AIMTEC AM15E

Series AM15E-IZ
15 Watt | DC-DC Converter
FEATURES:
Models
Single output
Model
AM15E-1203SIZ
AM15E-1205SIZ
AM15E-1212SIZ
AM15E-1215SIZ
AM15E-2403SIZ
AM15E-2405SIZ
AM15E-2412SIZ
AM15E-2415SIZ
AM15E-4803SIZ
AM15E-4805SIZ
AM15E-4812SIZ
AM15E-4815SIZ
AM15E-1203SH30IZ
AM15E-1205SH30IZ
AM15E-1212SH30IZ
AM15E-1215SH30IZ
AM15E-2403SH30IZ
AM15E-2405SH30IZ
AM15E-2412SH30IZ
AM15E-2415SH30IZ
AM15E-4803SH30IZ
AM15E-4805SH30IZ
AM15E-4812SH30IZ
AM15E-4815SH30IZ
Models
Dual output
Model
AM15E-1205DIZ
AM15E-1212DIZ
AM15E-1215DIZ
AM15E-2405DIZ
AM15E-2412DIZ
AM15E-2415DIZ
AM15E-4805DIZ
AM15E-4812DIZ
AM15E-4815DIZ
AM15E-1205DH30IZ
AM15E-1212DH30IZ
AM15E-1215DH30IZ
www.aimtec.com
F 051e R12.C
•
•
•
•
•
RoHS compliant
2:1 input range
Low ripple and noise
•
•
•
•
Remote On/Off control
Synchronous rectifier
Power modules for PCB mounting
Regulated output
Operating temperature range: -40 to +85ºC
Capacitive loading up to 41000 µF (36-75V input)
Input
Voltage
(V)
Output
Voltage
(V)
Output Current
max (A)
Ripple & Noise
typ
Isolation
(VDC)
Efficiency
(%)
3.3
5
12
15
3.3
5
12
15
3.3
5
12
15
4
3
1.25
1
4
3
1.25
1
4
3
1.25
1
80mV p-p
80mV p-p
120mVp-p
150mVp-p
80mV p-p
80mV p-p
120mVp-p
150mVp-p
80mV p-p
80mV p-p
120mVp-p
150mVp-p
1500
1500
1500
1500
1500
1500
1500
1500
1500
1500
1500
1500
79
83
85
85
81
83
88
87
81
83
88
87
9-18
9-18
9-18
9-18
18-36
18-36
18-36
18-36
36-75
36-75
36-75
36-75
3.3
5
12
15
3.3
5
12
15
3.3
5
12
15
4
3
1.25
1
4
3
1.25
1
4
3
1.25
1
80mV p-p
80mV p-p
120mVp-p
150mVp-p
80mV p-p
80mV p-p
120mVp-p
150mVp-p
80mV p-p
80mV p-p
120mVp-p
150mVp-p
3000
3000
3000
3000
3000
3000
3000
3000
3000
3000
3000
3000
74
78
82
83
75
77
84
83
75
76
85
85
Input
Voltage
(V)
Output
Voltage
(V)
Output Current
max (A)
Ripple & Noise
typ
Isolation
(VDC)
Efficiency
(%)
±5
±12
±15
±5
±12
±15
±5
±12
±15
±1.5
±0.62
±0.5
±1.5
±0.62
±0.5
±1.5
±0.62
±0.5
50mVp-p
120mVp-p
150mVp-p
50mVp-p
120mVp-p
150mVp-p
50mVp-p
120mVp-p
150mVp-p
1500
1500
1500
1500
1500
1500
1500
1500
1500
85
85
85
83
88
87
83
88
87
±5
±12
±15
±1.5
±0.62
±0.5
50mVp-p
120mVp-p
150mVp-p
3000
3000
3000
78
82
9-18
9-18
9-18
9-18
18-36
18-36
18-36
18-36
36-75
36-75
36-75
36-75
9-18
9-18
9-18
18-36
18-36
18-36
36-75
36-75
36-75
9-18
9-18
9-18
Tel: +1 514 620 2722
1 of 5
81
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AM15E-IZ
Models
Dual output (continued)
Model
AM15E-2405DH30IZ
AM15E-2412DH30IZ
AM15E-2415DH30IZ
AM15E-4805DH30IZ
AM15E-4812DH30IZ
AM15E-4815DH30IZ
Input
Voltage
(V)
18-36
18-36
18-36
36-75
36-75
36-75
15 Watt | DC-DC Converter
Output
Voltage
(V)
±5
±12
±15
±5
±12
±15
Output Current
max (A)
Ripple & Noise
typ
Isolation
(VDC)
Efficiency
(%)
±1.5
±0.62
±0.5
±1.5
±0.62
±0.5
50mVp-p
120mVp-p
150mVp-p
50mVp-p
120mVp-p
150mVp-p
3000
3000
3000
3000
3000
3000
80
82
84
76
83
85
NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at rated output load
unless otherwise specified.
Input Specifications
Parameters
Voltage range
Filter
Remote On/Off Control
Absolute Maximum Rating
Permissible absolute maximum duration
Recommended Input Fuse (slow blow)
Isolation Specifications
Parameters
Tested I/O voltage
Resistance
Capacitance
Output Specifications
Parameters
Voltage accuracy
Short Circuit protection
Short Circuit restart
Over voltage protection
Over load protection
Line voltage regulation (Single)
Line voltage regulation (Dual)
Load voltage regulation (Single)
Load voltage regulation (Dual)
Temperature coefficient
Transient response recovery time
www.aimtec.com
F 051e R12.C
Nominal
12
24
48
On
Off
12 Vin
24 Vin
48 Vin
12 Vin
24 Vin
48 Vin
Conditions
3 sec
Conditions
HL-LL
HL-LL
25-100%
25-100%
25% load step
change
Typical
9-18
18-36
37-75
Maximum
Units
VDC
π (Pi) Network
3.5 to 12VDC or open circuit
0 to 1.2VDC or short circuit between pin 2 and 4; typical idle current 3mA
25
50
VDC
100
2
h
4A/250V
2A/250V
1A/250V
Typical
Maximum
Typical
Maximum
1500 & 3000
> 1000
1000
±2
Continuous
Auto recovery
Zener diode clamp protection
Over 110% full load with auto-recovery
±0.5
±0.5
±0.5
±2
±0.05
300
Tel: +1 514 620 2722
2 of 5
Units
VDC
MOhm
pF
Units
%
%
%
%
%
%/oC
uS
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AM15E-IZ
15 Watt | DC-DC Converter
General Specifications
Parameters
Switching frequency
Operating temperature
Storage temperature
Maximum Case temperature
Cooling
Humidity
Case material
Weight
Dimensions (L x W x H)
MTBF
Conditions
Typical
100% load
With derating above +75
Maximum
200
-40 to+75
-55 to +115
Free air convection
Units
KHz
o
C
o
C
o
C
95
95
Nickel coated copper
33
2.00 x 1.00 x 0.40 inches 50.80 x 25.40 x 10.50 mm
> 800 000 hrs (MIL-HDBK -217F, Ground Benign, t=+25oC)
%
g
Safety Specifications
Parameters
Agency approvals
Standards
CE
EN 55022, EN 55024 class B
Pin Out Specifications
Pin
Single
1
2
3
4
5
6
Dual
On/Off Control
-V Input
+V Input
-V Output
No pin
+V Output
On/Off Control
-V Input
+V Input
-V Output
Common
+V Output
Derating
1500 vdc Isolation
3000VDC Isolation
Free Air Convection
Free Air Convection
75 ºC
80
80
60
Output Power (%)
100
Output Power (%)
100
Safe Operating Area
40
20
Safe Operating Area
60
40
20
0
- 40
50º C
- 20
0
20
40
60
80
85
0
100
- 40
- 20
Ambient Temperature º C
www.aimtec.com
F 051e R12.C
0
20
40
60
80
85
100
Ambient Temperature º C
Tel: +1 514 620 2722
3 of 5
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AM15E-IZ
15 Watt | DC-DC Converter
Dimensions
1
10.16
(0.40)
Bottom View
5
4
20.32
(0.80)
15.24
(0.60)
2.54
(0.10)
2
10.16
(0.40)
3
7.62 5.08
(0.30) (0.20)
25.40
(1.00)
10.16
(0.40)
6
15.24
(0.60)
Notes:
All dimensions are typical
in millimeters (inches).
Tolerance ±0.25 (±0.01)
6.00
(0.24)
10.50
(0.41)
DIA
1.00
(0.04)
2.54
(0.10)
50.80
(2.00)
Block diagram
www.aimtec.com
F 051e R12.C
Tel: +1 514 620 2722
4 of 5
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AM15E-IZ
15 Watt | DC-DC Converter
Control ON/OFF pin connection example:
Single Output
Dual Output
The converter output can be disabled by moving SW to position “a”. When SW is in position “b”, the converter operates normally.
The SW can be replaced by a NPN transistor with connection as follows:
Note: The control voltage is referenced to negative input (-Vi )
Digital Control Circuit:
NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled
by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based on the
date manufactured. 3. Mechanical drawings and specifications are for reference only. 4. All specifications are measured at an ambient temperature of 25°C, humidity<75%,
nominal input voltage and at rated output load unless otherwise specified. 5. Aimtec may not have conducted destructive testing or chemical analysis on all internal components
and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for release. 6. This
product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications which necessitate
specific safety and regulatory standards other the ones listed in this datasheet. 7. Warranty is in accordance with Aimtec’s standard Terms of Sale available at www.aimtec.com.
www.aimtec.com
F 051e R12.C
Tel: +1 514 620 2722
5 of 5
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only