AIMTEC AMEPR10D

Series AMEPR10D-AZ
up to 0.7A | AC-DC / DC-DC LED driver
FEATURES:
AC-DC or DC-DC Constant current LED Driver
Input range 90-264VAC/47-440Hz
High Efficiency up to 82%
Operating temperature -20 to 80°C
The THD < 20%
•
•
•
•
•
Models
Single output
Model
AMEPR10D-5020AZ+Suffix ②
AMEPR10D-4025AZ+Suffix ②
AMEPR10D-3630AZ+Suffix ②
AMEPR10D-3035AZ+Suffix ②
AMEPR10D-1564AZ+Suffix ②
AMEPR10D-1270AZ+Suffix ②
①
Max
Output
Power
(W) ①
10
10
10.8
10.5
9.6
8.4
Output
Voltage
Range (V)
36-50
30-40
24-36
15-30
8-15
8-12
No Load
Output
Voltage
(V max.)
Output
Current
(A)
62
62
52
34
23
23
0.2
0.25
0.3
0.35
0.64
0.7
•
•
•
•
•
Over Temperature Protection
IP20 and IP67 Case
Active PFC with TRIAC dimmable②
SCP, Over Load Protection
Leading or Trailing Edge Triac
Input Voltage
(VAC/Hz)
Input
Voltage
(VDC)
Efficiency
(%)
90-264/47-440
90-264/47-440
90-264/47-440
90-264/47-440
90-264/47-440
90-264/47-440
120-370
120-370
120-370
120-370
120-370
120-370
82
82
81
81
80
79
Exceeding the maximum output power will permanently damage the converter
Model Nomenclature for Ordering:
Add Suffix “-UD”
Add Suffix “-UW”
Add Suffix “-110D”
Add Suffix “-110W”
Add Suffix “-220D”
Add Suffix “-220W”
②
Universal AC input 90-264VAC(no TRIAC dimming with this option),IP20
Universal AC input 90-264VAC(no TRIAC dimming with this option),IP67
AC input 90-135VAC, IP20
AC input 90-135VAC, IP67
AC input 180-264VAC, IP20
AC input 180-264VAC, IP67
NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at
rated output load unless otherwise specified.
Input Specifications
Parameters
Inrush current <2ms
Leakage current
AC current
Power Factor
External fuse (slow blow)
Start up time
Output Specifications
Parameters
Conditions
115VAC
230VAC
115VAC
230VAC
115VAC
230VAC
115VAC
230VAC
Typical
8
15
0.2
0.25
0.23
0.1
200
Conditions
Typical
Current accuracy
±5
Line regulation
LL-HL
±7
Load regulation
0-100% load
±5
20MHz Bandwidth
1
Ripple & Noise ③
Hold-up time
1
Minimum Load Voltage
See the models table
③ Tested with 0.1µF (M/C) or (C/C) and 47µF (E/C) parallel capacitors at the end.
www.aimtec.com
F 052.1e R3.F
Tel: +1 514 620 2722
1 of 4
Maximum
Units
A
mA
A
0.9
0.9
250V/1A
Maximum
ms
Units
%
%
%
V p-p
ms
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AMEPR10D-AZ
up to 0.7A | AC-DC / DC-DC LED driver
Isolation Specifications
Parameters
Conditions
Tested I/O voltage
Isolation Resistance
General Specifications
Parameters
Switching frequency
Over load protection
Over voltage protection
Short circuit protection
Short circuit restart
Over temperature protection
Operating temperature
Maximum case temperature
Storage temperature
Temperature coefficient
Cooling
Humidity
Case material
Wires
Environment Approval
Vibration
Parameters
Wave form
Acceleration amplitude
Bump duration
Converter operation
Number of bumps
Test mode
Displacement
Acceleration
Converter operation
Maximum
Units
3000
Typical
65
110% of Iout
110% of Vout
Continuous
Auto recovery
>105°C
-20 to +80
With derating over 55°C
Dimensions (L X H X W)
MTBF
Shock
>1000
Conditions
Weight
Test
Typical
3sec
-40 to +95
±0.02
Free air convection
Plastic
UL1015 20AWG * 10CM
IP20
120
IP67
240
133 x 33 x 30mm (5.24 x 1.30 x 1.18 inch)
>400,000 hrs (MIL-HDBK-217F at +25°C)
VAC
MΩ
Maximum
Units
KHz
o
100
95
C
C
o
C
% / oC
o
% RH
g
Conditions
Half sine wave
5gn
30 ms
Before and after test, body mounted (on chassis)
18 (3 in each direction for every axis)
Sweep sine, 10-100Hz, speed 0.05Hz/s
1 mm
3g, 3 loops 30min one cycle, 3h total, every axis tested
Before and after test, body mounted (on chassis)
Safety Specifications
Parameters
Agency approvals
Standards
Standards
www.aimtec.com
F 052.1e R3.F
cULus, CE, FCC
EN61347-1, EN61347-2-13, IEC62384, UL8750, UL60950-1, EN55015, EN55024
Radiated and Conducted Emission
FCC Part 15 Subpart B, Class B, ANSI C63.4 :2003
EMI - Conducted and radiated emission
EN 55022
Harmonic Current Emissions
IEC/EN 61000-3-2, (EN60555-2)
Voltage fluctuations and flicker
IEC/EN 61000-3-3, (EN60555-3)
Electrostatic Discharge Immunity
IEC 61000-4-2
RF, Electromagnetic Field Immunity
IEC 61000-4-3
Electrical Fast Transient/Burst Immunity
IEC 61000-4-4
Surge Immunity
IEC 61000-4-5
RF, Conducted Disturbance Immunity
IEC 61000-4-6
Power frequency Magnetic Field Immunity
IEC 61000-4-8
Voltage dips, Short Interruptions Immunity
IEC 61000-4-11
Tel: +1 514 620 2722
2 of 4
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AMEPR10D-AZ
up to 0.7A | AC-DC / DC-DC LED driver
Dimensions
Temperature Graph
Free Air Convection
55 º C
Output Power %
100
80
Safe Operating Area
60
40
20
0
- 25
- 20
20
40
60
Ambient Temperature
www.aimtec.com
F 052.1e R3.F
0
80
ºC
100
Tel: +1 514 620 2722
3 of 4
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AMEPR10D-AZ
up to 0.7A | AC-DC / DC-DC LED driver
Triac Dimming Feature
Triac Device
LED Lighting
Application
LED Driver
AC
Line (Brown)
Aimtec
Neutral (Blue)
Red (+)
Black (-)
Earth
Ground
Triac Dimming Notes:
A- The triac device can be installed on either Line or Neutral
B- Aimtec LED drivers have been designed to function with a wide
range of available Triac devices, however the following list of Triac
devices have been tested and are recommended by Aimtec.
1) Company: LUTRON
Series: SKYLARK
Model: SF-10P-WH (input voltage: 120Vac)
Model: SF-12P-277-WH (input voltage 277Vac)
2) Company LUTRON
Series: DIVA
Model: DVF-103P-WH (input voltage: 120Vac)
Model: DVF-103P-277-WH (input voltage: 277Vac)
3) Company BERKER
Model: 2867 10 (input voltage:230Vac)
If the power voltage range is 90~135Vac, triac suggested use model
SF-10P-WH or DVF-103P-WH.
If the power voltage range is 180~260Vac, triac suggested use
model SF-12P-277-WH or DVF-103P-277-WH.
NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled
by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based on the
date manufactured. 3. Mechanical drawings and specifications are for reference only. 4. All specifications are measured at an ambient temperature of 25°C, humidity<75%,
nominal input voltage and at rated output load unless otherwise specified.5..Aimtec may not have conducted destructive testing or chemical analysis on all internal components
and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for release. 5. This
product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications which necessitate
specific safety and regulatory standards other the ones listed in this datasheet.
www.aimtec.com