ETC RF303-5

RF & MICROWAVE
SERIES
HIGH REPEATABILITY
BROADBAND
TO-5 RELAYS
DPDT
SERIES
DESIGNATION
RF300
RF303
RELAY TYPE
RF300
Repeatable RF relay
RF303
Sensitive, repeatable RF relay
INTERNAL CONSTRUCTION
PERFORMANCE FEATURES
The ultraminiature RF300 and RF303 relays are designed to provide improved
RF signal repeatability over the frequency range. These relays are highly
UPPER
STATIONARY
CONTACT
UNI-FRAME
suitable for use in attenuator and other RF circuits, the RF 300 and RF303
feature:
MOVING
CONTACT
ARMATURE
LOWER
STATIONARY
CONTACT
• High repeatability.
• Broader bandwidth.
• Metal enclosure for EMI shielding.
• Ground pin option to improve case grounding.
• High isolation between control and signal paths.
• Highly resistant to ESD.
CONSTRUCTION FEATURES
The following unique construction features and manufacturing techniques
provide excellent resistance to environmental extremes and overall high
reliability.
ENVIRONMENTAL AND
PHYSICAL SPECIFICATIONS
–65°C to +125°C
Temperature Storage
(Ambient)
Operating –55°C to +85°C
Vibration
(General Note 1)
10 g’s to 500 Hz
Shock
(General Note 1)
30 g’s,
6 msec, half-sine
Enclosure
rigidity.
• Minimum mass components and welded construction provide maximum
resistance to shock and vibration.
• Advanced cleaning techniques provide maximum assurance of internal
Hermetically sealed
RF300
0.09 oz. (2.55g) max.
RF303
0.16 oz. (4.5g) max.
Weight
©2003 TELEDYNE RELAYS
• Uni-frame motor design provides high magnetic efficiency and mechanical
cleanliness.
• Gold-plated precious metal alloy contacts ensure reliable switching.
• Hermetically sealed.
• Solderable leads.
SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE
www.teledynerelays.com
RF300 RF303 Page 26
RF300 RF303/1203/Q1
RF & MICROWAVE
SERIES RF300 AND RF303
TYPICAL RF CHARACTERISTICS (See RF Notes)
Isolation Pole to Pole (RF Note 5)
0
-10
-10
-20
-20
Isolation (dB)
Isolation (dB)
Isolation Across Contacts (RF Note 4)
0
-30
-40
-30
-40
-50
-50
-60
-60
0
500
1000
1500
2000
2500
3000
3500
4000
4500
5000
5500
0
6000
500
1000
1500
2000
2.0
-0.2
1.8
-0.4
1.6
VSWR
Insertion Loss (dB)
3000
3500
4000
4500
5000
5500
6000
VSWR (RF Note 6)
Insertion Loss (RF Note 6)
0
-0.6
-0.8
-1
0
2500
Frequency (MHz)
Frequency (MHz)
1.4
1.2
1.0
500
1000
1500
2000
2500
3000
3500
4000
4500
5000
5500
0
6000
500
1000
1500
2000
Frequency (MHz)
2500
3000
3500
4000
4500
5000
5500
6000
Frequency (MHz)
RF300 Time Response (RF Note 6)
1.1
0.9
90%
Volt
0.7
37ps reference
0.5
62.3ps propagation delay time
0.3
51.1ps pulse rise time
10%
0.1
-0.1
-100
0
100
200
300
400
500
600
700
800
900
Time (ps)
RF NOTES
1. Test conditions:
2.
3.
4.
5.
6.
7.
a. Fixture: .031" copper clad, reinforced PTFE, RT/duroid® 6002 with SMA connectors. (RT/duroid® is a
registered trademark of Rogers Corporation.)
b. Room ambient temperature.
c. Terminals not tested were terminated with 50-ohm load.
d. Contact signal level: –10 dBm.
e. No. of test samples: 4.
Data presented herein represents typical characteristics and is not intended for use as specification limits.
Data is per pole, except for pole-to-pole data.
Data is the average from readings taken on all open contacts.
Data is the average from readings taken on poles with coil energized and de-energized.
Data is the average from readings taken on all closed contacts.
Test fixture effect de-embedded from frequency and time response data.
RF300 RF303 Page 27
SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE
www.teledynerelays.com
©2003 TELEDYNE RELAYS
RF300 RF303/1203/Q1
RF & MICROWAVE
SERIES RF300 AND RF303
RF REPEATABILITY PERFORMANCE (See RF Notes 1, 2 and 3)
1 million cycle repeatability
0.12
±0.1 dB from DC to 3GHz
Typical repeatability of attenuation during life (normally open contacts)
0.10
.080
±dB
.060
.040
MAX
.020
X
MIN.
0
1
2
3
4
5
6
Number of cycles X10
0.12
±dB
7
8
9
10
6
Typical repeatability of insertion loss during life (normally closed contacts)
0.10
MAX
.080
X
MIN.
.060
.040
.020
0
1
2
3
4
5
6
Number of cycles X10
7
8
9
10
6
RF NOTES
1. One million cycle repeatability data is based upon 396 observations with an average repeatability ±0.033 dB and a range of
±0.093 dB.
2. Repeatability of attenuation values were obtained from tests conducted in a 20 dB attenuator network with a 0 dBm input
signal.
3. Relay operates at frequencies higher than 3 GHz with reduced RF performance characteristics.
4. Curves were developed from tests performed on a 0.031" copper clad, reinforced PTFE circuit board at 20°C (ref). The unutilized contacts were terminated in 50 ohms; characteristic impedance of measuring equipment is 50 ohms. The relays were
mounted flush to the circuit board ground plane without the relay header soldered to the ground plane.
©2003 TELEDYNE RELAYS
SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE
www.teledynerelays.com
RF300 RF303 Page 28
RF300 RF303/1203/Q1
Contact arrangement
2 Form C (DPDT)
Rated duty
Continuous
Contact resistance
0.15 ohm max. initial (measured 1/8" from the header)
Contact load rating
Resistive: 1Amp/28Vdc
Low level: 10 to 50 µA, 10 to 50 mV
Contact life rating
10,000,000 cycles typical at low level
RF300: 450 mW typical @ nominal rated voltage
RF303: 200 mW typical @ nominal rated voltage
Coil operating power
Operate time
Release time
RF300
4.0 ms. max.
RF303
6.0 ms. max.
RF300
3.0 ms. max.
RF303
3.0 ms. max.
Intercontact capacitance
0.4 pF typical
1,000 MΩ min. (between mutually isolated terminals)
Insulation resistance
Dielectric strength
350 VRMS / 60 Hz @ atmospheric pressure
DETAILED ELECTRICAL SPECIFICATIONS (@25°C)
RF300-5
RF303-5
RF300-12
RF303-12
5.0
12.0
RF300
50
390
RF303
100
850
3.6
9.0
BASE PART NUMBERS
Coil voltage, nominal, VDC
Coil resistance, ohms ± 20%
Pick-up voltage max, VDC
OUTLINE DIMENSIONS
GENERAL NOTES
1. Relays will exhibit no contact chatter in excess of 10 µsec or transfer in excess of 1 µsec.
RF300 RF303 Page 29
SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE
www.teledynerelays.com
©2003 TELEDYNE RELAYS
RF300 RF303/1203/Q1
RF & MICROWAVE
SERIES RF300 AND RF303
GENERAL ELECTRICAL SPECIFICATIONS (@25°C)