TOTAL-POWER PBA1500F-12

Ordering information
Unit type
PBA
PBA1500F
PBA 1500
1
2
F
3
-5
4
-O
5
1Series name
2Output wattage
3Universal input
4Output voltage
5Optional
C :with Coating
G :Low leakage current
U :Operation stop voltage
is set at a lower value
F1 :With Long-Life fan
F3 :Reverse air exhaust
type
F4 :Low speed fan
R
MODEL
MAX OUTPUT WATTAGE[W]
DC OUTPUT
PBA1500F-3R3
990
ACIN 100V 3.3V 300A
ACIN 200V *3 3.3V 300A
PBA1500F-5
1500
5V 300A
5V 300A
PBA1500F-7R5
1500
7.5V 200A
7.5V 200A
PBA1500F-12
1500
12V 125A
12V 125A
PBA1500F-15
1500
15V 100A
15V 100A
PBA1500F-24
1680
24V 65A
24V 70(105)A
PBA1500F-36
1692
36V 42A
36V 47(70)A
PBA1500F-48
1680
48V 32A
48V 35A
SPECIFICATIONS
MODEL
VOLTAGE[V]
CURRENT[A]
ACIN 100V
ACIN 200V
FREQUENCY[Hz]
INPUT
OUTPUT
PROTECTION
CIRCUIT AND
OTHERS
ISOLATION
ENVIRONMENT
SAFETY AND
NOISE
REGULATIONS
OTHERS
ACIN 100V
ACIN 200V
ACIN 100V
POWER FACTOR
ACIN 200V
ACIN 100V
INRUSH CURRENT[A]
ACIN 200V
LEAKAGE CURRENT[mA]
VOLTAGE[V]
ACIN 100V
CURRENT[A]
ACIN 200V *3
LINE REGULATION[mV]
LOAD REGULATION[mV]
0 to +50C *1
RIPPLE[mVp-p]
-20 - 0C *1
0 to +50C *1
RIPPLE NOISE[mVp-p]
-20 - 0C *1
0 to +50C *1
TEMPERATURE REGULATION[mV]
-20 to +50C *1
DRIFT[mV]
*2
START-UP TIME[ms]
HOLD-UP TIME[ms]
OUTPUT VOLTAGE ADJUSTMENT RANGE[V]
OUTPUT VOLTAGE SETTING[V]
OVERCURRENT PROTECTION
OVERVOLTAGE PROTECTION[V] *4
OPERATING INDICATION
REMOTE SENSING
REMOTE ON/OFF
INPUT-OUTPUT -RC
INPUT-FG
OUTPUT-RC-AUX-FG
OUTPUT-RC -AUX
OPERATING TEMP.,HUMID.AND ALTITUDE
STORAGE TEMP.,HUMID.AND ALTITUDE
VIBRATION
IMPACT
AGENCY APPROVALS
CONDUCTED NOISE
CE MARKING
HARMONIC ATTENUATOR
CASE SIZE/WEIGHT
COOLING METHOD
EFFICIENCY[%]
PBA1500F-3R3 PBA1500F-5 PBA1500F-7R5 PBA1500F-12 PBA1500F-15 PBA1500F-24 PBA1500F-36 PBA1500F-48
AC85 - 264 1f or DC120 - 370
15typ
19typ
8typ
10typ
50/60 (47 - 63)
72typ
77typ
81typ
81typ
83typ
84typ
84typ
84typ
75typ
81typ
83typ
84typ
86typ
87typ
87typ
87typ
0.98typ (Io=100%)
0.95typ (Io=100%)
20/40typ (Io=100%) (Primary inrush current /Secondary inrush current) (More than 10 sec. to re-start)
40/40typ (Io=100%) (Primary inrush current /Secondary inrush current) (More than 10 sec. to re-start)
0.9/1.5max (ACIN 100V/240V 60Hz, Io=100%, According to IEC60950-1)
3.3
5
7.5
12
15
24
36
48
300
300
200
125
100
65
42
32
300
300
200
125
100
70(105)
47(70)
35
20max
20max
36max
48max
60max
96max
144max
192max
40max
40max
60max
100max
120max
150max
150max
300max
80max
80max
120max
120max
120max
120max
150max
150max
140max
140max
160max
160max
160max
160max
160max
400max
120max
120max
150max
150max
150max
150max
200max
200max
160max
160max
180max
180max
180max
180max
240max
500max
40max
50max
75max
120max
150max
240max
360max
480max
60max
75max
120max
180max
180max
290max
440max
600max
12max
20max
30max
48max
60max
96max
144max
192max
600typ(ACIN 100/200V, Io=100%) Start-up time is 500ms typ for less than 1minute of applying input again from turning off the input voltage.
20typ (ACIN 100/200V, Io=100%)
2.64 - 3.96
3.96 - 6.00
5.25 - 8.25
8.25 - 13.20
10.50 - 16.50 16.50 - 26.40 25.20 - 39.60 38.40 - 56.00
3.30 - 3.40
5.00 - 5.15
7.50 - 7.80
12.00 - 12.48 15.00 - 15.60 24.00 - 24.96 36.00 - 37.44 48.00 - 49.92
Works over 105% of rated current or 101% of peak current and recovers automatically
Vo+0.66 - 1.32 Vo+1.0 - 2.0
Vo+1.5 - 3.0
Vo+2.4 - 4.8
Vo+3.0 - 6.0
Vo+4.8 - 9.6
Vo+7.2 - 14.4 Vo+4.8 - 12.0
LED (Green)
Provided
Provided
AC3,000V 1minute, Cutoff current = 25mA, DC500V 50MWmin (At Room Temperature)
AC2,000V 1minute, Cutoff current = 25mA, DC500V 50MWmin (At Room Temperature)
AC500V 1minute, Cutoff current = 100mA, DC500V 50MWmin (At Room Temperature)
AC100V 1minute, Cutoff current = 100mA, DC100V 50MWmin (At Room Temperature)
-20 to +71C, 20 - 90%RH (Non condensing) 3,000m (10,000feet) max
-20 to +75C, 20 - 90%RH (Non condensing) 3,000m (10,000feet) max
19.6m/s2 (2G), 10 - 55Hz, 3minutes period, 60minutes each along X, Y and Z axis
196.1m/s2 (20G), 11ms, once each X, Y and Z axis
UL60950-1, C-UL(CSA60950-1), EN60950-1, EN50178 Complies with DEN-AN (At only AC input)
Complies with FCC Part15 classB, VCCI-B, CISPR22-B, EN55011-B, EN55022-B, additional noise filter required for meeting class B.
Low Voltage Directive, EMC Directive
Complies with IEC61000-3-2
178X61X268mm (without terminal block and screw) (WXHXD) /3.4kg max
Forced cooling (internal fan)
*1 Measured by 20MHz oscilloscope or Ripple-Noise meter(equivalent to KEISOKU-GIKEN : RM101).
Ripple and ripple noise is measured on measuring board with capacitor of 22mF within 150mm from the output terminal.
Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C.
() means peak current. Peak loading for 10s. And Duty 35% max, refer to Instruction manual in detail.
Overvoltage protection circuit to follow to output voltage setting.
A sound may occur from power supply at pulse loading.
*2
*3
*4
*
A-18