AIMTEC AM30KW

Series AM30KW-IZ
30 Watt | DC-DC Converter
FEATURES:
• Ultra-Wide 4:1 Input
• Continuous Short Circuit Protection
• Remote On/Off control
Models
Single output
Model
AM30KW-2403SIZ
AM30KW-2405SIZ
AM30KW-2412SIZ
AM30KW-2415SIZ
AM30KW-2424SIZ
AM30KW-4803SIZ
AM30KW-4805SIZ
AM30KW-4812SIZ
AM30KW-4815SIZ
AM30KW-4824SIZ
AM30KW-2403SH30IZ
AM30KW-2405SH30IZ
AM30KW-2412SH30IZ
AM30KW-2415SH30IZ
AM30KW-2424SH30IZ
AM30KW-4803SH30IZ
AM30KW-4805SH30IZ
AM30KW-4812SH30IZ
AM30KW-4815SH30IZ
AM30KW-4824SH30IZ
Models
Dual output
Model
AM30KW-2405DIZ
AM30KW-2412DIZ
AM30KW-2415DIZ
AM30KW-4805DIZ
AM30KW-4812DIZ
AM30KW-4815DIZ
AM30KW-2405DH30IZ
AM30KW-2412DH30IZ
AM30KW-2415DH30IZ
AM30KW-4805DH30IZ
AM30KW-4812DH30IZ
AM30KW-4815DH30IZ
•
•
•
Standard package 2”x1.6”
High efficiency up to 85%
RoHS compliant
Input Voltage
(V)
Output Voltage
(V)
Output Current
max (A)
Isolation
(VDC)
Efficiency
(%)
9-36
9-36
9-36
9-36
9-36
18-75
18-75
18-75
18-75
18-75
3.3
5
12
15
24
3.3
5
12
15
24
5.4
6
2.5
2
1.25
5.4
6
2.5
2
1.25
3000
3000
3000
3000
3000
3000
3000
3000
3000
3000
78
81
84
82
82
78
80
83
83
83
Input Voltage
(V)
Output Voltage
(V)
Output Current
max (mA)
Isolation
(VDC)
Efficiency
(%)
9-36
9-36
9-36
18-75
18-75
18-75
±5
±12
±15
±5
±12
±15
±3
±1.25
±1
±3
±1.25
±1
3000
3000
3000
3000
3000
3000
81
82
83
83
85
85
9-36
9-36
9-36
9-36
9-36
18-75
18-75
18-75
18-75
18-75
9-36
9-36
9-36
18-75
18-75
18-75
3.3
5
12
15
24
3.3
5
12
15
24
±5
±12
±15
±5
±12
±15
5.4
6
2.5
2
1.25
5.4
6
2.5
2
1.25
±3
±1.25
±1
±3
±1.25
±1
1500
1500
1500
1500
1500
1500
1500
1500
1500
1500
1500
1500
1500
1500
1500
1500
78
81
84
82
82
78
80
83
83
83
81
82
83
83
85
85
NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at
rated output load unless otherwise specified.
www.aimtec.com
F 051e R12
Tel: +1 514 620 2722
1 of 5
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AM30KW-IZ
30 Watt | DC-DC Converter
Input Specifications
Parameters
Voltage range
Filter
Start up time
Recommended input fuse (Slow
Blow)
Absolute Maximum Rating
Peak Input Voltage time
On/Off control
No Load Input Current
Isolation Specifications
Parameters
Tested I/O voltage
Resistance
Output Specifications
Parameters
Voltage accuracy
Over voltage Protection
Over current protection
Short Circuit protection
Short circuit restart
Line voltage regulation
Load voltage regulation (Single)
Load voltage regulation (Dual)
Temperature coefficient
Ripple & Noise
Voltage adjustment range
Minimum Load Current
General Specifications
Parameters
Switching frequency
Operating temperature
Storage temperature
Maximum case temperature
Cooling
Humidity
Case material
Weight
Dimensions (L x W x H)
MTBF
Maximum soldering temperature
Transient recovery time
Transient recovery deviation
Nominal
Typical
24
48
Maximum
9-36
18-75
π (Pi) Network
24
48
24
48
Units
VDC
ms
4A/250V
2A/250V
50
100
VDC
ON –TTL High or Open ; OFF – TTL Low or Short
Conditions
Typical
3 sec
500VDC
Maximum
1500 & 3000
>1000
Conditions
Typical
±2
>110
HL-LL
25-100%
25-100%
Conditions
Units
VDC
MOhm
Maximum
Units
%
250
-55 to +105
%
Continuous
Auto Recovery
Typical
100% load
With derating above 70ºC
% of Vin
%
%
%/oC
mV p-p
%
% of Max
Maximum
Units
KHz
o
C
o
C
o
C
-40 to +85
Free Air Convection
100
95
Nickel coated copper with non-conductive base
50
2.00 x 1.60 x 0.40 inches 50.80 x 40.60 x 10.20 mm
> 550 000 hrs (MIL-HDBK -217F, Ground Benign, t=+25oC)
25% step change
280
mA
Zener diode clamp
±0.5
±0.5
±1
±0.05
150
±10
25
20MHz Bandwidth
ms
% RH
g
o
C
uS
mS
Safety Specifications
Parameters
Agency approvals
Standards
www.aimtec.com
F 051e R12
CE
EN 55022, EN 55024 class A
Tel: +1 514 620 2722
2 of 5
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AM30KW-IZ
30 Watt | DC-DC Converter
Pin Out Specifications
Pin
1
2
3
4
5
6
7
Single
+V Input
-V Input
On/OFF Control
No pin
+V Output
-V Output
Trim
Dual
+V Input
-V Input
On/OFF Control
+V Output
Common
-V Output
Trim
Dimensions
5.10
(0.20)
50.80
(2.00)
2
5
Bottom View
3
45.72
(1.80)
10.16
(0.40)
www.aimtec.com
F 051e R12
Dimensions mm (inch)
Case Tolerance ±0.50 (±0.02)
Pin Pitch Tolerance ±0.35 (±0.014)
5.60
(0.22)
Ø 1.00
(0.04)
6
7
Printed Face
2.54
(0.10)
10.16 10.16 10.16
(0.40) (0.40) (0.40)
1
5.10
(0.20)
40.60
(1.60)
7.62 10.16 5.08
(0.30) (0.40) (0.20)
17.78
(0.70)
4
Tel: +1 514 620 2722
3 of 5
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AM30KW-IZ
30 Watt | DC-DC Converter
Trimming
Derating
1500VDC Isolation
D
400 LFM
85 ºC
C
200 LFM
80 ºC
B
100 LFM
75 ºC
A
Free Air
70 ºC
3000VDC Isolation
A
B
C
100
Output Power (%)
Output Power (%)
40º C
D
100
80
Safe Operating Area
60
40
80
Safe Operating Area
60
40
20
20
0
- 40
Free Air Convection
- 20
0
20
40
60
80
85
0
100
- 40
- 20
F 051e R12
20
40
60
80
85
100
Ambient Temperature º C
Ambient Temperature º C
www.aimtec.com
0
Tel: +1 514 620 2722
4 of 5
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AM30KW-IZ
30 Watt | DC-DC Converter
Control ON/OFF pin connection example
Single Output
Dual Output
Digital Control Circuit:
Vpeak
Control
Voltage
On / Off Control
0.5mA
NPN
0V
Ra =
Vpeak – 0.6
DC/DC
Converter
-V input
0.5mA
NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled
by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based on the
date manufactured. 3. Mechanical drawings and specifications are for reference only. 4. All specifications are measured at an ambient temperature of 25°C, humidity<75%,
nominal input voltage and at rated output load unless otherwise specified. 5.Aimtec may not have conducted destructive testing or chemical analysis on all internal components
and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for release. 6. This
product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications which necessitate
specific safety and regulatory standards other the ones listed in this datasheet. 7. Warranty is in accordance with Aimtec’s standard Terms of Sale available at www.aimtec.com.
www.aimtec.com
F 051e R12
Tel: +1 514 620 2722
5 of 5
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only