28-1800 Vdc Kilovac EV250-1A & 1B - 400 Amps ("Czonka II EVX") Features: Make & Break Load Switching Note: Dimensions in inches. Multiply values by 25.4 for dimensions in mm. CONTACT RATINGS* 400A 1 0 0 ,0 0 0 9 0 0 0A M o m en t a ry C a rry R eg i o n 1 0 ,0 0 0 dc R eg i o n o f C on t a c t L e v it a ti on . O pe r at io n P ro h ib i te d dc dc 1 ,0 0 0 6 0 V 0V dc dc 90 c dc Vd 0V 00 1 0 0 27 0 18 L ife C y c le s 0V V 0V 28 12 40 Hydrogen dielectric for power switching high current loads 400 A carry, 2,500 A interrupt @ 320 Vdc Ideal for circuit protection, control, battery switching, and main power safety disconnect Versatile power, voltage, and current operating range: 28-1800Vdc tested Low-cost compact version for volume production applications. Requires external coil economizer (PWM or lower hold voltage) Patented "hammer effect" mechanism breaks light contact welds Patented "Super-sealed" environment chamber uniquely protects ALL moving parts Can operate in harsh environments Moving contact rotates to provide fresh contact surface for low contact resistance Features: and low power comsumption Sealed control connector. Mating connector with flying leads P/N 2005 available, see page 59 Logic control enabled by external economizer P/N 9913 High temperature (135oC) model with 10 inch flying leads available (-4A call factory for sales drawing) Bi-directional power switching Fast operate and release time 1 0 1 1 1 0 1 0 0 1 ,0 0 0 1 0 ,0 0 0 1 0 0 ,0 0 0 S w itc hin g C u r re n t * For circuit conditions and actual data refer to the EV250 hot switch study. Since each application is unique, user is encouraged to verify rating in actual application. Part Number PRODUCT SPECIFICATIONS UNIT EV250-1A COIL DATA*** EV250-1B EV250-1A EV250-1B Units Contact Arrangement .......................................................... SPST-NO SPST-NO Voltage* (nominal ) 12 24 Contact Form ........................................................................ X X Pickup (close), max. 8.3 16.6 Continuous Current Carry, Max. ........................................ A 400 400 6.5 Minutes .................................................................... Continuous Hold, max/min ** 5.1/3.8 A 500 500 Dropout (open), min. Break Current @ 320 Vdc ................................................... A 2,500 2,500 Contact Resistance, Max. ................................................... ohms 0.0003 0.0003 Contact Resistance, Typ. .................................................... ohms 0.0001 - 0.0002 0.0001 - 0.0002 Dielectric at Sea Level (leakage < 1mA) ............................ Vrms 2,200 2,200 Shock, 11 ms 1/2 Sine (peak), operating ......................... G's Peak 30 30 Vibration, Sinusoidal (80-2000 Hz, peak) ......................... G's 20 20 Operating Ambient Temperature Range ............................ Load Life, @320 Vdc, 95% Weibull* ................................. oC o -40 to +85 -40 to +85 cycles See Page 19 See Page 19 ms 30 30 Operate Time, 25oC .............................................................. Close (includes bounce) Typ. ...................................... Bounce (after close only), Max. .................................. Open (includes arcing), Max. ...................................... * Parameter ms 5 5 ms 15 15 Insulation Resistance @ 500 Vdc, Min. ............................ Mohm 100 100 Weight, Nominal .................................................................. pound (kg) 1.54 (0.7) 1.54 (0.7) Refer to Page 19 for actual mix of precharge and break currents used on each cycle. Vdc 10.2/7.6 0.88 - 3.3 2.4 - 6.6 Coil Resistance @ 25oC, +/- 10% 3 12 Ohms Coil Energy, max. 0.2 0.2 J Coil Clamping 3 x nom. 3 x nom. * Do not apply continously. Requires external coil economizer. Other special coil voltages available upon request. * * At maximum continuous current and maximum ambient temperature. Hold voltage must be maintained within the limits specified to keep contacts closed and to prevent coil overheating. * * * Do not use a free wheeling diode or capacitor across the coil. PART NUMBER SELECTION Sample Part No. EV250-1 Coil Voltage A = 12 Vdc, Nominal B = 24 Vdc, Nominal A For detailed specifications and recommendations, refer to the EV250-1A & B sales drawings. Tyco Electronics / www.tycoelectronics.com / Factory Direct Technical Support: 800-253-4560, ext. 2023 (U.S., Canada, Mexico) or 805-220-2020, ext. 2023 (International) 16 EV250 Contact Ratings Features: C UR RE NT vs T IM E C ON TA CT S C LOSED I NT O 7 0 % AN D 9 0% C A PAC IT OR PR E C HA R GE 7 50 7 00 6 50 6 00 5 50 5 00 4 50 4 00 3 50 3 00 2 50 Features: 2 00 1 50 1 00 50 0 0 1 2 3 4 5 6 7 8 L IF E R A T IN G S A N D Q U A L IF IC A T IO N T E S T P L A N Test # C u rre n t V o lta g e Load Type % P re C h a rg e S w itc h M o d e N o rm a l O p e ra tio n s 1 2 re fe re n c e g ra p h a n d te s t circ u it d ia g ra m (s h t. 8 ) C a p a c itive C a p a c itive 90% 70% m ake m ake o n ly o n ly A b n o rm a l O p e ra tio n s 3 -2 5 0 A 320 V R e s istiv e N /A m a k e / b re a k 4 2500 A 320 V R e s istiv e N /A b re a k o n ly S equence 1 0 K c y c le s 1 0 c yc le s 2 2 1 10K 10 2 2 10K 10 2 3 10K 10 2 2 4 10K 10 2 5 E tc . C o n tin u e C y c lin g to R e la y F a ilu re T h e te s tin g o b je c tiv e is to v e rify p ro p e r re la y fu n c tio n fo r a g ive n n u m b e r o f c o n se c u tiv e a n d cu m u la tiv e c yc le s u n d e r b o th n o rm a l a n d a b n o rm a l co n d itio n s in a v a rie ty o f lo a d s w itc h in g a p p lic a tio n s . T h e life ra tin g o f 4 0 K cy c le s m in im u m w a s c a lc u la te d w ith 9 5 % W e ib u ll re lia b ility . Electrical Data (Over Temperature Range - Max. Terminal Temp. = 200oC) Make/Break Life for Capacitive & Resistive Loads at 320 Vdc (1) (2) @ 90% capacitive pre-charge Cycles 50,000 @ 70% capacitive pre-charge Cycles 50 @ -250 A (2 consecutive, reverse polarity) (1) Cycles 10 @ 3300 A (break only, 2 consecutive) (1) Cycles 4 Cycles 100,000 Mechanical Life (1) Resistive load includes inductance L = 25 uH. Load @ 2500 A tested @ 200 uH. (2) Conductor: 2 each of Copper 54 mm2 (AWG 0) required for > 250 A carry. 1 Copper (AWG 0) conductor recommneded for ≤ 250 A (3) Life based on projected Weibull Life with 95% Reliability 19 CII Technologies / P.O. Box 4422 / Santa Barbara, CA 93140 / ph 805.684.4560 / fax 805.684.9679 / e-mail [email protected] / website www.ciitech.com