MA-COM MW3

MW3 / MW4 / MW6 / MW3HP / MW4HP / MW6HP Series Relays
Microwave Switching, Hermetically Sealed, DPDT
Product Facts
■ Excellent signal isolation,
stable insertion loss and
low VSWR.
■ Provide repeatable RF
performance at frequencies
up to the 3 GHz. level
(MW3/MW3HP),
4 GHz. level (MW4/MW4HP)
& 6 GHz. level
(MW6/MW6HP).
■ Standard versions for
applications ranging from
wireless communications to
precision high-speed test
equipment.
■ High performance (HP)
versions for use under more
demanding environmental
conditions.
■ Standard or sensitive (S)
coils are offered in a range
of DC input voltages.
■ 2 Form C (DPDT) contacts
rated low-level to 1 amp.
■ Extended mechanical life
expectancy of 10 million
opertions.
■ Robust, hermetically sealed
enclosure.
These CII relays provide
microwave frequency
switching in a hermetically
sealed, subminiature
package.
Both standard and high
performance models are
offered in 3 GHz., 4 GHz.
and 6 GHz. types.
Standard models (MW3,
MW4 and MW6) perform in
temperature ranges from
-55°C to +85°C and
withstand 10G vibration and
30G shock.
High performance models
(MW3HP, MW4HP and
MW6HP) offer extended
temperature ratings of
-65°C to +125°C while
providing 30G’s vibration
and 100G’s shock (75G’s
for MW3) environmental
ratings.
Signal isolation is 18dB at 6
GHz. (MW6/MW6HP), 18dB
at 4 GHz. (MW4/MW4HP),
and 22dB at 3 GHz.
(MW3/MW3HP).
All are available with either
standard or sensitive DC
coils. Nominal coil power is
367-500mW (model
dependent) for standard
coils and 169-250mW for
sensitive coils.
VSWR is a low 1.30:1 @
6GHz. for MW6/MW6HP,
1.36:1 @ 4GHz. for
MW4/MW4HP, and 1.24:1
@ 3GHz. for MW3/MW3HP.
Insertion loss is 0.38dB for
MW6/MW6HP, 0.27dB for
MW4/MW4HP, and 0.36dB
for MW3/MW3HP.
© 2003 by Tyco Electronics Corporation. All Rights Reserved.
CII and TYCO are trademarks.
1
Catalog 1654542
Issued 12-03
www.tycoelectronics.com
Dimensions are in inches and
millimeters unless otherwise
specified. Values in brackets
are metric equivalents.
Dimensions are shown for
reference purposes only.
Specifications subject
to change.
USA: 1-800-522-6752
Canada: 1-905-470-4425
Mexico: 01-800-733-8926
C. America: 52-55-5-729-0425
South America: 55-11-3611-1514
Hong Kong: 852-2735-1628
Japan: 81-44-844-8013
UK: 44-141-810-8967
MW3 / MW4 / MW6 / MW3HP / MW4HP / MW6HP Series Relays
Microwave Switching, Hermetically Sealed, DPDT (Continued)
MW3 & MW3HP Models
3 GHz. Switching
Electrical Characteristics
Contact Ratings
Contact Arrangement:
2 Form C (DPDT)
Contact Load
Type
1.0A @ 28VDC
Resistive
100,000
200mA @ 28VDC (300mH)*
Inductive
100,000
30µA @ 50mVDC
Low Level
10,000,000
Contact Resistance:
Before life: 100 milliohms, max
(measured @ 10mA @ 6VDC.)
After life: 200 milliohms, max
(measured @ 1A @ 28VDC.)
Operations (min.)
* The inductive rating is only applicable to high performance models (MW3HP and MW3HPS).
Mechanical Life Expectancy:
10 million operations
Coil Voltages:
5, 12, 18 & 26.5VDC (MW3)
5, 6, 9, 12, 18 & 26.5VDC (MW3HP)
Coil Power (mw max @25°C):
MW3 MW3S MW3HP MW3HPS
675
565
673
563
Duty Cycle:
Continuous
Coil Data
MW3 Models
Nominal
Coil Voltage
(VDC)
Coil Resistance
In Ohms
±20% @ 25°C
Pickup Voltage
VDC (Max.)
@ 25°C
Nominal
Coil Power
(mw) @ 25°C
Maximum
Coil
Voltage
Coil
Designator
5.0
50
3.6
500
5.8
5
12.0
390
8.4
369
16.0
12
18.0
880
13.0
368
24.0
18
26.5
1,560
17.0
450
32.0
26
Standard Coil
Pick-up Voltage:
MW3: Approx 70% of nominal.
MW3HP: Approx 50% of nominal.
Pick-up Sensitivity (mw max @25°C):
MW3 MW3S MW3HP MW3HPS
180
90
146
68
Sensitive Coil
5.0
100
3.5
250
7.5
5
12.0
850
9.0
169
20.0
12
Operating Characteristics
18.0
1,600
13.5
203
30.0
18
Timing:
Operate Time (ms max.)
MW3 MW3S MW3HP MW3HPS
4.0
6.0
2.0
4.0
Release Time (ms max.)
MW3 MW3S MW3HP MW3HPS
3.0
3.0
1.5
2.0
Bounce Time (ms max.)
MW3 MW3S MW3HP MW3HPS
–
–
1.5
1.5
26.5
3,300
18.0
213
40.0
26
Dielectric Withstanding Voltage:
Between Open Contacts,
Between Adjacent Contacts and
Between Contacts and Coil:
MW3 types: 350Vrms, 60 Hz.
MW3HP types: 500Vrms, 60 Hz.
Insulation Resistance:
1,000 megohms @ 500VDC.
Environmental Characteristics
Temperature Range:
MW3 types: -55°C to +85°C.
MW3HP types: -65°C to +125°C.
MW3HP (High Performance) Models
Nominal
Coil Res.
Pickup V
Coil Voltage
in Ohms
VDC (Max.)
(VDC)
±10% @ 25°C
@25°C
Release V
VDC (Max.)
@25°C
Release V
VDC (Min.)
@25°C
Nominal
Coil Power
(mw) @25°C
Maximum
Coil
Voltage
Coil
Designator
Standard Coil
5.0
50
2.7
1.4
0.22
500
5.8
5
6.0
98
3.5
2.0
0.28
367
8.0
6
9.0
220
5.3
3.0
0.54
368
12.0
9
12.0
390
7.0
4.0
0.63
369
16.0
12
18.0
880
10.5
6.0
0.91
368
24.0
18
26.5
1,560
14.2
8.0
1.37
450
32.0
26
5.0
100
2.6
1.4
0.23
250
7.5
5
6.0
200
3.4
2.0
0.28
180
10.0
6
9.0
400
4.85
3.0
0.55
203
15.0
9
12.0
850
7.0
4.0
0.64
169
20.0
12
18.0
1,600
9.8
6.0
0.92
203
30.0
18
26.5
3,300
14.0
8.0
1.4
213
40.0
26
Sensitive Coil
Weight:
MW3, MW3HP: 0.09 oz. (2.55 g)
MW3S, MW3HPS: 0.12 oz. (3.40 g).
Vibration Resistance:
MW3 types:10 G’s, 10-500 Hz.
MW3HP types: 30 G’s, 10-3,000 Hz
Shock Resistance:
MW3 types:30 G’s, 6 ± 1 ms.
MW3HP types: 75 G’s, 6 ± 1 ms.
2
Catalog 1654542
Issued 12-03
www.tycoelectronics.com
Dimensions are in inches and
millimeters unless otherwise
specified. Values in brackets
are metric equivalents.
Dimensions are shown for
reference purposes only.
Specifications subject
to change.
USA: 1-800-522-6752
Canada: 1-905-470-4425
Mexico: 01-800-733-8926
C. America: 52-55-5-729-0425
South America: 55-11-3611-1514
Hong Kong: 852-2735-1628
Japan: 81-44-844-8013
UK: 44-141-810-8967
MW3 / MW4 / MW6 / MW3HP / MW4HP / MW6HP Series Relays
Microwave Switching, Hermetically Sealed, DPDT (Continued)
MW3 & MW3HP Models
3 GHz. Switching
Insertion Loss & VSWR: NC Contacts
Insertion Loss & VSWR: NO Contacts
(dB)
VSWR
(dB)
Isolation
VSWR
0.0
2.0
0.0
2.0
0.1
1.9
0.1
1.9
INSERTION LOSS
INSERTION LOSS
1.8
0.2
0.3
1.7
0.3
1.7
0.4
1.6
0.4
1.6
0.5
1.5
0.5
1.5
0.6
1.4
0.6
1.4
0.7
1.3
0.7
1.3
0.8
1.2
0.8
1.1
0.9
1.0
1.0
0.2
VSWR
0.9
1.0
0
0.5
1.0
1.5
2.0
2.5
3.0
1.8
1.2
VSWR
0
0.5
FREQUENCY (GHz)
1.0
1.5
(dB)
0
-10
-20
ISOLATION
-30
-40
1.1
2.0
2.5
1.0
3.0
-50
0
0.5
FREQUENCY (GHz)
1.0
1.5
2.0
2.5
3.0
FREQUENCY (GHz)
Test Conditions
Test Board: 0.031” double sided copper clad, PTFE based laminate.
Connections: Relay header is soldered to ground place. Relay terminals are soldered to through holes. SMA connectors are soldered to circuit traces.
Temperature: Room ambient.
Signal Strength: 0 dBm.
Notes: 1. Unused terminals were terminated with 50 ohm impedance load. 2. All readings are typical.
Header
Enclosures
.370 (9.40) DIA MAX
.031 ± .003
(0.79)
.335 (8.51) DIA MAX
.335 (8.51) DIA MAX
.035 ± .010
(0.89)
.370 (9.40) DIA MAX
.031 ± .003
GROUND PIN (0.79)
(OPTIONAL)
.035 ± .010
(0.89)
.385 (9.78)
MAX
.275 (6.99)
MAX
36°+ 3°
TERMINAL
A = .750 MIN (19.05)
P = .187±.010 (4.75±.25)
+.002
-.001
(0.43) DIA
.370 (9.40) DIA MAX
.370 (9.40) DIA MAX
MW3 / MW3HP
MW3S / MW3HPS
Part Numbering System
.200 DIA
(5.08)
36°+ 3°
Ground Pin
Position “G”
.017
.017 +.002
-.001 (0.43) DIA
.200 DIA
(5.08)
GROUND PIN
(OPTIONAL)
Ground Pin
Position “E”
For other ground pin configurations consult factory.
Header and Terminal Finish:
Nickel plated on MW3 & MW3S.
Tin-lead plated on MW3HP & MW3HPS.
Wiring Diagram
Typical Part Number
MW3 S – 5 A
Series:
MW3 = 3 GHz. switching relay
MW3HP = High performance 3 GHz. switching relay
Coil Sensitivity:
Leave Blank = Standard Coil
S = Sensitive Coil
Coil Designator:
5 = 5VDC
6 = 6VDC†
9 = 9VDC†
12 = 12VDC
18 = 18VDC
26 = 26.5VDC
† 6 and 9 volt coil only available on high performance models.
Terminal Length:
A = 0.750 in (19.05 mm)
P = 0.187 ± 0.010 in (4.75 ± 0.25 mm)
Ground Pin Position (see header drawings above):
G = Opposite locating tab
E = Near locating tab.
Consult factory for other ground pin configurations.
G
Terminal View
3
Catalog 1654542
Issued 12-03
www.tycoelectronics.com
Dimensions are in inches and
millimeters unless otherwise
specified. Values in brackets
are metric equivalents.
Dimensions are shown for
reference purposes only.
Specifications subject
to change.
USA: 1-800-522-6752
Canada: 1-905-470-4425
Mexico: 01-800-733-8926
C. America: 52-55-5-729-0425
South America: 55-11-3611-1514
Hong Kong: 852-2735-1628
Japan: 81-44-844-8013
UK: 44-141-810-8967
MW3 / MW4 / MW6 / MW3HP / MW4HP / MW6HP Series Relays
Microwave Switching, Hermetically Sealed, DPDT (Continued)
MW4 & MW4HP Models
4 GHz. Switching
Electrical Characteristics
Contact Ratings
Contact Arrangement:
2 Form C (DPDT)
Contact Load
Type
1.0A @ 28VDC
Resistive
100,000
200mA @ 28VDC (300mH)*
Inductive
100,000
30µA @ 50mVDC
Low Level
10,000,000
Contact Resistance:
Before life: 100 milliohms, max
(measured @ 10mA @ 6VDC.)
After life: 200 milliohms, max
(measured @ 1A @ 28VDC.)
Operations (min.)
* The inductive rating is only applicable to high performance models (MW4HP and MW4HPS).
Mechanical Life Expectancy:
10 million operations
Coil Voltages:
5, 12, 18 & 26.5VDC (MW4)
5, 6, 9, 12, 18 & 26.5VDC (MW4HP)
Coil Power (mw max @25°C):
MW4 MW4S MW4HP MW4HPS
675
565
673
563
Duty Cycle:
Continuous
Coil Data
MW4 Models
Nominal
Coil Voltage
(VDC)
Coil Resistance
In Ohms
±20% @ 25°C
Pickup Voltage
VDC (Max.)
@ 25°C
Nominal
Coil Power
(mw) @ 25°C
Maximum
Coil
Voltage
Coil
Designator
Standard Coil
Pick-up Voltage:
MW4: Approx 70% of nominal.
MW4HP: Approx 50% of nominal.
Pick-up Sensitivity (mw max @25°C):
MW4 MW4S MW4HP MW4HPS
180
90
123
68
5.0
50
3.6
500
5.8
5
12.0
390
8.4
369
16.0
12
18.0
880
13.0
368
24.0
18
26.5
1,560
17.0
450
32.0
26
Sensitive Coil
5.0
100
3.5
250
7.5
5
12.0
850
9.0
169
20.0
12
Operating Characteristics
18.0
1,600
13.5
203
30.0
18
Timing:
Operate Time (ms max.)
MW4 MW4S MW4HP MW4HPS
4.0
6.0
2.0
4.0
Release Time (ms max.)
MW4 MW4S MW4HP MW4HPS
3.0
3.0
1.5
2.0
Bounce Time (ms max.)
MW4 MW4S MW4HP MW4HPS
–
–
1.5
1.5
26.5
3,300
18.0
213
40.0
26
Dielectric Withstanding Voltage:
Between Open Contacts,
Between Adjacent Contacts and
Between Contacts and Coil:
MW4 types: 350Vrms, 60 Hz.
MW4HP types: 500Vrms, 60 Hz.
Insulation Resistance:
1,000 megohms @ 500VDC.
Environmental Characteristics
Temperature Range:
MW4 types: -55°C to +85°C.
MW4HP types: -65°C to +125°C.
MW4HP (High Performance) Models
Nominal
Coil Res.
Pickup V
Coil Voltage
in Ohms
VDC (Max.)
(VDC)
±10% @ 25°C
@25°C
Release V
VDC (Max.)
@25°C
Release V
VDC (Min.)
@25°C
Nominal
Coil Power
(mw) @25°C
Maximum
Coil
Voltage
Coil
Designator
Standard Coil
5.0
50
2.7
1.4
0.22
500
5.8
5
6.0
98
3.5
2.0
0.28
367
8.0
6
9.0
220
5.3
3.0
0.54
368
12.0
9
12.0
390
7.0
4.0
0.63
369
16.0
12
18.0
880
10.5
6.0
0.91
368
24.0
18
26.5
1,560
14.2
8.0
1.37
450
32.0
26
5.0
100
2.6
1.4
0.23
250
7.5
5
6.0
200
3.4
2.0
0.28
180
10.0
6
9.0
400
4.85
3.0
0.55
203
15.0
9
12.0
850
7.0
4.0
0.64
169
20.0
12
18.0
1,600
9.8
6.0
0.92
203
30.0
18
26.5
3,300
14.0
8.0
1.4
213
40.0
26
Sensitive Coil
Weight:
MW4, MW4HP: 0.09 oz. (2.55 g)
MW4S, MW4HPS: 0.12 oz. (3.40 g).
Vibration Resistance:
MW4 types:10 G’s, 10-500 Hz.
MW4HP types: 30 G’s, 10-3,000 Hz
Shock Resistance:
MW4 types:30 G’s, 6 ± 1 ms.
MW4HP types: 100 G’s, 6 ± 1 ms.
4
Catalog 1654542
Issued 12-03
www.tycoelectronics.com
Dimensions are in inches and
millimeters unless otherwise
specified. Values in brackets
are metric equivalents.
Dimensions are shown for
reference purposes only.
Specifications subject
to change.
USA: 1-800-522-6752
Canada: 1-905-470-4425
Mexico: 01-800-733-8926
C. America: 52-55-5-729-0425
South America: 55-11-3611-1514
Hong Kong: 852-2735-1628
Japan: 81-44-844-8013
UK: 44-141-810-8967
MW3 / MW4 / MW6 / MW3HP / MW4HP / MW6HP Series Relays
Microwave Switching, Hermetically Sealed, DPDT (Continued)
MW4 & MW4HP Models
4 GHz. Switching
Insertion Loss & VSWR: NC Contacts
Insertion Loss & VSWR: NO Contacts
(dB)
VSWR
(dB)
Isolation
VSWR (dB)
0.0
2.0
0.0
2.0
0.05
1.9
0.05
1.9
0.10
1.8
0.10
0.15
1.7
0.15
1.7
0.20
1.6
0.20
1.6
0.25
1.5
0.25
1.5
0.30
1.4
0.30
1.4
0.35
1.3
0.35
1.3
1.2
0.40
1.1
0.45
1.0
4.0
0.50
INSERTION LOSS
VSWR
0.40
0.45
0.50
0
0.5
1.0
1.5
2.0
2.5
3.0
3.5
1.8
INSERTION LOSS
1.2
VSWR
0
FREQUENCY (GHz)
0.5
1.0
1.5
2.0
0
-10
ISOLATION
-20
-30
-40
1.1
2.5
3.0
3.5
1.0
4.0
-50
0
0.5
1.0
1.5
2.0
2.5
3.0
3.5
4.0
FREQUENCY (GHz)
FREQUENCY (GHz)
Test Conditions
Test Board: 0.031” double sided copper clad, PTFE based laminate.
Connections: Relay header is soldered to ground place. Relay terminals are soldered to through holes. SMA connectors are soldered to circuit traces.
Temperature: Room ambient.
Signal Strength: 0 dBm.
Notes: 1. Unused terminals were terminated with 50 ohm impedance load. 2. All readings are typical.
Header
Enclosures
.335 (8.51) SQ MAX
.335 (8.51) SQ MAX
.375 (9.53) SQ MAX
.031± .003 (0.79)
.035± .010
(0.98)
.385 (9.78)
MAX
.280 (7.11)
MAX
.017 +.002
-.001 (0.43) DIA
.370 (9.40) SQ MAX
MW4 / MW4HP
.200 DIA
(5.08)
36°+ 3°
TERMINAL
P = .187±.010 (4.75±.25)
A = .750 MIN (19.05)
B = 1.50 MIN (38.10)
Header and Terminal Finish:
Gold plated
.017 +.002
-.001 (0.43) DIA
.370 (9.40) SQ MAX
MW4S / MW4HPS
Part Numbering System
Wiring Diagram
Typical Part Number
MW4 S – 5 P
Series:
MW4 = 4 GHz. switching relay
MW4HP = High performance 4 GHz. switching relay
Coil Sensitivity:
Leave Blank = Standard Coil
S = Sensitive Coil
Coil Designator:
5 = 5VDC
6 = 6VDC†
9 = 9VDC†
12 = 12VDC
18 = 18VDC
26 = 26.5VDC
† 6 and 9 volt coil only available on high performance models.
Terminal Length:
A = 0.750 in (19.05 mm)
B = 1.50 in (38.105 mm) – only available on high performance models
P = 0.187 ± 0.010 in (4.75 ± 0.25 mm)
Terminal View
5
Catalog 1654542
Issued 12-03
www.tycoelectronics.com
Dimensions are in inches and
millimeters unless otherwise
specified. Values in brackets
are metric equivalents.
Dimensions are shown for
reference purposes only.
Specifications subject
to change.
USA: 1-800-522-6752
Canada: 1-905-470-4425
Mexico: 01-800-733-8926
C. America: 52-55-5-729-0425
South America: 55-11-3611-1514
Hong Kong: 852-2735-1628
Japan: 81-44-844-8013
UK: 44-141-810-8967
MW3 / MW4 / MW6 / MW3HP / MW4HP / MW6HP Series Relays
Microwave Switching, Hermetically Sealed, DPDT (Continued)
MW6 & MW6HP Models
6 GHz. Switching
Electrical Characteristics
Contact Ratings
Contact Arrangement:
2 Form C (DPDT)
Contact Load
Type
1.0A @ 28VDC
Resistive
100,000
200mA @ 28VDC (300mH)*
Inductive
100,000
30µA @ 50mVDC
Low Level
10,000,000
Contact Resistance:
Before life: 100 milliohms, max
(measured @ 10mA @ 6VDC.)
After life: 200 milliohms, max
(measured @ 1A @ 28VDC.)
Operations (min.)
* The inductive rating is only applicable to high performance models (MW6HP and MW6HPS).
Mechanical Life Expectancy:
10 million operations
Coil Voltages:
5, 12, 18 & 26.5VDC (MW6)
5, 6, 9, 12, 18 & 26.5VDC (MW6HP)
Coil Power (mw max @25°C):
MW6 MW6S MW6HP MW6HPS
675
565
673
563
Duty Cycle:
Continuous
Coil Data
MW6 Models
Nominal
Coil Voltage
(VDC)
Coil Resistance
In Ohms
±20% @ 25°C
Pickup Voltage
VDC (Max.)
@ 25°C
Nominal
Coil Power
(mw) @ 25°C
Maximum
Coil
Voltage
Coil
Designator
5.0
50
3.6
500
5.8
5
12.0
390
8.4
369
16.0
12
18.0
880
13.0
368
24.0
18
26.5
1,560
17.0
450
32.0
26
Standard Coil
Pick-up Voltage:
MW6: Approx 70% of nominal.
MW6HP: Approx 50% of nominal.
Pick-up Sensitivity (mw max @25°C):
MW6 MW6S MW6HP MW6HPS
180
90
123
68
Sensitive Coil
5.0
100
3.5
250
7.5
5
12.0
850
9.0
169
20.0
12
Operating Characteristics
18.0
1,600
13.5
203
30.0
18
Timing:
Operate Time (ms max.)
MW6 MW6S MW6HP MW6HPS
4.0
6.0
2.0
4.0
Release Time (ms max.)
MW6 MW6S MW6HP MW6HPS
3.0
3.0
1.5
2.0
Bounce Time (ms max.)
MW6 MW6S MW6HP MW6HPS
–
–
1.5
1.5
26.5
3,300
18.0
213
40.0
26
Dielectric Withstanding Voltage:
Between Open Contacts,
Between Adjacent Contacts and
Between Contacts and Coil:
MW6 types: 350Vrms, 60 Hz.
MW6HP types: 500Vrms, 60 Hz.
Insulation Resistance:
1,000 megohms @ 500VDC.
Environmental Characteristics
Temperature Range:
MW6 types: -55°C to +85°C.
MW6HP types: -65°C to +125°C.
MW6HP (High Performance) Models
Nominal
Coil Res.
Pickup V
Coil Voltage
in Ohms
VDC (Max.)
(VDC)
±10% @ 25°C
@25°C
Release V
VDC (Max.)
@25°C
Release V
VDC (Min.)
@25°C
Nominal
Coil Power
(mw) @25°C
Maximum
Coil
Voltage
Coil
Designator
Standard Coil
5.0
50
2.7
1.4
0.22
500
5.8
5
6.0
98
3.5
2.0
0.28
367
8.0
6
9.0
220
5.3
3.0
0.54
368
12.0
9
12.0
390
7.0
4.0
0.63
369
16.0
12
18.0
880
10.5
6.0
0.91
368
24.0
18
26.5
1,560
14.2
8.0
1.37
450
32.0
26
5.0
100
2.6
1.4
0.23
250
7.5
5
6.0
200
3.4
2.0
0.28
180
10.0
6
9.0
400
4.85
3.0
0.55
203
15.0
9
12.0
850
7.0
4.0
0.64
169
20.0
12
18.0
1,600
9.8
6.0
0.92
203
30.0
18
26.5
3,300
14.0
8.0
1.4
213
40.0
26
Sensitive Coil
Weight:
MW6, MW6HP: 0.09 oz. (2.55 g)
MW6S, MW6HPS: 0.12 oz. (3.40 g).
Vibration Resistance:
MW6 types:10 G’s, 10-500 Hz.
MW6HP types: 30 G’s, 10-3,000 Hz
Shock Resistance:
MW6 types:30 G’s, 6 ± 1 ms.
MW6HP types: 100 G’s, 6 ± 1 ms.
6
Catalog 1654542
Issued 12-03
www.tycoelectronics.com
Dimensions are in inches and
millimeters unless otherwise
specified. Values in brackets
are metric equivalents.
Dimensions are shown for
reference purposes only.
Specifications subject
to change.
USA: 1-800-522-6752
Canada: 1-905-470-4425
Mexico: 01-800-733-8926
C. America: 52-55-5-729-0425
South America: 55-11-3611-1514
Hong Kong: 852-2735-1628
Japan: 81-44-844-8013
UK: 44-141-810-8967
MW3 / MW4 / MW6 / MW3HP / MW4HP / MW6HP Series Relays
Microwave Switching, Hermetically Sealed, DPDT (Continued)
MW6 & MW6HP Models
6 GHz. Switching
Insertion Loss & VSWR: NC Contacts
Insertion Loss & VSWR: NO Contacts
(dB)
VSWR (dB)
VSWR
0.0
2.0
0.0
2.0
0.1
1.9
0.1
1.9
1.8
0.2
0.3
1.7
0.3
0.4
1.6
0.4
1.6
0.5
1.5
0.5
1.5
0.6
1.4
0.6
1.4
0.7
1.3
0.7
1.3
1.2
0.8
1.1
0.9
INSERTION LOSS
0.2
0.8
VSWR
0.9
1.0
0
1.0
0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 5.5 6.0
1.0
0
FREQUENCY (GHz)
1.8
INSERTION LOSS
0
-10
1.7
1.2
VSWR
Isolation
(dB)
-20
ISOLATION
-30
-40
1.1
1.0
0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 5.5 6.0
-50
0
0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 5.5 6.0
FREQUENCY (GHz)
FREQUENCY (GHz)
Test Conditions
Test Board: 0.031” double sided copper clad, PTFE based laminate.
Connections: Relay header is soldered to ground place. Relay terminals are soldered to through holes. SMA connectors are soldered to circuit traces.
Temperature: Room ambient.
Signal Strength: 0 dBm.
Notes: 1. Unused terminals were terminated with 50 ohm impedance load. 2. All readings are typical.
Header
Enclosures
.335 (8.51) SQ MAX
.335 (8.51) SQ MAX
.375 (9.53) SQ MAX
.031± .003 (0.79)
.035± .010
(0.98)
.385 (9.78)
MAX
.280 (7.11)
MAX
.017
+.002
-.001
(0.43) DIA
.370 (9.40) SQ MAX
MW6 / MW6HP
.200 DIA
(5.08)
36°+ 3°
TERMINAL
P = .187±.010 (4.75±.25)
A = .750 MIN (19.05)
B = 1.50 MIN (38.10)
.017 +.002
-.001 (0.43) DIA
.370 (9.40) SQ MAX
Header and Terminal Finish:
Gold plated
MW6S / MW6HPS
Part Numbering System
Wiring Diagram
Typical Part Number
MW6 S – 5 P
Series:
MW6 = 6 GHz. switching relay
MW6HP = High performance 6 GHz. switching relay
Coil Sensitivity:
Leave Blank = Standard Coil
S = Sensitive Coil
Coil Designator:
5 = 5VDC
6 = 6VDC†
9 = 9VDC†
12 = 12VDC
18 = 18VDC
26 = 26.5VDC
† 6 and 9 volt coil only available on high performance models.
Terminal Length:
A = 0.750 in (19.05 mm)
B = 1.50 in (38.105 mm) – only available on high performance models
P = 0.187 ± 0.010 in (4.75 ± 0.25 mm)
Terminal View
7
Catalog 1654542
Issued 12-03
www.tycoelectronics.com
Dimensions are in inches and
millimeters unless otherwise
specified. Values in brackets
are metric equivalents.
Dimensions are shown for
reference purposes only.
Specifications subject
to change.
USA: 1-800-522-6752
Canada: 1-905-470-4425
Mexico: 01-800-733-8926
C. America: 52-55-5-729-0425
South America: 55-11-3611-1514
Hong Kong: 852-2735-1628
Japan: 81-44-844-8013
UK: 44-141-810-8967
Global Contacts
Americas
Argentina – Buenos Aires
Phone:
+54-11-4733-2200
Fax:
+54-11-4733-2250
Brasil – São Paulo
Phone:
+55-11-3611-1311
Fax:
+55-11-3611-0397
Canada – Markham
Phone:
+905-475-6222
Fax:
+905-474-5520
Product Information Center:
(Technical Support)
Phone:
+905-470-4425
Fax:
+905-474-5525
Colombia – Bogota
Phone:
+57-1-240-9396
Fax:
+57-1-660-0206
Mexico – Mexico City
Phone:
+52-55-5-729-0425
Fax:
+52-55-5-398-1430
For Latin/South American
Countries not shown
Phone:
+57-1-240-9396
Fax:
+57-1-660-0206
United States – Harrisburg, PA
Phone:
+717-564-0100
Fax:
+717-986-7575
Product Information Center:
(Technical Support)
Phone:
+800-522-6752
Fax:
+717-986-7575
Asia/ Pacific
Australia – Sydney
Phone:
+61-2-9840-8200
Fax:
+61-2-9899-5649
Product Information Center:
(Technical Support)
Phone:
+61-2-9554-2600
Fax:
+61-2-9502-2556
India – Bangalore
Phone:
+91-80-841-0200
Fax:
+91-80-841-0210
Indonesia – Jakarta
Phone:
+6221-526-7852
Fax:
+6221-526-7856
Japan – Kawasaki, Kanagawa
Phone:
+81-44-844-8079
Fax:
+81-44-844-8733
Product Information Center:
(Technical Support)
Phone:
+81-44-844-8013
Fax:
+81-44-812-3200
Raychem Products
Phone:
+81-44-900-5102
Fax:
+81-44-5025-5027
Korea – Seoul
Phone:
+82-2-3274-0535
Fax:
+82-2-3274-0524/0531
Malaysia – Selangor
Phone:
+60-3-7053055
Fax:
+60-3-7053066
New Zealand – Auckland
Phone:
+64-9-634-4580
Fax:
+64-9-634-4586
Philippines – Makati City
Phone:
+632-867-8641
Fax:
+632-867-8661
People’s Republic of China
Hong Kong
Phone:
+852-2735-1628
Fax:
+852-2735-0243
Shanghai
Phone:
Fax:
+86-21-6485-0602
+86-21-6485-0728
Shunde
Phone:
Fax:
+86-765-775-1368
+86-765-775-2823
Singapore – Singapore
Phone:
+65-4820-311
Fax:
+65-4821-012
Raychem Products
Phone:
+65-4866-151
Fax:
+65-6545-514
Taiwan – Taipei
Phone:
+886-2-2664-9977
Fax:
+886-2-2664-9900
Thailand – Bangkok
Phone:
+66-2-955-0500
Fax:
+66-2-955-0505
Vietnam – Ho Chi Minh City
Phone:
+84-8-8232-546/7
Fax:
+84-8-8221-443
Europe/ Middle East/Africa
Austria – Vienna
Phone:
+43-190-560-0
Fax:
+43-190-560-1333
Belgium – Kessel-Lo
Phone:
+32-16-352-300
Fax:
+32-16-352-352
Germany – Bensheim
Phone:
+49-6251-133-0
Fax:
+49-6251-133-1600
Product Information Center:
(Technical Support)
Phone:
+49-6251-133-1999
Fax:
+49-6251-133-1988
Bulgaria – Sofia
Phone:
+359-2-971-2152
Fax:
+359-2-971-2153
Germany – Langen
Phone:
+49-6103-709-0
Fax:
+49-6103-709-1223
Czech Republic – Kurim
Phone:
+420-5-41-162-111
Fax:
+420-5-41-162-223
Germany – Speyer
Phone:
+49-6232-30-0
Fax:
+49-6232-30-2243
Denmark – Viby J
Phone:
+45-70-15-52-00
Fax:
+45-86-29-51-33
Germany
HTS Division – Neunkirchen
Phone:
+49-2247-305-0
Fax:
+49-2247-305-122
Egypt – Cairo
Phone:
+20-2-417-76-47
Fax:
+20-2-419-23-34
Estonia – Tallinn
Phone:
+372-65-05-474
Fax:
+372-65-05-470
Finland – Helsinki
Phone:
+358-95-12-34-20
Fax:
+358-95-12-34-250
France –
Cergy-Pontoise
Phone:
+33-1-3420-8888
Fax:
+33-1-3420-8600
Product Information Center:
(Technical Support)
Phone:
+33-1-3420-8943
Fax:
+33-1-3420-8623
France
Tyco Electronics Export –
St Ouen L’Aumone
Phone:
+33-1-3440-7200
Fax:
+33-1-3440-7220 or
+33-1-3440-7230
1654542–2.5M–KRG–FP–12-03
Printed in the U.S.A.
Great Britain –
Stanmore Middlesex
Phone:
+44-181-954-2356
Fax:
+44-181-954-6234
Product Information Center:
(Technical Support)
Freephone GB: 0800-267-666
Phone:
+44-141 810 8967…69
Fax:
+44-141 810 8971
Great Britain – Dorcan, Swindon
Raychem Products
Phone:
+44-1793-528171
Fax:
+44-1793-572516
Italy – Collegno (Torino)
Phone:
+39-011-4012-111
Fax:
+39-011-4031-116
Lithuania – Vilnius
Phone:
+370-5-21-31-402
Fax:
+370-5-21-31-403
Netherlands – ’s-Hertogenbosch
Phone:
+31-73-6246-246
Fax:
+31-73-6212-365
Product Information Center:
(Technical Support)
Phone:
+31-73-6246-999
Fax:
+31-73-6246-998
Norway – Nesbru
Phone:
+47-66-77-88-99
Fax:
+47-66-77-88-55
Poland – Warsaw
Phone:
+48-22-45-76-700
Fax:
+48-22-45-76-720
Romania – Bucharest
Phone:
+40-1-311-3479+3596
Fax:
+40-1-312-0574
Sweden – Upplands Väsby
Phone:
+46-8-50-72-50-00
Fax:
+46-8-50-72-50-01
Switzerland – Steinach
Phone:
+41-71-447-0447
Fax:
+41-71-447-0444
Turkey – Istanbul
Phone:
+90-212-281-8181…3
+90-212-282-5130/5430
Fax:
+90-212-281-8184
Ukraine – Kiev
Phone:
+38-044-238-6908
Fax:
+38-044-568-5740
Russia – Moscow
Phone:
+7-095-926-55-06…09
Fax:
+7-095-926-55-05
Russia – St. Petersburg
Phone:
+7-812-325-30-83
Fax:
+7-812-325-32-88
Greece – Athens
Phone:
+30-1-9370-396/397
Fax:
+30-1-9370-655
Scotland – Dundee
Madison Cable Products
Phone:
+44-1382-508080
Fax:
+44-1382-505060
Hungary – Budapest
Phone:
+36-1-289-1000
Fax:
+36-1-289-1010
Slovakia – Banská Bystrica
Phone:
+421-48-415-20-11/12
Fax:
+421-48-415-20-13
Ireland – Dublin
Phone:
+353-1-820-3000
Fax:
+353-1-820-9790
Slovenia – Ljubljana
Phone:
+386-1561-3270
Fax:
+386-1561-3240
Israel – Yokneam
Phone:
+972-4-959-0508
Fax:
+972-4-959-0506
Spain – Barcelona
Phone:
+34-93-291-0330
Fax:
+34-93-201-7879
Product Information Center:
(Technical Support):
Phone:
+34-93-291-0330
Fax:
+34-93-200-3779
South Africa – Port Elizabeth
Phone:
+27-41-405-4500
Fax:
+27-41-486-1314
Tyco Electronics Corporation
www.tycoelectronics.com