Spec

M
MF Series: ( SMD TYPE )
◆ Features
■ Quick and repeated response
■ Small capacitance.
■ Stably absorb surge.
■ Small devices in electronic circuit and no polarity.
◆ Application
■ Surge protection for equipment connected to ISDN or LAN etc.
■ Devices connecting telecommunication line.Telephone, Fax machine, XDSL, Modem etc.
■ Devices connecting antenna or signal line. Booster, Car radio set etc.
■ Devices that need protection against electrostatic Display unit, Monitor TV, etc.
■ Used to protect switching power supplies and uninterruptible power systems.( UPS )
1. Scope :
This specification covers the MF SURGE SUPPRESSOR series for manufacturing gas tube
arrestors with the micro-gap system.
2. Partnumber :
Example:
MF -
301
M - 3D
(1)
(2)
(3)
(4)
(1) Series name
(2) DC Sparkover voltage
The first two digits are significant and the third is the number of zeros. Example: 301
Units in volts (V) .
30×10'⇒300V
(3) Tolerance of DC Sparkover voltage
MARK
L
M
N
Tolerance
±15%
±20%
±30%
(4) Taping form
MARK
3D
4D
Form
DL-35
DL-41
3. Temperature Range :
1)Operating temperature range : -40 ~ +125℃
2)Storage temperature range : -55 ~ +125℃
4. Structure :
glass
element ( conductive film coating )
gas
5. Dimension :
L
DL-35
Symbol
D
DL-41
D
Dimension (mm)
Φ1.35±0.01
L
3.3±0.05
Symbol Dimension (mm)
Φ2.6±0.1
D
L
5.0±0.1
6. Rating (Initial characteristics) :
Part number
DC sparkover
voltage
MF-141M
112~168
≧100
DC100V
≦1
MF-201M
160~240
≧100
DC100V
≦1
MF-301M
240~360
≧100
DC100V
≦1
MF-401M
320~480
≧100
DC250V
≦1
MF-501M
400~600
≧100
DC250V
≦1
MF-601M
480~720
≧100
DC250V
≦1
Insulation resistance
IR(MΩ)
Applied voltage
Capacitance
C (pF)
7. Performance :
No
1
Item
Standard test
condition
Test condition
Standard condition/temperature: 5~35℃
Best condition
Requirements
humidity : 45~85%RH.
/temperature: 25℃
humidity : 65%RH.
2
Appearance
Outer appearance shall be visually examined.
No visual damage
3
DC Sparkover
voltage
Measure starting discharge voltage by gradually
increasing applied DC voltage. Test current is
1mA max. and test period is 1 second max.
Meet specified value
4
Insulation resistance Measure the insulation resistance across the
terminal at regulated voltage.
5
Electrostatic
capacitance
6
Cold resistance
7
Heat resistance
100MΩ
Measure the electrostatic capacitance by applying 1pF or less
a voltage of less than 6V (at 1KHZ) between
terminals.
The specimen shall be subjected to -55±3℃ for Meet specified value
1000 hours without load and then stored at room
temperature and humidity for 4 hours.
Thereafter, the characteristics of items 2,3,4 and 5
shall be measured.
(in accordance with JIS C 0020)
The specimen shall be subjected to 125±2℃ for Meet specified value
1000 hours without load and then stored at room
temperature and humidity for 4 hours.
Thereafter, the characteristics of items 2,3,4 and 5
shall be measured.
(in accordance with JIS C 0021)
No
8
9
Item
Test condition
Requirements
Humidity resistance The specimen shall be subjected to 85±2℃ for
Meet specified value
1000 hours without load and then strored at room
temperature and humidity for 4 hours.
Thereafter, the characteristics of items 2,3,4 and 5
shall be measured.
(in accordance with JIS C 0021)
Temperature cycle
Repeat the temperature cycle shown below 25
Meet specified value
times then store parts at room temperature and
humidity for 4 hours.
Thereafter, the characteristics of items 2,3,4 and 5
shall be measured.
Step
1
2
Temperature
-55±3℃
Period
30minutes
3
Room Temp.
125±2℃
3minutes
30minutes
4
Room Temp
3minutes
(in accordance with JIS C 0025)
10 Vibration
The specimen shall be vibrated by its lead wires
Meet specified value
with a total amplitude of 1.5mm and a varying
frequency of 10~55~10HZ (each minute) for a
period of 60 minutes
respectively in each X,Y and Z directions.
Thereafter, the characteristics of items 2,3,4 and 5
shall be measured.
(in accordance with JIS C 0040)
11 Lead wire pull
strength
After gradually applying a 0.51kgf load, keep the Meet specified value
unit fixed for 30 seconds.
Thereafter, the characteristics of items 2,3,4 and 5
shall be measured.
(in accordance with JIS C 0051)
No
Item
Test condition
Requirements
12 Lead wire bending The unit shall be second with its lead wire kept
Meet specified value
strength
vertical and a 0.25kgf weight applied below in the
axial direction. The lead wire shall gradually be
bent to 90℃ in one direction at a point of 3mm from
.
the body along
the radius of curvature
(0.75~0.80mm), and again back to the original'
position.
This shall be repeated 2 times.
Thereafter, the characteristics of item 2,3,4 and shall
be measured.
(in accordance with JIS C 0051)
13 Solderability
After dipping the lead wire within 3mm of the body Lead wire is almost
in 260±5℃ solder for 5±0.5 seconds, the lead wire evenly covered with
shall be visually examined.
solder.
(in accordance with JIS C 0050, 4-6)
14 Resistance to
soldering heat
After dipping the lead wire within 3mm of the body Meet specified value
in 350±10℃ solder for 3±1 seconds, the
characteristics of items 2,3,4 and 5 shall be
measured.
(in accordance with JIS C 0050)
15 Surge life test
Apply a standard impulse voltage (10×1000)µ sec.)
of 1000V for 6 times with an interval of 30 seconds.
Then change the polarity of the surge and apply the
impulse again for another 6 times. And similarly,
apply a impulse voltage ((100×1000) µ sec.) of
1000 V.
Total number of a impulse voltage applied is 24
times. Thereafter, the characteristics of items 2,3,4
and 5 shall be measured.
(See figure 1)
16 Surge current
capacity
Apply standard impulse current (8×20)µ sec) of
500A(3D),1000A(4D) for 3 times with an interval
of 5 minutes between each impulse.
|ΔVs/Vs|≤30%
Characteristics of
items 1,3 and 4 must
meet the specified
value.
No cracks and wire
breaking
8. Dimensions and Taping