ETC MTN/PS001

DS0058 Issue 4 Page 1 of 2
MTN/VM110
Hand Held Vibration Meter
•
•
•
•
•
Multiple Measurements
LCD Display
AC or DC Outputs
Carrying Case
Battery Powered
Vibration Meter
VM 110
Peak
L.P. Filter (kHz)
5
20
Off
r.m.s
10
2g
20g
200g
Range
20 mm/sec
200 mm/sec
2000 mm/sec
20µm
200µm
2000µm
Monitran Ltd.
Standard Vibration Meter, Probe & Accessories
The MTN/VM110 Vibration Meter is a battery powered, portable instrument designed to
operate with a constant current type accelerometer (10mV/g sensitivity) to make vibration
measurements simple and convenient.
Both RMS and Peak detection of acceleration, velocity and displacement can be made in
three ranges.
A switched low pass filter for the reduction of wide band noise is provided.
An AC output via a ‘D’ type output socket allows the connection of additional filters or a
signal analyser. A DC output is also provided to drive a chart recorder.
Standard Package
ORDER CODE
PART NO.
MTN/VM110
MTN/2100
MTN/MM001
MTN/PS001
DESCRIPTION
VIBRATION METER
HAND HELD PROBE
MAGNETIC BASE ADAPTER
HAND HELD SPIKE ADAPTER
OTHER ACCESSORIES AVAILABLE
Monitran Ltd Monitor House Hazlemere Rd Penn Bucks UK HP10 8AD
Tel: +44 (0) 1494 816569 Fax: +44 (0) 1494 812256 email: [email protected] www.monitran.co.uk
Monitran reserves the right to alter the specification without prior notice
DS0058 Issue 4
Page 2 of 2
Technical Specification
Measurement
Ranges
Acceleration:
2g, 20g, 200g
Velocity:
20mm/sec, 200mm/sec, 2000mm/sec
Displacement:
20µm, 200µm, 2000µm
Frequency Range
Upper Frequency, selectable low pass filters of 5kHz, 10kHz,
20kHz
Lower Frequency fixed, Acc. 5Hz, Vel. 10Hz, Dis. 15Hz
Detector
Switch selectable: RMS or Peak
Display
12.7mm, 3½ digit LCD. 3 readings per second
Accuracy (10 mV/g
Input)
Figures are for the VM110 only, since input transducers will affect
the overall system accuracy. All readings are ±1 digit added to the
following full-scale errors.
Acc. 1.5% RMS; 3% Peak: Vel 2.5% RMS; 4% Peak: Dis 3.5%
RMS; 5% Peak (9% at 10kHz)
The equivalent input noise is the lowest measurable signal level in
the range due to internally generated electrical noise.
Equivalent Input
Noise
Acc:
RMS Noise
Peak Noise
2g range; 2mg
6mg
20g range; 2mg
6mg
200g range; 20mg 60mg
Inputs
Outputs
Power
Vel:
0.1mm/sec
0.3mm/sec
Dis:
0.2µm
0.6µm
Various accelerometers can be used in conjunction with the
VM110. For more details contact the sales office.
AC: 200mVac, full range as selected.
DC: 200mVdc, full range as selected.
2 x PP3 9V batteries. Battery low warning indicator on display.
Battery life is approximately 15 hours dependent on battery type.