PAA75F

Ordering information
Unit type
PAA75F
PAA
PAA
1
75
2
F
3
-5
-O
4
5
1Series name
2Output wattage
3Universal input
4Output voltage
5Optional
C :with Coating
G :Low leakage current
J :Connector type
N :with Cover
R :with Remote ON/OFF
R
MODEL
MAX OUTPUT WATTAGE[W]
DC OUTPUT
PAA75F-3
45
3V 15A
PAA75F-5
75
5V 15A
PAA75F-12
75.6
12V 6.3A
PAA75F-15
75
15V 5A
PAA75F-24
76.8
24V 3.2A
PAA75F-48
76.8
48V 1.6A
SPECIFICATIONS
MODEL
VOLTAGE[V]
CURRENT[A]
INPUT
OUTPUT
PROTECTION
CIRCUIT AND
OTHERS
ISOLATION
ENVIRONMENT
SAFETY AND
NOISE
REGULATIONS
OTHERS
*1
*2
*3
*
FREQUENCY[Hz]
EFFICIENCY[%]
POWER FACTOR
ACIN 100V
ACIN 200V
ACIN 100V
ACIN 100V
INRUSH CURRENT[A]
ACIN 200V
LEAKAGE CURRENT[mA]
VOLTAGE[V]
CURRENT[A]
LINE REGULATION[mV]
LOAD REGULATION[mV]
0 to +50C *1
RIPPLE[mVp-p]
-10 - 0C *1
0 to +50C *1
RIPPLE NOISE[mVp-p]
-10 - 0C *1
0 to +50C
TEMPERATURE REGULATION[mV]
-10 to +50C
*2
DRIFT[mV]
START-UP TIME[ms]
HOLD-UP TIME[ms]
OUTPUT VOLTAGE ADJUSTMENT RANGE[V]
OVERCURRENT PROTECTION
OVERVOLTAGE PROTECTION
OPERATING INDICATION
REMOTE ON/OFF
*3
INPUT-OUTPUT-RC
INPUT-FG
*3
OUTPUT-RC-FG
*3
OUTPUT-RC
OPERATING TEMP.,HUMID.AND ALTITUDE
STORAGE TEMP.,HUMID.AND ALTITUDE
VIBRATION
IMPACT
AGENCY APPROVALS
CONDUCTED NOISE
HARMONIC ATTENUATOR
CASE SIZE/WEIGHT
COOLING METHOD
PAA75F-3
PAA75F-5
PAA75F-12
PAA75F-15
PAA75F-24
PAA75F-48
AC85 - 264 1f
0.7typ
1.2typ
0.35typ
0.6typ
50/60 (47 - 63)
67typ
74typ
77typ
78typ
80typ
80typ
0.95typ (Io=100%)
15typ (Io=100%)
15typ (Io=100%)
0.75max (60Hz, According to UL, CSA, VDE and DEN-AN)
3
5
12
15
24
48
15
15
6.3
5
3.2
1.6
20max
20max
48max
60max
96max
192max
40max
40max
100max
120max
150max
240max
80max
80max
120max
120max
120max
150max
140max
140max
160max
160max
160max
200max
120max
120max
150max
150max
150max
250max
160max
160max
180max
180max
180max
300max
50max
50max
120max
150max
240max
480max
60max
60max
150max
180max
290max
600max
20max
20max
48max
60max
96max
192max
500max (ACIN 85V, Io=100%)
10typ (ACIN 85V, Io=100%) 20typ (ACIN 100V, Io=100%) 100typ (ACIN 200V, Io=100%)
2.85 - 3.6
t10%
Works over 105% of rating and recovers automatically
4.00 - 5.25V
Works at 115 - 140% of rating
LED (Green)
Optional (Refer to Instruction Manual)
AC3,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At Room Temperature)
AC2,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At Room Temperature)
AC500V 1minute, Cutoff current = 100mA, DC500V 50MW min (At Room Temperature)
AC100V 1minute, Cutoff current = 100mA, DC100V 10MW min (At Room Temperature)
-10 to +65C, 20 - 90%RH (Non condensing) (Refer to DERATING CURVE), 3,000m (10,000feet) max
-20 to +75C, 20 - 90%RH (Non condensing), 9,000m (30,000feet) max
10 - 55Hz, 19.6m/s2 (2G), 3minutes period, 60minutes each along X, Y and Z axis
196.1m/s2 (20G), 11ms, once each X, Y and Z axis
UL 1950, EN60950, VDE0160, CSA C22.2 No.234 Complies with DEN-AN and IEC60950
Complies with FCC-B, CISPR22-B, EN55022-B, VCCI-B
Complies with IEC61000-3-2
42X93X175mm (without terminal block) (WXHXD) /550g max (without cover)
Convection
According to 20MHz oscilloscope or Ripple-Noise meter(equivalent to KEISOKU-GIKEN : RM101).
Drift is change in DC output for an eight hour period after a half-hour warm-up at 25C, with the input voltage held constant at the rated input/output.
Applicable when Remote ON/OFF(optional) is added.
Derating is required when operated with case cover.