ROITHNER RLV4313

RLV4313
TECHNICAL DATA
Violet Laser Diode
Features
•
•
•
Peak Wavelength: 405 nm
Optical Output Power: 120 mW
Package: 5.6 mm, with Photo Diode
Electrical Connection
Pin Configuration
Bottom View
m-type
PIN
1
2
3
Function
LD Anode
LD Cathode, PD Cathode
PD Anode
Length of pins: 3mm
Absolute Maximum Ratings (TC=25°C)
Item
CW Output Power
LD Reverse Voltage
PD Reverse Voltage
Operating Case Temperature
Storage Temperature
Symbol
PO
VR (LD)
VR (PD)
TC
Tstg
Value
140
5
20
-10 … +70
-40 … +85
Unit
mW
V
V
°C
°C
Specifications (TC=25°C)
Item
Optical Specifications
CW Output Power
Peak Wavelength *
FWHM Beam Divergence
Emission Point Accuracy
Electrical Specifications
Threshold Current
Operating Current
Slope Efficiency
Operating Voltage
Monitor Current **
Angle
Symbol
Min.
Typ.
Max.
Unit
PO
λP
θ║
θ┴
Δθ║
Δθ┴
400
7.0
15.0
-2.0
-2.5
405
9.0
19.5
-
120
410
12.0
23.0
2.0
2.5
mW
nm
deg
deg
deg
deg
Ith
Iop
η
Uop
Im
1.2
0.2
35
120
1.4
4.8
0.4
50
150
1.9
5.5
0.7
mA
mA
W/A
V
mA
* Measuring specifications.
** Monitor Current is short time power reference purpose only.
Not guaranteed for accuracy.
The above specifications are for reference purpose only and subjected to change without prior notice.
25.09.2013
RLV4313
1 of 4
Package Dimensions
5.6 mm Package (Unit:mm)
Length of pins: 3mm
25.09.2013
RLV4313
2 of 4
Typical Characteristics
Optical Output Power vs. Forward Current
Forward Voltage vs. Forward Current
Threshold Current vs. Case Temperature
Peak Wavelength vs. Case Temperature
Far Field Pattern
Typical Spectrum
25.09.2013
RLV4313
3 of 4
Safety of Laser light
•
•
Laser Light can damage the human eyes and skin. Do not expose the
eye or skin directly to any laser light and/or through optical lens. When
handling the LDs, wear appropriate safety glasses to prevent laser
light, even any reflections from entering to the eye. Focused laser
beam through optical instruments will increase the chance of eye
hazard.
These LDs are classified in Class 4 of IEC60825-1 and 21 CFR Part 1040.10 Safety
Standards. It is absolutely necessary to take overall safety measures against User’s modules,
equipment and systems into which this LDs are incorporated and/or integrated.
Cautions
1. Operating method
• This LD shall change its forward voltage requirement and optical output power according to
temperature change. Also, the LD will require more operation current to maintain same
output power as it degrades. In order to maintain output power, use of APC (Automatic
Power Control) is recommended. Which use monitor feedback to adjust the operation
current.
• Confirm that electrical spike current generated by switching on and off does not exceed the
maximum operating current level specified herein above as absolute maximum rating. Also,
employ appropriate countermeasures to reduce chattering and/or overshooting in the circuit.
2. Static Electricity
• Static electricity or electrical surges will reduce and degrade the reliability of the LDs. It is
recommended to use a wrist trap or anti-electrostatic glove when handling the Product.
3. Absolute Maximum Rating
• Active layer of LDs shall have high current density and generate high electric field during its
operation. In order to prevent excessive damage, the LD must be operated strictly below
absolute maximum rating.
25.09.2013
RLV4313
4 of 4