MACOM GTCR36-351M-R10-FT

Gas Discharge Tubes
GTCX36-XXXM-R10 Series
TE Circuit Protection 6mm 3Pole GDTs (ceramic
gas discharge tubes), are commonly used to help
protect sensitive telecom equipment such as
communication lines, signal lines and data
transmission lines from damage caused by
transient surge voltages that typically result from
lightning strikes and equipment switching
operations.
TE Circuit Protection GDTs offer a high level of
surge protection, low capacitance and a broad
array of breakover voltage levels, making them
suitable for applications such as MDF (Main
Distribution Frame) modules, high data-rate
telecom applications (e.g. ADSL, VDSL), and
surge protection on power lines. Raychem Circuit
Protection GDTs can help equipment meet the
most stringent regulatory standards.
Benefits:
Features:
 Compact, small form factor suitable for efficient
assembly
 3Pole, 6mm devices
 Helps provide overvoltage fault protection against
high energy surges
 Various form factors: surface-mount, leaded, no
leads
 Suitable for high-frequency applications
 Optional fail-short mechanism on some devices
 Broad voltage range from 75V-600V
 Low capacitance and insertion loss
 Crowbar overvoltage protection
 UL 497B recognized
 RoHS compliant
 Devices tested per ITU K.12 recommendations
 Non-radioactive materials

Applications:
• Industrial and consumer electronics, such as
 Telecommunications
- MDF modules, xDSL equipment, RF system
- Surge protectors
protection, antenna, base station
- Alarm system
Gas Discharge Tubes
Document: SCD27380
Status: Released
Rev: C
Date: MAY 18, 2011
© 2008, 2011 Tyco Electronics Corporation.
a TE Connectivity Ltd. Company. All rights reserved.
1
Gas Discharge Tubes
GTCX36-XXXM-R10
Series
GTCX35-XXX-R05
Series
Device Voltage Ratings and Part Marking
Part Number
Impulse
Sparkover
DC Sparkover
DC Holdover
Voltage
On-State Voltage
@100V/s
±20% Tolerance
(V)
@100 Vµs (V)
@1000 Vµs (V)
GTCX36-750M-R10
75
450
550
<52
20
GTCX36-900M-R10
90
450
550
<52
20
GTCX36-141M-R10
140
500
600
<80
20
GTCX36-151M-R10
150
500
600
<80
20
GTCX36-201M-R10
200
600
700
<135
20
GTCX36-231M-R10
230
600
700
<135
20
GTCX36-251M-R10
250
600
700
<135
20
GTCX36-261M-R10
260
700
800
<135
20
GTCX36-301M-R10
300
800
900
<150
20
GTCX36-351M-R10
350
900
1000
<150
20
GTCX36-401M-R10
400
900
1000
<150
20
GTCX36-421M-R10
420
900
1000
<150
20
GTCX36-471M-R10
470
1050
1150
<150
20
GTCX36-501M-R10
500
1100
1200
<150
20
GTCX36-551M-R10
550
1300
1400
<150
20
GTCX36-601M-R10
600
1300
1400
<150
20
Per ITU K.12
(<150ms)
(V)
Nominal
(@ 1A)
(V)
Device Surge Rating, Capacitance, Insulation Resistance, UL
Part Number
GTCX36-XXXM-R10
Impulse
Discharge
Current
Impulse
Life
AC
Discharge
Current
(1sec duration;
10 hits)
Capacitance
Insulation
Resistance
UL
Rating
8x20µs
10 hits
10x1000µs
300 hits
@50 Hz
@1Mhz
@100V*
UL497B
#E179610
10kA
200A
10Arms
<1pF
10,000 (MΩ)
All Devices
* Devices <=150V measured @ 50V.
Devices >= 500V measured @ 250V
Gas Discharge Tubes
Document: SCD27380
Status: Released
Rev: C
Date: MAY 18, 2011
© 2008, 2011 Tyco Electronics Corporation.
a TE Connectivity Ltd. Company. All rights reserved.
2
Gas Discharge Tubes
GTCX36-XXXM-R10
Series
GTCX35-XXX-R05
Series
Product Dimensions
DIMENSIONS = MILLIMETERS [INCHES]
Axial Leaded with- FT (GTCA36-XXXM-R10-FT)
Axial Leaded (GTCA36-XXXM-R10)
Radial Leaded with- FT (GTCR36-XXXM-R10-FT)
Radial Leaded (GTCR36-XXXM-R10)
Gas Discharge Tubes
Document: SCD27380
Status: Released
Rev: C
Date: MAY 18, 2011
© 2008, 2011 Tyco Electronics Corporation.
a TE Connectivity Ltd. Company. All rights reserved.
3
Gas Discharge Tubes
GTCX36-XXXM-R10
Series
GTCX35-XXX-R05
Series
No Leads (GTCN36-XXXM-R10)
No Leads with- FT (GTCN36-XXXM-R10-FT)
Surface-mount (GTCS36-XXXM-R10)
Pad Layout – Surface-mount Devices (GTCS36-XXXM-R10)
mm:
in*:
X
NOM
7.0
(0.276)
Y1
NOM
3.6
(0.142)
Y2
NOM
3.6
(0.142)
Z1
NOM
2.5
(0.098)
Gas Discharge Tubes
Z2
NOM
2.0
(0.079)
Document: SCD27380
Status: Released
Rev: C
Date: MAY 18, 2011
© 2008, 2011 Tyco Electronics Corporation.
a TE Connectivity Ltd. Company. All rights reserved.
4
Gas Discharge Tubes
GTCX36-XXXM-R10
Series
GTCX35-XXX-R05
Series
General Characteristics
No Radioactive Material
Storage Temperature: -40ºC to +90ºC
Operating Temperature: -40ºC to +90ºC
Body: Nickel Plated
Leads: Surface-mount, Radial and Axial Devices: Tin Plated
Devices with no leads: Nickel Plated
Soldering Notes: Devices with no leads: non-solderable; suitable for insertion into a magazine clip
Materials Information
RoHS Compliant
ELV Compliant
Packaging Information
Part Description
Tray / Reel
Standard Package
No Leaded:
GTCN36-XXXM-R10
With Leads:
GTCA36-XXXM-R10/GTCR36-XXXM-R10
Surface-mount: GTCS36-XXXM-R10
Surface-mount (T&R): GTCS36-XXXM-R10-2
100pcs (Tray)
100pcs (Tray)
100pcs (Tray)
750pcs
2,500pcs
1,000pcs
2,500pcs
6000pcs
Part Numbering System
Example Part Number: GTCX36-351M-R10-FT
GT =
C=
X=
3=
6=
351 =
M=
R=
10 =
FT =
Gas Tube
Ceramic
Lead Configuration: N= No leads; A= Axial Leads; S= Surface-mount; R= Radial Leads
3 Electrode device
6mm Diameter
DC Spark Over Voltage of 350V (at 100V/s)
Tolerance of 20% on DC Spark Over Voltage
Product Family Designator
Surge rating: 8x20µs 10kA 10 times
With Fail-Short mechanism
Gas Discharge Tubes
Document: SCD27380
Status: Released
Rev: C
Date: MAY 18, 2011
© 2008, 2011 Tyco Electronics Corporation.
a TE Connectivity Ltd. Company. All rights reserved.
5
Gas Discharge Tubes
GTCX36-XXXM-R10
Series
GTCX35-XXX-R05
Series
Part Marking Reference
Example Part Marking:
=
35 =
R10 =
GN =
35 R10 GN
Manufacture Mark
Voltage Designator (35 = 350V)
Product Family Designator + Surge Current 10kA (8x20µs 10 hits)
Year and Week of Manufacture
308 Constitution Drive, MS R21/2A
Menlo Park, CA USA 94025-1164
Tel (800) 227-7040
(650) 361-6 900
FAX (650) 361-2508
www.circuitprotection.com
www.circuitprotection.com.hk (Chinese)
www.circuitprotection.jp (Japanese)
TE Connectivity, TE Connectivity (Logo) and TE (Logo) are trademarks.
Information furnished is believed to be accurate and reliable. However, users should independently evaluate the suitability of and test each product
selected for their own applications. Tyco Electronics Corporation and/or its Affiliates in the TE Connectivity Ltd. family of companies (‘TE”) reserves the
right to change or update, without notice, any information contained in this publication; to change, without notice, the design, construction, processing, or
specification of any product; and to discontinue or limit production or distribution of any product. This publication supersedes and replaces all
information previously supplied. Without expressed or written consent by an officer of TE, TE does not authorize the use of any of its products as
components in nuclear facility applications, aerospace, or in critical life support devices or systems. TE expressly disclaims all implied warranties
regarding the information contained herein, including, but not limited to, any implied warranties of merchantability or fitness for a particular purpose. TE
only obligations are those in the TE Standard Terms and Conditions of Sale and in no case will TE be liable for any incidental, indirect, or consequential
damages arising from the sale, resale, use, or misuse of its products.
Gas Discharge Tubes
Document: SCD27380
Status: Released
Rev: C
Date: MAY 18, 2011
© 2008, 2011 Tyco Electronics Corporation.
a TE Connectivity Ltd. Company. All rights reserved.
6