AIMTEC AMEL20

Series AMEL20-MAZ
20 Watt | AC-DC / DC-DC Converter
FEATURES:
• I/O Isolation 4000VAC
• Operating Temp: -40 oC to +70 oC
• Over load, Over Voltage, Short Circuit Protection
• Up to 82% efficiency
•
•
Energy Star compliant
Ultra small package
CB
Models
Single output
Input Voltage
(VAC/Hz)
Input
Voltage
(VDC)
Max Output
wattage (W)
90-264/47-440
90-264/47-440
90-264/47-440
90-264/47-440
90-264/47-440
120-370
120-370
120-370
120-370
120-370
13.2
20
20
20
20
Input Voltage
(VAC/Hz)
Input
Voltage
(VDC)
Max Output
wattage (W)
Output
Voltage
(V)
AMEL20-3.35DMAZ
AMEL20-3.312DMAZ
AMEL20-3.315DMAZ
AMEL20-3.324DMAZ
AMEL20-512DMAZ
AMEL20-515DMAZ
AMEL20-524DMAZ
AMEL20-1215DMAZ
AMEL20-1224DMAZ
AMEL20-1524DMAZ
90-264/47-440
90-264/47-440
90-264/47-440
90-264/47-440
90-264/47-440
90-264/47-440
90-264/47-440
90-264/47-440
90-264/47-440
90-264/47-440
120-370
120-370
120-370
120-370
120-370
120-370
120-370
120-370
120-370
120-370
17.5
18
18
18
18
18
18
18
18
18
3.3/5
3.3/12
3.3/15
3.3/24
5/12
5/15
5/24
12/15
12/24
15/24
1.4/2.5
1.4/1.1
1.4/0.89
1.4/0.55
1.6/0. 83
1.6/0.66
1.6/0.46
0.66/0.66
0.58/0. 42
0.54/0. 42
AMEL20-3.3N5DMAZ
AMEL20-3.3N12DMAZ
AMEL20-3.3N15DMAZ
AMEL20-5N5DMAZ
AMEL20-5N12DMAZ
AMEL20-5N15DMAZ
AMEL20-12N12DMAZ
AMEL20-12N15DMAZ
90-264/47-440
90-264/47-440
90-264/47-440
90-264/47-440
90-264/47-440
90-264/47-440
90-264/47-440
90-264/47-440
120-370
120-370
120-370
120-370
120-370
120-370
120-370
120-370
14.8
18
18
14
18
18
18
18
-3.3/5
-3.3/12
-3.3/15
-5/5
-5/12
-5/15
-12/12
-12/15
-0.7/2.5
-1.4/1.1
-1.4/0.89
-0.8/2
-1.6/0. 83
-1.6/0.66
-0.66/0.83
-0.66/0.66
Model
AMEL20-3.3SMAZ
AMEL20-5SMAZ
AMEL20-12SMAZ
AMEL20-15SMAZ
AMEL20-24SMAZ
Output
Voltage(V)
3.3
5
12
15
24
Models
Asymmetric Dual output
Model
*Output power must not exceed the listed values.
Output
Current max
(A)
4
4
1.66
1.33
0.84
Rated
Output
Current (A)
Maximum
capacitive
load
(µF)
Efficiency
(%)
5600
4700
3300
2200
1000
74
78
82
82
82
Maximum
capacitive
load
(µF)
Efficiency
(%)
1000
1000
1000
1000
680
680
680
560
560
560
75
78
77
76
76
78
76
77
79
80
680
680
680
680
470
470
470
330
75
76
76
75
75
75
77
76
NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at
rated output load unless otherwise specified.
Input Specifications
Parameters
Current
Inrush current <2ms (cold start)
Leakage current
External fuse
www.aimtec.com
F 052e R8.M
Conditions
Typical
115VAC
230VAC
115VAC
230VAC
0.46
0.29
slow blow type
1.5
Tel: +1 514 620 2722
1 of 4
Maximum
10
20
0.25
Units
A
A
A
A
mA
A
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AMEL20-MAZ
20 Watt | AC-DC / DC-DC Converter
Input Specifications (continued)
Parameters
Input dissipation
Start up time
Output Specifications
Parameters
Voltage accuracy
Line regulation
Load regulation (single output)
Load regulation (dual output)
Transient recovery time
Transient response deviation
Ripple & Noise*
Hold-up time (min)
Conditions
Typical
Maximum
Units
Conditions
Typical
Maximum
Units
No Load
<0.5
50
25% load step
3.3 & 5V models
12, 15 & 24V models
110VAC
230VAC
±2
±1
±2
±3
500
±2
75
100
10
25
Conditions
Typical
0-100% load
Unbalanced (0-100%) load
*Ripple and Noise are measured at 20MHz bandwidth by using a 0.1μF (M/C) parallel capacitor.
Isolation Specifications
Parameters
Tested I/O voltage
Isolation resistance
Isolation Capacitance
General Specifications
Parameters
Switching frequency
Over load protection
Over voltage protection
Short circuit protection
Short circuit restart
Operating temperature
Maximum case temperature
Storage temperature
Temperature coefficient
Cooling
Humidity
Case material
Weight
Dimensions (L x W x H)
MTBF
Environment Approval
Test
Shock
Vibration
3 sec, 1.2mA
>1000
2200
Conditions
Typical
100% load
Auto recovery, Foldback
65
150
Zener Diode Clamp
Continuous
Auto recovery
-40 to +70
See derating table
F 052e R8.M
ms
Rated
Units
Maximum
Units
4000
VAC
MΩ
pF
KHz
%
o
100
C
C
o
C
% / oC
o
% RH
g
Conditions
Half sine wave
5gn
30 ms
before and after test, body mounted (on chassis)
18 (3 in each direction for every axis)
Sweep sine
1mm
3g
10-100Hz, speed 0.05Hz/s
Converter operation
www.aimtec.com
%
%
%
%
µs
% of Vout
mV p-p
-45 to +95
±0.02
Free air convection
Non condensing
20 ~ 95
Plastic resin + Fiberglass (flammability to UL 94V-0)
70
2.22 x 1.21 x 0.99 inches
56.48 x 30.86 x 25.10mm
> 400 000 hrs (MIL-HDBK -217F, t=+25oC)
Parameters
Wave form
Acceleration amplitude
Bump duration
Converter operation
Number of bumps
Test mode
Displacement
Acceleration
W
ms
Tel: +1 514 620 2722
2 of 4
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AMEL20-MAZ
20 Watt | AC-DC / DC-DC Converter
Safety Specifications
Parameters
Agency approvals
cULus, CE, CB, TÜV Rheinhald (cTUVus), Bauart-Mark
IEC\EN\UL 60601-1, CSA-C22.2 No. 601.1-M90
Medical Electrical Equipment
Information technology Equipment
EN 60950-1:2006+A11:2009
EMI - Conducted and radiated emission
EN55011, class B
Harmonic Current Emissions
IEC/EN 61000-3-2, (EN60555-2)
Voltage fluctuations and flicker
IEC/EN 61000-3-3, (EN60555-3)
Electrostatic Discharge Immunity
IEC 61000-4-2
RF, Electromagnetic Field Immunity
IEC 61000-4-3
Electrical Fast Transient/Burst Immunity
IEC 61000-4-4
Surge Immunity
IEC 61000-4-5
RF, Conducted Disturbance Immunity
IEC 61000-4-6
Power frequency Magnetic Field Immunity
IEC 61000-4-8
Voltage dips, Short Interruptions Immunity
IEC 61000-4-11
Information Technology Equipment
UL 60950-1:2007
Information Technology Equipment
CAN/CSA-C22.2 No.60950-1-07
Standards
Pin Out Specifications
Pin
Single
1
2
3
4
5
AC Input (N)
AC Input (L)
+V Output
-V Output
No pin
Dual positive
AC Input (N)
AC Input (L)
+V1 Output
Common
+V2 Output
Dual negative/positive
AC Input (N)
AC Input (L)
+V1 Output
Common
-V2 Output
Dimensions
3
Top View 4
5,27
(0.21)
2
5
5.37
(0.21)
1
10.20
(0.40)
1
10.20
(0.40)
45.72
(1.80)
20.40
(0.80)
30.86
(1.21)
5.27
(0.21)
56.46
(2.22)
2
5.37
(0.21)
3
Top View 4
5
25.10
(0.99)
DIV: 10.00 (0.40)
8.00
(0.31)
5Ø 1.0 (Ø 0.04)
Dimensions mm (inch)
Case Tolerance ±0.50 (±0.02)
Pin Diameter 1.0 ± 0.05 (0.04 ± 0.002)
Pin Pitch Tolerance ±0.35 (±0.014)
1.05
(0.04)
www.aimtec.com
F 052e R8.M
Tel: +1 514 620 2722
3 of 4
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AMEL20-MAZ
20 Watt | AC-DC / DC-DC Converter
Derating
Free Air Convection
40°C
Output Power (%)
100
80
60
Safe Operating Area
40
20
70°C
0
- 40
- 20
0
20
40
60
80
100
Ambient Temperature º C
NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer
controlled by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary
based on the date manufactured. 3. Mechanical drawings and specifications are for reference only. 4. All specifications are measured at an ambient temperature of 25°C,
humidity<75%, nominal input voltage and at rated output load unless otherwise specified. 5. Aimtec may not have conducted destructive testing or chemical analysis on all
internal components and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for
release. 6. This product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications
which necessitate specific safety and regulatory standards other the ones listed in this datasheet. 7. Warranty is in accordance with Aimtec’s standard Terms of Sale available
at www.aimtec.com.
www.aimtec.com
F 052e R8.M
Tel: +1 514 620 2722
4 of 4
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only