Series AMEC40-MAZ 40 Watt | AC-DC Converter FEATURES: Connectors on input/output Operating temperature: -40°C to +85°C Over load, Over voltage, Short circuit protection Universal Input: 90-260VAC, 47-440Hz, or 120-370VDC Energy star compliant 4000VAC I/O isolation Low ripple and noise CE, cULus, CB approvals CB Models Single output Model AMEC40-3.3SMAZ AMEC40-5SMAZ AMEC40-12SMAZ AMEC40-15SMAZ AMEC40-24SMAZ Input Voltage (VAC/Hz) Input Voltage (VDC) 90-264/47-440 90-264/47-440 90-264/47-440 90-264/47-440 90-264/47-440 120-370 120-370 120-370 120-370 120-370 Input Voltage (VAC/Hz) Input Voltage (VDC) Output Voltage (V) Output Current max (A) 3.3 5 12 15 24 8 8 3.33 2.66 1.66 Efficiency (%) 78 82 84 83 82 Models Dual output Model Output Voltage (V) Output Current max (A) Efficiency (%) AMEC40-5DMAZ 90-264/47-440 120-370 ±5 ±4 80 AMEC40-12DMAZ 90-264/47-440 120-370 ±12 ±1.66 85 AMEC40-15DMAZ 90-264/47-440 120-370 ±15 ±1.33 82 AMEC40-24DMAZ 90-260/47-440 120-370 ±24 ±0.835 77 NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at rated output load unless otherwise specified. Input Specifications Parameters Conditions Typical Maximum 115 VAC 230 VAC 115 VAC 230 VAC 3.15 <0.5 <0.8 117 1000 530 25 50 150 Conditions Typical Maximum (LL-HL) 0-100% load single 0-100% load dual 25% load - 1st out, 100% load – 2nd out Depending of the model 25% load Step 20MHz bandwidth 115VAC ±2 ±0.5 ±1 ±2 ±5 470-23 000 ±2 50 29 0 Current Inrush current <2ms Leakage current External fuse Input dissipation Recommended slow blow type No load; 115VAC No load; 264VAC Start-up time Units mA A µA A W ms Output Specifications Parameters Voltage accuracy Line regulation Load regulation Cross regulation Maximum Capacitive load Transient response deviation Ripple & Noise* Hold-up time (min) Minimum Load Current Units % % % % µF % of Vout mV p-p ms % of Max *Ripple & Noise measured with 0.1μF M/C and 1μF E/C www.aimtec.com F 052e R7.B Tel: +1 514 620 2722 1 of 4 Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AMEC40-MAZ 40 Watt | AC-DC Converter Isolation Specifications Parameters Tested I/O voltage Input FG Output FG Isolation Resistance Conditions Typical 3 sec 3 sec 3 sec 4000 1500 1500 >1000 Maximum Units VAC VAC VAC MΩ General Specifications Parameters Conditions Switching frequency Over current protection Over voltage protection Short circuit protection Short Circuit restart Operating temperature Maximum case temperature Storage temperature Temperature coefficient Cooling Humidity Case material Weight Dimensions (L X H X W) MTBF Typical 47 110 Zener diode clamp Hiccup mode, indefinite Auto recovery -40 - +85 Auto recovery With derating above 50ºC Maximum Units 140 110 KHz % % o 100 -40 to +95 0.02 Free air convection Non condensing 95 C C o C % / oC o % RH Metal 270 4.92 x 2.56 x 1.38 inches 125 x 65 x 35mm > 800 000 hrs (MIL-HDBK -217F, t=+25oC) g Environment Approval Test Shock Vibration Parameters Wave form Acceleration amplitude Bump duration Converter operation Number of bumps Test mode Displacement Acceleration Converter operation Conditions Half sine wave 5gn 30 ms Before and after test, body mounted (on chassis) 18 (3 in each direction for every axis) Sweep sine, 10-100Hz, speed 0.05Hz/s 1 mm 3g, 3 loops 30min one cycle, 3h total, every axis tested Before and after test, body mounted (on chassis) Safety Specifications Parameters Agency approvals Standards www.aimtec.com F 052e R7.B cULus, CE, CB Scheme EMI - Conducted and radiated emission Medical Electrical Equipment Harmonic Current Emissions Voltage fluctuations and flicker Electrostatic Discharge Immunity RF, Electromagnetic Field Immunity Electrical Fast Transient/Burst Immunity Surge Immunity RF, Conducted Disturbance Immunity Power frequency Magnetic Field Immunity Voltage dips, Short Interruptions Immunity EN55011, class B EN 60601-1, CSA-C22.2 No. 601.1-M90 IEC/EN 61000-3-2, (EN60555-2) IEC/EN 61000-3-3, (EN60555-3) IEC 61000-4-2 IEC 61000-4-3 IEC 61000-4-4 IEC 61000-4-5 IEC 61000-4-6 IEC 61000-4-8 IEC 61000-4-11 Tel: +1 514 620 2722 2 of 4 Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AMEC40-MAZ 40 Watt | AC-DC Converter Pin Out Specifications Pin Single Dual 1 2 3 4 5 6 AC Input (L) AC Input (N) +V Output -V Output N.C. N.C. AC Input (L) AC Input (N) +V Output Common Common -V Output N.C.: Not Connected Dimensions www.aimtec.com F 052e R7.B Tel: +1 514 620 2722 3 of 4 Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AMEC40-MAZ 40 Watt | AC-DC Converter Derating Free Air Convection 50º C Output Power (%) 100 80 Safe Operating Area 60 40 20 0 - 40 - 20 0 20 40 60 80 85 100 Ambient Temperature º C NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based on the date manufactured. 3. Mechanical drawings and specifications are for reference only. 4. All specifications are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at rated output load unless otherwise specified.5..Aimtec may not have conducted destructive testing or chemical analysis on all internal components and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for release. 5. This product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications which necessitate specific safety and regulatory standards other the ones listed in this datasheet. www.aimtec.com F 052e R7.B Tel: +1 514 620 2722 4 of 4 Toll free: + 1 888 9 AIMTEC (924 6832) North America only