DS0058 Issue 4 Page 1 of 2 MTN/VM110 Hand Held Vibration Meter • • • • • Multiple Measurements LCD Display AC or DC Outputs Carrying Case Battery Powered Vibration Meter VM 110 Peak L.P. Filter (kHz) 5 20 Off r.m.s 10 2g 20g 200g Range 20 mm/sec 200 mm/sec 2000 mm/sec 20µm 200µm 2000µm Monitran Ltd. Standard Vibration Meter, Probe & Accessories The MTN/VM110 Vibration Meter is a battery powered, portable instrument designed to operate with a constant current type accelerometer (10mV/g sensitivity) to make vibration measurements simple and convenient. Both RMS and Peak detection of acceleration, velocity and displacement can be made in three ranges. A switched low pass filter for the reduction of wide band noise is provided. An AC output via a ‘D’ type output socket allows the connection of additional filters or a signal analyser. A DC output is also provided to drive a chart recorder. Standard Package ORDER CODE PART NO. MTN/VM110 MTN/2100 MTN/MM001 MTN/PS001 DESCRIPTION VIBRATION METER HAND HELD PROBE MAGNETIC BASE ADAPTER HAND HELD SPIKE ADAPTER OTHER ACCESSORIES AVAILABLE Monitran Ltd Monitor House Hazlemere Rd Penn Bucks UK HP10 8AD Tel: +44 (0) 1494 816569 Fax: +44 (0) 1494 812256 email: [email protected] www.monitran.co.uk Monitran reserves the right to alter the specification without prior notice DS0058 Issue 4 Page 2 of 2 Technical Specification Measurement Ranges Acceleration: 2g, 20g, 200g Velocity: 20mm/sec, 200mm/sec, 2000mm/sec Displacement: 20µm, 200µm, 2000µm Frequency Range Upper Frequency, selectable low pass filters of 5kHz, 10kHz, 20kHz Lower Frequency fixed, Acc. 5Hz, Vel. 10Hz, Dis. 15Hz Detector Switch selectable: RMS or Peak Display 12.7mm, 3½ digit LCD. 3 readings per second Accuracy (10 mV/g Input) Figures are for the VM110 only, since input transducers will affect the overall system accuracy. All readings are ±1 digit added to the following full-scale errors. Acc. 1.5% RMS; 3% Peak: Vel 2.5% RMS; 4% Peak: Dis 3.5% RMS; 5% Peak (9% at 10kHz) The equivalent input noise is the lowest measurable signal level in the range due to internally generated electrical noise. Equivalent Input Noise Acc: RMS Noise Peak Noise 2g range; 2mg 6mg 20g range; 2mg 6mg 200g range; 20mg 60mg Inputs Outputs Power Vel: 0.1mm/sec 0.3mm/sec Dis: 0.2µm 0.6µm Various accelerometers can be used in conjunction with the VM110. For more details contact the sales office. AC: 200mVac, full range as selected. DC: 200mVdc, full range as selected. 2 x PP3 9V batteries. Battery low warning indicator on display. Battery life is approximately 15 hours dependent on battery type.