Series AMEL20-MAZ 20 Watt | AC-DC / DC-DC Converter FEATURES: • I/O Isolation 4000VAC • Operating Temp: -40 oC to +70 oC • Over load, Over Voltage, Short Circuit Protection • Up to 82% efficiency • • Energy Star compliant Ultra small package CB Models Single output Input Voltage (VAC/Hz) Input Voltage (VDC) Max Output wattage (W) 90-264/47-440 90-264/47-440 90-264/47-440 90-264/47-440 90-264/47-440 120-370 120-370 120-370 120-370 120-370 13.2 20 20 20 20 Input Voltage (VAC/Hz) Input Voltage (VDC) Max Output wattage (W) Output Voltage (V) AMEL20-3.35DMAZ AMEL20-3.312DMAZ AMEL20-3.315DMAZ AMEL20-3.324DMAZ AMEL20-512DMAZ AMEL20-515DMAZ AMEL20-524DMAZ AMEL20-1215DMAZ AMEL20-1224DMAZ AMEL20-1524DMAZ 90-264/47-440 90-264/47-440 90-264/47-440 90-264/47-440 90-264/47-440 90-264/47-440 90-264/47-440 90-264/47-440 90-264/47-440 90-264/47-440 120-370 120-370 120-370 120-370 120-370 120-370 120-370 120-370 120-370 120-370 17.5 18 18 18 18 18 18 18 18 18 3.3/5 3.3/12 3.3/15 3.3/24 5/12 5/15 5/24 12/15 12/24 15/24 1.4/2.5 1.4/1.1 1.4/0.89 1.4/0.55 1.6/0. 83 1.6/0.66 1.6/0.46 0.66/0.66 0.58/0. 42 0.54/0. 42 AMEL20-3.3N5DMAZ AMEL20-3.3N12DMAZ AMEL20-3.3N15DMAZ AMEL20-5N5DMAZ AMEL20-5N12DMAZ AMEL20-5N15DMAZ AMEL20-12N12DMAZ AMEL20-12N15DMAZ 90-264/47-440 90-264/47-440 90-264/47-440 90-264/47-440 90-264/47-440 90-264/47-440 90-264/47-440 90-264/47-440 120-370 120-370 120-370 120-370 120-370 120-370 120-370 120-370 14.8 18 18 14 18 18 18 18 -3.3/5 -3.3/12 -3.3/15 -5/5 -5/12 -5/15 -12/12 -12/15 -0.7/2.5 -1.4/1.1 -1.4/0.89 -0.8/2 -1.6/0. 83 -1.6/0.66 -0.66/0.83 -0.66/0.66 Model AMEL20-3.3SMAZ AMEL20-5SMAZ AMEL20-12SMAZ AMEL20-15SMAZ AMEL20-24SMAZ Output Voltage(V) 3.3 5 12 15 24 Models Asymmetric Dual output Model *Output power must not exceed the listed values. Output Current max (A) 4 4 1.66 1.33 0.84 Rated Output Current (A) Maximum capacitive load (µF) Efficiency (%) 5600 4700 3300 2200 1000 74 78 82 82 82 Maximum capacitive load (µF) Efficiency (%) 1000 1000 1000 1000 680 680 680 560 560 560 75 78 77 76 76 78 76 77 79 80 680 680 680 680 470 470 470 330 75 76 76 75 75 75 77 76 NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at rated output load unless otherwise specified. Input Specifications Parameters Current Inrush current <2ms (cold start) Leakage current External fuse www.aimtec.com F 052e R8.M Conditions Typical 115VAC 230VAC 115VAC 230VAC 0.46 0.29 slow blow type 1.5 Tel: +1 514 620 2722 1 of 4 Maximum 10 20 0.25 Units A A A A mA A Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AMEL20-MAZ 20 Watt | AC-DC / DC-DC Converter Input Specifications (continued) Parameters Input dissipation Start up time Output Specifications Parameters Voltage accuracy Line regulation Load regulation (single output) Load regulation (dual output) Transient recovery time Transient response deviation Ripple & Noise* Hold-up time (min) Conditions Typical Maximum Units Conditions Typical Maximum Units No Load <0.5 50 25% load step 3.3 & 5V models 12, 15 & 24V models 110VAC 230VAC ±2 ±1 ±2 ±3 500 ±2 75 100 10 25 Conditions Typical 0-100% load Unbalanced (0-100%) load *Ripple and Noise are measured at 20MHz bandwidth by using a 0.1μF (M/C) parallel capacitor. Isolation Specifications Parameters Tested I/O voltage Isolation resistance Isolation Capacitance General Specifications Parameters Switching frequency Over load protection Over voltage protection Short circuit protection Short circuit restart Operating temperature Maximum case temperature Storage temperature Temperature coefficient Cooling Humidity Case material Weight Dimensions (L x W x H) MTBF Environment Approval Test Shock Vibration 3 sec, 1.2mA >1000 2200 Conditions Typical 100% load Auto recovery, Foldback 65 150 Zener Diode Clamp Continuous Auto recovery -40 to +70 See derating table F 052e R8.M ms Rated Units Maximum Units 4000 VAC MΩ pF KHz % o 100 C C o C % / oC o % RH g Conditions Half sine wave 5gn 30 ms before and after test, body mounted (on chassis) 18 (3 in each direction for every axis) Sweep sine 1mm 3g 10-100Hz, speed 0.05Hz/s Converter operation www.aimtec.com % % % % µs % of Vout mV p-p -45 to +95 ±0.02 Free air convection Non condensing 20 ~ 95 Plastic resin + Fiberglass (flammability to UL 94V-0) 70 2.22 x 1.21 x 0.99 inches 56.48 x 30.86 x 25.10mm > 400 000 hrs (MIL-HDBK -217F, t=+25oC) Parameters Wave form Acceleration amplitude Bump duration Converter operation Number of bumps Test mode Displacement Acceleration W ms Tel: +1 514 620 2722 2 of 4 Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AMEL20-MAZ 20 Watt | AC-DC / DC-DC Converter Safety Specifications Parameters Agency approvals cULus, CE, CB, TÜV Rheinhald (cTUVus), Bauart-Mark IEC\EN\UL 60601-1, CSA-C22.2 No. 601.1-M90 Medical Electrical Equipment Information technology Equipment EN 60950-1:2006+A11:2009 EMI - Conducted and radiated emission EN55011, class B Harmonic Current Emissions IEC/EN 61000-3-2, (EN60555-2) Voltage fluctuations and flicker IEC/EN 61000-3-3, (EN60555-3) Electrostatic Discharge Immunity IEC 61000-4-2 RF, Electromagnetic Field Immunity IEC 61000-4-3 Electrical Fast Transient/Burst Immunity IEC 61000-4-4 Surge Immunity IEC 61000-4-5 RF, Conducted Disturbance Immunity IEC 61000-4-6 Power frequency Magnetic Field Immunity IEC 61000-4-8 Voltage dips, Short Interruptions Immunity IEC 61000-4-11 Information Technology Equipment UL 60950-1:2007 Information Technology Equipment CAN/CSA-C22.2 No.60950-1-07 Standards Pin Out Specifications Pin Single 1 2 3 4 5 AC Input (N) AC Input (L) +V Output -V Output No pin Dual positive AC Input (N) AC Input (L) +V1 Output Common +V2 Output Dual negative/positive AC Input (N) AC Input (L) +V1 Output Common -V2 Output Dimensions 3 Top View 4 5,27 (0.21) 2 5 5.37 (0.21) 1 10.20 (0.40) 1 10.20 (0.40) 45.72 (1.80) 20.40 (0.80) 30.86 (1.21) 5.27 (0.21) 56.46 (2.22) 2 5.37 (0.21) 3 Top View 4 5 25.10 (0.99) DIV: 10.00 (0.40) 8.00 (0.31) 5Ø 1.0 (Ø 0.04) Dimensions mm (inch) Case Tolerance ±0.50 (±0.02) Pin Diameter 1.0 ± 0.05 (0.04 ± 0.002) Pin Pitch Tolerance ±0.35 (±0.014) 1.05 (0.04) www.aimtec.com F 052e R8.M Tel: +1 514 620 2722 3 of 4 Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AMEL20-MAZ 20 Watt | AC-DC / DC-DC Converter Derating Free Air Convection 40°C Output Power (%) 100 80 60 Safe Operating Area 40 20 70°C 0 - 40 - 20 0 20 40 60 80 100 Ambient Temperature º C NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based on the date manufactured. 3. Mechanical drawings and specifications are for reference only. 4. All specifications are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at rated output load unless otherwise specified. 5. Aimtec may not have conducted destructive testing or chemical analysis on all internal components and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for release. 6. This product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications which necessitate specific safety and regulatory standards other the ones listed in this datasheet. 7. Warranty is in accordance with Aimtec’s standard Terms of Sale available at www.aimtec.com. www.aimtec.com F 052e R8.M Tel: +1 514 620 2722 4 of 4 Toll free: + 1 888 9 AIMTEC (924 6832) North America only