MACOM GTCA25-251M-R02

Gas Discharge Tubes
GTCX25-XXXM-R02 Series
TE Circuit Protection 5mm 2Pole GDTs (ceramic
gas discharge tubes), are commonly used to help
protect sensitive telecom equipment such as
communication lines, signal lines and data
transmission lines from damage caused by
transient surge voltages that typically result from
lightning strikes and equipment switching
operations.
Raychem Circuit Protection GDTs offer a high
level of surge protection, low capacitance and a
broad array of breakover voltage levels, making
them suitable for applications such as MDF (Main
Distribution Frame) modules, high data-rate
telecom applications (e.g. ADSL, VDSL), and
surge protection on power lines. Raychem Circuit
Protection GDTs, can help equipment meet the
most stringent regulatory standards.
Benefits:
Features:
 Compact, small form factor suitable for efficient
assembly
 2Pole, 5mm devices
 Broad voltage range from 75V-600V
 Helps provide overvoltage fault protection against
high energy surges
 Various form factors: surface mount, axial leads, no
leads
 Suitable for high-frequency applications
 Low capacitance and insertion loss
 UL 497B recognized
 RoHS compliant
 Devices tested per ITU K.12 recommendations
 Non-radioactive materials
Applications:
• Industrial and consumer electronics, such as
 Telecommunications
- MDF modules, xDSL equipment, RF system
- Surge protectors
protection, antenna, base station
- Alarm system
Gas Discharge Tubes
© 2008, 2011 Tyco Electronics Corporation,
a TE Connectivity Ltd. Company. All rights reserved.
1
Document: SCD27304
Status: Released
Rev: B
Date: MAY 11, 2011
Gas Discharge Tubes
GTCX25-XXXM-R02 Series
Device Voltage Ratings and Part Marking
Part Number
Impulse
Sparkover
DC Sparkover
DC Holdover
Voltage
On-State Voltage
@100V/s
±20% Tolerance
(V)
@100 V/µs (V)
@1000 V/µs (V)
GTCX25-750M-R02
75
450
550
<52
20
GTCX25-900M-R02
90
450
550
<52
20
GTCX25-141M-R02
140
500
600
<80
20
GTCX25-151M-R02
150
500
600
<80
20
GTCX25-201M-R02
200
600
700
<135
20
GTCX25-231M-R02
230
600
700
<135
20
GTCX25-251M-R02
250
600
700
<135
20
GTCX25-261M-R02
260
700
800
<135
20
GTCX25-301M-R02
300
800
900
<150
20
GTCX25-351M-R02
350
900
1000
<150
20
GTCX25-401M-R02
400
900
1000
<150
20
GTCX25-421M-R02
420
900
1000
<150
20
GTCX25-471M-R02
470
1050
1150
<150
20
GTCX25-501M-R02
500
1100
1200
<150
20
GTCX25-551M-R02
550
1300
1400
<150
20
GTCX25-601M-R02
600
1300
1400
<150
20
Per ITU K.12
(<150ms)
(V)
Nominal
(@ 1A)
(V)
Device Surge Rating, Capacitance, Insulation Resistance, UL
Part Number
GTCX25-xxxM-R02
Impulse
Discharge
Current
Impulse
Life
AC
Discharge
Current
(1sec duration;
10 hits)
Capacitance
Insulation
Resistance
UL
Rating
8x20µs
10 hits
10x1000µs
300 hits
@50 Hz
@1Mhz
@100V*
UL497B
#E179610
2.5kA
100A
2.5Arms
<1pF
10,000 (MΩ)
All Devices
Devices <=90V measured @ 50V
Devices >=500V measured @ 250V
Gas Discharge Tubes
© 2008, 2011 Tyco Electronics Corporation,
a TE Connectivity Ltd. Company. All rights reserved.
2
Document: SCD27304
Status: Released
Rev: B
Date: MAY 11, 2011
Gas Discharge Tubes
GTCX25-XXXM-R02 Series
DIMENSIONS = MILLIMETERS [INCHES]
Product Dimensions
Surface-mount (GTCS25-XXXM-R02)
No Leads (GTCN25-XXXM-R02)
Axial Leads (GTCA25-XXXM-R02)
Pad Layout – Surface- mount Devices (GTCS25-XXXM-R02)
mm:
in*:
X
NOM
6.0
(0.197)
Y
NOM
3.9
(0.154)
Z
NOM
1.3
(0.051)
Gas Discharge Tubes
© 2008, 2011 Tyco Electronics Corporation,
a TE Connectivity Ltd. Company. All rights reserved.
3
Document: SCD27304
Status: Released
Rev: B
Date: MAY 11, 2011
Gas Discharge Tubes
GTCX25-XXXM-R02 Series
GTCX25-XXXM-R02 Series
General Characteristics
No Radioactive Material
Storage Temperature: -40ºC to +90ºC
Operating Temperature: -40ºC to +90ºC
Body: Nickel Plated
Leads: Surface-mount, Axial Devices: Tin Plated
Devices with No Leads: Nickel Plated
Soldering Note: Devices with no leads are non-solderable; meant for insertion into magazine clips
m
Packaging Information
Part Description
Tray / Reel
Standard Package
No Leads:
GTCN25-XXXM-R02
Axial Leads:
GTCA25-XXXM-R02
Surface-mount: GTCS25-XXXM-R02
200pcs
5,000pcs
100pcs
1,000pcs
1,500pcs (Reel) 12,000pcs
Part Numbering System
Example Part Number: GTCX25-351M-R02
GT =
C=
X=
2=
5=
351 =
M=
R=
02 =
Gas Tube
Ceramic
Lead Configuration: N= No leads; A= Axial Leads; S= Surface-mount
2 Electrode device
5mm Diameter
DC Spark Over Voltage of 350V (at 100V/s)
Tolerance of 20% on DC Spark Over Voltage
Product Family Designator
Surge rating: 8x20µs 2.5kA 10 times
Gas Discharge Tubes
© 2008, 2011 Tyco Electronics Corporation,
a TE Connectivity Ltd. Company. All rights reserved.
4
Document: SCD27304
Status: Released
Rev: B
Date: MAY 11, 2011
Gas Discharge Tubes
GTCX25-XXXM-R02 Series
GTCX25-XXXM-R02 Series
Part Marking Reference
Example Part Marking:
=
35 =
R02 =
GN =
35 R02 GN
Manufacture Mark
Voltage Designator (35 = 350V)
Product Family Designator + Surge Current 2.5kA (8x20µs 10 hits)
Year and Week of Manufacture
308 Constitution Drive, MS R21/2A
Menlo Park, CA USA 94025-1164
Tel (800) 227-7040
(650) 361-6900
FAX (650) 361-2508
www.circuitprotection.com
www.circuitprotection.com.hk (Chinese)
www.circuitprotection.jp (Japanese)
TE Connectivity, TE Connectivity (Logo) and TE (Logo) are trademarks.
Information furnished is believed to be accurate and reliable. However, users should independently evaluate the suitability of and test each product
selected for their own applications. Tyco Electronics Corporation and/or its Affiliates in the TE Connectivity Ltd.family of companies(‘TE”) reserves the
right to change or update, without notice, any information contained in this publication; to change, without notice, the design, construction, processing, or
specification of any product; and to discontinue or limit production or distribution of any product. This publication supersedes and replaces all
information previously supplied. Without expressed or written consent by an officer of TE, TE does not authorize the use of any of its products as
components in nuclear facility applications, aerospace, or in critical life support devices or systems. TE expressly disclaims all implied warranties
regarding the information contained herein, including, but not limited to, any implied warranties of merchantability or fitness for a particular purpose. TE’
only obligations are those in the TE Standard Terms and Conditions of Sale and in no case will TE be liable for any incidental, indirect, or consequential
damages arising from the sale, resale, use, or misuse of its products.
Gas Discharge Tubes
© 2008, 2011 Tyco Electronics Corporation,
a TE Connectivity Ltd. Company. All rights reserved.
5
Document: SCD27304
Status: Released
Rev: B
Date: MAY 11, 2011