SLPOWER PENT1040B

PENT1040B
Universal 40 Watt (Pre-IEEE802.3at Compliant)
High Power PoE Gigabit Injector
•10/100/1000 (MbPS) Data Rates
•Self-contained Injector
•100-250VAC Universal Input
•Desktop Style / Non-vented Case
•Pre-IEEE802.3at Compliant Detection, Disconnect, and Over Voltage Control Function
•Load Diagnostic LED
•Over Load Shutdown and Short Circuit Protection
•Regulated Output With Low Ripple
•Complies with EMI/RFI Regulations
•CE Compliant
International Safety Standard Approvals
Specifications
Output Specifications
Combined Line and Load Voltage Regulation Excluding Cord
General Specifications
±1% Topology
Switching-Fixed Frequency Flyback
Dielectric Withstand Primary-Secondary
Secondary-Ground
3000VAC, 4250VDC 500VDC
Spacing 5mm Primary-Secondary
Leakage Current Less than 250 uA
Efficiency 75.1% min.
EMC Information
Emissions
Harmonic
VFF
ESD
RF EFI
EFT
Surge
CDI
CD
Voltage Dips
FCC Part 15. EN55022. EN61000-3-2 EN61000-3-3
EN61000-4-2.
EN61000-4-3.
EN61000-4-4.
EN61000-4-5.
EN61000-4-6.
EN61000-4-8.
EN61000-4-11
Class B
Class B
Level 2 Level 2 Level 2 Level 3 Level 2 Level 1 CE LVD, EMC, RoHS, WEEE, CE Compliant
Hold-up Time @120VAC
18ms min. typ.
Storage Temp -30° C to +85° C
Approvals and Standards
Safety cULus : UL/CSA60950
TUV : EN60950
CE: LVD, EMCD
MTBF Ripple
1% Vp-p max.
Transient Response
0.5ms for 50% Load Change Typical
Protection Foldback Overcurrent Protection,
Short Circuit Protection
Input Specifications
AC Input Voltage Range Line Frequency AC Input Current Protection
Environmental Specifications
100-250VAC -10%, +6%
47-63Hz
1.0A max. Internal Primary Current Fuse,
Inrush Limiting
Operating Temperature 0° C to 40° C No Derating,
Convectional Cooling Non Vented Case
Thermal Performance Relative Humidity Non-Condensing
5% to 95% Altitude 0-10,000 feet
100,000 Calculated Hours
SL Power Electronics Corp • 6050 King Drive • Ventura, CA 93003 • Phone:805.486.4565 • Fax:805.487.8911 • Email:[email protected] • www.slpower.com
PENT1040B
Universal 40 Watt (Pre-IEEE802.3at Compliant)
High Power PoE Gigabit Injector
Output Currents
Output
Voltage Min
Max
Ault Part Number
PENT1040B5600F01
For the most current data and application support visit www.slpower.com
56 V 0.00 A 0.71 A Ripple
Vp-p max.
40 W
560 mV
Ault Part Number Key
PENT
1
040
B
56
00
F
01
Product Family Name
Number of Outputs
Output Wattage
Configuration
Type
Output Voltage
Output Connector
Input
Configuration
Standard (no modifications
or special packaging)
Input Configuration
United
Kingdom
(G)
Max
Watts
Australian
IEC320Shaver
C8
(E)
w/ground
C14 (N)
(F)
IEC320
w/o ground
C18
(Q)
Pin Connections
N. America/
Japan
(B)
Europe
(M)
United
Kingdom
(G)
Australian
(E)
Shaver
C8
(N)
General Specifications (continued from p. 1)
Weight Case and Dimension 5.24L x 2.13W x 1.42H (in)
133.0L x 54.0W x 36.0H (mm)
Case Material Black 94V0
Polycarbonate
Cord and Connectors Personalized PoE
(excluding cord)
Options (additional costs may apply): • Custom label artwork • Custom agency approvals available • Surge protection (Input & Output) • Mounting bracket • Custom PoE modifications
7 Ounces, 200 Grams
Dual RJ45 jacks built into the enclosure
87654321
87654321
J2
(Power and Data Out)
J1
(Data In)
(Rear of Unit)
PoE Gigabit Pin-out Connections:
POWER (+)
Data
Pins 4/5 (Data + PWR) Data Pins 1/2 (Data Only)
Data Pins 3/6 (Data Only)
Data
Note: POWER (-)
Pins 7/8 (Data + PWR)
= Transformer
LED Functions:
Amber Power On
Power
over Ethernet Plus (known as PoEP and/or PoE+) IEEE802.3at:
Green Power Active
• Proposed standard is in development; decision expected in the next 4-6 months Blink
Load Error
• Operates on Cat5 and higher infrastructure
• Uses all four pairs of standard Ethernet Category 5 cable to provide up to 56 watts of power
• Backwards compatible with IEEE802.3af standard SL Power Electronics Corp • 6050 King Drive • Ventura, CA 93003 • Phone:805.486.4565 • Fax:805.487.8911 • Email:[email protected] • www.slpower.com
Data Sheet © 2008 SL Power Electronics Corp. The information and specifications contained in this data sheet are believed to be correct at time of publication. However, SL Power accepts no responsibility for consequences arising from reproduction errors or inaccuracies. Specifications are subject to change without notice.
Rev.9/3/08