIM
TLC2543C
TLC2543CDWR
ACTIVE
SOIC
DW
20
2000
Green (RoHS
& no Sb/Br)
CU NIPDAU
Level-1-260C-UNLIM
TLC2543C
TLC2543CDWRG4
ACTIVE
SOIC
DW
20
2000
Green (RoHS
& no Sb/Br)
CU NIPDAU
Level-1-260C-UNLIM
TLC2543C
TLC2543CFN
ACTIVE
PLCC
FN
20
46
Green (RoHS
& no Sb/Br)
CU SN
Level-1-260C-UNLIM
TLC2543C
TLC2543CFNG3
ACTIVE
PLCC
FN
20
46
Green (RoHS
& no Sb/Br)
CU SN
Level-1-260C-UNLIM
TLC2543C
TLC2543CFNR
ACTIVE
PLCC
FN
20
1000
Green (RoHS
& no Sb/Br)
CU SN
Level-1-260C-UNLIM
TLC2543C
TLC2543CFNRG3
ACTIVE
PLCC
FN
20
1000
Green (RoHS
& no Sb/Br)
CU SN
Level-1-260C-UNLIM
TLC2543C
TLC2543CN
ACTIVE
PDIP
N
20
20
Pb-Free
(RoHS)
CU NIPDAU
N / A for Pkg Type
TLC2543CN
TLC2543CNE4
ACTIVE
PDIP
N
20
20
Pb-Free
(RoHS)
CU NIPDAU
N / A for Pkg Type
TLC2543CN
TLC2543IDB
ACTIVE
SSOP
DB
20
70
Green (RoHS
& no Sb/Br)
CU NIPDAU
Level-1-260C-UNLIM
Addendum-Page 1
-55 to 125
5962-9688601QR
A
TLC2543MJB
Y2543
Samples
PACKAGE OPTION ADDENDUM
www.ti.com
24-Jan-2013
Orderable Device
Status
(1)
Package Type Package Pins Package Qty
Drawing
Eco Plan
Lead/Ball Finish
(2)
MSL Peak Temp
Op Temp (°C)
Top-Side Markings
(3)
(4)
TLC2543IDBG4
ACTIVE
SSOP
DB
20
70
Green (RoHS
& no Sb/Br)
CU NIPDAU
Level-1-260C-UNLIM
Y2543
TLC2543IDBR
ACTIVE
SSOP
DB
20
2000
Green (RoHS
& no Sb/Br)
CU NIPDAU
Level-1-260C-UNLIM
Y2543
TLC2543IDBRG4
ACTIVE
SSOP
DB
20
2000
Green (RoHS
& no Sb/Br)
CU NIPDAU
Level-1-260C-UNLIM
Y2543
TLC2543IDW
ACTIVE
SOIC
DW
20
25
Green (RoHS
& no Sb/Br)
CU NIPDAU
Level-1-260C-UNLIM
TLC2543I
TLC2543IDWG4
ACTIVE
SOIC
DW
20
25
Green (RoHS
& no Sb/Br)
CU NIPDAU
Level-1-260C-UNLIM
TLC2543I
TLC2543IDWR
ACTIVE
SOIC
DW
20
2000
Green (RoHS
& no Sb/Br)
CU NIPDAU
Level-1-260C-UNLIM
TLC2543I
TLC2543IDWRG4
ACTIVE
SOIC
DW
20
2000
Green (RoHS
& no Sb/Br)
CU NIPDAU
Level-1-260C-UNLIM
TLC2543I
TLC2543IFN
ACTIVE
PLCC
FN
20
46
Green (RoHS
& no Sb/Br)
CU SN
Level-1-260C-UNLIM
TLC2543I
TLC2543IFNG3
ACTIVE
PLCC
FN
20
46
Green (RoHS
& no Sb/Br)
CU SN
Level-1-260C-UNLIM
TLC2543I
TLC2543IFNR
OBSOLETE
PLCC
FN
20
TBD
Call TI
Call TI
TLC2543IN
ACTIVE
PDIP
N
20
20
Pb-Free
(RoHS)
CU NIPDAU
N / A for Pkg Type
TLC2543IN
TLC2543INE4
ACTIVE
PDIP
N
20
20
Pb-Free
(RoHS)
CU NIPDAU
N / A for Pkg Type
TLC2543IN
TLC2543MJ
ACTIVE
CDIP
J
20
1
TBD
A42
N / A for Pkg Type
-55 to 125
TLC2543MJ
TLC2543MJB
ACTIVE
CDIP
J
20
1
TBD
A42
N / A for Pkg Type
-55 to 125
5962-9688601QR
A
TLC2543MJB
(1)
The marketing status values are defined as follows:
ACTIVE: Product device recommended for new designs.
LIFEBUY: TI has announced that the device will be discontinued, and a lifetime-buy period is in effect.
NRND: Not recommended for new designs. Device is in production to support existing customers, but TI does not recommend using this part in a new design.
PREVIEW: Device has been announced but is not in production. Samples may or may not be available.
OBSOLETE: TI has discontinued the production of the device.
Addendum-Page 2
Samples
PACKAGE OPTION ADDENDUM
www.ti.com
24-Jan-2013
(2)
Eco Plan - The planned eco-friendly classification: Pb-Free (RoHS), Pb-Free (RoHS Exempt), or Green (RoHS & no Sb/Br) - please check http://www.ti.com/productcontent for the latest availability
information and additional product content details.
TBD: The Pb-Free/Green conversion plan has not been defined.
Pb-Free (RoHS): TI's terms "Lead-Free" or "Pb-Free" mean semiconductor products that are compatible with the current RoHS requirements for all 6 substances, including the requirement that
lead not exceed 0.1% by weight in homogeneous materials. Where designed to be soldered at high temperatures, TI Pb-Free products are suitable for use in specified lead-free processes.
Pb-Free (RoHS Exempt): This component has a RoHS exemption for either 1) lead-based flip-chip solder bumps used between the die and package, or 2) lead-based die adhesive used between
the die and leadframe. The component is otherwise considered Pb-Free (RoHS compatible) as defined above.
Green (RoHS & no Sb/Br): TI defines "Green" to mean Pb-Free (RoHS compatible), and free of Bromine (Br) and Antimony (Sb) based flame retardants (Br or Sb do not exceed 0.1% by weight
in homogeneous material)
(3)
MSL, Peak Temp. -- The Moisture Sensitivity Level rating according to the JEDEC industry standard classifications, and peak solder temperature.
(4)
Only one of markings shown within the brackets will appear on the physical device.
Important Information and Disclaimer:The information provided on this page represents TI's knowledge and belief as of the date that it is provided. TI bases its knowledge and belief on information
provided by third parties, and makes no representation or warranty as to the accuracy of such information. Efforts are underway to better integrate information from third parties. TI has taken and
continues to take reasonable steps to provide representative and accurate information but may not have conducted destructive testing or chemical analysis on incoming materials and chemicals.
TI and TI suppliers consider certain information to be proprietary, and thus CAS numbers and other limited information may not be available for release.
In no event shall TI's liability arising out of such information exceed the total purchase price of the TI part(s) at issue in this document sold by TI to Customer on an annual basis.
OTHER QUALIFIED VERSIONS OF TLC2543, TLC2543M :
• Catalog: TLC2543
• Automotive: TLC2543-Q1, TLC2543-Q1
• Enhanced Product: TLC2543-EP, TLC2543-EP
• Military: TLC2543M
NOTE: Qualified Version Definitions:
• Catalog - TI's standard catalog product
• Automotive - Q100 devices qualified for high-reliability automotive applications targeting zero defects
• Enhanced Product - Supports Defense, Aerospace and Medical Applications
Addendum-Page 3
PACKAGE OPTION ADDENDUM
www.ti.com
24-Jan-2013
• Military - QML certified for Military and Defense Applications
Addendum-Page 4
PACKAGE MATERIALS INFORMATION
www.ti.com
5-Feb-2013
TAPE AND REEL INFORMATION
*All dimensions are nominal
Device
TLC2543CDBR
Package Package Pins
Type Drawing
SPQ
Reel
Reel
A0
Diameter Width (mm)
(mm) W1 (mm)
B0
(mm)
K0
(mm)
P1
(mm)
W
Pin1
(mm) Quadrant
SSOP
DB
20
2000
330.0
16.4
8.2
7.5
2.5
12.0
16.0
Q1
TLC2543CDWR
SOIC
DW
20
2000
330.0
24.4
10.8
13.3
2.7
12.0
24.0
Q1
TLC2543IDBR
SSOP
DB
20
2000
330.0
16.4
8.2
7.5
2.5
12.0
16.0
Q1
TLC2543IDWR
SOIC
DW
20
2000
330.0
24.4
10.8
13.3
2.7
12.0
24.0
Q1
Pack Materials-Page 1
PACKAGE MATERIALS INFORMATION
www.ti.com
5-Feb-2013
*All dimensions are nominal
Device
Package Type
Package Drawing
Pins
SPQ
Length (mm)
Width (mm)
Height (mm)
TLC2543CDBR
SSOP
DB
20
2000
367.0
367.0
38.0
TLC2543CDWR
SOIC
DW
20
2000
367.0
367.0
45.0
TLC2543IDBR
SSOP
DB
20
2000
367.0
367.0
38.0
TLC2543IDWR
SOIC
DW
20
2000
367.0
367.0
45.0
Pack Materials-Page 2
MECHANICAL DATA
MPLC004A – OCTOBER 1994
FN (S-PQCC-J**)
PLASTIC J-LEADED CHIP CARRIER
20 PIN SHOWN
Seating Plane
0.004 (0,10)
0.180 (4,57) MAX
0.120 (3,05)
0.090 (2,29)
D
D1
0.020 (0,51) MIN
3
1
19
0.032 (0,81)
0.026 (0,66)
4
E
18
D2 / E2
E1
D2 / E2
8
14
0.021 (0,53)
0.013 (0,33)
0.007 (0,18) M
0.050 (1,27)
9
13
0.008 (0,20) NOM
D/E
D2 / E2
D1 / E1
NO. OF
PINS
**
MIN
MAX
MIN
MAX
MIN
MAX
20
0.385 (9,78)
0.395 (10,03)
0.350 (8,89)
0.356 (9,04)
0.141 (3,58)
0.169 (4,29)
28
0.485 (12,32)
0.495 (12,57)
0.450 (11,43)
0.456 (11,58)
0.191 (4,85)
0.219 (5,56)
44
0.685 (17,40)
0.695 (17,65)
0.650 (16,51)
0.656 (16,66)
0.291 (7,39)
0.319 (8,10)
52
0.785 (19,94)
0.795 (20,19)
0.750 (19,05)
0.756 (19,20)
0.341 (8,66)
0.369 (9,37)
68
0.985 (25,02)
0.995 (25,27)
0.950 (24,13)
0.958 (24,33)
0.441 (11,20)
0.469 (11,91)
84
1.185 (30,10)
1.195 (30,35)
1.150 (29,21)
1.158 (29,41)
0.541 (13,74)
0.569 (14,45)
4040005 / B 03/95
NOTES: A. All linear dimensions are in inches (millimeters).
B. This drawing is subject to change without notice.
C. Falls within JEDEC MS-018
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
1
MECHANICAL DATA
MSSO002E – JANUARY 1995 – REVISED DECEMBER 2001
DB (R-PDSO-G**)
PLASTIC SMALL-OUTLINE
28 PINS SHOWN
0,38
0,22
0,65
28
0,15 M
15
0,25
0,09
8,20
7,40
5,60
5,00
Gage Plane
1
14
0,25
A
0°–ā8°
0,95
0,55
Seating Plane
2,00 MAX
0,10
0,05 MIN
PINS **
14
16
20
24
28
30
38
A MAX
6,50
6,50
7,50
8,50
10,50
10,50
12,90
A MIN
5,90
5,90
6,90
7,90
9,90
9,90
12,30
DIM
4040065 /E 12/01
NOTES: A.
B.
C.
D.
All linear dimensions are in millimeters.
This drawing is subject to change without notice.
Body dimensions do not include mold flash or protrusion not to exceed 0,15.
Falls within JEDEC MO-150
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
IMPORTANT NOTICE
Texas Instruments Incorporated and its subsidiaries (TI) reserve the right to make corrections, enhancements, improvements and other
changes to its semiconductor products and services per JESD46, latest issue, and to discontinue any product or service per JESD48, latest
issue. Buyers should obtain the latest relevant information before placing orders and should verify that such information is current and
complete. All semiconductor products (also referred to herein as “components”) are sold subject to TI’s terms and conditions of sale
supplied at the time of order acknowledgment.
TI warrants performance of its components to the specifications applicable at the time of sale, in accordance with the warranty in TI’s terms
and conditions of sale of semiconductor products. Testing and other quality control techniques are used to the extent TI deems necessary
to support this warranty. Except where mandated by applicable law, testing of all parameters of each component is not necessarily
performed.
TI assumes no liability for applications assistance or the design of Buyers’ products. Buyers are responsible for their products and
applications using TI components. To minimize the risks associated with Buyers’ products and applications, Buyers should provide
adequate design and operating safeguards.
TI does not warrant or represent that any license, either express or implied, is granted under any patent right, copyright, mask work right, or
other intellectual property right relating to any combination, machine, or process in which TI components or services are used. Information
published by TI regarding third-party products or services does not constitute a license to use such products or services or a warranty or
endorsement thereof. Use of such information may require a license from a third party under the patents or other intellectual property of the
third party, or a license from TI under the patents or other intellectual property of TI.
Reproduction of significant portions of TI information in TI data books or data sheets is permissible only if reproduction is without alteration
and is accompanied by all associated warranties, conditions, limitations, and notices. TI is not responsible or liable for such altered
documentation. Information of third parties may be subject to additional restrictions.
Resale of TI components or services with statements different from or beyond the parameters stated by TI for that component or service
voids all express and any implied warranties for the associated TI component or service and is an unfair and deceptive business practice.
TI is not responsible or liable for any such statements.
Buyer acknowledges and agrees that it is solely responsible for compliance with all legal, regulatory and safety-related requirements
concerning its products, and any use of TI components in its applications, notwithstanding any applications-related information or support
that may be provided by TI. Buyer represents and agrees that it has all the necessary expertise to create and implement safeguards which
anticipate dangerous consequences of failures, monitor failures and their consequences, lessen the likelihood of failures that might cause
harm and take appropriate remedial actions. Buyer will fully indemnify TI and its representatives against any damages arising out of the use
of any TI components in safety-critical applications.
In some cases, TI components may be promoted specifically to facilitate safety-related applications. With such components, TI’s goal is to
help enable customers to design and create their own end-product solutions that meet applicable functional safety standards and
requirements. Nonetheless, such components are subject to these terms.
No TI components are authorized for use in FDA Class III (or similar life-critical medical equipment) unless authorized officers of the parties
have executed a special agreement specifically governing such use.
Only those TI components which TI has specifically designated as military grade or “enhanced plastic” are designed and intended for use in
military/aerospace applications or environments. Buyer acknowledges and agrees that any military or aerospace use of TI components
which have not been so designated is solely at the Buyer's risk, and that Buyer is solely responsible for compliance with all legal and
regulatory requirements in connection with such use.
TI has specifically designated certain components as meeting ISO/TS16949 requirements, mainly for automotive use. In any case of use of
non-designated products, TI will not be responsible for any failure to meet ISO/TS16949.
Products
Applications
Audio
www.ti.com/audio
Automotive and Transportation
www.ti.com/automotive
Amplifiers
amplifier.ti.com
Communications and Telecom
www.ti.com/communications
Data Converters
dataconverter.ti.com
Computers and Peripherals
www.ti.com/computers
DLP® Products
www.dlp.com
Consumer Electronics
www.ti.com/consumer-apps
DSP
dsp.ti.com
Energy and Lighting
www.ti.com/energy
Clocks and Timers
www.ti.com/clocks
Industrial
www.ti.com/industrial
Interface
interface.ti.com
Medical
www.ti.com/medical
Logic
logic.ti.com
Security
www.ti.com/security
Power Mgmt
power.ti.com
Space, Avionics and Defense
www.ti.com/space-avionics-defense
Microcontrollers
microcontroller.ti.com
Video and Imaging
www.ti.com/video
RFID
www.ti-rfid.com
OMAP Applications Processors
www.ti.com/omap
TI E2E Community
e2e.ti.com
Wireless Connectivity
www.ti.com/wirelessconnectivity
Mailing Address: Texas Instruments, Post Office Box 655303, Dallas, Texas 75265
Copyright © 2013, Texas Instruments Incorporated