Ordering information Unit type PAA300F PAA PAA 300 1 2 F 3 -5 4 -O 5 1Series name 2Output wattage 3Universal input 4Output voltage 5Optional C :with Coating G :Low leakage current R :Positive logic control W :with Alarm signal R MODEL MAX OUTPUT WATTAGE[W] DC OUTPUT PAA300F-3 180 3V 60A PAA300F-5 300 5V 60A PAA300F-12 324 12V 27A PAA300F-15 330 15V 22A PAA300F-24 336 24V 14A PAA300F-48 336 48V 7A SPECIFICATIONS MODEL VOLTAGE[V] CURRENT[A] INPUT FREQUENCY[Hz] EFFICIENCY[%] ACIN 100V ACIN 200V ACIN 100V INRUSH CURRENT[A] ACIN 200V LEAKAGE CURRENT[mA] VOLTAGE[V] CURRENT[A] LINE REGULATION[mV] LOAD REGULATION[mV] 0 to +50C *1 RIPPLE[mVp-p] -10 - 0C *1 0 to +50C *1 RIPPLE NOISE[mVp-p] -10 - 0C *1 0 to +50C TEMPERATURE REGULATION[mV] -10 to +50C *2 DRIFT[mV] START-UP TIME[ms] HOLD-UP TIME[ms] OUTPUT VOLTAGE ADJUSTMENT RANGE[V] OVERCURRENT PROTECTION OVERVOLTAGE PROTECTION OPERATING INDICATION REMOTE SENSING REMOTE ON/OFF INPUT-OUTPUT-RC INPUT-FG OUTPUT-RC-FG OUTPUT-RC OPERATING TEMP.,HUMID.AND ALTITUDE STORAGE TEMP.,HUMID.AND ALTITUDE VIBRATION IMPACT AGENCY APPROVALS CONDUCTED NOISE HARMONIC ATTENUATOR CASE SIZE/WEIGHT COOLING METHOD POWER FACTOR OUTPUT PROTECTION CIRCUIT AND OTHERS ISOLATION ENVIRONMENT SAFETY AND NOISE REGULATIONS OTHERS ACIN 100V ACIN 200V PAA300F-3 PAA300F-5 PAA300F-12 PAA300F-15 PAA300F-24 PAA300F-48 AC85 - 264 1f or DC120 - 340 2.6typ 4.4typ 1.3typ 2.2typ 50/60 (47 - 63) 68typ 74typ 78typ 80typ 81typ 81typ 0.99typ (Io=100%) 0.95typ (Io=100%) 20typ (Io=100%) 40typ (Io=100%) 0.75max (60Hz, According to UL, CSA, VDE and DEN-AN) 3 5 12 15 24 48 60 60 27 22 14 7 20max 20max 48max 60max 96max 192max 40max 40max 100max 120max 150max 300max 80max 80max 120max 120max 120max 150max 140max 140max 160max 160max 160max 200max 120max 120max 150max 150max 150max 200max 160max 160max 180max 180max 180max 300max 40max 50max 120max 150max 240max 480max 50max 60max 150max 180max 290max 580max 12max 20max 48max 60max 96max 192max 500max (ACIN 85V, Io=100%) 20typ (Io=100%) 2.85 - 3.45 t10% Works over 105% of rating and recovers automatically 4.00 - 5.25V Works at 115 - 140% of rating LED (Green) Provided Provided AC3,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At Room Temperature) AC2,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At Room Temperature) AC500V 1minute, Cutoff current = 100mA, DC500V 50MW min (At Room Temperature) AC100V 1minute, Cutoff current = 100mA, DC100V 50MW min (At Room Temperature) -10 to +65C, 20 - 90%RH (Non condensing) (Refer to DERATING CURVE), 3,000m (10,000feet) max -20 to +75C, 20 - 90%RH (Non condensing), 9,000m (30,000feet) max 10 - 55Hz, 19.6m/s2 (2G), 3minutes period, 60minutes each along X, Y and Z axis 196.1m/s2 (20G), 11ms, once each X, Y and Z axis UL 1950, EN60950, VDE0160, CSA C22.2 No.234 Complies with DEN-AN and IEC60950 Complies with FCC-B, CISPR22-B, EN55022-B, VCCI-B Complies with IEC61000-3-2 120X92X190mm (without terminal block and screw) (WXHXD) /2.2kg max Forced cooling (internal fan) *1 According to 20MHz oscilloscope or Ripple-Noise meter(equivalent to KEISOKU-GIKEN : RM101). *2 Drift is change in DC output for an eight hour period after a half-hour warm-up at 25C, with the input voltage held constant at the rated input/output. * Avoid prolonged use under over-load. A-42