TI TLV2543CDBG4

TLV2543C, TLV2543I
12-BIT ANALOG-TO-DIGITAL CONVERTERS
WITH SERIAL CONTROL AND 11 ANALOG INPUTS
SLAS096C – MARCH 1995 – REVISED JUNE 2000
D
D
D
D
D
D
D
D
D
D
D
D
D
12-Bit-Resolution A/D Converter
10-µs Conversion Time Over Operating
Temperature Range
11 Analog Input Channels
3 Built-In Self-Test Modes
Inherent Sample and Hold Function
Linearity Error . . . ± 1 LSB Max
On-Chip System Clock
End-of-Conversion (EOC) Output
Unipolar or Bipolar Output Operation
(Signed Binary With Respect to Half of the
Applied Referenced Voltage)
Programmable MSB or LSB First
Programmable Power Down
Programmable Output Data Length
CMOS Technology
DB, DW, OR N PACKAGE
(TOP VIEW)
AIN0
AIN1
AIN2
AIN3
AIN4
AIN5
AIN6
AIN7
AIN8
GND
1
20
2
19
3
18
4
17
5
16
6
15
7
14
8
13
9
12
10
11
VCC
EOC
I/O CLOCK
DATA INPUT
DATA OUT
CS
REF +
REF –
AIN10
AIN9
description
The TLV2543C and TLV2543I are 12-bit, switched-capacitor, successive-approximation, analog-to-digital
converters (ADCs). Each device has three control inputs [chip select (CS), the input-output clock (I/O CLOCK),
and the address input (DATA INPUT)] and is designed for communication with the serial port of a host processor
or peripheral through a serial 3-state output. The device allows high-speed data transfers from the host.
In addition to the high-speed converter and versatile control capability, the device has an on-chip 14-channel
multiplexer that can select any one of 11 inputs or any one of three internal self-test voltages. The
sample-and-hold function is automatic. At the end of conversion, the end-of-conversion (EOC) output goes high
to indicate that conversion is complete. The converter incorporated in the device features differential
high-impedance reference inputs that facilitate ratiometric conversion, scaling, and isolation of analog circuitry
from logic and supply noise. A switched-capacitor design allows low-error conversion over the full operating
temperature range.
The TLV2543 is available in the DW, DB, and N packages. The TLV2543C is characterized for operation from
0°C to 70°C, and the TLV2543I is characterized for operation from – 40°C to 85°C.
AVAILABLE OPTIONS
PACKAGE
TA
SMALL OUTLINE
PLASTIC DIP
DW †
DB†
N
0°C to 70°C
TLV2543CDW
TLV2543CDB
TLV2543CN
– 40°C to 85°C
TLV2543IDW
TLV2543IDB
TLV2543IN
† Available in tape and reel and ordered as the TLV2543CDWR, TLV2543CDBLE, TLV2543IDBR, or
TLV2543IDWR.
Please be aware that an important notice concerning availability, standard warranty, and use in critical applications of
Texas Instruments semiconductor products and disclaimers thereto appears at the end of this data sheet.
Copyright  2000, Texas Instruments Incorporated
PRODUCTION DATA information is current as of publication date.
Products conform to specifications per the terms of Texas Instruments
standard warranty. Production processing does not necessarily include
testing of all parameters.
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
1
TLV2543C, TLV2543I
12-BIT ANALOG-TO-DIGITAL CONVERTERS
WITH SERIAL CONTROL AND 11 ANALOG INPUTS
SLAS096C – MARCH 1995 – REVISED JUNE 2000
functional block diagram
AIN0
AIN1
AIN2
AIN3
AIN4
AIN5
AIN6
AIN7
AIN8
AIN9
AIN10
1
2
3
4
5
6
7
8
9
11
12
Sample and
Hold
14-Channel
Analog
Multiplexer
REF +
REF –
14
13
12-Bit
Analog-to-Digital
Converter
(switched capacitors)
12
4
Input Address
Register
Output
Data
Register
12
12-to-1 Data
Selector and
Driver
16
DATA
OUT
4
3
Control Logic
and I/O
Counters
Self-Test
Reference
19
DATA
INPUT
I/O CLOCK
CS
2
17
18
15
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
EOC
TLV2543C, TLV2543I
12-BIT ANALOG-TO-DIGITAL CONVERTERS
WITH SERIAL CONTROL AND 11 ANALOG INPUTS
SLAS096C – MARCH 1995 – REVISED JUNE 2000
Terminal Functions
TERMINAL
I/O
DESCRIPTION
1 – 9,
11, 12
I
Analog input. These 11 analog-signal inputs are internally multiplexed. The driving source impedance should
be less than or equal to 50 Ω for 4.1-MHz I/O CLOCK operation and capable of slewing the analog input
voltage into a capacitance of 60 pF.
CS
15
I
Chip select. A high-to-low transition on CS resets the internal counters and controls and enables DATA OUT,
DATA INPUT, and I/O CLOCK. A low-to-high transition disables DATA INPUT and I/O CLOCK within a setup
time.
DATA INPUT
17
I
Serial-data input. A 4-bit serial address selects the desired analog input or test voltage to be converted. The
serial data is presented with the MSB first and is shifted in on the first four rising edges of I/O CLOCK. After
the four address bits are read into the address register, I/O CLOCK clocks the remaining bits in order.
DATA OUT
16
O
Serial data output. This is the 3-state serial output for the A/D conversion result. DATA OUT is in the
high-impedance state when CS is high and active when CS is low. With a valid CS, DATA OUT is removed
from the high-impedance state and is driven to the logic level corresponding to the MSB/LSB value of the
previous conversion result. The next falling edge of I/O CLOCK drives DATA OUT to the logic level
corresponding to the next MSB / LSB, and the remaining bits are shifted out in order.
EOC
19
O
End of conversion. EOC goes from a high to a low logic level after the falling edge of the last I/O CLOCK and
remains low until the conversion is complete and data are ready for transfer.
GND
10
I/O CLOCK
18
I
Input /output clock. I/O CLOCK receives the serial input and performs the following four functions:
1. It clocks the eight input data bits into the input data register on the first eight rising edges of I/O CLOCK
with the multiplexer address available after the fourth rising edge.
2. On the fourth falling edge of I/O CLOCK, the analog input voltage on the selected multiplexer input
begins charging the capacitor array and continues to do so until the last falling edge of I/O
CLOCK.
3. It shifts the 11 remaining bits of the previous conversion data out on DATA OUT. Data changes on
the falling edge of I/O CLOCK.
4. It transfers control of the conversion to the internal state controller on the falling edge of the last
I/O CLOCK.
REF +
14
I
Reference +. The upper reference voltage value (nominally VCC) is applied to REF+. The maximum input
voltage range is determined by the difference between the voltage applied to this terminal and the voltage
applied to the REF – terminal.
REF –
13
I
Reference –. The lower reference voltage value (nominally ground) is applied to REF –.
VCC
20
NAME
NO.
AIN0 – AIN10
Ground. This is the ground return terminal for the internal circuitry. Unless otherwise noted, all voltage
measurements are with respect to GND.
Positive supply voltage.
detailed description
Initially, with chip select (CS) high, I/O CLOCK and DATA INPUT are disabled and DATA OUT is in the
high-impedance state. CS, going low, begins the conversion sequence by enabling I/O CLOCK and DATA
INPUT and removes DATA OUT from the high-impedance state.
The input data is an 8-bit data stream consisting of a 4-bit analog channel address (D7 – D4), a 2-bit data length
select (D3 – D2), an output MSB or LSB first bit (D1), and a unipolar or bipolar output select bit (D0) that are
applied to DATA INPUT. The I/O CLOCK sequence applied to the I/O CLOCK terminal transfers this data to the
input data register.
During this transfer, the I/O CLOCK sequence also shifts the previous conversion result from the output data
register to DATA OUT. I/O CLOCK receives the input sequence of 8, 12, or 16 clocks long depending on the
data-length selection in the input data register. Sampling of the analog input begins on the fourth falling edge
of the input I/O CLOCK sequence and is held after the last falling edge of the I/O CLOCK sequence. The last
falling edge of the I/O CLOCK sequence also takes EOC low and begins the conversion.
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
3
TLV2543C, TLV2543I
12-BIT ANALOG-TO-DIGITAL CONVERTERS
WITH SERIAL CONTROL AND 11 ANALOG INPUTS
SLAS096C – MARCH 1995 – REVISED JUNE 2000
converter operation
The operation of the converter is organized as a succession of two distinct cycles: 1) the I/O cycle, and 2) the
actual conversion cycle. The I/O cycle is defined by the externally provided I/O CLOCK and lasts 8, 12, or 16
clock periods depending on the selected output data length.
1. I/O cycle
During the I/O cycle, two operations take place simultaneously.
a. An 8-bit data stream consisting of address and control information is provided to DATA INPUT. This data
is shifted into the device on the rising edge of the first eight I/O CLOCKs. DATA INPUT is ignored after
the first eight clocks during 12- or 16-clock I/O transfers.
b. The data output with a length of 8, 12, or 16 bits is provided serially on DATA OUT. When CS is held low,
the first output data bit occurs on the rising edge of EOC. When CS is negated between conversions, the
first output data bit occurs on the falling edge of CS. This data is the result of the previous conversion
period, and after the first output data bit each succeeding bit is clocked out on the falling edge of each
succeeding I/O CLOCK.
2. Conversion cycle
The conversion cycle is transparent to the user, and it is controlled by an internal clock synchronized to the
I/O CLOCK. During the conversion period, the device performs a successive-approximation conversion on
the analog input voltage. The EOC output goes low at the start of the conversion cycle and goes high when
conversion is complete and the output data register is latched. A conversion cycle is started only after the I/O
cycle is completed, which minimizes the influence of external digital noise on the accuracy of the
conversion.
power up and initialization
After power up, CS must be taken from high to low to begin an I/O cycle. EOC is initially high, and the input data
register is set to all zeros. The contents of the output data register are random, and the first conversion result
should be ignored. To initialize during operation, CS is taken high and returned low to begin the next I/O cycle.
The first conversion after the device has returned from the power-down state may not read accurately due to
internal device settling.
operational terminology
Previous (N – 1) conversion cycle
The conversion cycle prior to the current I/O cycle.
Current (N) I/O cycle
The entire I/O CLOCK sequence that transfers address and control data into the data register and clocks
the digital result from the previous conversion cycle from DATA OUT. The last falling edge of the clock in
the I/O CLOCK sequence signifies the end of the current I/O cycle.
Current (N) conversion cycle
Immediately after the current I/O cycle, the current conversion cycle starts. When the current conversion
cycle is complete, the current conversion result is loaded into the output register.
Current (N) conversion result
The result of the current conversion cycle that is serially shifted out during the next I/O cycle.
Next (N + 1) I/O cycle
The I/O cycle after the current conversion cycle.
Example: In the 12-bit mode, the result of the current conversion cycle is a 12-bit serial-data stream clocked out during
the next I/O cycle. The current I/O cycle must be exactly 12 bits long to maintain synchronization, even
when this corrupts the output data from the previous conversion. The current conversion begins
immediately after the twelfth falling edge of the current I/O cycle.
data input
The data input is internally connected to an 8-bit serial-input address and control register. The register defines
the operation of the converter and the output data length. The host provides the data word with the MSB first.
Each data bit is clocked in on the rising edge of the I/O CLOCK sequence (see Table 1 for the data register
format).
4
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
TLV2543C, TLV2543I
12-BIT ANALOG-TO-DIGITAL CONVERTERS
WITH SERIAL CONTROL AND 11 ANALOG INPUTS
SLAS096C – MARCH 1995 – REVISED JUNE 2000
data input (continued)
Table 1. Input-Register Format
INPUT DATA BYTE
ADDRESS BITS
FUNCTION SELECT
Select input channel
AIN0
AIN1
AIN2
AIN3
AIN4
AIN5
AIN6
AIN7
AIN8
AIN9
AIN10
Select test voltage
(Vref + – Vref –)/2
Vref –
Vref +
Software power down
D7
(MSB)
D6
D5
D4
0
0
0
0
0
0
0
0
1
1
1
0
0
0
0
1
1
1
1
0
0
0
0
0
1
1
0
0
1
1
0
0
1
0
1
0
1
0
1
0
1
0
1
0
1
1
1
0
1
1
1
0
0
1
0
1
1
1
1
0
Output data length
8 bits
12 bits
16 bits
Output data format
MSB first
LSB first
L1
L0
LSBF
BIP
D3
D2
D1
D0
(LSB)
0
X
1
1
0
1
0
1
Unipolar (binary)
0
Bipolar (BIP, 2s complement)
1
data input address bits
The four MSBs (D7 – D4) of the data register address one of the 11 input channels, a reference-test voltage,
or the power-down mode. The address bits affect the current conversion, which is the conversion that
immediately follows the current I/O cycle. The reference voltage is nominally equal to Vref+ – Vref –.
data output length
The next two bits (D3 and D2) of the data register select the output data length. The data-length selection is
valid for the current I/O cycle (the cycle in which the data is read). The data-length selection, which is valid for
the current I/O cycle, allows device start-up without losing I/O synchronization. A data length of 8, 12, or 16 bits
can be selected. Since the converter has 12-bit resolution, a data length of 12 bits is suggested.
With D3 and D2 set to 00 or 10, the device is in the 12-bit data-length mode and the result of the current
conversion is output as a 12-bit serial-data stream during the next I/O cycle. The current I/O cycle must be
exactly 12 bits long for proper synchronization, even when this means corrupting the output data from a previous
conversion. The current conversion is started immediately after the twelfth falling edge of the current I/O cycle.
With bits D3 and D2 set to 11, the 16-bit data-length mode is selected, which allows convenient communication
with 16-bit serial interfaces. In the 16-bit mode, the result of the current conversion is output as a 16-bit
serial-data stream during the next I/O cycle with the four LSBs always set to 0 (pad bits). The current I/O cycle
must be exactly 16 bits long to maintain synchronization even when this means corrupting the output data from
the previous conversion. The current conversion is started immediately after the sixteenth falling edge of the
current I/O cycle.
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
5
TLV2543C, TLV2543I
12-BIT ANALOG-TO-DIGITAL CONVERTERS
WITH SERIAL CONTROL AND 11 ANALOG INPUTS
SLAS096C – MARCH 1995 – REVISED JUNE 2000
data output length (continued)
With bits D3 and D2 set to 01, the 8-bit data-length mode is selected, which allows fast communication with 8-bit
serial interfaces. In the 8-bit mode, the result of the current conversion is output as an 8-bit serial-data stream
during the next I/O cycle. The current I/O cycle must be exactly 8 bits long to maintain synchronization, even
when this means corrupting the output data from the previous conversion. The four LSBs of the conversion
result are truncated and discarded. The current conversion is immediately started after the eighth falling edge
of the current I/O cycle.
Since D3 and D2 take effect on the current I/O cycle when the data length is programmed, there can be a conflict
with the previous cycle when the data-word length is changed from one cycle to the next. This may occur when
the data format is selected to be least significant bit first, since at the time the data length change becomes
effective (six rising edges of I/O CLOCK), the previous conversion result has already started shifting out.
In actual operation, when different data lengths are required within an application and the data length is changed
between two conversions, no more than one conversion result can be corrupted and only when it is shifted out
in LSB first format.
sampling period
During the sampling period, one of the analog inputs is internally connected to the capacitor array of the
converter to store the analog input signal. The converter starts sampling the selected input immediately after
the four address bits have been clocked into the input data register. Sampling starts on the fourth falling edge
of I/O CLOCK. The converter remains in the sampling mode until the eighth, twelfth, or sixteenth falling edge
of the I/O CLOCK depending on the data-length selection. After the EOC delay time from the last I/O CLOCK
falling edge, the EOC output goes low indicating that the sampling period is over and the conversion period has
begun. After EOC goes low, the analog input can be changed without affecting the conversion result. Since the
delay from the falling edge of the last I/O CLOCK to EOC low is fixed, time-varying analog input signals can be
digitized at a fixed rate without introducing systematic harmonic distortion or noise due to timing uncertainty.
After the 8-bit data stream has been clocked in, DATA INPUT should be held at a fixed digital level until EOC
goes high (indicating that the conversion is complete) to maximize the sampling accuracy and minimize the
influence of external digital noise.
data register, LSB first
D1 in the input data register (LSB first) controls the direction of the output binary data transfer. When D1 is set
to 0, the conversion result shifts out MSB first. When set to 1, the data shifts out LSB first. Selection of MSB
first or LSB first always affects the next I/O cycle and not the current I/O cycle. When changing from one data
direction to another, the current I/O cycle is never disrupted.
data register, bipolar format
D0 in the input data register controls the binary data format used to represent the conversion result. When D0
is set to 0, the conversion result is represented as unipolar (unsigned binary) data. Nominally, the conversion
result of an input voltage equal to Vref – is a code of all zeros (000 . . . 0), the conversion result of an input voltage
equal to Vref + is a code of all ones (111 . . . 1), and the conversion result of (Vref + + Vref – ) /2 is a code of a one
followed by zeros (100 . . . 0).
When D0 is set to 1, the conversion result is represented as bipolar data (signed binary). Nominally, conversion
of an input voltage equal to Vref – is a code of a 1 followed by zeros (100 . . . 0), conversion of an input voltage
equal to Vref + is a code of a 0 followed by all ones (011 . . . 1), and the conversion of (Vref + + Vref –) /2 is a code
of all zeros (000 . . . 0). The MSB is interpreted as the sign bit. The bipolar data format is related to the unipolar
format in that the MSBs are always each other’s complement.
Selection of the unipolar or bipolar format always affects the current conversion cycle, and the result is output
during the next I/O cycle. When changing between unipolar and bipolar formats, the data output during the
current I/O cycle is not affected.
6
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
TLV2543C, TLV2543I
12-BIT ANALOG-TO-DIGITAL CONVERTERS
WITH SERIAL CONTROL AND 11 ANALOG INPUTS
SLAS096C – MARCH 1995 – REVISED JUNE 2000
EOC output
The EOC signal indicates the beginning and the end of conversion. In the reset state, EOC is always high. During
the sampling period (beginning after the fourth falling edge of the I/O CLOCK sequence), EOC remains high
until the internal sampling switch of the converter is safely opened. The opening of the sampling switch occurs
after the eighth, twelfth, or sixteenth I/O CLOCK falling edge, depending on the data-length selection in the input
data register. After the EOC signal goes low, the analog input signal can be changed without affecting the
conversion result.
The EOC signal goes high again after the conversion completes and the conversion result is latched into the
output data register. The rising edge of EOC returns the converter to a reset state and a new I/O cycle begins.
On the rising edge of EOC, the first bit of the current conversion result is on DATA OUT when CS is low. When
CS is negated between conversions, the first bit of the current conversion result occurs at DATA OUT on the
falling edge of CS.
data format and pad bits
D3 and D2 of the input data register determine the number of significant bits in the digital output that represent
the conversion result. The LSB-first bit determines the direction of the data transfer while the BIP bit determines
the arithmetic conversion. The numerical data is always justified toward the MSB in any output format.
The internal conversion result is always 12 bits long. When an 8-bit data transfer is selected, the four LSBs of
the internal result are discarded to provide a faster one-byte transfer. When a 12-bit transfer is used, all bits are
transferred. When a 16-bit transfer is used, four LSB pad bits are always appended to the internal conversion
result. In the LSB-first mode, four leading zeros are output. In the MSB-first mode, the last four bits output are
zeros.
When CS is held low continuously, the first data bit of the just completed conversion occurs on DATA OUT on
the rising edge of EOC. When a new conversion is started after the last falling edge of I/O CLOCK, EOC goes
low and the serial output is forced to a logic zero until EOC goes high again.
When CS is negated between conversions, the first data bit occurs on DATA OUT on the falling edge of CS.
On each subsequent falling edge of I/O CLOCK after the first data bit appears, the data is changed to the next
bit in the serial conversion result until the required number of bits has been output.
chip-select input (CS)
The chip-select input (CS) enables and disables the device. During normal operation, CS should be low.
Although the use of CS is not necessary to synchronize a data transfer, it can be brought high between
conversions to coordinate the data transfer of several devices sharing the same bus.
When CS is brought high, the serial-data output is immediately brought to the high-impedance state, releasing
its output data line to other devices that may share it. After an internally generated debounce time, the I/O
CLOCK is inhibited, thus preventing any further change in the internal state.
When CS is subsequently brought low again, the device is reset. CS must be held low for an internal debounce
time before the reset operation takes effect. After CS is debounced low, I/O CLOCK must remain inactive (low)
for a minimum time before a new I/O cycle can start.
CS can be used to interrupt any ongoing data transfer or any ongoing conversion. When CS is debounced low
long enough before the end of the current conversion cycle, the previous conversion result is saved in the
internal output buffer and then shifted out during the next I/O cycle.
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
7
TLV2543C, TLV2543I
12-BIT ANALOG-TO-DIGITAL CONVERTERS
WITH SERIAL CONTROL AND 11 ANALOG INPUTS
SLAS096C – MARCH 1995 – REVISED JUNE 2000
power-down features
When a binary address of 1110 is clocked into the input data register during the first four I/O CLOCK cycles,
the power-down mode is selected. Power down is activated on the falling edge of the fourth I/O CLOCK pulse.
During power down, all internal circuitry is put in a low-current standby mode. No conversions are performed,
and the internal output buffer keeps the previous conversion cycle data results, provided that all digital inputs
are held above VCC – 0.3 V or below 0.3 V. The I/O logic remains active so the current I/O cycle must be
completed even when the power-down mode is selected. Upon power-on reset and before the first I/O cycle,
the converter normally begins in the power-down mode. The device remains in the power-down mode until a
valid (other than 1110) input address clocks in. Upon completion of that I/O cycle, a normal conversion is
performed with the results being shifted out during the next I/O cycle.
analog input, test, and power-down mode
The 11 analog inputs, three internal voltages, and power-down mode are selected by the input multiplexer
according to the input addresses shown in Tables 2, 3, and 4. The input multiplexer is a break-before-make type
to reduce input-to-input noise rejection resulting from channel switching. Sampling of the analog input starts on
the falling edge of the fourth I/O CLOCK and continues for the remaining I/O CLOCK pulses. The sample is held
on the falling edge of the last I/O CLOCK pulse. The three internal test inputs are applied to the multiplexer,
sampled, and converted in the same manner as the external analog inputs. The first conversion after the device
has returned from the power-down state may not read accurately due to internal device settling.
Table 2. Analog-Channel-Select Address
ANALOG INPUT
SELECTED
VALUE SHIFTED INTO
DATA INPUT
BINARY
HEX
AIN0
0000
0
AIN1
0001
1
AIN2
0010
2
AIN3
0011
3
AIN4
0100
4
AIN5
0101
5
AIN6
0110
6
AIN7
0111
7
AIN8
1000
8
AIN9
1001
9
AIN10
1010
A
Table 3. Test-Mode-Select Address
INTERNAL
SELF-TEST
VOLTAGE
SELECTED†
Vref + – Vref –
2
VALUE SHIFTED INTO
DATA INPUT
BINARY
HEX
1011
B
UNIPOLAR OUTPUT
RESULT (HEX)‡
200
Vref –
1100
C
000
Vref +
1101
D
3FF
† Vref + is the voltage applied to REF +, and Vref – is the voltage applied to REF –.
‡ The output results shown are the ideal values and may vary with the reference stability
and with internal offsets.
8
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
TLV2543C, TLV2543I
12-BIT ANALOG-TO-DIGITAL CONVERTERS
WITH SERIAL CONTROL AND 11 ANALOG INPUTS
SLAS096C – MARCH 1995 – REVISED JUNE 2000
analog input, test, and power-down mode (continued)
Table 4. Power-Down-Select Address
VALUE SHIFTED INTO
DATA INPUT
INPUT COMMAND
Power down
BINARY
HEX
1110
E
RESULT
ICC ≤ 25 µA
converter and analog input
The CMOS threshold detector in the successive-approximation conversion system determines each bit by
examining the charge on a series of binary-weighted capacitors (see Figure 1). In the first phase of the
conversion process, the analog input is sampled by closing the SC switch and all ST switches simultaneously.
This action charges all the capacitors to the input voltage.
In the next phase of the conversion process, all ST and SC switches are opened and the threshold detector
begins identifying bits by identifying the charge (voltage) on each capacitor relative to the reference (REF –)
voltage. In the switching sequence, 12 capacitors are examined separately until all 12 bits are identified and
the charge-convert sequence is repeated. In the first step of the conversion phase, the threshold detector looks
at the first capacitor (weight = 4096). Node 4096 of this capacitor is switched to the REF+ voltage, and the
equivalent nodes of all the other capacitors on the ladder are switched to REF –. When the voltage at the
summing node is greater than the trip point of the threshold detector (approximately one-half VCC ), a bit 0 is
placed in the output register and the 4096-weight capacitor is switched to REF –. When the voltage at the
summing node is less than the trip point of the threshold detector, a bit 1 is placed in the register and the
4096-weight capacitor remains connected to REF + through the remainder of the successive-approximation
process. The process is repeated for the 2048-weight capacitor, the 1024-weight capacitor, and so forth down
the line until all bits are determined. With each step of the successive-approximation process, the initial charge
is redistributed among the capacitors. The conversion process relies on charge redistribution to determine the
bits from MSB to LSB.
SC
Threshold
Detector
2048
4096
Node 4096
REF –
1024
REF+
REF+
REF –
ST
16
REF –
ST
8
REF+
REF –
ST
4
REF+
REF –
ST
REF+
REF –
ST
2
1
REF+
REF+
REF –
REF –
ST
ST
To Output
Latches
1
REF –
ST
ST
VI
Figure 1. Simplified Model of the Successive-Approximation System
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
9
TLV2543C, TLV2543I
12-BIT ANALOG-TO-DIGITAL CONVERTERS
WITH SERIAL CONTROL AND 11 ANALOG INPUTS
SLAS096C – MARCH 1995 – REVISED JUNE 2000
reference voltage inputs
There are two reference voltage inputs on the device, REF+ and REF –. The voltage values on these terminals
establish the upper and lower limits of the analog input to produce a full-scale and zero-scale reading
respectively. These voltages and the analog input should not exceed the positive supply or be lower than ground
consistent with the specified absolute maximum ratings. The digital output is at full scale when the input signal
is equal to or higher than REF+ terminal voltage and at zero when the input signal is equal to or lower than REF –
terminal voltage.
absolute maximum ratings over operating free-air temperature range (unless otherwise noted)†
Supply voltage range, VCC (see Note 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . – 0.5 V to 6.5 V
Input voltage range, VI (any input) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . – 0.3 V to VCC + 0.3 V
Output voltage range, VO . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . – 0.3 V to VCC + 0.3 V
Positive reference voltage, Vref + . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . VCC + 0.1 V
Negative reference voltage, Vref – . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . – 0.1 V
Peak input current, II (any input) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ± 20 mA
Peak total input current (all inputs) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ± 30 mA
Operating free-air temperature range, TA: TLV2543C . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0°C to 70°C
TLV2543I . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . – 40°C to 85°C
Storage temperature range, Tstg . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . – 65°C to 150°C
Lead temperature 1,6 mm (1/16 inch) from the case for 10 seconds . . . . . . . . . . . . . . . . . . . . . . . . . . . . 260°C
† Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and
functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
NOTE 1: All voltage values are with respect to the GND terminal with REF – and GND wired together (unless otherwise noted).
10
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
TLV2543C, TLV2543I
12-BIT ANALOG-TO-DIGITAL CONVERTERS
WITH SERIAL CONTROL AND 11 ANALOG INPUTS
SLAS096C – MARCH 1995 – REVISED JUNE 2000
recommended operating conditions
Supply voltage, VCC
MIN
NOM
MAX
3
3.3
3.6
Positive reference voltage, Vref + (see Note 2)
VCC
0
Negative reference voltage, Vref – (see Note 2)
Differential reference voltage, Vref + – Vref – (see Note 2)
2.5
Analog input voltage (see Note 2)
VCC
0
High-level control input voltage, VIH
VCC = 3 V to 3.6 V
VCC = 3 V to 3.6 V
Low-level control input voltage, VIL
Clock frequency at I/O CLOCK
Setup time, address bits at DATA INPUT before I/O CLOCK↑, tsu(A) (see Figure 5)
V
V
V
VCC + 0.1
VCC
2.1
0
UNIT
V
V
V
3
0.6
V
4.1
MHz
100
ns
Hold time, address bits at DATA INPUT after I/O CLOCK↑, th(A) (see Figure 5)
0
ns
Hold time, CS low after last I/O CLOCK↓, th(CS) (see Figure 6)
0
ns
1.425
µs
Pulse duration, I/O CLOCK high, twH(I/O)
190
ns
Pulse duration, I/O CLOCK low, twL(I/O)
190
Setup time, CS low before clocking in first address bit, tsu(CS) (see Note 3 and Figure 6)
Transition time, I/O CLOCK, tt(I/O) (see Note 4 and Figure 7)
Transition time, DATA INPUT and CS, tt(CS)
free air temperature,
temperature TA
Operating free-air
TLV2543C
TLV2543I
ns
1
µs
10
µs
0
70
– 40
85
°C
NOTES: 2. Analog input voltages greater than the voltage applied to REF+ convert as all ones (111111111111), while input voltages less than
the voltage applied to REF– convert as all zeros (000000000000).
3. To minimize errors caused by noise at the CS input, the internal circuitry waits for a setup time after CS↓ before responding to control
input signals. No attempt should be made to clock in an address until the minimum CS setup time elapses.
4. This is the time required for the clock input signal to fall from VIHmin to VILmax or to rise from VILmax to VIHmin. In the vicinity of
normal room temperature, the devices function with input clock transition time as slow as 1 µs for remote data acquisition applications
where the sensor and the A/D converter are placed several feet away from the controlling microprocessor.
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
11
TLV2543C, TLV2543I
12-BIT ANALOG-TO-DIGITAL CONVERTERS
WITH SERIAL CONTROL AND 11 ANALOG INPUTS
SLAS096C – MARCH 1995 – REVISED JUNE 2000
electrical characteristics over recommended operating free-air temperature range,
VCC = Vref+ = 3 V to 3.6 V (unless otherwise noted)
PARAMETER
TEST CONDITIONS
MIN
TYP†
MAX
VOH
High level output voltage
High-level
VCC = 3 V,
VCC = 3 V to 3.6 V,
IOH = – 0.2 mA
IOH = – 20 µA
VOL
Low level output voltage
Low-level
VCC = 3 V,
VCC = 3 V to 3.6 V,
IOL = 0.8 mA
IOL = 20 µA
IOZ
Off-state ((high-impedance-state)
g
)
output current
VO = VCC,
VO = 0,
VI = VCC
CS at VCC
1
2.5
CS at VCC
1
– 2.5
IIH
IIL
High-level input current
ICC
Operating supply current
Low-level input current
VI = 0
CS at 0 V
ICC(PD)
Power-down current
For all digital inputs,
0 ≤ VI ≤ 0.3 V or VI ≥ VCC – 0.3 V
Ilkg
lk
Selected channel leakage
g
current
Selected channel at VCC, Unselected channel at 0 V
Selected channel at 0 V, Unselected channel at VCC
Maximum static analog
reference current into REF +
Vref + = VCC,
Ci
Input
capacitance
Vref – = GND
V
VCC – 0.1
0.4
0.1
2.5
µA
– 2.5
µA
1
2.5
mA
4
25
µA
1
–1
Analog inputs
30
60
Control inputs
5
15
• DALLAS, TEXAS 75265
µA
1
2.5
POST OFFICE BOX 655303
V
1
1
† All typical values are at VCC = 5 V, TA = 25°C.
12
2.4
UNIT
µA
µA
pF
TLV2543C, TLV2543I
12-BIT ANALOG-TO-DIGITAL CONVERTERS
WITH SERIAL CONTROL AND 11 ANALOG INPUTS
SLAS096C – MARCH 1995 – REVISED JUNE 2000
operating characteristics over recommended operating free-air temperature range,
VCC = Vref+ = 3 V to 3.6 V, I/O CLOCK frequency = 4.1 MHz, (unless otherwise noted)
PARAMETER
TEST CONDITIONS
MIN
TYP†
MAX
UNIT
Linearity error (see Note 6)
See Figure 2
±1
LSB
Differential linearity error
See Figure 2
±1
LSB
EO
Offset error (see Note 7)
See Note 2 and
Figure 2
± 1.5
LSB
EG
Gain error (see Note 7)
See Note 2 and
Figure 2
±1
LSB
ET
Total unadjusted error (see Note 8)
± 1.75
LSB
EL
ED
DATA INPUT = 1011
Self-test output code (see Table 3 and Note 9)
DATA INPUT = 1100
DATA INPUT = 1101
t(conv)
2038
Conversion time
4075
See Figures 10 – 15
2048
2058
0
10
4095
8
10
10 + total
I/O CLOCK
periods +
td(I/O-EOC)
µs
tc
Total cycle time (access, sample, and conversion)
See Figures 10 – 15
and Note 10
tacq
Channel acquisition time (sample)
See Figures 10 – 15
and Note 10
tv
td(I/O-DATA)
Valid time, DATA OUT remains valid after I/O CLOCK↓
See Figure 7
Delay time, I/O CLOCK↓ to DATA OUT valid
See Figure 7
td(I/O-EOC)
td(EOC-DATA)
Delay time, last I/O CLOCK↓ to EOC↓
See Figure 8
Delay time, EOC↑ to DATA OUT (MSB / LSB)
See Figure 9
200
ns
tPZH, tPZL
tPHZ, tPLZ
Enable time, CS↓ to DATA OUT (MSB / LSB driven)
See Figure 4
0.7
1.3
µs
Disable time, CS↑ to DATA OUT (high impedance)
See Figure 4
70
150
ns
tr(EOC)
tf(EOC)
Rise time, EOC
See Figure 9
15
50
ns
Fall time, EOC
See Figure 8
15
50
ns
tr(bus)
tf(bus)
Rise time, data bus
See Figure 7
15
50
ns
Fall time, data bus
See Figure 7
15
50
ns
5
µs
td(I/O-CS)
Delay time, last I/O CLOCK↓ to CS↓ to abort conversion
(see Note 11)
4
12
10
µs
I/O
CLOCK
periods
ns
1.5
250
ns
2.2
µs
† All typical values are at TA = 25°C.
NOTES: 2. Analog input voltages greater than that applied to REF + convert as all ones (111111111111), while input voltages less than that
applied to REF – convert as all zeros (000000000000).
6. Linearity error is the maximum deviation from the best straight line through the A/D transfer characteristics.
7. Gain error is the difference between the actual midstep value and the nominal midstep value in the transfer diagram at the specified
gain point after the offset error has been adjusted to zero. Offset error is the difference between the actual midstep value and the
nominal midstep value at the offset point.
8. Total unadjusted error comprises linearity, zero-scale, and full-scale errors.
9. Both the input address and the output codes are expressed in positive logic.
10. I/O CLOCK period = 1 /(I/O CLOCK frequency) (see Figure 7).
11. Any transitions of CS are recognized as valid only when the level is maintained for a setup time. CS must be taken low at ≤ 5 µs
of the tenth I/O CLOCK falling edge to ensure that a conversion is aborted. Between 5 µs and 10 µs, the result is uncertain as to
whether the conversion is aborted or the conversion results are valid.
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
13
TLV2543C, TLV2543I
12-BIT ANALOG-TO-DIGITAL CONVERTERS
WITH SERIAL CONTROL AND 11 ANALOG INPUTS
SLAS096C – MARCH 1995 – REVISED JUNE 2000
PARAMETER MEASUREMENT INFORMATION
15 V
50 Ω
C1
10 µF
C2
0.1 µF
C3
470 pF
VI
C1
10 µF
TLV2543
10 Ω
_
U1
+
AIN0 – AIN10
C3
470 pF
C2
0.1 µF
50 Ω
– 15 V
LOCATION
U1
C1
C2
C3
DESCRIPTION
PART NUMBER
OP27
10-µF 35-V tantalum capacitor
0.1-µF ceramic NPO SMD capacitor
470-pF porcelain high-Q SMD capacitor
—
—
AVX 12105C104KA105 or equivalent
Johanson 201S420471JG4L or equivalent
Figure 2. Analog Input Buffer to Analog Inputs AIN0 – AIN10
Test Point
Isource
0.8 mA
See Note A
Output
Under Test
Vcp = 2 V
CL = 100 pF
Isink
– 0.2 mA
NOTE A: Equivalent load circuit of the Teradyne A580 tester for timing
parameter measurement.
Figure 3. Timing Load Circuits
Data
Valid
2V
CS
tPZH, tPZL
DATA
OUT
tPHZ, tPLZ
2.4 V
90%
0.4 V
10%
Figure 4. DATA OUT to Hi-Z Voltage Waveforms
14
2V
0.8 V
DATA INPUT
0.8 V
POST OFFICE BOX 655303
th(A)
tsu(A)
I/O CLOCK
0.8 V
Figure 5. DATA INPUT and I/O CLOCK
Voltage Waveforms
• DALLAS, TEXAS 75265
TLV2543C, TLV2543I
12-BIT ANALOG-TO-DIGITAL CONVERTERS
WITH SERIAL CONTROL AND 11 ANALOG INPUTS
SLAS096C – MARCH 1995 – REVISED JUNE 2000
PARAMETER MEASUREMENT INFORMATION
2V
CS
0.8 V
tsu(CS)
I/O CLOCK
th(CS)
Last
Clock
0.8 V
0.8 V
Figure 6. CS and I/O CLOCK Voltage Waveforms†
† To ensure full conversion accuracy, it is recommended that no input signal change occurs while
a conversion is ongoing.
tt(I/O)
tt(I/O)
2V
2V
I/O CLOCK
0.8 V
0.8 V
0.8 V
I/O CLOCK Period
td(I/O-DATA)
tv
2.4 V
0.4 V
DATA OUT
2.4 V
0.4 V
tr(bus), tf(bus)
Figure 7. I/O CLOCK and DATA OUT Voltage Waveforms
I/O CLOCK
Last
Clock
0.8 V
td(I/O-EOC)
2.4 V
EOC
0.4 V
tf(EOC)
Figure 8. I/O CLOCK and EOC Voltage Waveforms
tr(EOC)
EOC
2.4 V
0.4 V
td(EOC-DATA)
2.4 V
0.4 V
DATA OUT
Valid MSB
Figure 9. EOC and DATA OUT Voltage Waveforms
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
15
TLV2543C, TLV2543I
12-BIT ANALOG-TO-DIGITAL CONVERTERS
WITH SERIAL CONTROL AND 11 ANALOG INPUTS
SLAS096C – MARCH 1995 – REVISED JUNE 2000
PARAMETER MEASUREMENT INFORMATION
CS
(see Note A)
I/O
CLOCK
1
2
3
4
5
6
Access Cycle B
7
8
11
12
Sample Cycle B
ÎÎÎÎÎÎ
ÎÎÎÎÎÎ
1
Hi-Z State
DATA
OUT
A11
A10
A9
A8
A7
A6
A5
A4
A1
A0
Previous Conversion Data
ÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎ
ÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎ
MSB
B11
ÎÎÎÎ
ÎÎÎÎ
LSB
DATA
INPUT
B7
B6
B5
B4
MSB
B3
B2
B1
C7
B0
LSB
EOC
t(conv)
Shift in New Multiplexer Address,
Simultaneously Shift Out Previous
Conversion Value
A/D Conversion
Interval
Initialize
Initialize
Figure 10. Timing for 12-Clock Transfer Using CS With MSB First
CS
(see Note A)
I/O
CLOCK
1
2
3
4
5
6
Access Cycle B
DATA
OUT
A11
A10
A9
7
8
11
1
Sample Cycle B
A8
A7
A6
A5
A4
A1
ÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎ
ÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎ
Previous Conversion Data
MSB
12
A0
Low Level
ÎÎÎÎ
ÎÎÎÎ
LSB
DATA
INPUT
B7
B6
MSB
B5
B4
B3
B2
B1
B11
C7
B0
LSB
EOC
Shift in New Multiplexer Address,
Simultaneously Shift Out Previous
Conversion Value
Initialize
t(conv)
A/D Conversion
Interval
Initialize
Figure 11. Timing for 12-Clock Transfer Not Using CS With MSB First
NOTE A: To minimize errors caused by noise at CS, the internal circuitry waits for a setup time after CS↓ before responding to control input signals.
Therefore, no attempt should be made to clock in an address until the minimum CS setup time has elapsed.
16
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
TLV2543C, TLV2543I
12-BIT ANALOG-TO-DIGITAL CONVERTERS
WITH SERIAL CONTROL AND 11 ANALOG INPUTS
SLAS096C – MARCH 1995 – REVISED JUNE 2000
PARAMETER MEASUREMENT INFORMATION
CS
(see Note A)
1
I/O CLOCK
2
3
4
5
Access Cycle B
A7
DATA OUT
A6
A5
7
8
Sample Cycle B
A4
A3
A2
A1
Previous Conversion Data
ÎÎÎÎÎÎ
ÎÎÎÎÎÎ
Hi-Z
A0
1
B7
ÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎ ÎÎÎÎÎ
ÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎ ÎÎÎÎÎ
MSB
DATA INPUT
6
B7
B6
B5
B4
MSB
B3
LSB
B2
B1
B0
C7
LSB
EOC
t(conv)
Shift in New Multiplexer Address,
Simultaneously Shift Out Previous
Conversion Value
A/D Conversion
Interval
Initialize
Initialize
Figure 12. Timing for 8-Clock Transfer Using CS With MSB First
CS
(see Note A)
1
I/O CLOCK
2
3
4
5
Access Cycle B
DATA OUT
A7
A6
A5
7
8
1
Sample Cycle B
A4
A3
A2
A1
Previous Conversion Data
A0
Low Level
ÎÎÎÎÎÎÎÎÎÎÎ ÎÎÎÎÎ
ÎÎÎÎÎÎÎÎÎÎÎ ÎÎÎÎÎ
MSB
DATA INPUT
6
B7
MSB
B6
B5
B4
B3
ÎÎÎÎÎ
ÎÎÎÎÎ
LSB
B2
B1
B7
C7
B0
LSB
EOC
Shift in New Multiplexer Address,
Simultaneously Shift Out Previous
Conversion Value
Initialize
t(conv)
A/D Conversion
Interval
Initialize
Figure 13. Timing for 8-Clock Transfer Not Using CS With MSB First
NOTE A: To minimize errors caused by noise at CS, the internal circuitry waits for a setup time after CS↓ before responding to control
input signals. Therefore, no attempt should be made to clock in an address until the minimum CS setup time has elapsed.
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
17
TLV2543C, TLV2543I
12-BIT ANALOG-TO-DIGITAL CONVERTERS
WITH SERIAL CONTROL AND 11 ANALOG INPUTS
SLAS096C – MARCH 1995 – REVISED JUNE 2000
PARAMETER MEASUREMENT INFORMATION
CS
(see Note A)
I/O
CLOCK
1
2
3
4
5
6
Access Cycle B
7
8
15
16
Sample Cycle B
ÎÎÎÎÎÎ
ÎÎÎÎÎÎ
1
Hi-Z State
DATA
OUT
A15
A14
A13
A12
A10
A9
A8
A1
A0
ÎÎÎÎÎÎÎÎ Î ÎÎÎÎÎÎÎÎ
ÎÎÎÎÎÎÎÎ Î ÎÎÎÎÎÎÎÎ
Previous Conversion Data
MSB
DATA
INPUT
A11
B7
B6
B5
B3
B4
MSB
B2
B1
B15
ÎÎÎ
ÎÎ
LSB
B0
C7
LSB
EOC
t(conv)
Shift in New Multiplexer Address,
Simultaneously Shift Out Previous
Conversion Value
A/D Conversion
Interval
Initialize
Initialize
Figure 14. Timing for 16-Clock Transfer Using CS With MSB First
CS
(see Note A)
I/O
CLOCK
1
2
3
4
5
6
Access Cycle B
DATA
OUT
A15
A14
A13
8
15
A12
A11
A10
A9
A8
A1
ÎÎÎÎÎÎÎÎÎÎÎ ÎÎÎÎÎÎ
ÎÎÎÎÎÎÎÎÎÎÎ ÎÎÎÎÎÎ
B7
MSB
B6
B5
16
1
Sample Cycle B
Previous Conversion Data
MSB
DATA
INPUT
7
B3
B4
B2
B1
A0
Low Level
B15
ÎÎÎÎÎ
ÎÎÎÎÎ
LSB
B0
C7
LSB
EOC
Shift in New Multiplexer Address,
Simultaneously Shift Out Previous
Conversion Value
Initialize
t(conv)
A/D Conversion
Interval
Figure 15. Timing for 16-Clock Transfer Not Using CS With MSB First
NOTE A: To minimize errors caused by noise at CS, the internal circuitry waits for a setup time after CS↓ before responding to control input signals.
Therefore, no attempt should be made to clock in an address until the minimum CS setup time has elapsed.
18
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
TLV2543C, TLV2543I
12-BIT ANALOG-TO-DIGITAL CONVERTERS
WITH SERIAL CONTROL AND 11 ANALOG INPUTS
SLAS096C – MARCH 1995 – REVISED JUNE 2000
APPLICATION INFORMATION
4095
111111111111
VFS
See Notes A and B
4094
111111111110
VFSnom
4093
VFT = VFS – 1/2 LSB
2049
100000000001
2048
100000000000
VZT = VZS + 1/2 LSB
Step
Digital Output Code
111111111101
2047
011111111111
VZS
000000000001
1
000000000000
0
0.0008
0.0016
1.6376
1.6384
3.2752
1.6392
3.2756
2
0.0004
000000000010
3.2760
0
3.2768
VI – Analog Input Voltage – V
NOTES: A. This curve is based on the assumption that Vref+ and Vref – have been adjusted so that the voltage at the transition from digital 0
to 1 (VZT) is 0.0004 V and the transition to full scale (VFT) is 3.2756 V. 1 LSB = 0.8 mV.
B. The full-scale value (VFS) is the step whose nominal midstep value has the highest absolute value. The zero-scale value (VZS) is
the step whose nominal midstep value equals zero.
Figure 16. Ideal Conversion Characteristics
TLV2543
1
2
3
4
5
Analog
Inputs
6
7
8
9
11
12
15
AIN0
CS
AIN1
I/O CLOCK
AIN2
DATA INPUT
18
17
Processor
AIN3
AIN4
DATA OUT
AIN5
EOC
Control
Circuit
16
19
AIN6
AIN7
AIN8
REF+
AIN9
AIN10
REF–
14
3-V DC Regulated
13
GND
10
To Source
Ground
Figure 17. Serial Interface
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
19
TLV2543C, TLV2543I
12-BIT ANALOG-TO-DIGITAL CONVERTERS
WITH SERIAL CONTROL AND 11 ANALOG INPUTS
SLAS096C – MARCH 1995 – REVISED JUNE 2000
APPLICATIONS INFORMATION
simplified analog input analysis
Using the equivalent circuit in Figure 18, the time required to charge the analog input capacitance from 0 to VS
within 1/2 LSB can be derived as follows:
ǒ
Ǔ
The capacitance charging voltage is given by
V
C
+ VS 1–e– tcńRtCi
Where:
(1)
Rt = Rs + ri
The final voltage to 1/2 LSB is given by
VC (1/2 LSB) = VS – (VS /8192)
(2)
ǒ
Ǔ
Equating equation 1 to equation 2 and solving for time tc gives
V
and
S
ǒ
Ǔ
* VSń58192 + VS 1–e– tcńRtCi
(3)
tc (1/2 LSB) = Rt × Ci × ln(8192)
(4)
Therefore, with the values given the time for the analog input signal to settle is
tc (1/2 LSB) = (Rs + 1 kΩ) × 60 pF × ln(8192)
(5)
This time must be less than the converter sample time shown in the timing diagrams.
Driving Source†
TLV2543
Rs
VS
VI
ri
VC
1 kΩ MAX
Ci
50 pF MAX
VI = Input Voltage at AIN
VS = External Driving Source Voltage
Rs = Source Resistance
ri = Input Resistance
Ci = Input Capacitance
† Driving source requirements:
• Noise and distortion for the source must be equivalent to the
resolution of the converter.
• Rs must be real at the input frequency.
Figure 18. Equivalent Input Circuit Including the Driving Source
20
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
TLV2543C, TLV2543I
12-BIT ANALOG-TO-DIGITAL CONVERTERS
WITH SERIAL CONTROL AND 11 ANALOG INPUTS
SLAS096C – MARCH 1995 – REVISED JUNE 2000
MECHANICAL DATA
DB (R-PDSO-G**)
PLASTIC SMALL-OUTLINE PACKAGE
28 PIN SHOWN
0,38
0,22
0,65
28
0,15 M
15
0,15 NOM
8,20
7,40
5,60
5,00
Gage Plane
1
14
0,25
A
0°– 8°
1,03
0,63
Seating Plane
2,00 MAX
0,10
0,05 MIN
PINS **
14
16
20
24
28
30
38
A MAX
6,50
6,50
7,50
8,50
10,50
10,50
12,90
A MIN
5,90
5,90
6,90
7,90
9,90
9,90
12,30
DIM
4040065 / B 10/94
NOTES: A.
B.
C.
D.
All linear dimensions are in millimeters.
This drawing is subject to change without notice.
Body dimensions do not include mold flash or protrusion not to exceed 0,15.
Falls within JEDEC MO-150
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
21
TLV2543C, TLV2543I
12-BIT ANALOG-TO-DIGITAL CONVERTERS
WITH SERIAL CONTROL AND 11 ANALOG INPUTS
SLAS096C – MARCH 1995 – REVISED JUNE 2000
MECHANICAL DATA
DW (R-PDSO-G**)
PLASTIC SMALL-OUTLINE PACKAGE
16 PIN SHOWN
PINS **
0.050 (1,27)
16
20
24
28
A MAX
0.410
(10,41)
0.510
(12,95)
0.610
(15,49)
0.710
(18,03)
A MIN
0.400
(10,16)
0.500
(12,70)
0.600
(15,24)
0.700
(17,78)
DIM
0.020 (0,51)
0.014 (0,35)
16
0.010 (0,25) M
9
0.419 (10,65)
0.400 (10,15)
0.299 (7,59)
0.293 (7,45)
0.010 (0,25) NOM
Gage Plane
0.010 (0,25)
1
8
0°– 8°
A
0.050 (1,27)
0.016 (0,40)
Seating Plane
0.104 (2,65) MAX
0.012 (0,30)
0.004 (0,10)
0.004 (0,10)
4040000 / B 10/94
NOTES: A.
B.
C.
D.
22
All linear dimensions are in inches (millimeters).
This drawing is subject to change without notice.
Body dimensions do not include mold flash or protrusion not to exceed 0.006 (0,15).
Falls within JEDEC MS-013
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
TLV2543C, TLV2543I
12-BIT ANALOG-TO-DIGITAL CONVERTERS
WITH SERIAL CONTROL AND 11 ANALOG INPUTS
SLAS096C – MARCH 1995 – REVISED JUNE 2000
MECHANICAL DATA
N (R-PDIP-T**)
PLASTIC DUAL-IN-LINE PACKAGE
16 PIN SHOWN
A
16
PINS **
9
0.260 (6,60)
0.240 (6,10)
1
14
16
18
20
A MAX
0.775
(19,69)
0.775
(19,69)
0.920
(23.37)
0.975
(24,77)
A MIN
0.745
(18,92)
0.745
(18,92)
0.850
(21.59)
0.940
(23,88)
DIM
8
0.070 (1,78) MAX
0.035 (0,89) MAX
0.310 (7,87)
0.290 (7,37)
0.020 (0,51) MIN
0.200 (5,08) MAX
Seating Plane
0.125 (3,18) MIN
0.100 (2,54)
0.021 (0,53)
0.015 (0,38)
0°– 15°
0.010 (0,25) M
0.010 (0,25) NOM
14 Pin Only
4040049 / C 7/95
NOTES: A. All linear dimensions are in inches (millimeters).
B. This drawing is subject to change without notice.
C. Falls within JEDEC MS-001 (20-pin package is shorter than MS-001)
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
23
PACKAGE OPTION ADDENDUM
www.ti.com
8-Jan-2007
PACKAGING INFORMATION
Orderable Device
Status (1)
Package
Type
Package
Drawing
Pins Package Eco Plan (2)
Qty
TLV2543CDB
ACTIVE
SSOP
DB
20
70
Green (RoHS &
no Sb/Br)
CU NIPDAU
Level-1-260C-UNLIM
TLV2543CDBG4
ACTIVE
SSOP
DB
20
70
Green (RoHS &
no Sb/Br)
CU NIPDAU
Level-1-260C-UNLIM
TLV2543CDBR
ACTIVE
SSOP
DB
20
2000 Green (RoHS &
no Sb/Br)
CU NIPDAU
Level-1-260C-UNLIM
TLV2543CDBRG4
ACTIVE
SSOP
DB
20
2000 Green (RoHS &
no Sb/Br)
CU NIPDAU
Level-1-260C-UNLIM
TLV2543CDW
ACTIVE
SOIC
DW
20
25
Green (RoHS &
no Sb/Br)
CU NIPDAU
Level-1-260C-UNLIM
TLV2543CDWG4
ACTIVE
SOIC
DW
20
25
Green (RoHS &
no Sb/Br)
CU NIPDAU
Level-1-260C-UNLIM
TLV2543CDWR
ACTIVE
SOIC
DW
20
2000 Green (RoHS &
no Sb/Br)
CU NIPDAU
Level-1-260C-UNLIM
TLV2543CDWRG4
ACTIVE
SOIC
DW
20
2000 Green (RoHS &
no Sb/Br)
CU NIPDAU
Level-1-260C-UNLIM
TLV2543CN
ACTIVE
PDIP
N
20
20
Pb-Free
(RoHS)
CU NIPDAU
N / A for Pkg Type
TLV2543CNE4
ACTIVE
PDIP
N
20
20
Pb-Free
(RoHS)
CU NIPDAU
N / A for Pkg Type
TLV2543IDB
ACTIVE
SSOP
DB
20
70
Green (RoHS &
no Sb/Br)
CU NIPDAU
Level-1-260C-UNLIM
TLV2543IDBG4
ACTIVE
SSOP
DB
20
70
Green (RoHS &
no Sb/Br)
CU NIPDAU
Level-1-260C-UNLIM
TLV2543IDBR
ACTIVE
SSOP
DB
20
2000 Green (RoHS &
no Sb/Br)
CU NIPDAU
Level-1-260C-UNLIM
TLV2543IDBRG4
ACTIVE
SSOP
DB
20
2000 Green (RoHS &
no Sb/Br)
CU NIPDAU
Level-1-260C-UNLIM
TLV2543IDW
ACTIVE
SOIC
DW
20
25
Green (RoHS &
no Sb/Br)
CU NIPDAU
Level-1-260C-UNLIM
TLV2543IDWG4
ACTIVE
SOIC
DW
20
25
Green (RoHS &
no Sb/Br)
CU NIPDAU
Level-1-260C-UNLIM
TLV2543IDWR
ACTIVE
SOIC
DW
20
2000 Green (RoHS &
no Sb/Br)
CU NIPDAU
Level-1-260C-UNLIM
TLV2543IDWRG4
ACTIVE
SOIC
DW
20
2000 Green (RoHS &
no Sb/Br)
CU NIPDAU
Level-1-260C-UNLIM
TLV2543IN
ACTIVE
PDIP
N
20
20
Pb-Free
(RoHS)
CU NIPDAU
N / A for Pkg Type
TLV2543INE4
ACTIVE
PDIP
N
20
20
Pb-Free
(RoHS)
CU NIPDAU
N / A for Pkg Type
Lead/Ball Finish
MSL Peak Temp (3)
(1)
The marketing status values are defined as follows:
ACTIVE: Product device recommended for new designs.
LIFEBUY: TI has announced that the device will be discontinued, and a lifetime-buy period is in effect.
NRND: Not recommended for new designs. Device is in production to support existing customers, but TI does not recommend using this part in
a new design.
PREVIEW: Device has been announced but is not in production. Samples may or may not be available.
OBSOLETE: TI has discontinued the production of the device.
(2)
Eco Plan - The planned eco-friendly classification: Pb-Free (RoHS), Pb-Free (RoHS Exempt), or Green (RoHS & no Sb/Br) - please check
http://www.ti.com/productcontent for the latest availability information and additional product content details.
Addendum-Page 1
PACKAGE OPTION ADDENDUM
www.ti.com
8-Jan-2007
TBD: The Pb-Free/Green conversion plan has not been defined.
Pb-Free (RoHS): TI's terms "Lead-Free" or "Pb-Free" mean semiconductor products that are compatible with the current RoHS requirements
for all 6 substances, including the requirement that lead not exceed 0.1% by weight in homogeneous materials. Where designed to be soldered
at high temperatures, TI Pb-Free products are suitable for use in specified lead-free processes.
Pb-Free (RoHS Exempt): This component has a RoHS exemption for either 1) lead-based flip-chip solder bumps used between the die and
package, or 2) lead-based die adhesive used between the die and leadframe. The component is otherwise considered Pb-Free (RoHS
compatible) as defined above.
Green (RoHS & no Sb/Br): TI defines "Green" to mean Pb-Free (RoHS compatible), and free of Bromine (Br) and Antimony (Sb) based flame
retardants (Br or Sb do not exceed 0.1% by weight in homogeneous material)
(3)
MSL, Peak Temp. -- The Moisture Sensitivity Level rating according to the JEDEC industry standard classifications, and peak solder
temperature.
Important Information and Disclaimer:The information provided on this page represents TI's knowledge and belief as of the date that it is
provided. TI bases its knowledge and belief on information provided by third parties, and makes no representation or warranty as to the
accuracy of such information. Efforts are underway to better integrate information from third parties. TI has taken and continues to take
reasonable steps to provide representative and accurate information but may not have conducted destructive testing or chemical analysis on
incoming materials and chemicals. TI and TI suppliers consider certain information to be proprietary, and thus CAS numbers and other limited
information may not be available for release.
In no event shall TI's liability arising out of such information exceed the total purchase price of the TI part(s) at issue in this document sold by TI
to Customer on an annual basis.
Addendum-Page 2
PACKAGE MATERIALS INFORMATION
www.ti.com
9-Apr-2009
TAPE AND REEL INFORMATION
*All dimensions are nominal
Device
Package Package Pins
Type Drawing
SPQ
Reel
Reel
Diameter Width
(mm) W1 (mm)
A0 (mm)
B0 (mm)
K0 (mm)
P1
(mm)
W
Pin1
(mm) Quadrant
TLV2543CDBR
SSOP
DB
20
2000
330.0
16.4
8.2
7.5
2.5
12.0
16.0
Q1
TLV2543IDBR
SSOP
DB
20
2000
330.0
16.4
8.2
7.5
2.5
12.0
16.0
Q1
Pack Materials-Page 1
PACKAGE MATERIALS INFORMATION
www.ti.com
9-Apr-2009
*All dimensions are nominal
Device
Package Type
Package Drawing
Pins
SPQ
Length (mm)
Width (mm)
Height (mm)
TLV2543CDBR
SSOP
DB
20
2000
346.0
346.0
33.0
TLV2543IDBR
SSOP
DB
20
2000
346.0
346.0
33.0
Pack Materials-Page 2
IMPORTANT NOTICE
Texas Instruments Incorporated and its subsidiaries (TI) reserve the right to make corrections, modifications, enhancements, improvements,
and other changes to its products and services at any time and to discontinue any product or service without notice. Customers should
obtain the latest relevant information before placing orders and should verify that such information is current and complete. All products are
sold subject to TI’s terms and conditions of sale supplied at the time of order acknowledgment.
TI warrants performance of its hardware products to the specifications applicable at the time of sale in accordance with TI’s standard
warranty. Testing and other quality control techniques are used to the extent TI deems necessary to support this warranty. Except where
mandated by government requirements, testing of all parameters of each product is not necessarily performed.
TI assumes no liability for applications assistance or customer product design. Customers are responsible for their products and
applications using TI components. To minimize the risks associated with customer products and applications, customers should provide
adequate design and operating safeguards.
TI does not warrant or represent that any license, either express or implied, is granted under any TI patent right, copyright, mask work right,
or other TI intellectual property right relating to any combination, machine, or process in which TI products or services are used. Information
published by TI regarding third-party products or services does not constitute a license from TI to use such products or services or a
warranty or endorsement thereof. Use of such information may require a license from a third party under the patents or other intellectual
property of the third party, or a license from TI under the patents or other intellectual property of TI.
Reproduction of TI information in TI data books or data sheets is permissible only if reproduction is without alteration and is accompanied
by all associated warranties, conditions, limitations, and notices. Reproduction of this information with alteration is an unfair and deceptive
business practice. TI is not responsible or liable for such altered documentation. Information of third parties may be subject to additional
restrictions.
Resale of TI products or services with statements different from or beyond the parameters stated by TI for that product or service voids all
express and any implied warranties for the associated TI product or service and is an unfair and deceptive business practice. TI is not
responsible or liable for any such statements.
TI products are not authorized for use in safety-critical applications (such as life support) where a failure of the TI product would reasonably
be expected to cause severe personal injury or death, unless officers of the parties have executed an agreement specifically governing
such use. Buyers represent that they have all necessary expertise in the safety and regulatory ramifications of their applications, and
acknowledge and agree that they are solely responsible for all legal, regulatory and safety-related requirements concerning their products
and any use of TI products in such safety-critical applications, notwithstanding any applications-related information or support that may be
provided by TI. Further, Buyers must fully indemnify TI and its representatives against any damages arising out of the use of TI products in
such safety-critical applications.
TI products are neither designed nor intended for use in military/aerospace applications or environments unless the TI products are
specifically designated by TI as military-grade or "enhanced plastic." Only products designated by TI as military-grade meet military
specifications. Buyers acknowledge and agree that any such use of TI products which TI has not designated as military-grade is solely at
the Buyer's risk, and that they are solely responsible for compliance with all legal and regulatory requirements in connection with such use.
TI products are neither designed nor intended for use in automotive applications or environments unless the specific TI products are
designated by TI as compliant with ISO/TS 16949 requirements. Buyers acknowledge and agree that, if they use any non-designated
products in automotive applications, TI will not be responsible for any failure to meet such requirements.
Following are URLs where you can obtain information on other Texas Instruments products and application solutions:
Products
Amplifiers
Data Converters
DLP® Products
DSP
Clocks and Timers
Interface
Logic
Power Mgmt
Microcontrollers
RFID
RF/IF and ZigBee® Solutions
amplifier.ti.com
dataconverter.ti.com
www.dlp.com
dsp.ti.com
www.ti.com/clocks
interface.ti.com
logic.ti.com
power.ti.com
microcontroller.ti.com
www.ti-rfid.com
www.ti.com/lprf
Applications
Audio
Automotive
Broadband
Digital Control
Medical
Military
Optical Networking
Security
Telephony
Video & Imaging
Wireless
www.ti.com/audio
www.ti.com/automotive
www.ti.com/broadband
www.ti.com/digitalcontrol
www.ti.com/medical
www.ti.com/military
www.ti.com/opticalnetwork
www.ti.com/security
www.ti.com/telephony
www.ti.com/video
www.ti.com/wireless
Mailing Address: Texas Instruments, Post Office Box 655303, Dallas, Texas 75265
Copyright © 2009, Texas Instruments Incorporated